• Title/Summary/Keyword: Diagnostic index

Search Result 622, Processing Time 0.029 seconds

Assessment of Rotor Winding Insulation Condition for Gas Turbine Generators (가스터빈 발전기 회전자 권선의 절연상태 평가)

  • Kim, Hee-Dong;Kim, Byeong-Rae
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.10
    • /
    • pp.1818-1821
    • /
    • 2008
  • Several off-line diagnostic tests which include the insulation resistance(IR), polarization index(PI), low-voltage AC, and recurrent surge oscillograph(RSO) tests were performed to assess the condition of generator rotor windings. The low-voltage AC and the RSO tests were performed on the gas turbine generator rotor winding to detect shorted turns. Before intentionally applying artificial shorted faults, it was confirmed by the low voltage AC and the RSO tests that the winding was in sound condition. For simulated shorted rotor winding turns, the RSO test detected the fault in the winding. The RSO test was capable of identifying the number and pole location of the shorted turns for a number of simulated shorted coils.

Characteristics of Dissipation Factor in High Voltage Motor Stator Windings (고압전동기 고정자 권선의 유전정접 특성)

  • Kim, Hee-Dong
    • Proceedings of the KIEE Conference
    • /
    • 2008.10a
    • /
    • pp.93-94
    • /
    • 2008
  • Diagnostic tests were performed in three high voltage motors. These tests included insulation resistance, polarization index, ac current, dissipation factor($tan{\delta}$) and partial discharge magnitude. The rewind of motor stator insulation at rated voltage is assessed by the results of these tests. After completing the diagnostic tests, the stator windings of motors were subjected to gradually increasing ac voltage, until the insulation punctured. NO.1 and No.2 motors failed near rated voltage of 14.0 kV, respectively. These motors are lower that expected for good quality coils in 6.6 kV class motors. The breakdown voltage of No.3 motor was 15.0 kV.

  • PDF

Assessment of Insulation Condition for Hydro-generator (대용량 수치발전기의 절연진단에 의한 절연상태평가)

  • Lee, Kwang-Ho;Park, Jong-Jin;Kim, Ki-Won;Lee, Eun-Woong
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1810-1812
    • /
    • 2002
  • This test was performed to assess the insulation deterioration condition of the stator winding of Chung-Ju hydrogenerator #4 and Dae-Cheong hydrogenerator #2 which had been in service after being constructed 1980. The insulation diagnostic tests include resistance polarization index(P.I.) AC current, dissipation factor(Tan ${\delta}$) and partial discharges ($Q_{max}$). The results of diagnostic tests were compared to factory test measurements.

  • PDF

A Study on Development of City Gas Safety Diagnosis System Index (도시가스 안전 진단 지표 개발에 관한 연구)

  • 정원익;양광모;전형정;강경식
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2004.05a
    • /
    • pp.1-4
    • /
    • 2004
  • Need safety diagnostic indicator pointer that is objective as estimation basis to be scientific and manages systematically safety existing condition and level for city gas facilities. Safety diagnostic indicator pointer can divide by greatly two. One is management (Software) side that one that differ with mechanical (Hardware) side that handle laying stress on equipment connected with safety manages organization and management connected with safety. Weight appropriates according to specific gravity that relevant element occupies in facilities. To give so big value in particular element in grant of weight pays attention because break balance of whole guideline and should gives. Finally, efficient safety net may see effect before self-regulation inside by minimum target establishment by government and legal, systematic countermeasure establishment for this, strict law application and each business proprietor and though activity and user's active safety activity forms harmony properly.

  • PDF

Assessment of Insulation Condition between Diagnosis and Impregnation for Hydro-Generator (수력발전기의 절연보강 전${\cdot}$후 절연상태 비교평가)

  • Byun il-hwan;Lee Eun-Woong
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.1124-1126
    • /
    • 2004
  • The measurements were performed to assess the insulation deterioration condition of the stator winding of Dae-Cheong hydro-generator ${\sharp}2$ which had been in service after being constructed 1980. After repair of the stator winding insulation. we conducted insulation diagnostic tests which include resistance, polarization index(P. I). AC current, dissipation factor($Tan{\delta}$) and partial discharges ($Q_{max}$). The results of diagnostic tests were compared to the previous records. On the basis of these test results. this paper tried to present the importance of insulation repair for the generator stator winding.

