• Title/Summary/Keyword: Digital Contrast Technology

Search Result 135, Processing Time 0.031 seconds

3D DCT Video Information Hiding

  • Kim, Young-Gon;Jie Yang;Lee, Hye-Joo;Hong, Jin-Woo;Lee, Moon-Ho
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.169-172
    • /
    • 2002
  • Embedding information into video data is a topic that recently gained increasing attention. This paper proposes a new approach for digital watermarking and secure copyright protection of video, the principal aim being to discourage illicit copying and distribution of copyrighted material. The method presented here is based on the three dimensional discrete cosine transform of video scene, in contrast with previous works on video watermarking where each video frame was marked separately, or where only intra-frame or motion compensation parameters were marked in MPEG compressed videos. The watermark sequence used is encrypted, pseudo-noise signal to the video. The performance of the presented technique is evaluated experimentally

  • PDF

Cyber Social Interactions: Information Behavior in Between Social and Parasocial Interactions

  • Stock, Wolfgang G.;Fietkiewicz, Kaja J.;Scheibe, Katrin;Zimmer, Franziska
    • Journal of Information Science Theory and Practice
    • /
    • v.10 no.3
    • /
    • pp.15-23
    • /
    • 2022
  • Participants in real-time online sessions, be it (business) meetings, virtual school lessons, or social live streams, all engage in cyber social interactions. Unlike parasocial interactions, cyber social interactions are characterized by reciprocity and temporal proximity. In contrast to social interactions, they lack spatial proximity and bodily contact. This is a fairly new concept in information science that rose from technological advances and unprecedented circumstances (e.g., the rise of digital economy and knowledge workers being able to work remotely or, more recently, global lockdowns and contact restrictions). As a result, the past ways of working and socializing were transformed by making them, in some cases predominantly, virtual. Regarding the example of social live streaming we exhibit the importance of cyber social interactions for information behavior research. This conceptual article is a plea for information science to engage more in human-human online relations and interactions.

A Study on Dose and Image Quality according to X-ray Photon Detection Method in Digital Radiography System (Digital Radiography System에서 X선 광자 검출 방식에 따른 선량 및 화질 특성에 관한 연구)

  • Hong, Sun Suk;Kim, Ho Chul
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.12
    • /
    • pp.247-253
    • /
    • 2013
  • The purpose is a comparative evaluation in the DR System according to the dosimetry and image quality of the quantitative and objective via Direct digital radiography, Indirect digital radiography, Image intensifier (Charge Coupled Device type) digital radiography. The experimental method used rando phantom and measured the entrance surface dose. And through using the measured entrance surface dose and then using the PCXMC program were evaluated risk due to irradiation and the effective dose. SNR and NPS and CNR were measured and analyzed by using 21cm acryl phantom. Significance of measured value was evaluated by statistics method. Entrance surface dose, major organ dose, effective dose all of them were measured the lowest rated in direct DR when it is on the basis of direct DR dose, high-dose ratio were measured in I.I DR approximately 1.3 times, indirect DR approximately 2.4 times. Risk in accordance with radiation also was measured same as dose ratio. On the conclusion that SNR measurement result based on direct DR SNR measurements, low-SNR ratio were measured in I.I DR approximately 7.25 times, indirect DR approximately 1.48 times. On the conclusion that CNR measurement result based on direct DR CNR measurements, high-dose ratio were measured in I.I type DR approximately 1.16 tims and low-dose ratio were measured in indirect DR approximately 0.87 times. Therefore Direct DR system using a-selenium sensing element to detect x-ray photon is thought effectively at the examination such as infant to sensitive irradiation and the genital gland. Because quality image is built by low dose. Also when it is necessary that image test requiring many diagnosis information, indirect DR system is thought effectively.

A Study on Dynamic Susceptibility-weighted Perfusion MR Imaging at High Magnetic Filed : Comparison of Gradient Echo-EPI and Spin Echo-EPI (고 자장에서 Dynamic Susceptibility Contrast 효과에 관한 연구 : Gradient EPI와 Spin-EPI기법의 비교)

  • Goo, Eun-Hoe;Chae, Hong-In;Park, Jong-Bae;Im, Cheong-Hwan;Kim, Jeong-Koo
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.9 no.2
    • /
    • pp.11-16
    • /
    • 2007
  • We have evaluated and compared of gradient echo and spin echo EPI for compensating about deeply distortion aspect in case of post-operation patients in magnetic resonance image. A total of 100 patients were performed on 3.0 T(GE Signa Excite E2, USA) with 8ch head coil. As a result of analysis, The SNRs of whiter and gray matter areas were 36.74 $\pm$ 06 and 39.96 $\pm$ 09 in the gradient echo EPI, the SNRs which white and gray matter areas were slightly higher than gradient echo EPI(P<0.005, paired student t-test). It was 46.24 $\pm$ 11 and 51.38 $\pm$ 13 in gradient and spin echo EPI, respectively. The signal intensity in the whiter and gray matter areas also were 87.33 $\pm$ 15.24 and 140.66 $\pm$ 13.45 in the gradient echo EPI techniques, The signal intensity of gradient echo EPI showed higher values compared to spin echo EPI. Otherwise, gradient echo EPI technique is distortion enough to operation wound and edge of the image, while spin echo EPI technique did not appear almost. In this point, the spin echo EPI technique, after surgical operation according to patient state beside gradient echo EPI techniques that signalbeside gradient echo EPI techniques that signal intensity is high and patient's case which image distortion is serious by metal etc, will be provide the useful information in adults and pediatric patients.

