• 제목/요약/키워드: Differential pressure transducer

검색결과 22건 처리시간 0.028초

수직관에서 2상선회유동이 보이드분포와 압력강하에 미치는 영향 (The Effects of Two - Phase Swirling Flow on Void Distribution and Pressure Drop in a Vertical Tube)

  • 김인석;손병진;신현동;곽기태
    • 설비공학논문집
    • /
    • 제1권2호
    • /
    • pp.190-201
    • /
    • 1989
  • This experimental investigation has been conducted to determine the effects of swirling angle and flow patterns on distributions of void fraction, bubble velocity and two-phase pressure drop in a vertical straight tube. Swirling angles of $0^{\circ}$ (non swirling), $30^{\circ}$, and $45^{\circ}$ were tested with air-water two components over a range of superficial air velocities. A transparent lucite tube of 38mm in internal diameter was used for the test section. The void fraction and bubble velocities were measured by means of a optical fiber probe at the upper part of the swirler in the test section. Pressure drops which seem to be closely related with flow patterns and swirling angle were measured by a differential pressure transducer. It is shown that the probability density functions of pressure drop demonstrate peculiar features for both swirling angles and flow patterns, whereas the distributions of void fraction and bubble velocities are parabolic and flat shape in the vicinity of tube center, respectively except bubbly flow in any swirling angle cases, and the void fraction increases with increasing swirling angle around the center of tube.

  • PDF

적혈구 변형성의 측정과 혈액 점도와의 상관관계 연구 (Measurements of RBC deformability and its effect on blood viscosity)

  • 구윤희;박명수;신세현
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.1682-1686
    • /
    • 2004
  • A slit-flow apparatus with laser diffraction method has been developed with significant advances in ektacytometry design, operation and data analysis. In the slit-flow ektacytometry (or laser-diffractometry), the deformation of red blood cells subjected to continuously decreasing shear stress in slit flow is measured. A laser beam traverses a diluted blood suspension flowing through a slit and is diffracted by RBCs in the volume. The diffraction patterns are captured by a CCD-video camera, linked to a frame grabber integrated with a computer, while the differential pressure variation is measured by a pressure transducer. Both measurements of laser-diffraction image and pressure with respect to time enable to determine deformation index and the shear stress. The range of shear stress of 0 ${\sim}$ 35 Pa and measuring time is less than 2 min. When deforming under decreasing shear stress, RBCs change gradually from the prolate ellipsoid towards a circular biconcave morphology. The Deformation Index (DI) as a measure of RBC deformability is determined from an isointensity curve in the diffraction pattern using an ellipse-fitting program. The advantages of this design are simplicity, i.e., ease of operation and no moving parts, low cost, short operating time, and the disposable kit which is contacted with blood sample.

  • PDF

유동층 연소로에서 진동형 공급기의 고체혼합 및 충전물에 대한 압력요동 특성 (The Characteristics of Solid Mixing in a Vibrating Type Feeder and Pressure Fluctuation of Packing Materials for a Fluidized Bed Combustor)

  • 김미영;김의식
    • 한국안전학회지
    • /
    • 제14권3호
    • /
    • pp.101-109
    • /
    • 1999
  • This study attempts to analyse the solid mixing in the feeder and the packing effect for pressure fluctuations in the fluidized bed. To study the mixing characteristics of solid in vibrating feeder for the stable operations of fluidized combustion, the system consisted of two groups of particles such that fine particles were located on the top of the coarse particles before vibratory mixing had started. The effects of packing materials on the pressure fluctuations in a fluidized bed were analysed by using a statistical method to interpret the behavior of fluidized bed. The experiments were carried out in a fluidized bed of 6.7cm-ID, and the experimental variables were particle sizes, of 115 to 1,015$\mu\textrm{m}$ in diameter and the multi-sized particles haying Rosin-Rammler and Gaussian distributions. The settled bed heights of particles to diameter ratios (L/D) were ranged from 0.5 to 2.0. And fluidizing of particles was carried out by air. The packing materials used were screen packing, and the properties of the pressure fluctuations in the fluidized bed were measured by a differential pressure transducer. The properties of the pressure fluctuations calculated were the mean, the standard deviation, and the major frequency of the power spectral density functions. From the characteristics of fluidizing, it was found that the standard deviation of pressure fluctuations could be effectively used to explain the fluidized phenomena, and the packing materials affected severely the properties of the pressure fluctuations. As a result, from the interpretation by spectral analysis, the effects of measuring radius of pressure fluctuations on standard deviation were constant in the case of the fluidized bed with and without packing materials. However, the effects of measuring the height of pressure fluctuations on standard deviations were linear increasing for the fluidized bed with packing materials, but were constant for the fluidized bed without packing materials at 4.5cm above the gas distributor. The major frequency of pressure fluctuations was found to be nearly independent of fluidized system. Also, the major frequency of pressure fluctuations decreased with increasing packing size, and it had maximum value at 10% of the packing amount.

