A grid-line suppression technique based on the nonsubsampled contourlet transform in digital radiography

  • Namwoo Kim;Taeyoung Um;Hyun Tae Leem;Bon Tack Koo;Kyuseok Kim;Kyu Bom Kim
    • Nuclear Engineering and Technology
    • /
    • 제55권2호
    • /
    • pp.655-668
    • /
    • 2023
  • In radiography, an antiscatter grid is a well-known device for eliminating unexpected x-ray scatter. We investigate a new stationary grid artifact suppression method based on a nonsubsampled contourlet transform (NSCT) incorporated with Gaussian band-pass filtering. The proposed method has an advantage that extracts the Moiré components while minimizing the loss of image information and apply the prior information of Moiré component positions in multi-decomposition sub-band images. We implemented the proposed algorithm and performed a simulation and an experiment to demonstrate its viability. We did this experiment using an x-ray tube (M-113T, Varian, focal spot size: 0.1 mm), a flat-panel detector (ROSE-M Sensor, Aspenstate, pixel dimension: 3032 × 3800 pixels, pixel size: 0.076 mm), and carbon graphite-interspaced grids (JPI Healthcare, 18 cm × 24 cm, line density: 103 LP/inch and 150 LP/inch, ratio: 5:1, focal distance: 65 cm). Our results indicate that the proposed method successfully suppressed grid artifacts by reducing them without either reducing the spatial resolution or causing negative side effects. Consequently, we anticipate that the proposed method can improve image acquisition in a stationary grid x-ray system as well as in extended x-ray imaging.

Arsenic의 첨가량에 따른 방사선 검출센서 (a-Se)의 전기적 특성 비교 (The Comparison of Electric Characteristics of Radiation Detective Sensor(a-Se) with changing composition ratio of Arsenic)

  • 석대우;강상식;이동길;김재형;남상희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 추계학술대회 논문집 Vol.15
    • /
    • pp.391-394
    • /
    • 2002
  • There has recently been much interest and research in developing digital x-ray systems based on using amorphous selenium(a-Se) photoconductors as the image receptor. The amorphous selenium layer that is currently being studied for use as an x-ray photoconductor is not pure a-Se but rather amorphous selenium alloyed with arsenic. We fabricated samples using the selenium and arsenic alloy with various concentrations of the arsenic. In this work, x-ray photoconductor using amorphous selenium alloyed with arsenic were fabricated with different concentrations of the arsenic (0.1 wt.%, 0.3wt.%, 0.5wt.%, 1wt.%, 1.5wt.%, 3wt.%, 5wt.%). The seven kind of samples was fabricated with a-Se alloyed with arsenic through vacuum thermal evaporation. We also investigate the arsenic concentration dependence on the device performance in radiation detector. The electric characteristics of radiation detector devices with changing additive ratio of the arsenic is performed by measuring the x-ray induced photocurrent and integrating it over time to find the total charge. The thickness of a-Se is $100{\mu}m$. Bias voltages $3V/{\mu}m$, $6V/{\mu}m$$9V/{\mu}m$ are applied at the samples. As results, the net charge of a-Se 0.3% As sample is $526.0pC/mR/cm^2$ at $9V/{\mu}m$ bias. The net charge is decreased as with the increasing additive ratio of arsenic.

  • PDF

입자침전법을 이용한 광도전체 필름의 X선 반응 특성에 관한 연구

  • 최치원;강상식;조성호;권철;남상희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 하계학술대회 논문집 Vol.8
    • /
    • pp.176-176
    • /
    • 2007
  • Flat-panel direct conversion detectors used in compound substance of semiconductor are being studied for digital x-ray imaging. Recently, such detectors are deposited by physical vapor deposition(PVD) generally. But, most of materials (HgI2, PbI2, TlBr, PbO) deposited by PVD have shown difficult fabrication and instability for large area x-ray imaging. Consequently, in this paper, we propose applicable potentialities for screen printing method that is coated on a substrate easily. It is compared to electrical properties among semiconductors such as $HgI_2$, $PbI_2$, PbO, HgBrI, InI, and $TlPbI_3$ under investigation for direct conversion detectors. Each film detector consists of an ~25 to $35\;{\mu}m$ thick layer of semiconductor and was coated onto the substrate. Substrates of $2cm{\times}2cm$ have been used to evaluate performance of semiconductor radiation detectors. Dark current, sensitivity and physics properties were measured. Leakage current of $HgI_2$ as low as $9pA/mm^2$ at the operation bias voltage of ${\sim}1V/{\mu}m$ was observed. Such a value is not better than PVD process, but it is easy to be fabricated in high quality for large area x-ray Imaging. Our future efforts will concentrate on optimization of growth of film thickness that is coated onto a-Si TFT array.

