• Title/Summary/Keyword: Diagnostic sensor

Search Result 238, Processing Time 0.025 seconds

Diagnostic Ex-vivo Assay of Metal Gold in Rat Droppings Using Voltammetry

  • Ly, Suw-Young;Lee, Chang-Hyun
    • Journal of the Korean Applied Science and Technology
    • /
    • v.29 no.4
    • /
    • pp.626-630
    • /
    • 2012
  • Diagnosis with an ex-vivo gold sensor was done using a modified fluorine-doping sensor, and cyclic voltammetry (CV) redox potentials of 0.4 V anodic and -0.2 V cathodic were obtained. Both peak currents were optimized using square-wave (SW) stripping voltammetry, and an analytical working range of 10-80 ug/L SW was attained. The precision of the 10-mg/L Au was 0.765 (n=8) RSD under the optimum conditions, and the analytical detection limit approached 0.006 ug/L (S/N=3) with only a 60 sec accumulation time. The developed method was used to examine the mouse droppings for medicinal diagnosis.

Development of Portable System for Measuring pH in Blood (휴대용 혈중pH 측정시스템의 구현)

  • 정도운;김우열;배진우;강성철;심윤보;전계록
    • Proceedings of the IEEK Conference
    • /
    • 2001.06e
    • /
    • pp.195-198
    • /
    • 2001
  • We developed the portable blood analysis system, which can be measured pH of the blood. This system is composed to electronic circuit, mechanism, and system software. Electronic circuit is composed to the sensor, pre-amp part, temperature regulation part, fluid sensing part, A/D(analog to digital) conversion part, main and peripheral device processing part. And the mechanism is composed to the flow cell and the liquid flow part. The liquid flow part is consisted of blood and washing control system under the control of the 6-channel solenoid valve and syringe rump. The system software is composed to measurement program, calibration program, washing and diagnostic program. The program of each routine is designed as sequential process for an efficiency. And the portable pH analysis system used two-point calibration method using the two types of corrective liquid. As a result, we obtained the calibration curve and calculated the value of pH. For verifying the system, we confirmed the output voltage of the sensor, and estimated reappearance of system using the standard liquid.

  • PDF

Design and fabrication of 3-dimensional diagnostic Ultrasonic transducers (3차원 입체영상 진단용 초음파 트랜스듀서의 설계 및 제작)

  • Eun Hong;Kwon JaeHwa;Lee Susung;Roh Yongrae
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • spring
    • /
    • pp.345-348
    • /
    • 2002
  • 본 연구에서는 128개의 능동소자로 구성된 convex형 초음파 탐촉자를 회전시켜 3차원 입체영상을 구현 할 수 있도록 하는 구동부를 설계 및 제작하여, 3차원 입체 영상 진단용 초음파 섹터 트랜스듀서를 개발하였다. 탐촉자는 중심주파수 4.5Mhz, 대역폭 $66\%$로 제작되었으며, 구동부는 탐촉자의 축을 스텝모터와 평기어를 이용해 회전시킴으로써 3차원 입체영상을 획득할 수 있게 고안하였다. 그리고 피부와 유사한 고분자재료를 사용하여 탐촉자의 회전반경과 동일하게 음향커버를 설계 및 제작하였다. 제작된 초음파 섹터 트랜스듀서는 정밀한 각도 제어 및 구조적 안정성이 확보되었음을 확인 할 수 있었다.

  • PDF

Development of A/T Oil Temperature Sensor Plausibility Diagnostic Logic (자동변속기 오일 온도센서 출력 이상 진단 로직 개발)

  • Kwon, Jun-Eui;Choi, Young-Sun;Sim, Jang-Sun
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.13 no.6
    • /
    • pp.99-104
    • /
    • 2005
  • The CARB in USA has demanded OBD functions that detect any deterioration of performance of OTS as well as a simple defect of OTS which can affect emission to meet the reinforced emission regulation. In this paper, OTS plausibility monitoring functions to meet the demand from CARB are discussed. The output from OTS is used for the diagnostics of the torque converter clutch stuck and the gear ratio synchronous error. It is possible to diagnose the abnormality of OTS function by considering the oil temperature characteristics which changes according to the driving status of vehicles. In result, the OBD regulations of the CARB can be satisfied obligating car manufacturer to detect any problems in OTS functions which can affect emissions.

Biosensors (바이오센서)

  • 김의락
    • KSBB Journal
    • /
    • v.15 no.5
    • /
    • pp.423-427
    • /
    • 2000
  • Intense research on biosensors has been performed in a number of different institution over the past 15 years, but relatively few commercial products have resultingly, the blood glucose sensor is a good example of a product which penetrated the market. However recently, the development of electrochemical and optical technologies has accelerated the turnover of the research as is illustrated by a rapid increase in the number of point-of-care diagnostic systems and analytical devices. Examples of such biosensors used in the fields of medical diagnostics, bioprocess control, and environmental monitoring are described, and summarized in an introduction to their characteristics, structures, and functions, given.

