• Title/Summary/Keyword: Diagnostic yield

Search Result 146, Processing Time 0.028 seconds

Abnormal Detection in 3D-NAND Dielectrics Deposition Equipment Using Photo Diagnostic Sensor

  • Kang, Dae Won;Baek, Jae Keun;Hong, Sang Jeen
    • Journal of the Semiconductor & Display Technology
    • /
    • v.21 no.2
    • /
    • pp.74-84
    • /
    • 2022
  • As the semiconductor industry develops, the difficulty of newly required process technology becomes difficult, and the importance of production yield and product reliability increases. As an effort to minimize yield loss in the manufacturing process, interests in the process defect process for facility diagnosis and defect identification are continuously increasing. This research observed the plasma condition changes in the multi oxide/nitride layer deposition (MOLD) process, which is one of the 3D-NAND manufacturing processes through optical emission spectroscopy (OES) and monitored the result of whether the change in plasma characteristics generated in repeated deposition of oxide film and nitride film could directly affect the film. Based on these results, it was confirmed that if a change over a certain period occurs, a change in the plasma characteristics was detected. The change may affect the quality of oxide film, such as the film thickness as well as the interfacial surface roughness when the oxide and nitride thin film deposited by plasma enhenced chemical vapor deposition (PECVD) method.

Diagnostic Accuracy of Urease and Polymerase Chain Reaction to Detect Helicobacter Species Infection in Dogs (개에서 Helicobacter균 감염을 검출하기 위한 urease 검사와 PCR 검사의 진단적 정확도)

  • Pak, Son-Il;Oh, Tae-Ho
    • Journal of Veterinary Clinics
    • /
    • v.18 no.4
    • /
    • pp.329-333
    • /
    • 2001
  • Evaluation on the diagnostic performances of urease test and polymerase chain reaction (PCR) for detection of Helicobacter species infection in dogs has rarely been performed in research with site-specific situations, although assessing diagnostic tests is an essential part prior to its practical use in a variety of clinical settings. The clinical value of a diagnostic test may be misjudged and comparisons between different tests may yield misleading conclusions when high within-patient correlations are present. We applied a conceptually simple statistical approach to estimate the sensitivity and specificity of urease test and PCR for detection of Helicobacter species infection in dogs. This approach assumes that responses from three different sampling sites within an animal are correlated where unit for statistical analysis is the site rather than the animal. The sensitivity and specificity of urease test was 0.74% (95% confidence interval, 0.64-0.84) and 0.87 (95% CI, 0.67-1.00), respectively. For PCR, the sensitivity was 0.95(95% CI, 0.89-1.00) and specificity 0.90 (95% CI, 0.70-1.00). Two tests were almost equally specific. Urease test, however, has a lower diagnostic accuracy and thus should only be used after careful validation in terms of sensitivity.

  • PDF

The Utility of Scalene Lymph Node Biopsy in the Diagnosis of Sarcoidosis (유육종증 진단에서의 사각근 림프절 생검의 유용성)

  • Chung, Won-Sang;Kim, Young-Hak;Song, Young-Joo;Kim, Ji-Hoon;Kim, Hyuck
    • Journal of Chest Surgery
    • /
    • v.43 no.6
    • /
    • pp.694-699
    • /
    • 2010
  • Background: In addition to clinical and radiographic findings, a histopathologic examination is important in the diagnosis of sarcoidosis. This study evaluated the diagnostic usefulness of a scalene node biopsy in patients with suspected sarcoidosis. Material and Method: We studied 35 patients who underwent scalene node biopsy because of suspicion of sarcoidosis on a chest x-ray and a computerized tomogram between 2001 and 2009, regardless of symptoms. Result We studied 15 men and 20 women whose mean age was $41.51{\pm}11.21$ years (25~64). Three among the 35 were diagnosed with tuberculosis and 27 with sarcoidosis, resulting in a diagnostic yield of 84.4%. The mean lymph node diameter size was 1.3 (${\pm}0.12$) (0.3~3.6 cm) cm. We divided the group of participants according to stage - whether on chest x-ray the lung was affected or not (stage 0, 1 and stage 2, 3). We divided lymph node sizes as well - whether they were larger than 1 cm or smaller than 1 cm. For these subgroups, there were no significant differences in diagnostic yield (p=0.604) (p=0.084). There were no complications or mortality. Conclusion: Scalene node biopsies are simply done under local anesthesia, without major complications. They have a high diagnostic yield regardless of the stages of the disease and lymph node size. We conclude that scalene node biopsy is a good alternative to other biopsy methods in sarcoidosis.