  • PDF

디지털 방사선시스템에서 영상증강 파라미터의 영상특성 평가 (Image Quality Evaluation of Medical Image Enhancement Parameters in the Digital Radiography System)

  • 김창수;강세식;고성진
    • 한국콘텐츠학회논문지
    • /
    • 제10권6호
    • /
    • pp.329-335
    • /
    • 2010
  • 디지털 방사선시스템에서의 의료영상 획득의 방법은 X선을 조사하고, 반도체 디텍터(Detector)를 이용하여 직접 및 간접으로 변환하여 기존 업체마다 여러 가지 알고리즘을 적용하여 적절한 이미지 프로세싱을 거쳐서 임상의 적정한 영상을 획득한다. 방사선과에서 적절한 의료 영상 형성을 위하여 적용하는 이미지 프로세싱 파라미터(Image Processing Parameters)는 Edge, Frequency, Contrast, Latitude, LUT, Noise 등의 영상 증강의 과정은 기술력 및 업체 알고리즘에 따라 다르게 적용되고 있다. 따라서 본 논문에서는 디지털 방사선 환경에서의 최종의 임상 영상을 위한 이미지 증강의 파라미터들의 적정 세팅 값의 기준을 제시하고자 한다. 그리고 각 병원들의 의료 영상을 바탕으로 이미지 프로세싱 파라미터들을 변화하여 각 파라미터들의 세부적인 기준 세팅값을 연구하며, 실제적인 파라미터 변화에 대한 적합한 의료 영상을 디지털방사선시스템의 영상 평가 방법을 도식화하여 결과를 제시하고, 향후 임상에서 적응 및 활용 가능한 객관적인 영상 파라미터에 대한 특성 평가의 응용을 정립하고자 한다. 또한 다양한 표본 병원의 디지털 방사선 환경에서 적정 파라미터 값들을 조사하여 임상에서 영상의 화질에 미치는 영향으로 특성 평가의 객관적인 기준의 변조전달함수(MTF)의 공간해상력을 제시하고 한다.

디지털 X선 영상센서 적용을 위한 진공증착 CsI 특성평가 (The X-ray Detection Characteristic of vacuum evaporated CsI for Digital X-ray Image Sensor)

  • 신정욱;박지군;최장용;석대우;김재형;남상희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 춘계학술대회 논문집 센서 박막재료 반도체 세라믹
    • /
    • pp.15-18
    • /
    • 2003
  • In recent years, there has been keen interest in phosphor materials responding X-ray. Cesium iodide of the materials is a material with a high $\gamma$-ray stopping power due to its relative high density and atomic number. CsI is noted for its high resistance to thermal and mechanical shock due to the absence of a cleavage plane. To design the structure of CsI detector, we analysed the structure with SEM and XRD and measured UV meter.

  • PDF

병원관리 전산화

  • 김윤상
    • 대한의용생체공학회:의공학회지
    • /
    • 제3권1호
    • /
    • pp.49-50
    • /
    • 1982
  • In this paper, the information capacity, the intergrate performance measure of digital radiography system has been quantitatively analyzed. The effect of various factors affecting the information capacity of the digital radiography system in multi-stage detection processes has been considered and analyzed in detail. The results show that the more information capacity can be obtained with the smaller detector cell area, despite of the reduced signal to noise ratio due to the reduced number of X-ray photons per detector cell. Considering the limit of human visual acuity. however, the sufficient resolution will be obtained when the detector cell size in 0.2${\times}$0.2mm with 8 bit quantizaion. And also the results indicates that the information capacity may be severely reduced by the mixture of electric noise in final read-out stage.

