DOI QR코드

DOI QR Code

Recording and Reconstruction of large object area by using Reflection type Digital Holography Microscope System

반사형 디지털 홀로그래피 현미경 시스템에서의 조사면적 및 재생면적의 확대기록

  • Choi, Kyu-Hwan (Imaging Media Research Center, Korea Institute of Science and Technology) ;
  • Kim, Sung-Kyu (Imaging Media Research Center, Korea Institute of Science and Technology) ;
  • Cho, D. (Laser Spectroscopy Lab. Department of Physics, Korea University) ;
  • Yoon, Seon-Kyu (Nonlinear Lab., Department of Physics, Cheju national university)
  • 최규환 (한국과학기술연구원 영상미디어연구센터) ;
  • 김성규 (한국과학기술연구원 영상미디어연구센터) ;
  • 조동현 (고려대학교 물리학과 레이저 분광학 연구실) ;
  • 윤선규 (제주대학교 물리학과 비선형 광학 연구실)
  • Published : 2006.04.01

Abstract

A modified Michelson interferometer type digital holography microscopy system is developed. There is a problem about recording and numerical reconstruction area at the microscopy application of Michelson type interferometer structure in the digital holography field. In this paper, to overcome this problem, we developed a new reflection type digital holography microscope system and increased recording and numerical reconstruction area of target object.

마이켈슨 간섭계 시스템에 두 개의 Convex Lens를 추가함으로서 평면파 참조광을 유지 시키며, 물체에 조사되는 물체광의 조사면적을 증대시킬 수 있는 변형된 마이켈슨 간섭계를 제작하였다. 변형된 마이켈슨 간섭계를 반사형 디지털 홀로그래피 현미경 시스템(Digital Holography Microscope System)에 적용한 결과 두 개의 Convex Lens를 추가하지 않은 고전 마이켈슨 간섭계를 사용한 디지털 홀로그래피 현미경 시스템 보다 넓은 영역에 대해 물체를 기록 할 수 있으며 또한 보다 넓은 영역을 재생 할 수가 있다.

Keywords

References

  1. Gabor, D., 'A New Microscopic Principles', Nature 161, No. 4098, pp.777-778, 1948 https://doi.org/10.1038/161777a0
  2. Gabor, D., 'Microscopy by Reconstructed Wavefronts', Proc. Roy. Soc. (London) A 197, pp.454-487, 1949 https://doi.org/10.1098/rspa.1949.0075
  3. J. W. Goodman and R. W. Lawrence, 'Digital image formation from electronically detected holograms', Appl. Phys. Lett., vol. 11, pp.77-79, 1967 https://doi.org/10.1063/1.1755043
  4. M. A. Kronrod, N, S. Merzlyakov, and L. P. Yaroslavskii, 'Reconstruction of a hologram with a computer', Sov. Phys. Tech. Phys., vol. 17, pp. 444-334, 1972
  5. Haddad W, Cullen D, Solem J, Longworth J, McPherson A, Boyer K, Rhodes K Fourier-transform holographic microscope. Appl Opt 31(24), pp.4973-4978, 1992 https://doi.org/10.1364/AO.31.004973
  6. Kreuzer HJ, Pawlitzek RA, 'Numerical Reconstruction for in-line Holography in Reflection and under glancing Incidence', In: Juptner W, Osten W (eds) Proc 3rd International Workshop on Automatic Processing of Fringe Patterns. Akademie, Berlin, pp364-367, 1997
  7. Kebbel V, Hartmann HJ, Juptner W, 'Application of digital holographic microscopy for inspection of micro -optical components'. In:Proc SPIE vol 4398. pp 189-98, 2001
  8. Coppola G, De Nicola S, Ferraro P, Finizio A, Grilli S, Iodice M, Magro C, Pierattini G, 'Evaluation of residual stress in MEMS structures by means of digital holography', In: Proc. SPIE vol 4933, pp226-31, 2003
  9. U. Schnars, T. Kreis, and W. Juptner , 'Digital recording and numerical reconstruction of holograms reduction of the spatial frequency spectrum', Opt. Eng., vol. 35, no. 4, pp977-982, 1998
  10. 김성규, 최현희, 손정영, '디지털 홀로그래피에서의 공초점 렌즈계를 이용한 보다 큰 물체의 기록.' 한국광학회지, 제 14권 3호, pp. 244-248, 2003