• Title/Summary/Keyword: Dielectric measurement

Search Result 537, Processing Time 0.022 seconds

Effect of Measuring Method on the Evaluation of Piezoelectric and Dielectric Properties of PMN-PT Single Crystal (PMN-PT 단결정의 압전 및 유전 특성 평가에 미치는 측정 방법의 영향)

  • Kim, Yong Soo;Park, Jae Hwan;Lee, Jeongho;Lee, Sang Goo
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.26 no.4
    • /
    • pp.69-74
    • /
    • 2019
  • The influence of measuring fixtures on the measurement of dielectric and piezoelectric properties of PMN-PT single crystal specimens was investigated. As the pressure of the jig pin which applied the AC electrical signal to the sample decreased, the lower resonance resistance was measured and the higher mechanical quality factor was calculated. The mechanical quality factor was 418 when the spring tension of the jig pin was 20grf, and the value of the quality factor was reduced by half when the spring tension was 200grf. The 4-probe fixture method is unsuitable for measuring piezoelectric properties, but it was suitable for the measurement of dielectric loss. In order to accurately evaluate the piezoelectric properties of PMN-PT, it is necessary to lower the spring tension of the jig pin as much as possible.

Specular Reflectance Measurements of Dielectric Plates in Millimeter Frequency Range

  • Kang, Jin-Seob;Kim, Jeong-Hwan;Kang, Kwang Yong;Yoon, Dae Hwan;Park, Sung Won
    • Journal of electromagnetic engineering and science
    • /
    • v.18 no.2
    • /
    • pp.78-87
    • /
    • 2018
  • This paper describes specular reflectance measurements of dielectric plates in three waveguide frequency bands: D-band (110-170 GHz), G-band (140-220 GHz), and J-band (220-325 GHz). The transmit (Tx) part of the proposed specular reflectance measurement system is stationary, while the receive (Rx) part and the material under test (MUT) holder are concentric-rotating with a 2:1 speed ratio for specular reflectance measurements. In specular reflectance measurements, the first step measures the specular reflection coefficients of an MUT and a metal plate on the MUT holder located at the center of the Tx and Rx parts, and the second step calculates the specular reflectance defined by the specular reflection power (i.e., intensity) of the MUT normalized to that of the metal plate. Multiple reflection effects between the Tx and Rx antennas and the MUT on the measured specular reflectance are minimized by averaging out the multiple specular reflectances measured with changing the separation distance between the two antennas by ${\lambda}/8$ intervals. Measurement results of the perpendicular-polarized specular reflectance of commonly used dielectric plates are verified by comparing those with the analytic results and show that the results measured over the overlapped frequency range of the D-/G-bands and at the boundary frequency of the G-/J-bands agree well with the results for the other band, respectively.

Feasibility Study of Parallel- Plate Detector Using Dielectric film for 6 MV X-ray (6MV X-선 검출특성 조사를 위하여 유전체 필름을 이용하여 제작한 평행판 검출기의 유용성)

  • 조문준;김용은;이병용;김정기;임상욱;김현수;김기환
    • Progress in Medical Physics
    • /
    • v.15 no.2
    • /
    • pp.105-111
    • /
    • 2004
  • The parallel plate detector with dielectric film for dosimetry was designed to measure detection characteristic of 6 MV X-ray with medical linear accelerator. PTFE film was inserted into FEP films that are made by two one-side metal coated materials for ion source. The thicknesses of PTFE dielectric film was 100 ${\mu}{\textrm}{m}$ and the thickness of FEP dielectric film was 100 ${\mu}{\textrm}{m}$, respectively. This detector was fixed by two acrylic plate for physical hardness ad geometrical consistency. The geometrical condition for measurement with parallel-plate for detector was below; SSD=100 cm and the 5 cm depth between detector and phantom surface The major parameter of detector characteristics such as zero drift current, leakage current, charge response by applied voltage, reproducibility, linearity, TMR measurement, dose rate effect were measured. The zero drift currents are 8.3 pA and leakage currents are 10 pA. The charge response of applied voltage is showing linearity in 414 voltage. The measurement deviation of reproducibility in this detector is within 1% for dose and the linearity of applied dose shows in this detector. The TMR curves in phantom between this parallel plate detector and reference detector are matched within 3% deviation from maximum dose depth to 7.5 cm depth. It is considered that this dosimetric system is satisfactory for the purpose of the constancy check of the 6 MV x-ray from medical linear accelerator.

