• 제목/요약/키워드: Dielectric breakdown voltage

검색결과 354건 처리시간 0.03초

평등전계중의 절연유에 미치는 첨가물의 영향 (A study on the effect of additives in insulating oil under uniform electric field)

  • 국상훈
    • 전기의세계
    • /
    • 제30권6호
    • /
    • pp.357-365
    • /
    • 1981
  • When electronegative gas SF$_{6}$ is dissolved and charged with insulating oil, the effect caused in the process by electronegative characteristic is studied and also the pressure effect caused by electronegative SF$_{6}$ acting on the liquid-level is examined respectively. When inert gas Ar is used to find a pressure effect acting on the liquid-level, its effect on dielectric strength is considered in the experiment. With three kinds of impulse voltage different in the duration of wave front and wave tail, a brief experiment if carried out ot see the effects on the dielectric breakdown characteristic as the wave is changing; either if I$_{2}$ and SF$_{6}$ are added to the insulating oil, or if the oil pressure is increased by Ar the dielectric strength becomes great and the longer the duration of wave front is, the greater the increase of the breakdown voltage, because I$_{2}$ added by a small quantity brings about some hirderance in the formation of gas phase. Likewise, the greater the changed pressure is, the greater the incerase of the breakdown voltage. When SF$_{6}$ is charged, the electronegative characteristic is prevailing at the time of low balanced pressure, and the pressure effect at the time of high balanced pressure.ressure.

  • PDF

옥외용 LED 조명의 전기화재 위험성 평가기법에 관한 연구 (A Study on the Electrical Fire Risk Assessment Methods of LED Lightings for Outdoor)

  • 김향곤;김동욱;최효상
    • 전기학회논문지
    • /
    • 제60권3호
    • /
    • pp.674-679
    • /
    • 2011
  • In this paper, we experimented and analyzed about electric fire risk assessment methods of LED lightings for outdoor. LED lighting is composed of AC power lines, AC/DC converter, DC power lines and LED lamps. There are some risk factors of electric fire in LED lighting such as short circuit between power lines or power line and ground, dielectric breakdown, leakage current, abnormal voltage inflow, poor contacts(connections), etc. As a result of this study, insulation coverings of wire was ignited due to dielectric breakdown between power lines and molten marks were formed in copper conductor. LED lighting was blown out while short circuit, beside that, electrical disorder did not occur. When abnormal voltage was inflowed, electronic components such as varistor, condenser were damaged. Partial heating was produced and insulation was melted and carbonized by arc and heating while poor contacts were happened. We expect that the results of this study would be helpful for electrical safety of LED lightings for outdoor.

나노 충진제에 따른 에폭시 나노 컴퍼지트의 절연파괴강도 특성 (Dielectric Breakdown Characteristics Depending on The Nano Filler of Epoxy Nano-composites)

  • 박태학;백승학;이동건;박홍규;정인범;홍진웅
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.92-92
    • /
    • 2010
  • In this paper, the test is performed on MgO, which is used as a filler in epoxy additives, respectively (0, 1.0, 3.0, 5.0, 7.0, 10 [wt%]) for HVDC(high voltage direct current) submarine cable insulating material to improve electrical properties of epoxy resin in high temperature. The breakdown strength due to increasing amount of filler increased to 5.0 [wt%] by the effects of the Coulomb blockade. However, it is confirmed that strength of dielectric breakdown decreased because the filler functioned as impurities and affected the breakdown when filler additive exceeded by 5.0 [wt%] or more. We have found that the highest dielectric breakdown strength of specimen added 5.0 wt% at $25^{\circ}C$, and is more increased approximately 13.7 [%] than virgin specimen.

