• 제목/요약/키워드: Digital Thermography

검색결과 32건 처리시간 0.027초

Preliminary Application of Stone Conservation Technology for Monitoring of Vat Phou World Heritage Site

  • Sengphachanh, Amphol;Lee, Myeong Seong;Choi, Tae Jeong;Chun, Yu Gun
    • 보존과학연구
    • /
    • 통권36호
    • /
    • pp.86-96
    • /
    • 2015
  • From the Asia Cooperation Program on Conservation Science(ACPCS) of National Research Institute of Cultural Heritage(NRICH), I gained conservation and management experience and knowledges which are highly applicable at the Vat Phou World Heritage site. Firstly, Check list, Mapping, Tape Test and Digital Image Analysis are simple and useful methods which can be introduced to the site directly. If we can get chance to learn more about GIS program, GIS based Database Management System would also be very liable to put into practical use since the site office has been already using the program for general purpose. Lastly, there are more other methods which can diversify the studies on cultural heritage conservation in Laos; Rebound Hardness Test, Ultrasonic Test, Infrared Thermography, XRF Analysis and Hyperspectral Image Analysis etc. To realize those research however, new equipments are needed along with proper education so more cooperation between Korea and Lao would be essential.

  • PDF

개발한 진단용 다엽조리개 성능평가 및 X선영상과 적외선체열영상의 융합영상 구현 (Performance Evaluation of the Developed Diagnostic Multi-Leaf Collimator and Implementation of Fusion Image of X-ray Image and Infrared Thermography Image)

  • 권순무;심재구;천권수
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제42권5호
    • /
    • pp.365-371
    • /
    • 2019
  • We have developed and applied a diagnostic Multi-Leaf Collimator (MLC) to optimized the X-ray field in medical imaging and the usefulness evaluated through the fusion of infrared image and X-ray image acquired by infrared camera. The hand and skull radiography with multi-leaf collimator(MLC) showed significant area dose reductions of 22.9% and 31.3% compared to ARC and leakage dose was compliant with KS A 4732. Also scattering doses of 50 cm and 100 cm showed a significant decrease to confirm the usefulness of MLC. It was confirmed that the fusion of infrared images with an adjustable degree of transparency was possible in the X-ray images. Therefore, fusion of anatomical information with physiological convergence is expected to contribute and improvement of diagnostic ability. In addition, the feasibility of convergence X-ray imaging and DITI devices and the possibility of driving MLC with infrared images were confirmed.

EPAR V2.0: AUTOMATED MONITORING AND VISUALIZATION OF POTENTIAL AREAS FOR BUILDING RETROFIT USING THERMAL CAMERAS AND COMPUTATIONAL FLUID DYNAMICS (CFD) MODELS

  • Youngjib Ham;Mani Golparvar-Fard
    • 국제학술발표논문집
    • /
    • The 5th International Conference on Construction Engineering and Project Management
    • /
    • pp.279-286
    • /
    • 2013
  • This paper introduces a new method for identification of building energy performance problems. The presented method is based on automated analysis and visualization of deviations between actual and expected energy performance of the building using EPAR (Energy Performance Augmented Reality) models. For generating EPAR models, during building inspections, energy auditors collect a large number of digital and thermal imagery using a consumer-level single thermal camera that has a built-in digital lens. Based on a pipeline of image-based 3D reconstruction algorithms built on GPU and multi-core CPU architecture, 3D geometrical and thermal point cloud models of the building under inspection are automatically generated and integrated. Then, the resulting actual 3D spatio-thermal model and the expected energy performance model simulated using computational fluid dynamics (CFD) analysis are superimposed within an augmented reality environment. Based on the resulting EPAR models which jointly visualize the actual and expected energy performance of the building under inspection, two new algorithms are introduced for quick and reliable identification of potential performance problems: 1) 3D thermal mesh modeling using k-d trees and nearest neighbor searching to automate calculation of temperature deviations; and 2) automated visualization of performance deviations using a metaphor based on traffic light colors. The proposed EPAR v2.0 modeling method is validated on several interior locations of a residential building and an instructional facility. Our empirical observations show that the automated energy performance analysis using EPAR models enables performance deviations to be rapidly and accurately identified. The visualization of performance deviations in 3D enables auditors to easily identify potential building performance problems. Rather than manually analyzing thermal imagery, auditors can focus on other important tasks such as evaluating possible remedial alternatives.

