• 제목/요약/키워드: Differential protection

검색결과 215건 처리시간 0.026초

대용량 변압기 보호를 위한 디지털 보호계전기법의 비교 (A Comparative Analysis of Digital Protection Relaying Techniques for Large Transformer)

  • 박철원;박재세;신명철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.135-139
    • /
    • 2003
  • Presented on this paper are state of the art review of transformer protection technique, EMTP modeling, and comparative analysis of improved digital relaying algorithms for differential protection of large transformer.

  • PDF

Differential Privacy in Practice

  • Nguyen, Hiep H.;Kim, Jong;Kim, Yoonho
    • Journal of Computing Science and Engineering
    • /
    • 제7권3호
    • /
    • pp.177-186
    • /
    • 2013
  • We briefly review the problem of statistical disclosure control under differential privacy model, which entails a formal and ad omnia privacy guarantee separating the utility of the database and the risk due to individual participation. It has born fruitful results over the past ten years, both in theoretical connections to other fields and in practical applications to real-life datasets. Promises of differential privacy help to relieve concerns of privacy loss, which hinder the release of community-valuable data. This paper covers main ideas behind differential privacy, its interactive versus non-interactive settings, perturbation mechanisms, and typical applications found in recent research.

전력용 변압기에서 권선방식과 벡터그룹에 따른 보호계전기 동작원리의 그래픽 표현 (Graphical Presentation on Operational Principle of Pretective Relay According to Winding Type and Vector Group in Transformer)

  • 이종범
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권3호
    • /
    • pp.226-233
    • /
    • 1999
  • Protective relay for transformer operates in general by comparing with the differential current and the restraint current. These kinds of currents are changed on magnitude and phasor during the fault according to winding type and vector group. This paper presents the differential and restraint currents and operational principle of differential protective relay for two-winding and three-winding transformer with graphical mode. It is developed using MATLAB for and educational purpose on engineer related in power system and protection in university and power utility including large factory.

  • PDF

Method to Prevent the Malfunction Caused by the Transformer Magnetizing Inrush Current using IEC 61850-based IEDs and Dynamic Performance Test using RTDS Test-bed

  • Kang, Hae-Gweon;Song, Un-Sig;Kim, Jin-Ho;Kim, Se-Chang;Park, Jong-Soo;Park, Jong-Eun
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권3호
    • /
    • pp.1104-1111
    • /
    • 2014
  • The digital substations are being built based on the IEC 61850 network. The cooperation and protection of power system are becoming more intelligent and reliable in the environment of digital substation. This paper proposes a novel method to prevent the malfunction caused by the Transformer Magnetizing Inrush Current(TMIC) using the IEC 61850 based data sharing between the IEDs. To protect a main transformer, the current differential protection(87T) and over-current protection(50/51) are used generally. The 87T IED applies to the second harmonic blocking method to prevent the malfunction caused by the TMIC. However, the 50/51 IED may malfunction caused by the TMIC. To solve that problem, the proposed method uses a GOOSE inter-lock signal between two IEDs. The 87T IED transmits a blocking GOOSE signal to the 50/51 IED, when the TMIC is detected. The proposed method can make a cooperation of digital substation protection system more intelligent. To verify the performance of proposed method, this paper performs the real time test using the RTDS (Real Time Digital Simulator) test-bed. Using the RTDS, the power system transients are simulated, and the TMIC is generated. The performance of proposed method is verified in real-time using that actual current signals. The reaction of simulated power system responding to the operation of IEDs can be also confirmed.

Wibro 기반 비행기지 방어전력 위치식별체계 구축 및 실험 (Implementation and Evaluation of the Wibro-based Location Identification System for Air Base Protection Force)

  • 표상호;구정;고영배;김기형
    • 한국군사과학기술학회지
    • /
    • 제15권3호
    • /
    • pp.306-314
    • /
    • 2012
  • This paper proposes a new system to maximize efficiency of Air Base Protection Operations through the development of location identification software. The Wibro-based location identification system for Air Base Protection Force offers Blue Ground Force digitalized character message which is not exposed to enemy. Also, it is possible to automatically provide the location of Blue Ground Force to Air Base Ground Operations Center. The test result proves that this system is very helpful when Air Base Protection Force executes Air Base Protection Operations.