  • PDF

평면형 대기압 유전장벽방전장치의 제작 및 동작특성분석 (Fabrication of Atmospheric Coplanar Dielectric Barrier Discharge and Analysis of its Driving Characteristics)

  • 이기융;김동현;이호준
    • 전기학회논문지
    • /
    • 제63권1호
    • /
    • pp.80-84
    • /
    • 2014
  • The discharge characteristics of Surface Dielectric Barrier Discharge (SDBD) reactor are investigated to find optimal driving condition with adjusting various parameter. When the high voltage with sine wave form is applied to SDBD source, successive pulsed current waveforms are observed owing to multiple ignitions through the long discharge channel and wall charge accumulation on the dielectric surface. The discharge voltage, total charge between dielectrics, mean energy and power are calculated from measured current and voltage according to electrode gap and dielectric thickness. Discharge mode transition from filamentary to diffusive glow is observed for narrow gap and high applied voltage case. However, when the diffusive discharge is occurred with high applied voltage, the actual firing voltage is always lower than that with low driving voltage. The $Si_3N_4$, $MgF_2$, $Al_2O_3$ and $TiO_2$ are considered for dielectric protection and high secondary electron emission coefficient. SDBD with $MgF_2$ shows the lowest breakdown voltage. $MgF_2$ thin film is proposed as a protection layer for low voltage atmospheric dielectric barrier discharge devices.

Analysis of Dielectric Breakdown of Hot SF6 Gas in a Gas Circuit Breaker

  • Kim, Hong-Kyu;Chong, Jin-Kyo;Song, Ki-Dong
    • Journal of Electrical Engineering and Technology
    • /
    • 제5권2호
    • /
    • pp.264-269
    • /
    • 2010
  • This paper presents the analysis of the dielectric characteristics of a hot $SF_6$ gas in a gas circuit breaker. Hot gas flow is analyzed using the FVFLIC method considering the moving boundary, material properties of real $SF_6$ gas, and arc plasma. In the arc model, the re-absorption of the emitted radiation is approximated with the boundary source layer where the re-absorbed radiation energy is input as an energy source term in the energy conservation equation. The breakdown criterion of a hot gas is predicted using the critical electric field as a function of temperature and pressure. To validate the simulation method, breakdown voltage for a 145kV 40kA circuit breaker was measured for various conditions. Consistent results between the simulation and experiment were confirmed.

Laser CVD에 의한 SiON막의 형성과 그 특성 (The Formation and Characteristics of Laser CVD SiON Films)

  • 권봉재;박종욱;천영일;이철진;박지순;성영권
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1991년도 추계학술대회 논문집 학회본부
    • /
    • pp.241-244
    • /
    • 1991
  • In this paper, we introduced Silicon Oxynitride films deposited by Laser CVD, and evaluated the electrical breakdown of these films by TZDB(Time Zero Dielectric Breakdown) and TDDB(Time Dependent Dielectric Breakdown) test. In addition, high frequency C-V test was done in order to calculate hysterisis and flatband voltage(before and after electric field stress). Failure times against eletric field are examined and electric field accelation factor $\beta$ are obtained, and long term reliability was also described by extrapolating into life time in the operating voltage(5V). In this experiments, the deposited films with increased temperature represented small flatband voltage, hysterisis and favorable breakdown characteristics, this is why the hydrogen in the film was decreased and the film was densified, long term reliability was good in the laser CVD SiON films.

  • PDF

준평등전계에서 임펄스전압에 대한 N2가스의 절연파괴특성 (Dielectric Characteristics of N2 Gas under Impulse Voltage in a Quasi-Uniform Electric Field)

  • 이복희;김동규;이봉
    • 조명전기설비학회논문지
    • /
    • 제24권8호
    • /
    • pp.126-132
    • /
    • 2010
  • 본 논문은 준평등전계중에서 임펄스전압에 대한 $N_2$가스의 절연파괴특성에 관한 것으로 실험은 1.2/50[${\mu}s$] 표준뇌임펄스전압, 180/2500[${\mu}s$] 개폐임펄스전압과 500[ns]/1[MHz] 급준성 과도과전압이 인가된 전극계에서 이루어졌다. 구-평판 전극의 간격은 14[mm]이고, 전계이용률은 71.2[%]이었으며 가스압력은 0.2~0.6[MPa]범위로 하였다. 그 결과 절연파괴는 스트리머방전에 의하여 일어났으며, 절연파괴전압은 상승시간이 빠른 급준성 과도과전압에서 가장 높게 나타났다. 정극성 절연파괴전압이 부극성보다 높았으며, 정극성의 경우 절연파괴까지의 시간도 더 긴 것으로 나타났다.