  • PDF

A study on insulation characteristics with AC Breakdown Test for Stator Winding of 3.3kV class Induction Motor (절연파괴시험을 통한 3.3kV 유도전동기의 절연특성 연구)

  • Lee, Dong-Geun;Lee, Kwang-Ho;Choi, Kyo-Nam;Kim, Hyun-Il;Kwak, Hee-Jin;Oh, Bong-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2118-2122
    • /
    • 2005
  • This test was performed to assess the corelation of insulation deterioration condition with breakdown voltage of the stator winding of 3.3kV class induction motors which have been in service for 10 years after being installed in 1993. The insulation diagnostic tests include resistance, polarization index(P.I), dissipation factor$({\Delta}tan{\delta})$, maximum partial discharges (Qmax) and AC breakdown test. we evaluated the corelation of insulation diagnostic test with AC breakdown test for stator wilding of high voltage induction motor.

  • PDF

Evaluation of Insulation Condition for High Voltage Induction Motor (고압유도전동기의 절연상태 평가)

  • Lee, Kwang-Ho;Lim, Jae-Il;Kim, Ki-Won;Jung, Jin-Dal;Lee, Eun-Woong
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.783-785
    • /
    • 2003
  • This test was performed to assess the insulation deterioration condition of the stator winding of 3.3kV class induction motors which have been in service for 15 years after being installed in 1988. The insulation diagnostic tests include resistance, polarization index(P.I). dissipation factor(${\Delta}tan{\delta}$) and maximum partial discharges(Qmax). The results of diagnostic tests were compared to the visual inspection in overhaul.

  • PDF

Assessment of Insulation Condition between Diagnosis and Impregnation for Hydro-Generator (대용량 수차발전기의 절연진단과 절연보수 상관관계 평가)

  • Oh, Bong-Keun;Jung, Jin-Dal;Lee, Kwang-Ho;Kim, Hyun-Il;Kwak, Hee-Jin
    • Proceedings of the KIEE Conference
    • /
    • 2004.05b
    • /
    • pp.39-41
    • /
    • 2004
  • The measurements were performed to assess the insulation deterioration condition of the stator winding of Dae-Cheong hydro-generator #2 which had been in service after being constructed 1980. After repair of the stator winding insulation, we conducted insulation diagnostic tests which include resistance, polarization index(P.I), AC current, dissipation factor($Tan\delta$) and partial discharges ($Q_{max}$). The results of diagnostic tests were compared to the previous records. On the basis of these test results, this paper tried to present the importance of insulation repair for the generator stator winding.

  • PDF

Paraneoplastic demyelination in the brain presenting as a clinically occult non-Hodgkin's lymphoma

  • Son, Hyoshin;Choi, Jongsuk;Kim, Sung Un;Park, Kyung Seok
    • Annals of Clinical Neurophysiology
    • /
    • v.21 no.2
    • /
    • pp.108-112
    • /
    • 2019
  • Non-Hodgkin's lymphoma (NHL) may initially present with atypical neurological manifestations, including paraneoplastic neurological syndromes. Herein, we report the case showing an initial manifestation of systemic NHL with paraneoplastic demyelination in the brain that initially mimicked the symptoms of stroke, seizure, and brain tumor. A high index of suspicion and timely diagnostic workup is required to prevent diagnostic delay and commence proper management of the condition. In this situation, a whole-body FDG PET/CT could be useful to screen for occult malignancy.

Allergic Contact Dermatitis Treated by Sihogyeji-tang Based on Shanghanlun Provisions (『상한론(傷寒論)』 변병진단체계(辨病診斷體系)에 근거하여 시호계지탕(柴胡桂枝湯) 투여 후 호전된 알러지성 피부염 증례 1례)

  • Jeong, Jae-won;Lee, Sung-jun
    • 대한상한금궤의학회지
    • /
    • v.13 no.1
    • /
    • pp.121-132
    • /
    • 2021
  • Objective: This study aimed to report the improvement in a patient with allergic contact dermatitis treated with Sihogyeji-tang based on the Shanghanlun disease pattern identification diagnostic system (DPIDS). Methods: According to the Shanghanlun DPIDS, the patient with allergic contact dermatitis was diagnosed with greater yang disease chest bind (Shanghanlun provision 146), and was administered Sihogyeji-tang for 90 days. The results were evaluated using the Dermatological Life Quality Index (DLQI) and a visual analog scale (VAS). Results: After taking Sihogyeji-tang for 90 days, the DLQI decreased from 28 points to 8 points and the VAS decreased from 10 points to 3 points. Conclusions: This case shows the potential of treatment through herbal medicine for allergic contact dermatitis using the Shanghanlun DPIDS.