• Title/Summary/Keyword: Digital Radiography

Search Result 488, Processing Time 0.028 seconds

A Study on the Resolution Analysis of Digital X-ray Images with increasing Thickness of PMMA (조직 등가물질 두께 증가에 따른 디지털 엑스선 영상의 해상도 분석에 관한 연구)

  • Kim, Junwoo
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.2
    • /
    • pp.173-179
    • /
    • 2021
  • Scattered x-ray generated by digital radiography systems also have the advantage of increasing signals, but ultimately detectability is reduced by decreasing resolution and increasing noise of x-ray images transmitted objects. An indirect method of measuring scattered x-ray in a modulation-transfer function (MTF) for evaluating resolution in a spatial-frequency domain can be considered as a drop in the MTF value corresponding to zero-frequency. In this study, polymethyl methacrylate (PMMA) was used as a patient tissue equivalent, and MTFs were obtained for various thicknesses to quantify the effect of scattered x-ray on resolution. X-ray image signals were observed to decrease by 35 ~ 83% with PMMA thickness increasing, which is determined by the absorption or scattering of x-rays in PMMA, resulting in reduced MTF and increased scatter fraction. The method to compensate for MTF degradation by PMMA resulted in the MTF inflation without considering the optical spreading generated by the indirect-conversion type detector. Data fitting or zero-padding are needed to compensate for MTF more reasonably on edge-spread function or line-spread function.

Truncation Artifact Reduction Using Weighted Normalization Method in Prototype R/F Chest Digital Tomosynthesis (CDT) System (프로토타입 R/F 흉부 디지털 단층영상합성장치 시스템에서 잘림 아티팩트 감소를 위한 가중 정규화 접근법에 대한 연구)

  • Son, Junyoung;Choi, Sunghoon;Lee, Donghoon;Kim, Hee-Joung
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.1
    • /
    • pp.111-118
    • /
    • 2019
  • Chest digital tomosynthesis has become a practical imaging modality because it can solve the problem of anatomy overlapping in conventional chest radiography. However, because of both limited scan angle and finite-size detector, a portion of chest cannot be represented in some or all of the projection. These bring a discontinuity in intensity across the field of view boundaries in the reconstructed slices, which we refer to as the truncation artifacts. The purpose of this study was to reduce truncation artifacts using a weighted normalization approach and to investigate the performance of this approach for our prototype chest digital tomosynthesis system. The system source-to-image distance was 1100 mm, and the center of rotation of X-ray source was located on 100 mm above the detector surface. After obtaining 41 projection views with ${\pm}20^{\circ}$ degrees, tomosynthesis slices were reconstructed with the filtered back projection algorithm. For quantitative evaluation, peak signal to noise ratio and structure similarity index values were evaluated after reconstructing reference image using simulation, and mean value of specific direction values was evaluated using real data. Simulation results showed that the peak signal to noise ratio and structure similarity index was improved respectively. In the case of the experimental results showed that the effect of artifact in the mean value of specific direction of the reconstructed image was reduced. In conclusion, the weighted normalization method improves the quality of image by reducing truncation artifacts. These results suggested that weighted normalization method could improve the image quality of chest digital tomosynthesis.

Image Quality Evaluation of CsI:Tl and Gd2O2S Detectors in the Indirect-Conversion DR System (간접변환방식 DR장비에서 CsI:Tl과 Gd2O2S의 검출기 화질 평가)