  • PDF

Basic Investigation for the Won-invasive Measurement of Blood Glucose Concentrations by Millimeter Waves (밀리미터파를 이용한 무혈 혈당 측정에 관한 기초 연구)

  • Kim Dong Kyun;Won Jong Hwa;Potapov Sergey N.;Meriakri Viacheslav V.;Chigryai Evgenii E.
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.42 no.1
    • /
    • pp.39-45
    • /
    • 2005
  • As a basic research for the development of a non-invasive blood glucose sensor using millimeter waves, we have presented a method for measuring the dielectric properties of high loss dielectrics, based on the reflection method, and investigated the variation of the dielectric properties of glucose-water and glucose -0.9% NaCl solutions in the 10~90 GHz range. In the proposed method, a minimal reflection condition is formed by placing a specially-chosen low-loss plane-parallel plate in front of a high-loss medium under test at a given frequency range. Using the minimal power reflection coefficient and the corresponding frequency at this condition, tile dielectric properties of the medium can be determined. The measured results on pure water have shown the adequacy of the proposed method. The measured results on glucose-water and glucose -0.9% NaCl solutions in the 10~90 GHz range showed that the variations of the dielectric properties of glucose solutions according to the change of their glucose concentration were maximum in the 30~45 GHz range. From these facts we concluded that the variation of about 3 mole/L in the glucose solutions must be distinguished With the measurement accuracies of ±0.1 dB and ±0.01 GHz.

A Study on Deterioration Measurement Sensor in the Automobile Engine Oil (자동차용 엔진오일의 열화도 측정 센서연구)

  • Kim, Won-Tae;Choi, Man-Yong;Park, Hae-Won;Park, Jung-Hak
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.24 no.3 s.192
    • /
    • pp.61-66
    • /
    • 2007
  • This work is aimed to measure the deterioration in oil sensor. For the study, the circuit of a coil-type oil sensor packaged was developed and applied to the automobile engine for monitoring the deterioration of engine oil in driving conditions. From the principle which the deterioration of automobile engine oil can be expressed to the dielectric constant, the capacitance bridge circuit and the integrator circuit were designed. As results, the range of operating temperature of engine oil was experimentally recommended within $55^{\circ}C$ for the stability of a sensor designed. It was also concluded that the characteristics of output voltage converted from the dielectric constant were linearly distributed and predicted the optimized time for the exchange of engine oil.

A Study on Approximate Analysis of Superconductor Antenna (초전도체 안테나의 근사해석에 관한 연구)

  • Hwang, Jae-Ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.05a
    • /
    • pp.77-79
    • /
    • 2012
  • The paper deals with the approximate analysis of printed antenna like superconductor antenna. Analysis of antenna with polarization current in dielectric layer using Moment method. This approximation is very useful for printed antenna on dielectric plane with low dielectric constant. In this paper, we compared numerical results of this method with measurement results.