  • PDF

후두기능 진단을 위한 음성 및 유체역학적 측정장치 개발 (Speech and Aerodynamics Measurement System for Laryngeal Function Assessment)

  • 이재성;박광석;성명훈;김광현
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1996년도 추계학술대회
    • /
    • pp.37-39
    • /
    • 1996
  • For the laryngeal function assessment, we developed a measurement system of speech sound and air flow rate. The speech sound was transduced with a standard omnidirectional condenser microphone and orally emitted air flow was measured with pneumotachometer using differential pressure transducer.

  • PDF

CFD ANALYSIS OF HEAVY LIQUID METAL FLOW IN THE CORE OF THE HELIOS LOOP

  • Batta, A.;Cho, Jae-Hyun;Class, A.G.;Hwang, Il-Soon
    • Nuclear Engineering and Technology
    • /
    • 제42권6호
    • /
    • pp.656-661
    • /
    • 2010
  • Lead-alloys are very attractive nuclear coolants due to their thermo-hydraulic, chemical, and neutronic properties. By utilizing the HELIOS (Heavy Eutectic liquid metal Loop for Integral test of Operability and Safety of PEACER$^2$) facility, a thermal hydraulic benchmarking study has been conducted for the prediction of pressure loss in lead-alloy cooled advanced nuclear energy systems (LACANES). The loop has several complex components that cannot be readily characterized with available pressure loss correlations. Among these components is the core, composed of a vessel, a barrel, heaters separated by complex spacers, and the plenum. Due to the complex shape of the core, its pressure loss is comparable to that of the rest of the loop. Detailed CFD simulations employing different CFD codes are used to determine the pressure loss, and it is found that the spacers contribute to nearly 90 percent of the total pressure loss. In the system codes, spacers are usually accounted for; however, due to the lack of correlations for the exact spacer geometry, the accuracy of models relies strongly on assumptions used for modeling spacers. CFD can be used to determine an appropriate correlation. However, application of CFD also requires careful choice of turbulence models and numerical meshes, which are selected based on extensive experience with liquid metal flow simulations for the KALLA lab. In this paper consistent results of CFX and Star-CD are obtained and compared to measured data. Measured data of the pressure loss of the core are obtained with a differential pressure transducer located between the core inlet and outlet at a flow rate of 13.57kg/s.

Computerized spirometer의 개발 (Development of Computerized Spirometer)

  • 차은종;박인석;송춘희;김도우;구용숙;이태수
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1996년도 추계학술대회
    • /
    • pp.189-191
    • /
    • 1996
  • Computerized spirometer was developed in a form of proto type system. The system consisted of pneumotachometer, flow measurement unit, fan ventilator unit, and software program. Patient's respiratory flow signal was first converted to corresponding pressure drop signal by a screen type pneumotachometer, sensed by a differential pressure transducer, amplified and low pass filtered, and digitized at a rate of 100 Hz, then fed into a PC thru RS-232C serial port. Customized application software controls data acquisition followed by computation of test parameters. The fan ventilator unit dries and eliminates microorganism in the pneumotachometer after each test. The system performs conventional spirometic tests and manages the test results in a database for retrograde research. The proto type system was fully developed and the commercialized system is currently being built up.

  • PDF

기체-고체 유동층에서 Chaos 파라메타에 의한 흐름영역의 해석 (Analysis of Flow Regimes by Using Chaos Parameters in Gas-Solid Fluidized Beds)

  • 송평섭;최왕규;정종헌;오원진;강석환;손성모;강용
    • 공업화학
    • /
    • 제17권1호
    • /
    • pp.93-99
    • /
    • 2006
  • 기체-고체 유동층 시스템에서 유동화 흐름영역을 결정할 수 있는 방법들에 대하여 고찰하였다. 기체-고체 시스템의 흐름영역 해석을 위한 상태변수로 상승관내에서의 압력요동을 측정하여 유동화 흐름영역을 해석하였으며, 차압변환기로부터 얻은 압력요동의 자료를 기존의 방법인 평균 및 표준편차를 사용하여 해석하였을 뿐만 아니라, 상관차원이나 Kolmogorov 엔트로피와 같은 chaos 해석 방법을 이용하여 기체-액체 유동층에서 흐름영역을 고찰하였다. 그 결과, 기체-고체 유동층에서 유동화 영역은 평균과 표준편차와 같은 통계적 방법에 의해 결정할 수 있었을 뿐만 아니라, 상관차원과 Kolmogorov 엔트로피와 같은 Chaos 해석방법으로도 유동화영역을 구별할 수 있는 특성으로 사용할 수 있었다.