  • PDF

An ECG Monitoring and Analysis Method for Ubiquitous Healthcare System in WSN

  • Bhardwaj, Sachin;Lee, Dae-Seok;Chung, Wan-Young
    • Journal of information and communication convergence engineering
    • /
    • v.5 no.1
    • /
    • pp.7-11
    • /
    • 2007
  • The aim of this paper is to design and implement a new ECG signal monitoring and analysis method for the home care of elderly persons or patients, using wireless sensor network (WSN) technology. The wireless technology for home-care purpose gives new possibilities for monitoring of vital parameter with wearable biomedical sensors and will give the patient freedom to be mobile and still be under continuously monitoring. Developed platform for portable real-time analysis of ECG signals can be used as an advanced diagnosis and alarming system. The ECG features are used to detect life-threatening arrhythmias, with an emphasis on the software for analyzing the P-wave, QRS complex, and T-wave in ECG signals at server after receiving data from base station. Based on abnormal ECG activity, the server transfer diagnostic results and alarm conditions to a doctor's PDA. Doctor can diagnose the patients who have survived from arrhythmia diseases.

Developement of Gas Detector Dissolved In Transfomer Oil (변압기 절연유중 수소 가스의 검지 시스템 설계)

  • Hwang, Kyu-Hyun;Seo, Ho-Joon;Rhie, Dong-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07a
    • /
    • pp.207-210
    • /
    • 2004
  • In oil-filled equipment such as transformers, partial discharge or local overheating will make insulating material(oil, kraft paper, proclain and wood) be stressed and generate many sort of gases($CO,\;CO_2,\;H_2,\;C_2H_4$) which are dissolved in transformer oil. The ratio of this gas can make diagnostic tecchniques of the lifetime of transfomer so, it is important to monitoring $H_2$ gas continuously. This paper developes a system of detecting about $H_2$ gas by using $H_2$ gas sensor, and we describe operation and performance of this system

  • PDF

Diagnostic ex vivo assay of glucose in live cell using voltammetry

  • Ly, Suw Young;Leea, Chang Hyun
    • Journal of the Korean Applied Science and Technology
    • /
    • v.35 no.4
    • /
    • pp.1379-1385
    • /
    • 2018
  • The hand held voltammetry systems searched diabetic assay using glucose sensor of fluorine nafion doped carbon nanotube electrode (FCNE). An inexpensive graphite carbon pencil was used as an Ag/AgCl reference and Pt counter electrode. Upon combining and using three electrode systems, optimum square wave (SW) stripping results were attained to 1.0-9.0 ug/L with 8 points. Statistic RSD precision was of 6.02 % with n=15 in 0.1 mg/L glucose. After a total of 200 second accumulation times, analytical detection limit of 0.8 ug/L was obtained. This developed technique was applied to urine samples from diabetic patients urine for fluid analysis, it was determined that the sensor can be used with a diagnostics in the ex vivo of live cells and non treated biological fluid.

New function propose 'sensor status diagnostic' for ensure sensor value in ISA100.11a Network (ISA100.11a 네트워크에서 각 디바이스의 센서값에 대한 유효함을 보장하기 위한 센서 상태 진단 기능 제안)

  • Kim, Do-Sung;Chung, Yong-Hun;Yoo, Seung-Wha;Kim, Ki-Hyung
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2011.04a
    • /
    • pp.740-743
    • /
    • 2011
  • 산업장내에 사용하는 무선 네트워크인 ISA100.11a 네트워크의 각 디바이스들의 센서값의 유효함을 보장하기 위하여 센서 상태 진단 기능을 제안한다. ISA100.11a 네트워크의 각 디바이스들은 자체적으로 디바이스들의 오류를 감지하는데 디바이스 오류 감지 기준이 단순하여 다양한 오류에 대해서는 진단 기능이 취약하다. 또한 적은 디바이스의 리소스으로는 정교한 오류 감지에 한계가 있다. 그래서 본 논문는 정교한 오류 감지법과 디바이스 리소스를 고려하여 센서 상태를 진단하는 기능을 제안한다.

Key Technical Challenges for Integrated Sensors in Power Electronics and Motor Drives

  • Lorenz, Robert D.
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.4B no.4
    • /
    • pp.170-179
    • /
    • 2004
  • The paper presents technical issues which integrated sensors must address to be implemented in the next generation of power electronics and motor drives. The underlying goal of the sensor integration will be to improve reliability of power conversion systems while making the power converter and motor drive become the primary source of diagnostic signals for the application. The paper focuses on design methodologies that will allow this integration to succeed in meeting the technical demands for both reliability and for application level diagnostics.