Clinical Studies about diagnostic Yields according to Variable Diagnostic Methods in Lung Cancer (폐암에서 각종 진단수기에 따른 진단율에 관한 연구)

  • Kang, Dae-Song;Cho, Jin-Ung;Kim, Sang-Gyun;Kim, Mi-Ae;Yang, Sung-Uk;Lee, Tae-Quan;Lee, Tae-Hun;Kim, Kwi-Wan
    • Tuberculosis and Respiratory Diseases
    • /
    • v.40 no.6
    • /
    • pp.700-708
    • /
    • 1993
  • Background: Lung cancer has become one of the most common cancers in Korea. It is important to determine the accurate histologic types and stages because of different therapeutic modlaity, especially in small cell carcinoma. This study was designed to evaluate diagnostic yields according to variable diagnostic methods in lung cancer. Methods: The records of 683 patients with a confirmed diagnosis of primary lung cancer during the period of 7 years, from January, 1986 until December, 1992 at Presbyterian Medical Center were analyzed retrospectively. Results: 1) Age and sex distributions Male: female sex ratio was 5.57:1 and age distributions were 7th decade 41.4%, 6th decade 30.2%, 8th decade 17.0%, 5th decade 7.9%, 4th decade 2.5%, 9th decade 1.3%, and 3rd decade 0.2% in decreasing order. 2) The frequencies according to histologic cell types were squamous cell carcinoma 44.7%, small cell carcinoma 23.9%, adenocarcinoma 22.8%, alveolar cell carcinoma 2.5%, large cell carcinoma 1.2%. mixed forms 1.2%, undifferenciated cell carcinoma 0.6% and malignant fibrous histiocytoma 0.2%(1 case) in decreasing order. 3) The most common locations of lung cancer were in left upper lobe and right lower lobe, and no differences of diagnostic methods according to locations were noted. 4) In central lesions, bronchoscopic examination was very accurate and frequently used diagnostic method, and in peripheral lesions, transthoracic lung biopsy(TTLB) was apparent1y accurate method. 5) The diagnostic yields of bronchoscopic biopsy, bronchial brushing, sputum cytology, transthoracic lung biopsy and transbronchial lung biopsy(TBLB) were 81.3%, 57.5%, 31.1%, 69.6% and 61.6%, respectively. 6) The concordance rates between the histologic diagnosis with bronchial brushing and sputum-cytology were 91.3% and 98.4%, respectively. 7) It was appropriate in lung cancer to repeat sputum cytology 3 to 5 times. Conclusion: Bronchoscopic examination is important to determine the histologic cell types in lung cancer. In addition, we should be interrested in improving diagnostic yields of sputum cytology as an easy method.

  • PDF

Bronchoscopy and Surgical Lung Biopsy for the Diagnosis and Management of Pulmonary Infiltrates in Immunocompromised Hosts (면역저하환자에서 발생한 폐침윤에서 기관지내시경과 수술적 폐생검의 유용성)

  • Park, Sang-Joon;Kang, Soo-Jung;Koh, Young-Min;Suh, Gee-Young;Kim, Ho-Joong;Kwon, O-Jung;Lee, Hong-Ghi;Rhee, Chong-H.;Chung, Man-Pyo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.47 no.2
    • /
    • pp.195-208
    • /
    • 1999
  • Background: Pulmonary infiltrate in immunocompromised hosts has many infectious and non-infectios etiologies. To evaluate the diagnostic yield and therapeutic implication of two invasive diagnostic methods, such as bronchoscopy and surgical lung biopsy, we performed retrospective analysis of these patients. Methods: All immunocompromised patients admitted to Samsung Medical Center from October 1995 to August 1998 who underwent bronchoscopy and/or surgical lung biopsy for the diagnosis of pulmonary infiltrates were included in this study. Confirmative diagnostic yield, the rate of changed therapeutic plan and patients' survival were investigated. Results: Seventy-five episodes of pulmonary infiltrates developed in 70 patients(M : F=46 : 24, median age 51). Underlying diseases of patients were hematologic malignancy(n=30), organ transplantation(n=11), solid tumor(n= 12), connective tissue disease(n=6) and others. Confirmative diagnosis was made in total 53 cases (70.7%), of which 70.2% had infectious etiology. Diagnostic yields of bronchoscopy, bronchoalveolar lavage(BAL), transbronchiallung biopsy(TBLB) and surgical lung biopsy were 35.0%(21/60), 31.4%(16/51), 25.0%(9/36) and 80.0%(20/25). Therapeutic plan was changed in 40%(24/60) of patients after bronchoscopy and in 36%(9/25) of patients after surgical lung biopsy. More patients survived (84.4% vs 60.5%, p=0.024) when therapeutic plan was changed after invasive diagnostic study. Conclusion: Bronchoscopy and surgical lung biopsy are helpful for the therapeutic implication of pulmonary infiltrates in immunocompromised hosts. Large-scale prospective case-control study may further clarify their limitation and usefulness.