  • Kong, Changgi;Choi, Namgil;Jung, Myoyoung;Song, Jongnam;Kim, Wook;Han, Jaebok
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.1
    • /
    • pp.27-35
    • /
    • 2017
  • The purpose of this study was to investigate the features of CsI:Tl and $Gd_2O_2S$ detectors with an indirect conversion method using phantom in the DR (digital radiography) system by obtaining images of thick chest phantom, medium thickness thigh phantom, and thin hand phantom and by analyzing the SNR and CNR. As a result of measuring the SNR and CNR according to the thickness change of the subject, the SNR and CNR were higher in CsI:Tl detector than in $Gd_2O_2S$ detector when the medium thickness thigh phantom and thin hand phantom were scanned. However, when the thick chest phantom was used, for the SNR at 80~125 kVp and the CNR at 80~110 kVp in the $Gd_2O_2S$ detector, the values were higher than those of CsI:Tl detector. The SNR and CNR both increased as the tube voltage increased. The SNR and CNR of CsI:Tl detector in the medium thickness thigh phantom increased at 40~50 kVp and decreased as the tube voltage increased. The SNR and CNR of $Gd_2O_2S$ detector increased at 40~60 kVp and decreased as the tube voltage increased. The SNR and CNR of CsI:Tl detctor in the thin hand phantom decreased at the low tube voltage and increased as the tube voltage increased, but they decreased again at 100~110 kVp, while the SNR and CNR of $Gd_2O_2S$ detector were found to decrease as the tube voltage increased. The MTF of CsI:Tl detector was 6.02~90.90% higher than that of $Gd_2O_2S$ detector at 0.5~3 lp/mm. The DQE of CsI:Tl detector was 66.67~233.33% higher than that of $Gd_2O_2S$ detector. In conclusion, although the values of CsI:Tl detector were higher than those of $Gd_2O_2S$ detector in the comparison of MTF and DQE, the cheaper $Gd_2O_2S$ detector had higher SNR and CNR than the expensive CsI:Tl detector at a certain tube voltage range in the thick check phantom. At chest X-ray, if the $Gd_2O_2S$ detector is used rather than the CsI:Tl detector, chest images with excellent quality can be obtained, which will be useful for examination. Moreover, price/performance should be considered when determining the detector type from the viewpoint of the user.

Adequacy of Source to Image Receptor Distance with Chest Postero-Anterior Projection in Digital Radiology System (디지털방사선 환경에서 흉부 후-전 방향 검사 시 초점과 영상수용체간 거리의 적절성)

  • Joo, Young-Cheol;Lim, Cheong-Hwan;You, In-Gyu;Jung, Hong-Ryang;Lee, Sang-Ho
    • Journal of radiological science and technology
    • /
    • v.39 no.2
    • /
    • pp.135-142
    • /
    • 2016
  • The purpose of this study is to evaluate propriety of using SID 180cm at Chest PA examination and to find effect of geometrical cause to the image. XGEO-GC80, INNOVISION-SH, CXDI-40EG detector and a chest phantom designed self-production was used for this study. Images were acquired at SID 180cm with changing the factor OID as 0, 75 and 83mm and were analyzed by Centricity Radiography RA1000 PACS system. Statistical program was used the SPSS (Version 22.0, SPSS, Chicago, IL, USA), p-value(under 0.05) was considered to be statistically significant. In OID 0 mm was enlarged about 2.7~3.5 mm than the actual degree of the HS, BS of phantom in all equipments. Compared with the calculated magnification has been expanded 1.6~2.8% when viewed. The OID 75 mm with OID 83 mm was extended from the CS and BS 6~8 mm range. Compared to the calculated values, the measured values are expanded from 6.1 to 7.9%. CS and BS according to the OID change showed a statistically significant difference (p<0.05) among each group, the post-analysis only OID 0 mm group appeared as an independent group, 75 mm and 83 mm are separated in the same group It was. But had no statistically significant difference could change depending on the OID (p>0.05), post-mortem analysis showed, both in the same group. Heart sizes appears larger than actual size 6~8 mm at chest PA examination which is enlarged 6.1~7.9% more than the actual theoretical value. We can find magnification of the image because of the increase of the OID due to technical limitations between cover of standing detector and the image plate. so we suggest to have occurred between them when considering the need to adjust the equipment installed by the SID to match the characteristics of the equipment.

A Study on Protection Performance of Radiation Protective Aprons classified by Manufacturers and Lead Equivalent using Over Tube Type Fluoroscopy (Over Tube Type의 투시촬영장치를 이용한 제조사별, 납당량별 엑스선방어 앞치마의 Protection 성능 평가에 관한 연구)