  • PDF

초음파 서모그라피를 이용한 실시간 결함 검출에 대한 연구 (A Study on Real-Time Defect Detection Using Ultrasound Excited Thermography)

  • 조재완;서용칠;정승호;정현규;김승호
    • 비파괴검사학회지
    • /
    • 제26권4호
    • /
    • pp.211-219
    • /
    • 2006
  • 초음파 서모그라피는 초음파 진동 에너지 여기에 의한 물체의 표면 및 표면 아래에 존재하는 결함부위의 선택적 발열 특성을 적외선 열영상 카메라로 관측하는 것이다. 결함(균열, 박리, 공극 등) 이 존재하는 구조물에 초음파 진동 에너지를 입사시킬 경우 결함 부근에서의 국부적인 발열로 인해 건전 부위와의 급격한 온도차를 드러내는 핫 스폿이 관측된다. 초음파 진동 에너지 여기에 의한 핫 스폿 관측 및 분석을 통해 결함을 진단하는 것이 초음파 서모그라피를 이용한 비파괴 결함 진단 방법이다. 이를 이용한 결함 검출을 위해서는 초음파의 진동에너지를 검사 구조물에 효율적으로 전달하는 것이 중요하다 본 논문에서는 초음파 서모그라피를 이용한 실시간 결함검출에 대해 기술한다. 초음파 진동에너지의 입사 방향에 따른 결함 검출 특성을 평가하기 위해 진동에너지의 전달 방향을 시편과 수직 또는 수평방향으로 각각 입사시켰다. 각각의 입사 방향에 따른 초음파 트랜스듀서 양단에 인가되는 전압을 디지털 오실로스코우프로 계측 비교하였다. 결함 검출에 사용한 시편은 14 mm 두께의 SUS 균열(crack) 시편, PCB 기판(1.8 mm), 인코넬 600 판(1.0 mm) 및 CFRP 판(3.0 mm)의 4종류이다. 4종류의 시편에 대해 280ms 펄스폭의 초음파에너지를 수직 수평으로 각각 입사시켰다. 4종류 모두 수직방향으로 초음파 진동에너지를 입사시켰을 때 수평방향에 비해 전달 손실이 적었다. 복합재료인 PCB, CFRP 판은 수직방향으로 초음파 진동에너지를 입사시켰을 때 수평방향에 비해 결함 위치에서 열이 크게 발생하였으며 선택적 발열 현상도 3배 이상 지속되었다. 금속재료인 인코넬 600판과 SUS 시편은 수평방향이 수직방향보다 핫 스폿이 빨리 관측되었다.

컴퓨터 적외선(赤外線) 전신체열촬영(全身體熱撮影)으로 본 경추추간판(頸椎椎間板) 탈출증(脫出症)의 침구치료효과(鍼灸治療效果) (Clinical evaluation of Acupuncture on Herniated of Cervical Intervertebral Disc by DITI)

