• Title/Summary/Keyword: Different Thickness

Search Result 4,569, Processing Time 0.031 seconds

Minimum Thickness of RC Bridge Slab Considering Fatigue and Serviceability (피로강도와 사용성을 고려한 RC 바닥판의 최소두께)

  • Hwang Hoon Hee;Joh Changbin;Kim Byung Suk;Jung Chul Hun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.05a
    • /
    • pp.248-251
    • /
    • 2004
  • This study was performed to propose the minimum thickness of RC slab that satisfies constructibility, fatigue safety, and serviceability requirements such as deflection control. Three different minimum thicknesses are calculated using concrete shear and rebar fatigue formulas, and deflection control, respectively, and checked by constructiblity. The maximum of these three minimum thicknesses is proposed as the minimum thickness of RC slab, which shows that the minimum thickness requirement of RC slab from Korean Bridge Design Code can be thinner than now.

  • PDF

A Study on Changes in Biomechanical Characteristics of the Foot with Respect to Wedge-type Insole Thickness (키높이 인솔두께에 따른 족부의 생체역학적 특성변화에 대한 연구)

  • Park, T.H.;Jung, T.G.;Han, D.W.;Lee, Sung-Jae
    • Journal of Biomedical Engineering Research
    • /
    • v.34 no.2
    • /
    • pp.80-90
    • /
    • 2013
  • Recently, functional insoles of wedge-type it is for the young to raise their height inserted between insole and heel cause foot pain and disease. Additionally, these have a problem with stability and excessively load-bearing during gait like high-heel shoes. In this study, we compared the changes in biomechanical characteristics of foot with different insole thickness then we will utilize for the development of the insole with the purpose of relieving the pain and disease. Subjects(male, n = 6) measured COP(center of pressure) and PCP(peak contact pressure) on the treadmill(140cm/s) using F-scan system and different insole thickness(0~50 mm) between sole and plantar surface during gait. Also, we computed changes of stresses at the foot using finite element model with various insole thickness during toe-off phase. COP moved anterior and medial direction and, PCP was increased at medial forefoot surface, $1^{st}$ and $2^{nd}$ metatarsophalangeal, ($9%{\uparrow}$) with thicker insoles and it was show sensitive increment as the insole thickness was increased from 40 mm to 50 mm. Change of the stress at the soft-tissue of plantar surface, $1^{st}$ metatarsal head represents rapid growth($36%{\uparrow}$). Also, lateral moments were increased over the 100% near the $1^{st}$ metatarsal as the insole thickness was increased from 0 mm to 30 mm. And it is show sensitive increment as the insole thickness changed 10 mm to 20 mm. As a result, it was expected that use of excessively thick insoles might cause unwanted foot pain at the forefoot region. Therefore, insole thickness under 30 mm was selected.

Comparison of the Thickness of the Neck Flexor Muscles of Subjects With and Without a Forward Head Posture on the Two Initial Head Positions During Cranio-Cervical Flexion Exercise

  • Jung, Sung-hoon;Kwon, Oh-yun;Choi, Kyu-hwan;Ha, Sung-min;Kim, Su-jung;Jeon, In-cheol;Hwang, Ui-jae
    • Physical Therapy Korea
    • /
    • v.22 no.4
    • /
    • pp.44-50
    • /
    • 2015
  • This study compared the effects of the initial head position (i.e., a HHP versus a relaxed head position) of subjects with and without a FHP on the thickness of the deep and superficial neck flexor muscles during CCF. The study recruited 6 subjects with a FHP and 10 subjects without a FHP. The subjects performed CCF in two different head positions: a HHP, with the head aligned so that the forehead and chin formed a horizontal line, and a relaxed head position (RHP), with the head aligned in a self-selected comfortable position. During the CCF exercise, the thickness of the longus colli (LCo) and the thickness of the sternocleidomastoid (SCM) were recorded using ultrasonography. The thickness of each muscle was measured by Image J software. The statistical analysis was performed with a two-way mixed-model analysis of variance. The thickness of the SCM differed significantly (p<.05) between the subjects with and without FHP. According to a post $h^{\circ}C$ independent t-test, the change in thickness of the SCM increased significantly during CCF in the subjects with FHP while adopting a HHP compared to that in the subjects without FHP. The change in thickness of the SCM was not significantly different between the two positions in subjects without FHP, and there was no significant change in thickness of the LCo muscle during the CCF exercise according to the initial position in both subjects with and without FHP. The results suggest that CCF should be performed in RHP to minimize contraction of the SCM in subjects with a FHP.