  • PDF

Diagnostic Assay of Toxic Zinc in an Ex Vivo Cell Using Voltammetry

  • Ly, Suw-Young;Yoo, Hai-Soo
    • Toxicological Research
    • /
    • v.28 no.2
    • /
    • pp.123-127
    • /
    • 2012
  • Voltammetric detection of the toxic Zn ion was investigated using a fluorine-doped graphite pencil electrode (FPE). It is notable from the study that pencils were used as reference and working electrodes. In all the experiments, a clean seawater electrolyte solution was used to yield good results. The analytical working range was attained to 10 ${\mu}gL^{-1}$. The optimized voltammetric condition was examined to maximize the effect of the detection of trace Zn. The developed sensor was applied to an earthworm's tissue cell. It was found that the methods can be applicable to in vivo fluid or agriculture soil and plant science.

Prediction of the Prosthetic Valve size by use of Supraaortic Cineangiogram (Cineangiogram 을 이용한 대동맥판막의 수술전 인공판막 치수의 예)

  • Lee, Young-Thak;Ahn, Hyuk;Park, Jae-Hyung
    • Journal of Chest Surgery
    • /
    • v.20 no.1
    • /
    • pp.60-64
    • /
    • 1987
  • We compared between prosthetic aortic valve size and aortic annulus size in supravalvular aortic cineangiogram in 30` RAO view postoperatively. Retrospectively, supraaortic cineangiogram of 27 patients among the patients underwent aortic valve replacement only or double valve replacement from April, 1986 to January, 1987 was examined and measured the aortic annulus size. In comparing the two values, the cases within 1mm is 22, and the cases within 2mm is 25, correlation coefficient yield r = 0.92. In two cases, the difference between two values is within 3mm We concluded that to prevent the complication from mismatching the prosthetic aortic valve size to patient`s annulus size [e.g. left ventricular failure, hemolysis, limited exercise tolerance], prediction of the prosthetic valve size preoperatively by use of cineangiogram is useful.

  • PDF

Sonographic evaluation of the diaphragm in patients with unilateral diaphragmatic paralysis

  • Seok, Jung Im;Kim, Kyung Chan;Rha, Hye Joo;Lee, Sung Rok
    • Annals of Clinical Neurophysiology
    • /
    • v.20 no.2
    • /
    • pp.93-96
    • /
    • 2018
  • Evaluation of diaphragm function is challenging because no single test has a high diagnostic yield. We describe ultrasound findings in three cases with acquired unilateral diaphragmatic elevation. These cases confirm that sonographic evaluation is a valid tool for identifying diaphragm dysfunction. In addition, ultrasound measurements of diaphragm thickness and the contractility can be used to determine if a diaphragm is paralyzed and suggest the duration of paralysis (i.e., acute or chronic).

High-Resolution Magnetic Resonance Imaging of Intracranial Vertebral Artery Dissecting Aneurysm for Planning of Endovascular Treatment

  • Chun, Dong Hyun;Kim, Sung Tae;Jeong, Young Gyun;Jeong, Hae Woong
    • Journal of Korean Neurosurgical Society
    • /
    • v.58 no.2
    • /
    • pp.155-158
    • /
    • 2015
  • The equipment and techniques associated with magnetic resonance imaging (MRI) have rapidly evolved. The development of 3.0 Tesla MRI has enabled high-resolution imaging of the intracranial vessel wall. High-resolution MRI (HRMRI) can yield excellent visualization of both the arterial wall and lumen, thus facilitating the detection of the primary and secondary features of intracranial arterial dissection. In the present report, we describe the manner in which HRMRI affected our endovascular treatment planning strategy in 2 cases with unruptured intracranial vertebral artery dissection aneurysm. HRMRI provides further information about the vessel wall and the lumen of the unruptured intracranial vertebral artery dissecting aneurysm, which was treated by an endovascular approach in the 2 current cases.