  • 이건목
    • 대한한의학회지
    • /
    • 제16권1호통권29호
    • /
    • pp.132-140
    • /
    • 1995
  • Object : This study is designed to evaluate the correlation between the data of DITI(Digital Infrared Thermographic Imaging)examination and the changes of clinical symptom after the therapy of acupuncture in the patients with herniated cervical intervertebral disc. Content : The conservative therapy with acupuncture was performed during $4{\sim}5$ weeks, The acupuncture points of SI3, B62, TE3, G34, LI4, S36, GV26, G21, SII5 were used. In the pre- and post therapy, DITI examinations were performed in patients who had HIVD and were treated by acupuncture simultaneously, and then tried to correlate the results of clinical symptoms with the difference of thermographic findings at pre-acupuncture and post-acupuncture. Setting : The standard routine thermoghaphic examinations were performed with thermography(DITI) in the 15 patients with lumbar disc herniations at pre- and post acupuncture. Patient : Thermographic imaging of 15 cases were analyzed. They has disc herniations in X-ray, CT scan and MRI and they were treated by acupuncture theraphy in our hospital from March, 1994 to January, 1995. Result : 1) The causes were trauma(60%), retention of phlegm and fluid(8.7%) and cold & moisture(33.3%) 2) Levels of herniated cervical disc are C2/3(1 case). C3/4(2 cases), C5/6 & C6/7 (2 cases), C6/7(4 cases), Normal(6 cases). 3) Classifications of thermographic pattern are radiculopathy(80%), spot(13.3%), and nonspecific(6.7%) in order. 4) In evaluation Results of clinical symptom are Excellent(80%), Good(6.7%), and Poor(6.7%). Data of DITI are Excellent(80%), Good(6.7%), Fair(6.7%), and Poor(6.7%). Conclusion ; Acupuncture showed good results over 86.7% in clinical evaluation and 86.7% in DITI. Thermographic examination was valuable in the evaluation of therapeutic effect of acupuncture treatment.

  • PDF

적외선 영상 복사계를 이용한 산간집수역의 찬공기 배수와 온난대 형성 관측 (Observation of the Cold-air Drainage and Thermal Belt Formation in a Small Mountainous Watershed by Using an Infrared Imaging Radiometer)

  • 윤진일
    • 한국농림기상학회지
    • /
    • 제13권2호
    • /
    • pp.79-86
    • /
    • 2011
  • 산간계곡에는 특히 야간에 찬 공기가 흘러 고이는 일이 흔한데, 이런 곳의 식생은 생장과 발육이 그렇지 않은 주변지역에 비해 달라질 수 있어 관심의 대상이 다. 이 연구는 작은 규모의 집수역에서 적외선 영상을 이용하여 냉기호와 온난대의 형상을 가시화 할 수 있는지 알기 위해 수행하였다. 경남 하동군 악양면 형제봉(해발 1,117m)에 적외선 영상 복사계를 설치하여 관측여건이 양호했던 2011년 5월 17일 새벽부터 일출시까지 악양계곡의 열영상을 $640{\times}480$ 해상도로 획득하였다. 열영상 분석결과 계곡의 바닥에 나타난 낮은 온도 분포에 의해 찬공기의 배수를 인지할 수 있었고, 계곡 양쪽 사면에서 바닥보다 $5^{\circ}C$ 높은 온난대의 실체를 확인할 수 있었다. 적외선 영상을 이용하면 기존 고해상도 디지털 기온분포도 '전자기후도'의 신뢰성 검증이 한층 수월해져서 전자기후도 실용성 확보에 도움이 될 것이다.

A semi-automated method for integrating textural and material data into as-built BIM using TIS

  • Zabin, Asem;Khalil, Baha;Ali, Tarig;Abdalla, Jamal A.;Elaksher, Ahmed
    • Advances in Computational Design
    • /
    • 제5권2호
    • /
    • pp.127-146
    • /
    • 2020
  • Building Information Modeling (BIM) is increasingly used throughout the facility's life cycle for various applications, such as design, construction, facility management, and maintenance. For existing buildings, the geometry of as-built BIM is often constructed using dense, three dimensional (3D) point clouds data obtained with laser scanners. Traditionally, as-built BIM systems do not contain the material and textural information of the buildings' elements. This paper presents a semi-automatic method for generation of material and texture rich as-built BIM. The method captures and integrates material and textural information of building elements into as-built BIM using thermal infrared sensing (TIS). The proposed method uses TIS to capture thermal images of the interior walls of an existing building. These images are then processed to extract the interior walls using a segmentation algorithm. The digital numbers in the resulted images are then transformed into radiance values that represent the emitted thermal infrared radiation. Machine learning techniques are then applied to build a correlation between the radiance values and the material type in each image. The radiance values were used to extract textural information from the images. The extracted textural and material information are then robustly integrated into the as-built BIM providing the data needed for the assessment of building conditions in general including energy efficiency, among others.