Effects of thin-film thickness on device instability of amorphous InGaZnO junctionless transistors (박막의 두께가 비정질 InGaZnO 무접합 트랜지스터의 소자 불안정성에 미치는 영향)

  • Jeon, Jong Seok;Jo, Seong Ho;Choi, Hye Ji;Park, Jong Tae
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.9
    • /
    • pp.1627-1634
    • /
    • 2017
  • In this work, a junctionless transistor with different film thickness of amorphous InGaZnO has been fabricated and it's instability has been analyzed with different film thickness under positive and negative gate stress as well as light illumination. It was found that the threshold voltage shift and the variation of drain current have been increased with decrease of film thickness under the condition of gate stress and light illumination. The reasons for the observed results have been explained by stretched-exponential model and device simulation. Due to the reduced carrier trapping time with decrease of film thickness, electrons and holes can be activated easily. Due to the increase of vertical channel electric field reaching the back interface with decrease of film thickness, more electrons and holes can be accumulated in back interface. When one decides the film thickness for the fabrication of junctionless transistor, the more significant device instability with decrease of film thickness should be consdered.

Estimation of Empirical Fatigue Crack Propagation Model of AZ31 Magnesium Alloys under Different Specimen Thickness Conditions (AZ31 마그네슘합금의 시편두께 조건에 따른 실험적 피로균열전파모델 평가)

  • Choi, Seon Soon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.2
    • /
    • pp.646-652
    • /
    • 2014
  • It is the primary aim of this paper to propose the empirical fatigue crack propagation model fit to describe a crack growth behavior of AZ31 magnesium alloys under the different specimen thickness conditions. The empirical models estimated are Paris-Erdogan model, Walker model, Forman model, and modified-Forman model. The parameters of each model are estimated by maximum likelihood method. The statistical crack growth data needed for an estimation of empirical models are obtained by fatigue crack propagation tests under the three cases of specimen thickness. It is found that the good empirical models fit to describe a crack growth behavior of AZ31 magnesium alloys under the different specimen thickness conditions are Paris-Erdogan model and Walker model. It is also verified that a fatigue crack growth rate exponent of a empirical model may be a material constant at the specimen thickness conditions of 4.75mm and 6.60mm.

Comparison of Tibialis Anterior Muscle Thickness with 4 Different Toe and Ankle Postures: Ultrasonographic Study

  • Jang, Tae-Jin;Hwang, Byeong-Hun;Jeon, In-Cheol
    • The Journal of Korean Physical Therapy
    • /
    • v.34 no.1
    • /
    • pp.12-17
    • /
    • 2022
  • Purpose: Ankle dorsiflexion is an essential element of normal functions, including walking, activities of daily living and sport activities. The tibialis anterior (TA) muscle functioned as a dorsiflexor and as a dynamic stabilizer of the ankle joint during walking and jumping. This study aimed to compare TA muscle thickness using ultrasonography according to the four different toe and ankle postures for the selective TA strengthening exercise. Methods: This study were recruited 26 (males: 15, females: 11) aged 20-30 years, with no injury ankle and calf in the medical history, had normal dorsiflexion and inversion range of motion (ROM). The thickness of the TA muscle was measured by ultrasonography in the four different toe and ankle postures: 1. Ankle dorsiflexion with all toe extension and ankle inversion (ITEDF); 2. Ankle dorsiflexion with all toe flexion and ankle inversion (ITFDF); 3. Ankle dorsiflexion with all toe extension and neutral position (NTEDF); 4. Ankle dorsiflexion with all toe flexion and neutral position (NTFDF). One-way repeated analysis of variance (ANOVA) and Bonferroni correction were used to confirm the significant difference among conditions. The level of statistical significance was set at α=0.01. Results: TA muscle thickness with ITFDF was significantly greater than in any other ankle positions, including ITEDF, NTFDF, and NTEDF (p<0.01). Conclusion: Among the four toe and ankle postures, isometric contraction in ITFDF postures showed the greatest increase in thickness of TA rather than ITEDF, NTEDF, and NTFDF postures. Based on these results, ITFDF can be recommended in an efficient way to selectively strengthen TA muscle.