  • PDF

A Performance Comparison of Histogram Equalization Algorithms for Cervical Cancer Classification Model (평활화 알고리즘에 따른 자궁경부 분류 모델의 성능 비교 연구)

  • Kim, Youn Ji;Park, Ye Rang;Kim, Young Jae;Ju, Woong;Nam, Kyehyun;Kim, Kwang Gi
    • Journal of Biomedical Engineering Research
    • /
    • v.42 no.3
    • /
    • pp.80-85
    • /
    • 2021
  • We developed a model to classify the absence of cervical cancer using deep learning from the cervical image to which the histogram equalization algorithm was applied, and to compare the performance of each model. A total of 4259 images were used for this study, of which 1852 images were normal and 2407 were abnormal. And this paper applied Image Sharpening(IS), Histogram Equalization(HE), and Contrast Limited Adaptive Histogram Equalization(CLAHE) to the original image. Peak Signal-to-Noise Ratio(PSNR) and Structural Similarity index for Measuring image quality(SSIM) were used to assess the quality of images objectively. As a result of assessment, IS showed 81.75dB of PSNR and 0.96 of SSIM, showing the best image quality. CLAHE and HE showed the PSNR of 62.67dB and 62.60dB respectively, while SSIM of CLAHE was shown as 0.86, which is closer to 1 than HE of 0.75. Using ResNet-50 model with transfer learning, digital image-processed images are classified into normal and abnormal each. In conclusion, the classification accuracy of each model is as follows. 90.77% for IS, which shows the highest, 90.26% for CLAHE and 87.60% for HE. As this study shows, applying proper digital image processing which is for cervical images to Computer Aided Diagnosis(CAD) can help both screening and diagnosing.

Implementation of an LFM-FSK Transceiver for Automotive Radar

  • Yoo, HyunGi;Park, MyoungYeol;Kim, YoungSu;Ahn, SangChul;Bien, Franklin
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.4 no.4
    • /
    • pp.258-264
    • /
    • 2015
  • The first 77 GHz transceiver that applies a heterodyne structure-based linear frequency modulation-frequency shift keying (LFM-FSK) front-end module (FEM) is presented. An LFM-FSK waveform generator is proposed for the transceiver design to avoid ghost target detection in a multi-target environment. This FEM consists of three parts: a frequency synthesizer, a 77 GHz up/down converter, and a baseband block. The purpose of the FEM is to make an appropriate beat frequency, which will be the key to solving problems in the digital signal processor (DSP). This paper mainly focuses on the most challenging tasks, including generating and conveying the correct transmission waveform in the 77 GHz frequency band to the DSP. A synthesizer test confirmed that the developed module for the signal generator of the LFM-FSK can produce an adequate transmission signal. Additionally, a loop back test confirmed that the output frequency of this module works well. This development will contribute to future progress in integrating a radar module for multi-target detection. By using the LFM-FSK waveform method, this radar transceiver is expected to provide multi-target detection, in contrast to the existing method.

Effect of High Tube Voltage and Scatter Ray Post-processing Software on Image Quality and Radiation Dose During Chest Anteroposterior Radiography (흉부 전·후방향 검사 시 고관전압 및 산란선 후처리 소프트웨어 적용이 화질과 선량에 미치는 영향)

  • Kim, Jong-Seok;Joo, Young-Cheol;Lee, Seung-Keun
    • Journal of radiological science and technology
    • /
    • v.44 no.4
    • /
    • pp.295-300
    • /
    • 2021
  • This study aims to present new chest AP examination exposure conditions through a study on the effect on image quality and patient dose by applying high tube voltage and scatter ray post-processing software during chest AP examination in digital radiography equipment. This study was used a human body phantom and in the chest AP position, the dosimeter was placed horizontally at the thoracic spine 6. The experiment was conducted by dividing into a low tube voltage (70 kVp, 400 mA, 3.2 mAs) group and a high tube voltage (100 kVp, 400 mA, 1.2 mAs) group. The collimation size (14″× 17″) and the source to image receptor distance(110 cm) were same applied to both groups. Radiation dose was presented to dose area product and entrance surface dose. Image quality was compared and analyzed by comparing the difference between the signal-to-noise ratio and the contrast-to-noise ratio of the image according to the application of the scatter ray post-processing software under each condition. The average value of the entrance surface dose in the low and high tube voltage conditions was 93.04±0.45 µGy and 94.25±1.51 µGy, which was slightly higher in the high tube voltage condition, but the dose area product was 0.97±0.04 µGy and 0.93±0.01 µGy. There was a statistically significant difference in the group mean value(p<0.01). In terms of image quality, the values of the signal-to-noise ratio and the contrast noise ratio were higher in the high tube voltage than in the low tube voltage, and decreased when the scattering line post-processing function was used, but the contrast resolution was improved. If there is a scatter ray post-processing function during chest AP examination, it is helpful to actively utilize it to improve the image quality. However, when this function is not available, I thought that applying a higher tube voltage state than a low tube voltage state will help to realize images with a large amount of information without changing the dose.

