Static-Error-Free Digital PID Voltage Regulator for UPS Inverter (정상상태오차 없는 UPS 인버터용 디지털 PID 전압 제어기)

  • Kim, Byoung-Jin;Choi, Jae-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.1227-1229
    • /
    • 2000
  • The output voltage of UPS must not vary according to the load variation But the output voltage varies due to the load variation when a PI voltage regulator is used which has inherently a static state error. This paper presents a static-error-free digital PID voltage regulator for an UPS inverter to overcome additionally the voltage unbalance problem in three Phase system as well as the above problem.

  • PDF

An Improved Stationary Frame-based Digital Current Control Scheme for a PM Synchronous Motor

  • Kim Kyeong-Hwa;Youn Myung-Joong
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.174-178
    • /
    • 2001
  • An improved stationary frame-based digital current control technique for a permanent magnet (PM) synchronous motor is presented. Generally, the stationary frame current controller is known to provide the advantage of a simple implementation. However, there are some unavoidable limitations such as a steady-state error and a phase delay in the steady-state. On the other hand, in the synchronous frame current regulator, the regulated currents are dc quantities and a zero steady-state error can be obtained through the integral control. However, the need to transform the signals between the stationary and synchronous frames makes the implementation of a synchronous frame regulator complex. Although the PI controller in the stationary frame gives a steady-state error and a phase delay, the control performance can be greatly improved by employing the exact decoupling control inputs for the back EMF, resulting in an ideal steady-state control characteristics irrespective of an operating condition as in the synchronous PI decoupling controller. However, its steady-state response may be degraded due to the inexact cancellation inputs under the parameter variations. To improve the control performance in the stationary frame, the disturbance is estimated using the time delay control. The proposed scheme is implemented on a PM synchronous motor using DSP TMS320C31 and the effectiveness is verified through the comparative simulations and experiments.

  • PDF

An Improved Stationary Frame-based Digital Current Control Scheme for a PM Synchronous Motor

  • Kim, Kyeong-Hwa;Young, Myung-Joong
    • Journal of Power Electronics
    • /
    • v.1 no.2
    • /
    • pp.88-98
    • /
    • 2001
  • An improved stationary frame-based digital current control technique for a permanent magnet(PM) synchronous motor is presented. Generally, the stationary frame current controller is known to provide the advantage of a simple implementation. However, there are some unavoidable limitations such as a steady-state error and a phase delay in the steady-state. On the other hand, in the synchronous frame current regulator the regulated currents are dc quantities and a zero steady-state error can be obtained through the integral control. However, the need to transform the signals between the stationary and synchronous frames makes the implementation of a synchronous frame regulator complex. Although the PI controller in the stationary frame gives a steady-state error and a phase delay, the control performance can be greatly improved by employing the exact decoupling control inputs for the back EMF., resulting in an ideal steady-state control characteristics irrespective of an operating condition as in the synchronous PI decoupling controller. However, its steady-state response may be degraded due to the inexact cancellation inputs under the parameter variations. To improve the control performance in the stationary frame, the disturbance is estimated using the time delay control. The proposed scheme is implemented on a PM synchronous motor using DSP TMS320C31 and the effectiveness is verified through the comparative simulations and experiments.

  • PDF

A Sensorless Speed Control of Brushless DC Motor in Digital Lightening Processor using the Linear Quadratic Regulator (DLP용 BLDC 모터의 속도 센서리스 제어)

  • Yang, Iee-Woo;Kim, Young-Seok;Kim, Sang-Uk;Kim, Hyun-Jung
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1102-1103
    • /
    • 2007
  • This Paper presents a solution to control the Brushless DC Motor(BLDCM) in Digital Lightening Processor(DLP) using the Linear Quadratic Regulator(LQR). Generally, The speed of BLDCM in DLP is controlled by the lead angle control or the input voltage control using PAM(Pulse Amplitude Modulation) etc. These control methods have speed overshoot in speed control and need the long time until BLDCM reaches at the steady state. In order to improve the performance, this paper present the PI speed controller using the LQR based on vector control and the rotor position detection methods at the space vector PWM inverter. The proposed methods are proved by the experimental results

  • PDF

Development of real time control program package for digital control (디지탈 제어를 위한 실시간 제어용 프로그램 팩케지 개발)

  • 김상봉;이충환
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1991.10a
    • /
    • pp.317-321
    • /
    • 1991
  • In recent years, the discrete-data and digital control systems have gained importance in all industies due in part to the advances made in microcomputers, as well as the advantages found in working with digital signals. So, the developments of the computer aided design packages to analysis, control law design and digital implementation of control systems are increasingly needed and those substantial technological improvements are now expected. In the paper, a real time control program package(RTCPP) for the implementation of digital control is developed by using C language. The digital controls for the feedfoward and feedback controllers such as PI(propotional and Integration) type, regulator and servo types can be implemented by an IBM PC compatible computer with some interface modules of A-D/D-A converter and RS-232C. The effectiveness of RTCPP is illustrated by the application controls for motor and magnetic levitation systems.

  • PDF

Voltage Control of a Synchronous Generator for Ship using a Compound Type Digital AVR (혼합형 디지털 자동 전압 조정 장치를 이용한 선박용 동기발전기의 출력전압제어)

  • Park, Sang-Hoon;Lee, Sang-Seuk;Yu, Jae-Sung;Lee, Su-Won;Won, Chung-Yuen
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.4
    • /
    • pp.397-403
    • /
    • 2009
  • In this paper, an exciter current control of a synchronous generator for ships using a compound type digital automatic voltage regulator (DVAR) in order to provide a constant output voltage of the generator is presented. The compound type DAVR is composed of a controller part to adjust output voltage and an power source unit to supply power to the exciter. The controller part, which generates the PWM switching pattern via the PI controller, drives a power MOSFET for bypass to limit the SG's exciter current. The power source unit part is parallel connected to an output terminal of the generator through a reactor and a power CT. The residual magnetic flux of SG provides exciter current to the exciter through the reactor during the initial running or no load state and load current supplies field current to the exciter through the power CT during loading state. This paper confirmed an experiment to verify the validity of compound type DAVR system for controlling output voltage of synchronous generator.

Analysis and Compensation of Current Measurement Error in Digitally Controlled AC Drives (디지털 제어 교류 전동기 구동시스템의 전류 측정 오차 해석 및 보상)

  • 송승호;최종우;설승기
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.4 no.5
    • /
    • pp.462-473
    • /
    • 1999
  • This paper addresses the current measurement issue of all digital field oriented control of ac motors. The p paper focuses on the effect of low-pass filter and also on the sampling of the fundamental component of the m motor current. The low-pass filter, which suppresses the switching noise of the motor current, introduces v variable phase delay according to the current ripple frequency. It is shown that the current sampling error c consists of the fundamental component and high frL'quency ripple components. In this paper, the dependency of t this current sampling e$\pi$or on the reference voltage vector is investigated analytically and a sampling technique i is proposed to minimize the error. The work is based on the three phase symmetry pulse width modulation l inverter driving an induction machine. With this technique, the bandwidth of current regulator can be extended t to the limit given by the switching frequency of the inverter and more precise torque regulation is possible.

  • PDF