DIFFERENTIAL EXPRESSION OF RADIATION RESPONSE GENES IN SPLEEN, LUNG, AND LIVER OF RATS FOLLOWING ACUTE OR CHRONIC RADIATION EXPOSURE

  • Jin, Hee;Jin, Yeung Bae;Lee, Ju-Woon;Kim, Jae-Kyung;Lee, Yun-Sil
    • Journal of Radiation Protection and Research
    • /
    • 제40권1호
    • /
    • pp.25-35
    • /
    • 2015
  • We analyzed the differential effects of histopathology, apoptosis and expression of radiation response genes after chronic low dose rate (LDR) and acute high dose rate (HDR) radiation exposure in spleen, lung and liver of rats. Female 6-week-old Sprague-Dawley rats were used. For chronic low-dose whole body irradiation, rats were maintained for 14 days in a $^{60}Co$ gamma ray irradiated room and received a cumulative dose of 2 Gy or 5 Gy. Rats in the acute whole body exposure group were exposed to an equal dose of radiation delivered as a single pulse ($^{137}Cs$-gamma). At 24 hours after exposure, spleen, lung and liver tissues were extracted for histopathologic examination, western blotting and RT-PCR analysis. 1. The spleen showed the most dramatic differential response to acute and chronic exposure, with the induction of substantial tissue damage by HDR but not by LDR radiation. Effects of LDR radiation on the lung were only apparent at the higher dose (5 Gy), but not at lower dose (2 Gy). In the liver, HDR and LDR exposure induced a similar damage response at both doses. RT-PCR analysis identified cyclin G1 as a LDR-responsive gene in the spleen of rats exposed to 2 Gy and 5 Gy gamma radiation and in the lung of animals irradiated with 5 Gy. 2. The effects of LDR radiation differed among lung, liver, and spleen tissues. The spleen showed the greatest differential effect between HDR and LDR. The response to LDR radiation may involve expression of cyclin G1.

오차를 고려한 765kV 변압기 보호 계전 정정룰 고찰 (Investigation into Transformer Protective Relay Setting Rule Considering Error Ratio)

  • 배영준;이승재;최면송;강상희;김상태;최정이;정창현;유영식;조범섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 A
    • /
    • pp.229-231
    • /
    • 2002
  • The digital current differential relaying scheme is widely used for primary protection of 765(kV) power transformer. The current differential relay pickup the internal fault at the threshold which is set at 30% of rating current. Margin of 30% include current transformer error 5%, relay error 5%, on load tap changer error 7% and margin factor 140% obtained from the field experience. In this paper transformer protection relay and relay setting rule of high voltage power system are discussed. And we verify the correctness of relay setting rule with current differential relay using Matlab simulation.

  • PDF

모선보호용 디지털계전기의 고장분석 프로그램의 구현 (A Fault Analysis Program for a Digital Bus Protection Relay)

  • 손천명;강상희;이승재;안용진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.246-248
    • /
    • 2001
  • In this paper, the fault analysis program that is convenient to analyse fault records of a digital relay and to set a digital relay is described. The key feature of this fault analysis program is as follows. - analysing fault records stored in a local PC and/or a digital relay - analysing events - setting a digital relay. This program is for a digital bus protection relay using a conventional variable percentage current differential relaying algorithm. So this program adds a function analysing the characteristic of each variable percentage current differential function and the connection state of the transmission lines at double-bus system.

  • PDF

잔류자속에 무관한 보상 알고리즘을 적용한 모선보호용 전류차동 계전방식 (A Percentage Current Differential Relay for Bus Protection Using a Compensation Algorithm Unaffected by a Remanent Flux)

  • 강용철;윤재성;임의재
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.308-310
    • /
    • 2003
  • This paper proposes a percentage current differential relaying algorithm for bus protection with a compensation algorithm of a CT. The compensating algorithm estimates the core flux at the start of the first saturation based on the value of the third-difference of the secondary current. It calculates the core flux and compensates distorted currents in accordance with the magnetization curve. The test results indicate that the algorithm can discriminate internal faults from external faults when the CT saturates. It can improve not only stability of the relay in the case of an external fault but sensitivity of the relay in the case of an internal fault.

  • PDF

지능형기법을 이용한 변압기의 디지털 차동보호 (Digital Differential Protection of Transformer using Intelligent Schemes)

  • 박철원;정호성;신명철;이복구;서희석;윤석무;이춘모
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 G
    • /
    • pp.2281-2283
    • /
    • 1998
  • In this paper, we propose a digital differential protection of power transformer using intelligent schemes. Intelligent schemes is based on fuzzy logic and neural networks. To enhance the distinction between fault and inrush of conventional approaches, relaying technique by fuzzy logic and neural networks are used. We used transformer inrush currents, external and internal fault signals, which are obtained from EMTP simulation.

  • PDF