  • PDF

형광체 기반 X선 광 변조기를 위한 비정질 셀레늄 필름 특성 (Characterization of the a-Se Film for Phosphor based X-ray light Modulator)

  • 강상식;박지군;조성호;차병열;신정욱;이건환;문치웅;남상희
    • 대한의용생체공학회:의공학회지
    • /
    • 제28권2호
    • /
    • pp.306-309
    • /
    • 2007
  • PXLM(Phosphor based x-ray light modulator) has a combined structure by phosphor, photoconductor, and liquid crystal and it can realize x-ray image of high resolution in clinical diagnosis area. In this study, we fabricated a photoconductor and investigated electrical and optical properties to confirm application possibility of radiator detector of PXLM structure. As photoconductor, amorphous selenium(a-Se), which is used most in DR(Digital radiography) of direct conversion method, was used and for formation of thin film, it was formed as $20{\mu}m-thick$ by using thermal vacuum evaporation system. For a produced a-Se film, through XRD(X-ray diffraction) and SEM(Scanning electron microscope), we investigated that amorphous structure was uniformly established and through optical measurement, for visible light of 40 $0\sim630nm$, it had absorption efficiency of 95 % and more. After fabricated a-Se film on the top of ITP substrate, hybrid structure was manufactured through forming $Gd_2O_3:Eu$ phosphor of $270{\mu}m-thick$ on the bottom of the substrate. As the result to confirm electrical property of the manufactured hybrid structure, in the case of appling $10V/{\mu}m$, leakage current of $2.5nA/cm^2$ and x-ray sensitivity of $7.31nC/cm^2/mR$ were investigated. Finally, we manufactured PXLM structure combined with hybrid structure and liquid crystal cell of TN(Twisted nematic) mode and then, investigated T-V(Transmission vs. voltage) curve of external light source for induced x-ray energy. PXLM structure showed a similar optical response with T-V curve that common TN mode liquid crystal cell showed according to electric field increase and in appling $50\sim100V$, it showed linear transmission efficiency of $12\sim18%$. This result suggested an application possibility of PXLM structure as radiation detector.

디지털 엑스선유방촬영장치에서 검출기 위치에 따른 공간분해능의 변화 (Changes in Spatial Resolution at Position of the Detector in Digital Mammography System)

  • 김민혜;천권수
    • 한국방사선학회논문지
    • /
    • 제10권3호
    • /
    • pp.215-222
    • /
    • 2016
  • 엑스선유방촬영술은 다양한 유방질환 중 석회화 병변을 진단하는데 가장 효과적인 방법이다. 환자의 의료피폭 저감과 진단에 필요한 최적의 영상을 얻기 위해서는 성능유지를 지속적으로 관리해야 한다. 엑스선유방촬영술에서 엑스선을 발생시키는 양극의 경사각도는 중심선을 기준으로 하기 때문에 조사야 내의 위치에 따라 엑스선관의 유효초점이 미세하게 달라질 수 있어 공간분해능의 차이가 발생할 수 있다. 본 연구에서는 디지털 엑스선유방촬영장치에서 검출기 위치에 따른 LSF를 측정하여 MTF를 계산함으로써 공간분해능 변화에 대해서 연구하였다. 와이어 직경에 대한 변화에서 $50{\mu}m$ 직경의 와이어의 경우 가장 높은 공간주파수 값을 나타냈으며 검출기의 픽셀보다 작은 직경을 갖는 와이어를 사용해야 검출기의 공간주파수에 따른 응답을 바르게 구할 수 있다는 것을 알 수 있었다. 조사야 내의 검출기의 위치에 따라서 공간주파수는 중심부분의 와이어가 나머지 와이어보다 우수한 MTF 특성을 보였으나, 그 차이는 미소하게 나타났다. 또한 중앙부분에서 반치폭 또는 유효초첨이 가장 작게 나타났으며 중앙에서 벗어날수록 반치폭이 증가하여 공간분해능이 낮아진 것으로 나타났다.