  • Song, Jong-Nam;Seol, Gwang-Wook;Hong, Seong-Il;Choi, Jeong-Gu
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.3
    • /
    • pp.135-141
    • /
    • 2011
  • If protective performance of apron cannot be good, radiation exposure of an guardian or a patient, a person engaged in radiation related industry cannot rise. Therefore, It will be evaluated protection performance to radiation protection aprons by manufacturers and lead equivalent more than 0.25mm lead equivalent. And, will show in the direction of application to clinic. The new aprons by manufacturers(H, X, I, J company) and lead equivalent(0.50mmPb, 0.35mmPb, 0.25mmPb) measured transmitted dose rate and shielding rate, uniformity under fluoroscopy and general radiography using to fluoroscopy system and digital radiography system, x-ray multifunction meter. The shielding rate measurement results, 0.5mmPb apron was Shielding rate of apron of a I company(fluoroscopy : 97.96%) was the best under six companies, and shielding rate of apron of a J company(fluoroscopy : 96.25%) was worst. 0.35mmPb Apron was Shielding rate of a I company(fluoroscopy : 96.79%) was the best under the three companies, and shielding rate of an H company(fluoroscopy : 95.81%) was the worst. 0.25mmPb Apron was Shielding rate of X company apron(fluoroscopy : 90.908%) was better than H company apron(fluoroscopy : 88.82%) than two companies. The uniformity measurement results, 0.5mmPb Aprons of X company(fluoroscopy : 0.13) and I company(fluoroscopy : 0.19) was the best under the six companies, and J company apron(fluoroscopy : 0.45) was the worst. 0.35mmPb. Along a manufacturer and lead equivalent performance of apron protection is distinguished certainly. Therefore, a patient, guardian or a person engaged in radiation related industry shall enforce experiment of a lot of ways defined or evaluation so that the maximum reduces radiation exposure. Buy the apron that protective performance is good, It will be performed through experiment and evaluation.

Correlation Analysis of Factors Affecting the Collimator Size used during Lumbar Spine Lateral Examination in Digital Radiography System (디지털 방사선 장비에서 요추 측면 검사 시 사용되는 조사야 크기에 영향을 미치는 요인의 상관관계 분석)

  • Young-Cheol Joo;Sin-Young Yu
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.4
    • /
    • pp.345-353
    • /
    • 2024
  • The purpose of this study was to suggest an appropriate collimation size and central X-ray incidence point by analyzing the correlation between the collimation size used in lumbar lateral examination and factors affecting the collimation size. the lumbar lateral examination results of 148 patients suitable for the purpose of this study were analyzed. The measurement method was to set the total horizontal width shown in the image to the size of the irradiation field(collimation) used during the examination. The distance connected vertically from the end of the dorsal field to the apophyseal joint of the third lumbar vertebra(AJD), the distance from the dorsal end of the image field to the center of the body of the third lumbar vertebra(BD), and the distance from the end of the dorsal field of the image to the center of the pedicle of the third lumbar vertebra(PD). The distance was measured. For comparative analysis of the mean values of dependent variables according to gender, age, height, weight, and body mass index, the mean values were compared using the independent samples t test and one-way ANOVA. For post hoc analysis, duncan was used. The correlation between independent and dependent variables was analyzed using Pearson correlation analysis. In this study, statistical significance was set at a p value of 0.05 or lower. The average value of the collimation size during the lumbar spine lateral examination was 252.45 mm, AJD was 102.11 mm, BD was 141.17 mm, and PD was 119.73 mm. The mean values of collimation size, AJD, BD, and PD were larger in men than in women, but statistical significance for the difference in mean values by gender was found only in BD (p<0.05). There was a slight difference in the mean value of each group according to age, but there was no statistical significance (p>0.05). The collimation size and mean values of AJD, BD, and PD according to height, weight, and body mass index differed depending on the independent variables, and the differences were all statistically significant (p<0.05). As a result of the correlation analysis, field size and AJD, BD, and PD showed no correlation with gender and age, a weak positive correlation with height, and a medium positive correlation with weight and body mass index. The results of this study showed that CS was correlated with height, weight, and BMI during lumbar lateral examination. If the entrance point of the central X-ray is moved to the appophyseal joint by considering weight and BMI when adjusting the collimation size in clinical practice, it is expected that the collimation size can be reduced bu about 5%.