$SF_6-N_2$ 혼합가스에서 과도임펄스전압에 대한 V-t특성 (V-t Characteristics in $SF_6-N_2$ Mixtures for Transient Impulse Voltages)

  • 이복희;이경옥
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제50권9호
    • /
    • pp.456-465
    • /
    • 2001
  • In this paper, breakdown voltages in $SF_6-N_2$ mixtures were experimentally investigated to understand characteristics of dielectric strength and physical phenomena in nonuniform field disturbed by a needle shape protrusion. The test voltages are the lightning impulse$(\pm1.2/44 \mus)$ and the damped oscillatory impulse$(\pm400 ns / 0.83 MHz)$ voltages which can be occurred by the operation of disconnecting switches in gas-insulated switchgears(GIS). The effects of the polarity and wave shape of the test voltages, and the gas pressure on the V-t characteristics were in detail examined. The V-t characteristic curves were measured in different two ways : (1) one is the method by taking the maximum voltage recorded at or prior to breakdown against the time to breakdown, that is, the Procedures recommended in IEC 60060-1, (2) the other is the method by taking the voltage at the instant of chopping against the time to breakdown. As a result, the V-t characteristics of $SF_6-N_2$ mixtures in nonuniform electric field were significantly affected by the polarity and wave shape of the applied voltages. The positive breakdown voltages resulted in lower breakdown voltages in the time ranges considered, and the V-t curves for the negative oscillatory impulse voltage were extended over the longer time range. For the lightning impulse voltages, the V-t curves obtained by IEC Pub. 60060-1 were nearly same with the V-t curves obtained by the voltage at the instant of chopping against the time to breakdown. It is clear that the actual breakdown voltages were much lower than the maximum voltages appearing at or prior to breakdown because of the displacement current produced as a result of the dV/dt during the oscillatory transient voltage app1ication. The scattering of the negative actual breakdown voltages was much larger than that of the positive.

  • PDF

Analysis of Gate-Oxide Breakdown in CMOS Combinational Logics

  • Kim, Kyung Ki
    • 센서학회지
    • /
    • 제28권1호
    • /
    • pp.17-22
    • /
    • 2019
  • As CMOS technology scales down, reliability is becoming an important concern for VLSI designers. This paper analyzes gate-oxide breakdowns (i.e., the time-dependent dielectric-breakdown (TDDB) aging effect) as a reliability issue for combinational circuits with 45-nm technology. This paper shows simulation results for the noise margin, delay, and power using a single inverter-chain circuit, as well as the International Symposium on Circuits and Systems (ISCAS)'85 benchmark circuits. The delay and power variations in the presence of TDDB are also discussed in the paper. Finally, we propose a novel method to compensate for the logic failure due to dielectric breakdowns: We used a higher supply voltage and a negative ground voltage for the circuit. The proposed method was verified using the ISCAS'85 benchmark circuits.

진단용 X 선관 절연유의 전기적 특성 (Electrical Properties of Insulating Oils for Diagnostic X-ray Tube)

  • 김건중;이인성;백금문;김두호;김왕곤;홍진웅
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집 Vol.14 No.1
    • /
    • pp.597-600
    • /
    • 2001
  • In order to investigate the electrical properties of X-ray tube oils for insulating and cooling, the breakdown characteristics in temperature range of $20\sim100[^{\circ}C]$, that of AC breakdown in 0.5~2.5[mm] of gap length, we are made researches. The classification for the physical properties of oil for X-ray tube by FTIR and H-NMR experiments was confirmed to type of mineral oils. As for the dependance of breakdown characteristics due to electrode gap length, breakdown voltage was found nearly uniform by impurity effect according to the increase of gap. As a result the characteristics for AC breakdown, the dielectric strength was increased to $90[^{\circ}C]$ but decreased over $90[^{\circ}C]$ in the temperature range.

  • PDF