  • PDF

Properties of Multilayer Glass-Ceramic Dielectrics (다층 글라스세라믹 유전체의 결정화특성에 관한 연구)

  • 이헌수;손명모;박희찬
    • Journal of the Korean Ceramic Society
    • /
    • v.31 no.9
    • /
    • pp.981-988
    • /
    • 1994
  • Crystallizable glasses with precipitation of celsian were prepared for the purpose of insulating dielectric layers for the devices such as integrated circuit substrates. Crystallization behavior of these glasses were studied by DTA, SEM, XRD analysis and by the measurement of dielectric properties. The base composition of the glass-ceramic consists in weight percent of 30% SiO2, 10% Al2O3, 26% BaO, 10% CaO, 10% ZnO, 8%TiO2 and 6% B2O3. 2-6 wt% Y2O3 were selected as the nucleating agent to promote monoclinic celsian formation. As a result, in barium-rich glasses containing 4~6wt% Y2O3 , monoclinic celsian was developed as major crystalline phase in the temperature range of 850~90$0^{\circ}C$. Also, the dielectric constant and quality factor of these glass-ceramics were about 9 and more than 1000, respectively.

  • PDF

Dielectric Characteristics of Epoxy Molding Compound irradiated with Electron Beam (전자선 조사된 에폭시 몰딩 컴파운드의 유전 특성)

  • 홍능표;박우현;이성용;김대수;이수원;홍진웅
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1995.11a
    • /
    • pp.289-292
    • /
    • 1995
  • In this experiment the specimen is selected for epoxy resin used in the molding compound materials for the power semiconductors. The specimen was divided into the two parts. one is a specimen without irradiation, the other is irradiated with electron beam, of which dose is 1[Mrad], 2[Mrad], 4[Mrad], 8[Mrad] and 24[Mrad], respectively. From the analysis for the physical properties of the specimen, the carbonyl group which is asffact the electrical properties is decreased according to increase the dose of the electron beam. In the measurement of dielectric characteristics among the electrical properties, the frequency dependance of the dielectric characteristics is confirmed that its ${\beta}$-peak is represented by one peak due to attribute to the main chain below 50[$^{\circ}C$], and two peak above the temperature 100[$^{\circ}C$].

  • PDF

Electrical properties variations of nitrided, reoxided MOS devices by nitridation condition (질화와 재산화 조건에 따른 모스 소자의 전기적 특성변화)

  • 이정석;이용재
    • Proceedings of the IEEK Conference
    • /
    • 1998.06a
    • /
    • pp.343-346
    • /
    • 1998
  • Ultra-thin gate oxide in MOS devices are subjected to high-field stress during device operation, which degrades the oxide and exentually causes dielectric breakdown. In this paper, we investigate the electrical properties of ultra-thin nitrided oxide (NO) and reoxidized nitrided oxide(ONO) films that are considered to be promising candidates for replacing conventional silicon dioxide film in ULSI level integration. We study vriations of I-V characteristics due to F-N tunneling, and time-dependent dielectric breakdown (TDDB) of thin layer NO and ONO depending on nitridation and reoxidation condition, and compare with thermal $SiO_{2}$. From the measurement results, we find that these NO and ONO thin films are strongly depending on its condition and that optimized reoxided nitrided oxides (ONO) films show superior dielectric characteristics, and breakdown-to-change ( $Q_{bd}$ ) performance over the NO films, while maintaining a similar electric field dependence compared to NO layer.

  • PDF

The Design of a Dielectric Rod Antenna Using Genetic Algorithm Optimization for Vessel's Collision Avoidance Applications

  • Kahng, Sung-Tek;Ju, Jeong-Ho
    • Journal of electromagnetic engineering and science
    • /
    • v.7 no.3
    • /
    • pp.129-133
    • /
    • 2007
  • In this paper, we present the development of an antenna specialized for the maritime collision avoidance system. This antenna is configured as the dielectric rod partially embedded in the metal cavity to reduce the overall size, simultaneously assuring the mechanical sturdiness against the challenging oceanic weather conditions. More importantly, the design has been carefully done to meet the requirements on the radiation pattern(with the slope < 5 dB/deg in the elevation(E-plane), circular in the azimuth) suitable to receiving the reflected signals from the other objects on the sea. To find the optimal design parameters, the genetic algorithm has been used to meet the goals of the desired return loss and pattern. This design methodology is validated by the good agreement between the calculation and measurement.