A study on characteristics related to texture, colour temperature and contrast ratio to improve the depth of stereoscopic images (깊이감 향상을 위한 질감, 색온도, 대비비 관련 특성 연구)

  • Hong, Ji-Young
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.18 no.4
    • /
    • pp.37-42
    • /
    • 2018
  • With advancements in digital image production technology, the branch of stereoscopic image technology has also been undergoing active development. Accordingly, research and development on cutting-edge display products for mounting stereoscopic images are currently being pursued. There are various problems that can occur when viewing 3D images. Because viewers feel visual fatigue while perceiving the depth of the images provided via an artificial method, a negative human factor such as visual fatigue has become one of the most prominent concerns, especially as it is a factor that affects the ongoing maintenance of 3D images. Therefore, by identifying the factors affecting the depth of the graphic images provided in 2D images, and subsequently using this information to develop an image processing method, we conducted depth-related experiments and analysed them under the assumption that stereoscopic images could be reproduced without visual fatigue. Thus, we analysed the most significant factors related to depth and verified the interactions by performing depth-related factors-based ANOVA variance analysis by differentially applying the texture, colour temperature, and contrast ratio to graphic images. We determined the significance of the factors related to depth and proposed a method to improve depth based on an analysis of the results of the experiments conducted in this study.

A Study on the Certification System for Offline Stores Selling Copyrighted Contents: Copyright OK Case (정품 콘텐츠 판매 오프라인 업체 인증제도 방안 연구: 저작권 OK 사례)

  • Gyoo Gun Lim;Jae Young Choi;Woong Hee Lee
    • Information Systems Review
    • /
    • v.19 no.4
    • /
    • pp.27-42
    • /
    • 2017
  • With the rapid development in network, graphic technology, and digital technology, content industry is emerging as an important industry for new cultural development and economic development. The development in digital content technology has remarkably expanded the generation and distribution of contents, thereby creating new value and extending into a large distribution market. However, the ease of distribution and duplication, which characterizes digital technology, has increased the circulation of illegal contents due to illegal copying, theft, and alteration. The damage caused by this illegal content is severe. Currently, a copyright protection system targeting online sites is available. By contrast, no system has been established for offline companies that sell offline genuine content, which compete with online companies. The demand for content of overseas tourists is increasing due to the Korean wave craze. Nevertheless, many offline content providers have lost competitiveness due to illegal content distribution with online companies. In this study, we analyzed the case and status of similar copyright certification systems in Korea and overseas through previous research and studied a system to certify the offline genuine contents business. In addition to the case analysis, we focused on interviews obtained through in-depth interviews with the copyright stakeholders. We also developed a certification framework by establishing the certification domain, certification direction, and incentive of the certification system for offline businesses with genuine content. Selected certification direction is ethical, open, inward, store, and rigid (post evaluation). This study aimed to increase awareness among consumers about the use of genuine content and establish a transparent trading order in a healthy content market.

Remote Sensing of Surface Films as a Tool for the Study of Oceanic Dynamic Processes

  • Mitnik, Leonid;Dubina, Vyacheslav;Konstantinov, Oleg;Fischenko, Vitaly;Darkin, Denis
    • Ocean and Polar Research
    • /
    • v.31 no.1
    • /
    • pp.111-119
    • /
    • 2009
  • Biogenic surface films, which are often present in coastal areas, may enhance the signatures of hydrodynamic processes in microwave, optical, and infrared imagery. We analyzed ERS-1/2 Synthetic Aperture Radar (SAR) and Envisat Advanced Synthetic Aperture Radar (ASAR) images taken over the Japan/East Sea (JES). We focused on the appearance of the contrast SAR signatures, particularly the dark features of different scales caused by various oceanic and atmospheric phenomena. Spiral eddies of different scales were detected through surface film patterns both near the coast and in the open regions of the JES in warm and cold seasons. During field experiments carried out at the Pacific Oceanological Institute (POI) Marine Station 'Cape Shults' in Peter the Great Bay, the sea surface roughness characteristics were measured during the day and night using a developed polarization spectrophotometer and various digital cameras and systems of floats. The velocity of natural and artificial slicks was estimated using video and ADCP time series of tracers deployed on the sea surface. The slopes of gravity-capillary wave power spectra varied between .4 and .5. Surface currents in the natural and artificial slicks increased with the distance from the coast, varying between 4 and 40 cm/s. The contrast of biogenic and anthropogenic slicks detected on vertical and horizontal polarization images against the background varied over a wide range. SAR images and ancillary satellite and field data were processed and analyzed using specialized GIS for marine coastal areas.