X선 스펙트럼 모델을 이용한 DR 화소값과 디텍터 흡수에너지의 관계에 대한 정량적 분석 (Quantitative Analysis of Digital Radiography Pixel Values to absorbed Energy of Detector based on the X-Ray Energy Spectrum Model)

  • 김도일;김성현;호동수;최보영;서태석;이재문;이형구
    • 한국의학물리학회지:의학물리
    • /
    • 제15권4호
    • /
    • pp.202-209
    • /
    • 2004
  • 현재 평판 디텍터를 이용한 디지털 방사선 촬영기술은 방사선 진단 기술 분야에 있어서 매우 중요하고 유용하게 사용되고 있다. 비정질 실리콘 광센서를 사용하는 디지털 방사선 촬영기에는 흡수되는 방사선 에너지를 가시광선으로 변환하는 신틸레이터로 보통 CsI(TI)를 사용한다. 신틸레이터에서 만들어진 가시광선은 이차원 평면으로 구성된 비정실 실리콘 광 다이오드에서 전기적 신호로 전환된다. 좋은 질의 영상을 얻기 위해서는 디지털 방사선 촬영기(Digital Radiography, DR) 디텍터의 방사선에 대한 세부적인 특성 연구가 필수적이다. 이러한 이유로 조사선량과 디지털 방사선 촬영기의 신호의 관계에 대해서 많은 연구가 이루어졌지만 현재까지의 연구에서는 고정된 관전압의 조건에서 두 변수의 관계에 대한 연구가 이루어졌다. 이에 본 연구에서는 X선 스펙트럼 모델인 SPEC-78을 사용하여 조사선량 대신 디텍터에 흡수되는 에너지와 디지털 방사선 촬영기의 신호와의 관계를 규명하였다. SPEC-78의 주요 입력변수인 X-ray 튜브의 고유 필터 값을 구하기 위해 조사선량을 측정하여 계산한 조사선량과 비교하였다. 물질에 흡수되는 X-ray의 에너지를 계산하는 알고리즘을 상정하여 디텍터에 흡수되는 에너지를 계산하고 다양한 조건에서 실제 X선 영상의 화소값을 획득하였다. 두변수의 관계를 이용해 특성곡선을 얻었으며 이 결과를 검증하기 위해서 물과 알루미늄으로 제작된 팬텀을 이용하였다. 다양한 조건에서 팬텀 영상의 화소값을 측정하였고 특성곡선과 비교하였다 이러한 과정으로 진행된 연구의 결과로 디텍터에 흡수되는 에너지와 디지털 방사선 촬영기의 신호는 거의 선형적임을 알 수 있었다. 또한 팬텀을 이용한 실험에서도 산란된 광자의 영향으로 유발된 약간의 오차에도 불구하고 측정되어진 화소값은 특성곡선과 잘 일치하였다 본 연구를 통해 규명되어진 두 변수의 관계는 예상과 거의 일치하였지만 산란선에 대한 부분은 흡수에너지 계산 알고리즘에서 빠져있어 더 연구가 되어야 할 부분이다. 본 연구를 통해 얻어진 자료들은 디지털 방사선 촬영기의 전처리 과정에 있어서 중요한 정보를 제공할 수 있을 것이라 생각된다.

  • PDF

Detection of Second-Layer Corrosion in Aging Aircraft Fuselage

  • Kim, Noh-Yu;Achenbach, J.D.
    • 비파괴검사학회지
    • /
    • 제26권6호
    • /
    • pp.417-426
    • /
    • 2006
  • A Digital X-ray imaging system using Compton backscattering has been developed to obtain a cross-sectional profile and mass loss of corroded lap-splices of aging aircraft from density variation. A slit-type camera was designed to focus on a small scattering volume inside the material, from which the backscattered photons are collected by a collimated scintillator detector for interpretation of material characteristics. The cross section of the lap-joint is scanned by moving the scattering volume through the thickness direction of the specimen. The mass loss of each layer has been estimated from a Compton backscatter A-scan to obtain the thickness of each layer including the aluminum sheet, the corrosion layer and the sealant. Quantitative information such as location and width of planar corrosion in the lap splices of fuselages is obtained by deconvolution using a nonlinear least-square error minimization method(BFGS method): A simple reconstruction model is also introduced to overcome distortion of the Compton backscatter data due to attenuation effects attributed to beam hardening and quantum noise.