컴퓨터 적외선(赤外線) 전신체열촬영(全身體熱撮影)을 통해 살펴본 Bell' palsy에 대한 한방적 치료의 임상적(臨床的) 고찰(考察) (Clinical evaluation of Acupuncture and Herb-Medication on Bell's palsy by DITI)

  • 조은희;조남근;허태영;천미나
    • Journal of Acupuncture Research
    • /
    • 제17권2호
    • /
    • pp.19-30
    • /
    • 2000
  • Object : This study is designed to evaluate effects of acupuncture and herb-medication by the data of DITI(Digital Infrared Thermographic Imaging) examination and the changes of clinical symptoms after the therapy of acupuncture and herb-medication in the patients with Bell's palsy. Contents : The conservative therapy with acupuncture and herb-medication was performed during 1-8weeks. The acupuncture points of S4, S6, G14, S2, BL2, SI18, TE23, LI4 and S36 was used. In the pre- and post therapy, DITI examinations were performed in patients who had Bell's palsy and were treated by acupuncture simultaneously, and then tried to correlate the results of clinical symptoms with the difference of thermographic findings at pre-and post acupuncture. Setting : The standard routine themographic examinations were performed with thermography (DITI) in the 16 patients with Bell's palsy at pre- and post acupuncture. patients : Thermographic imaging of 16cases was analyzed. They had diagnosed Bell's palsy. They were treated by acupuncture and moxibustion therapy in Wonkwang Oriental Hospital from Jauary, 1999 to February, 2000. Results : The results of treatment showes that 56.25% of patients achieved excellent recovery and 31.25% achieved good recovery. After compairing the DITI results before and after treatment, we found 43.75% of patients achieved excellent recovery and 43.75% achieved good recovery. Conclusion :Acupuncture showed good results over 87.5% in clinical evaluation and 87.5% in DITI. Thermographic examination showes terapeutic effect of acupuncture treatment.

  • PDF

컴퓨터 적외선(赤外線) 전신체열촬영(全身體熱撮影)을 통한 척추 전방 전위증의 임상적(臨床的) 고찰(考察) (Clinical evaluation of Acupuncture on spondylolisthesis by DITI)

  • 허태영;조남근;조은희;천미나
    • Journal of Acupuncture Research
    • /
    • 제17권2호
    • /
    • pp.31-39
    • /
    • 2000
  • Object : This study is designed to evaluate the correlation between the data of DITI(Digital Inrared Thermographic Imaging) examination and the changes of clinical symptoms after the therapy of acupuncture in the patients with spondylolisthesis. Contents : The conservative therapy with acupuncture was performed during 3-4weeks. The acupuncture points of BL23, BL24, BL25, BL40, BL57, BL60, BL62, GB30, GB31, ST36, TE3 was used. In the pre- and post therapy, DITI examinations were performed in patients who had spondylolisthes in L-spine X-ray and were treated by acupuncttare simultaneously, and then tried to correlate the results of clinical symptoms with the difference of thermographic findings at pre-and post acupuncture. Setting : The standard routine thermographic exanninations were performed with thermography (DITI) in the 22 patients with spondylolisthesis at pre- and post acupuncture. Patients : Thermographic imaging of 22 cases was analyzed. They had diagnosed spondylolisthes in L-spine X-ray. They were treated by acupuncture and moxibustion therapy in Wonkwang Oriental Hospital from May, 1998 to May, 2000. Results : 1) The causes were congenital (4.5%), overwork (31.85%), trauma (13.65%), degenerative factor(50%) 2) The DITI results showed 45.4% below $0.3^{\circ}C$, 36.4% between 0.3 and $0.5^{\circ}C$, 4.5% between 0.5 and $0.7^{\circ}C$, 9.1% between 0.7 and $0.9^{\circ}C$, and 4.5% over $0.9^{\circ}C$. 3) The results of treatment using pain scale showes that 27.3% of patientsachieved excellent recovery and 54.6% achieved good recovery. After compairing the DITI results before and after treatment, we found 45.4% of patients achieved excellent recovery and 36.4% achieved good recovery. Conclusion : Acupuncture showed good results over 81.9% in clinical evaluation and 81.8% in DITI. Thermographic examination was valuable in the evaluation of therapeutic effect of acupuncture treatment.