Treatment of Class II Furcation Involvements in Humans with Bioabsorbable Guided Tissue Regeneration Barriers (2급 치근분지부 병소에서의 생분해성 차폐막의 효과)

  • Lee, Hak-Churl;Han, Seoung-Min;Seol, Yang-Jo;Lee, Chul-Woo;Um, Heung-Sik;Chang, Beom-Suk;Chung, Chong-Pyoung;Han, Soo-Boo
    • Journal of Periodontal and Implant Science
    • /
    • v.29 no.3
    • /
    • pp.539-553
    • /
    • 1999
  • The purpose of this 6-months study was to compare the clinical and radiographic outcomes following guided tissue regeneration treating human mandibular Class II furcation defects with a bioabsorbable BioMesh barrier(test treatment) or a nonabsorbable ePTFE barrier(control treatment). Fourteen defects in 14 patients(mean age 44 years) were treated with BioMesh barriers and ten defects in 10 patients(mean age 48 years) with ePTFE barriers. After initial therapy, a GTR procedure was done. Following flap elevation, root planing, and removal of granulation tissue, each device was adjusted to cover the furcation defect. The flaps were repositioned and sutured to complete coverage of the barriers. A second surgical procedure was performed at control sites after 4 to 6 weeks to remove the nonresorbable barrier. Radiographic and clinical examinations(plaque index, gingival index, tooth mobility, gingival margin position, pocket depth, clinical attachment level) were carried out under standardized conditions immediately before and 6 months after surgery. Furthermore, digital subtraction radiography was carried out. All areas healed uneventfully. Surgical treatment resulted in clinically and statistically equivalent changes when comparisons were made between test and control treatments. Changes in plaque index were 0.7 for test and 0.4 for control treatments; changes in gingival index were 0.9 and 0.5. In both group gingival margin position and pocket depth reduction was 1.0mm and 3.0mm; clinical attachment level gain was 1.9mm. There were no changes in tooth mobility and the bone in radiographic evaluation. No significant(p${\leq }$0.05) difference between the two membranes could be detected with regard to plaque index, gingival index, gingival margin position, pocket depth, and clinical attachment level. In conclusion, a bioabsorbable BioMesh membrane is effective in human mandibular Class II furcation defects and a longer period study is needed to fully evaluate the outcomes.

  • PDF

Characterization of the a-Se Film for Phosphor based X-ray light Modulator (형광체 기반 X선 광 변조기를 위한 비정질 셀레늄 필름 특성)

  • Kang, Sang-Sik;Park, Ji-Koon;Cho, Sung-Ho;Cha, Byung-Youl;Shin, Jung-Wook;Lee, Kun-Hwan;Mun, Chi-Woong;Nam, Sang-Hee
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.2
    • /
    • pp.306-309
    • /
    • 2007
  • PXLM(Phosphor based x-ray light modulator) has a combined structure by phosphor, photoconductor, and liquid crystal and it can realize x-ray image of high resolution in clinical diagnosis area. In this study, we fabricated a photoconductor and investigated electrical and optical properties to confirm application possibility of radiator detector of PXLM structure. As photoconductor, amorphous selenium(a-Se), which is used most in DR(Digital radiography) of direct conversion method, was used and for formation of thin film, it was formed as $20{\mu}m-thick$ by using thermal vacuum evaporation system. For a produced a-Se film, through XRD(X-ray diffraction) and SEM(Scanning electron microscope), we investigated that amorphous structure was uniformly established and through optical measurement, for visible light of 40 $0\sim630nm$, it had absorption efficiency of 95 % and more. After fabricated a-Se film on the top of ITP substrate, hybrid structure was manufactured through forming $Gd_2O_3:Eu$ phosphor of $270{\mu}m-thick$ on the bottom of the substrate. As the result to confirm electrical property of the manufactured hybrid structure, in the case of appling $10V/{\mu}m$, leakage current of $2.5nA/cm^2$ and x-ray sensitivity of $7.31nC/cm^2/mR$ were investigated. Finally, we manufactured PXLM structure combined with hybrid structure and liquid crystal cell of TN(Twisted nematic) mode and then, investigated T-V(Transmission vs. voltage) curve of external light source for induced x-ray energy. PXLM structure showed a similar optical response with T-V curve that common TN mode liquid crystal cell showed according to electric field increase and in appling $50\sim100V$, it showed linear transmission efficiency of $12\sim18%$. This result suggested an application possibility of PXLM structure as radiation detector.