Improvement for Recoating Process of Stereolithography System (광조형 시스템의 리코팅 공정 개선)

  • 이은덕;심재형;안규환;백인환
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.12 no.1
    • /
    • pp.16-23
    • /
    • 2003
  • Keeping the layer thickness constant is very essential for improving the shape accuracy in the stereolithography process. The layer thickness is created by recoating process, and also affected by recoating parameters such as blade speed and thickness. The created layer in this process can determine the whole accuracy of the entire parts. The aim of this paper is to improve the accuracy of the layer thickness by adjusting the recoating process parameters. Several experiments with different recoating conditions are Performed to find the optimal recoating parameters that produce the most accurate layer thickness. The effective recoating method is suggested by measuring and analyzing the cured layer thickness.

A Study on the Optimized Copper Electrochemical Plating in Dual Damascene Process

  • Yoo, Hae-Young;Chang, Eui-Goo;Kim, Nam-Hoon
    • Transactions on Electrical and Electronic Materials
    • /
    • v.6 no.5
    • /
    • pp.225-228
    • /
    • 2005
  • In this work, we studied the optimized copper thickness in Cu ECP (Electrochemical Plating). In order to select an optimized Cu ECP thickness, we examined Cu ECP bulge (bump, hump or over-plating amount), Cu CMP dishing and electrical properties of via hole and line trench over dual damascene patterned wafers split into different ECP Cu thickness. In the aspect of bump and dishing, the bulge increased according as target plating thickness decreased. Dishing of edge was larger than center of wafer. Also in case of electrical property, metal line resistance distribution became broad gradually according as Cu ECP thickness decreased. In conclusion, at least $20\%$ reduced Cu ECP thickness from current baseline; $0.8\;{\mu}m$ and $1.0\;{\mu}m$ are suitable to be adopted as newly optimized Cu ECP thickness for local and intermediate layer.

Measurement of two dimensional oil film thickness in piston by induced fluorescence method (유기형광법을 이용한 피스톤 유막두께의 이차원적 측정)

  • 민병순;최재권
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1998.10a
    • /
    • pp.166-174
    • /
    • 1998
  • The distribution of oil film thickness in piston were measured by induced fluorescence method. A Xe lamp was used as light source. Coumarine-6 was mixed with oil as the fluorescent dye. Fluorescent signal which is proportional to the oil film thickness was acquired by CCD camera and transmitted to the personal computer as video signal. In order to solve the problem of measurement system, irregular distribution and unstability of light intensity, as well as to know the relationship between the oil film thickness and output signal, three different calibration techniques were used. Motoring and firing tests were performed in a single cylinder research engine with transparent liner. By analyzing the oil film thickness converted from the photographed image, it was observed that each of three piston rings scrapes the oil both upward and downward and oil film thickness is not uniform horizontally at a given piston land. The amount of oil in each land was considerably affected by the engine load. It is thought that the blow-by gas blows the oil down to the crankcase.

  • PDF

Effect of coating thickness on contact fatigue and wear behavior of thermal barrier coatings

  • Lee, Dong Heon;Jang, Bin;Kim, Chul;Lee, Kee Sung
    • Journal of Ceramic Processing Research
    • /
    • v.20 no.5
    • /
    • pp.499-504
    • /
    • 2019
  • The effect of coating thickness on the contact fatigue and wear of thermal barrier coatings (TBCs) are investigated in this study. The same bondcoat material thickness (250 ㎛) are used for each sample, which allows the effect of the coating thickness of the topcoat to be investigated. TBCs with different coating thicknesses (200, 400, and 600 ㎛) are prepared by changing processing parameters such as the feeding rate of the feedstock, spraying speed, and spraying distance during APS(air plasma spray) coating. The damage size on the surface are strongly affected by the coating thickness effect. Although the damage size from contact fatigue using a spherical indenter diminish at a TBC of 200 ㎛, a high wear resistance such as a low friction coefficient and little mass change are found at a TBC of 600 ㎛. These results indicate that the coating thickness strongly affects the mechanical behavior in TBCs during gas turbine operation.