침투압을 이용한 급속압밀시험 : 방법 및 검증 (Fast Consolidation Test Using Seepage Forces : Method and Validation)

  • 이강일;김태형;도브로슬리브지니다르씨스
    • 한국지반공학회논문집
    • /
    • 제25권4호
    • /
    • pp.31-38
    • /
    • 2009
  • 최근의 압밀시험(표준압밀시험 또는 자중압밀시험)을 대신하여 성형되는 않은(또는 성형이 불가능한 상태의) 연약한 흙의 압밀거동을 연속적으로 빠르고 편리하게 결정할 수 있는 실험방법이 요구된다. 그래서 본 연구에서는 이와 같은 흙의 압밀 거동을 플로우 펌프에서 발생된 침투압을 이용하여 연속적으로 빠르게 획득할 수 있는 급속압밀실험을 제안하였다. 실험 장치는 삼축셀, 플로우 펌프, 변환기, 데이터처리장치 등으로 구성되고, 실험의 과정은 동일 시료에 대해 침투압에 의한 압밀, 하중재하에 의한 압밀, 압밀 후 투수시험 순으로 연속적으로 진행된다. 또한 본 실험법의 검증을 위해 기존의 표준압밀시험으로부터 얻은 결과와 비교 검토도 이루어졌다. 연구 결과 급속압밀실험법이 연약한 흙의 압밀 침하량 산정에 필요한 데이터를 쉽고 빠르게 산정할 수 있는 방법임을 알 수 있었다.

3D 프린터 마이크로채널 제작 및 액상 물의 압력강하 특성에 관한 연구 (Liquid Flow Characteristics in 3D-Printed Rectangular Microchannel)

  • 박재현;박희성
    • 대한기계학회논문집B
    • /
    • 제41권1호
    • /
    • pp.69-74
    • /
    • 2017
  • 마이크로채널은 단위체적당 표면적비가 높기 때문에 컴퓨터 마이크로 프로세서 냉각, 정밀 화학분석 및 바이오 분야로의 응용이 다양하게 적용 될 수 있어 많은 연구가 진행 중이다. 본 연구에서는 3D 프린터를 이용하여 사각 마이크로채널을 제작하였고, 실험에서 마이크로채널을 통과하는 액상 물은 탈이 온수를 사용하여 유량변화에 대한 압력강하를 측정하였다. 마이크로채널의 크기는 $161{\mu}m$에서 $664{\mu}m$로 변화시켜 제작하였으며, 유동의 레이놀즈 수는 16

무선센서 네트워크 기술 기반 액화가스 저장탱크 내 잔량 모니터링 시스템 구현 (Implementation of a Residual Quantity Monitoring System in a Liquefied Gas Storage Tank based on Wireless Sensor Network Technology)

  • 김민규;한해진;한재환
    • 센서학회지
    • /
    • 제27권5호
    • /
    • pp.352-356
    • /
    • 2018
  • This paper relates to a technology for monitoring a liquefied gas storage tank in the special gas field where demand is increasing owing to the continuous growth of related fields such as the semiconductor, display, and ICT convergence electronics industries. We have proposed a system for real - time monitoring using wireless sensor network technology, and implemented a system consisting of a sensor unit, transmitter module, and receiver module to be attached to a liquefied gas storage tank. The system was applied to LCO2 tanks among various liquefied gas storage tanks to verify the feasibility. The storage tanks employed in the experiments has capacities of 16,179 l and was 1,920 mm in inner diameter. Furthermore, the density was 1.03 g/l. The measured data were compared with reference data on the remaining gas level versus the $CO_2$ height of the surface, expressed using a conventional water meter, provided by an existing storage tank supplier. The experimental results show that the data is similar to the standard data provided by the tank supplier, and has a high accuracy and reliability within an error range of 0.03%.