Radiographic Bone Density Around Immediately Placed Titanium Implant on the Extraction Socket of Diabetic and Insulin-Treated Rat Maxilla (당뇨쥐 상악에서 발치후 즉시 식립 임플란트 주위골의 방사선 골밀도)

  • Park, Kun-Hyun;Park, Su-Hyun;Lee, Sung-Hwy;Pyo, Sung-Woon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.32 no.5
    • /
    • pp.389-395
    • /
    • 2010
  • Purpose: Although it is generally accepted that patients with controlled diabetes have similar rates of success for dental implants as healthy individuals, the use of dental implants in diabetic patients is controversial. In addition, the impact of diabetes on the healing of bone associated with immediately place dental implants is not completely understood. The purpose of this study was to measure bone response to implants radiologically in uncontrolled and insulin-controlled diabetic rats. Materials and Methods: Twenty rats were divided into control, insulin-treated and diabetic groups. The rats received streptozotocin (60 mg/kg) to induce diabetes; animals in the insulin-treated group also received three units of subcutaneous slow-release insulin. Two titanium implants ($1.2{\times}3$ mm) were placed in the extraction socket of the maxillary first molars of the animals and were harvested at 3 days, 1, 2 and 4 weeks. The bone density was measured by digital radiography using gray-level analysis (histogram) in the regions of interest (ROI) at four points: two mesial and two distal to both sides of the implant. Results: The results showed that the osseointegration of the implants was impaired in the diabetic rats compared to the control and the insulin-treated rats. The radiographic evidence demonstrated marked destruction of bone around the implants in the diabetic group. Both the control and the insulin-treated groups had a significantly higher bone density on radiograph than the diabetic group from the 1 week of the experiment (P<0.05 for each comparison). Conclusion: The present study revealed that the immediate placement of titanium implants in the maxilla of diabetic rat lead to delay in the maturation of bone adjacent to implants. It is expected that the reduced predictability of success of immediate implantation in patient with the uncontrolled diabetes.

The effects of pentoxifylline and tocopherol in jaw osteomyelitis

  • Seo, Mi Hyun;Eo, Mi Young;Myoung, Hoon;Kim, Soung Min;Lee, Jong Ho
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.46 no.1
    • /
    • pp.19-27
    • /
    • 2020
  • Objectives: Pentoxifylline (PTX) is a methylxanthine derivative that has been implicated in the pathogenesis of peripheral vessel disease and intermittent lameness. The purpose of this study was to investigate the effect of PTX and tocopherol in patients diagnosed with osteoradionecrosis (ORN), bisphosphonate-related osteonecrosis of the jaw (BRONJ), and chronic osteomyelitis using digital panoramic radiographs. Materials and Methods: This study was performed in 25 patients who were prescribed PTX and tocopherol for treatment of ORN, BRONJ, and chronic osteomyelitis between January 2014 and May 2018 in Seoul National University Dental Hospital. Radiographic densities of the dental panorama were compared prior to starting PTX and tocopherol, at 3 months, and at 6 months after prescription. Radiographic densities were measured using Adobe Photoshop CS6 (Adobe System Inc., USA). Blood sample tests showing the degree of inflammation at the initial visit were considered the baseline and compared with results after 3 to 6 months. Statistical analysis was performed using the Mann-Whitney test and repeated measurement ANOVA using IBM SPSS 23.0 (IBM Corp., USA). Results: Eight patients were diagnosed with ORN, nine patients with BRONJ, and the other 8 patients with chronic osteomyelitis. Ten of the 25 patients were men, average age was 66.32±14.39 years, and average duration of medication was 151.8±80.65 days (range, 56-315 days). Statistically significant increases were observed in the changes between 3 and 6 months after prescription (P<0.05). There was no significant difference between ORN, BRONJ, and chronic osteomyelitis. Only erythrocyte sedimentation rate (ESR) was statistically significantly lower than before treatment (P<0.05) among the white blood cell (WBC), ESR, and absolute neutrophil count (ANC). Conclusion: Long-term use of PTX and tocopherol can be an auxiliary method in the treatment of ORN, BRONJ, or chronic osteomyelitis in jaw.