  • PDF

적외선열화상장치를 이용한 Buchanan plugger 표면의 온도상승 분석 (INFRARED THERMOGRAPHIC ANALYSIS OF TEMPERATURE RISE ON THE SURFACE OF BUCHANAN PLUGGER)

  • 최성아;김선호;황윤찬;윤창;오병주;최보영;정우남;정선와;황인남;오원남
    • Restorative Dentistry and Endodontics
    • /
    • 제27권4호
    • /
    • pp.370-381
    • /
    • 2002
  • This study was performed to evaluate the temperature rise on various position of the Buchanan plugger, the peak temperature of plugger's type and the temperature change by its touching time of heat control spling. The heat carrier system 'System B' (Model 1005, Analytic Technologies, USA) and the Buchanan's plug-gers of F, FM, M and ML sizes are used for this study. The temperature was set to 20$0^{\circ}C$ which Dr. Buchanan's "continuous wave of condensation" technique recommended on digital display and the power level on it was set to 10. In order to apply heat on the Buchanan's pluggers, the heat control spring was touched for 1, 2, 3, 4 and 5 seconds respectively. The temperature rise on the surface of the pluggers were measured at 0.5 mm intervals from tip to 20 mm length of shank using the infrared thermography (Radiation Thermometer-IR Temper, NEC San-ei Instruments, Ltd, Japan) and TH31-702 Data capture software program (NEC San-ei Instruments, Ltd, Japan). Data were analyzed using a one way ANOVA followed by Duncan's multiple range test and linear regression test. The results as follows. 1. The position at which temperature peaked was approximately at 0.5 mm to 1.5 mm far from the tip of Buchanan's pluggers (p<0.001). The temperature was constantly decreased toward the shank from the tip of it (p<0.001). 2. When the pluggerss were heated over 5 seconds, the peak temperature by time of measurement revealed from 253.3$\pm$10.5$^{\circ}C$ to 192.1$\pm$3.3$^{\circ}C$ in a touch for 1 sec, from 218.6$\pm$5.$0^{\circ}C$ to 179.5$\pm$4.2$^{\circ}C$ in a touch for 2 sec, from 197.5$\pm$3.$0^{\circ}C$ to 167.5$\pm$3.7$^{\circ}C$ in a touch for 3 sec, from 183.7$\pm$2.5$^{\circ}C$ to 159.8$\pm$3.6$^{\circ}C$ in a touch for 4 sec and from 164.9$\pm$2.$0^{\circ}C$ to 158.4$\pm$1.8$^{\circ}C$ in a touch for 5 sec. A touch for 1 sec showed the highest peak temperature, followed by, in descending order, 2 sec, 3 sec, 4 sec. A touch for 5 sec showed the lowest peak temperature (p<0.001). 3. A each type of pluggers showed different peak temperatures. The peak temperature was the highest in F type and followed by, in descending order, M type, ML type. FM type revealed the lowest peak temperature (p<0.001). The results of this study indicated that pluggers are designed to concentrate heat at around its tip, its actual temperature does not correlate well with the temperature which Buchanan's "continuous wave of condensation" technique recommend, and finally a quick touch of heat control spring for 1sec reveals the highest temperature rise.