• 제목/요약/키워드: Device-to-Device

검색결과 25,316건 처리시간 0.047초

Measuring rheological properties using a slotted plate device

  • Kee, Daniel-De;Kim, Young-Dae;Nguyen, Q. Dzuy
    • Korea-Australia Rheology Journal
    • /
    • 제19권2호
    • /
    • pp.75-80
    • /
    • 2007
  • The slotted plate technique has previously been shown to be a successful method for directly measuring the static yield stress of suspensions. In this study, we further establish the usefulness of the slotted plate device as a rheometer especially at low shear rates, taking advantage of the extremely low speeds of the slotted plate technique. Newtonian fluids, a shear thinning fluid, and yield stress fluids were tested using the slotted plate device and the results were compared with those from a commercial rheometer using different standard flow geometries. The relationship between the stress on the plate and the viscosity for the slotted plate device obtained by dimensional analysis (drag) predicts a linear relationship between the force at the plate and the plate speed, consistent with the experimental data. The slotted plate device can measure viscosities at very low shear rates. The apparent viscosity - shear-rate data obtained from the slotted plate device are complementary to those obtained using a commercial rheometer. That is : the slotted plate can measure viscosity in the shear rate range $10^{-7}<\dot{\gamma}<10^{-3}\;s^{-1}$, while the commercial rheometer measures viscosity at shear rates higher than $10^{-3}\;s^{-1}$.

변형 Roebuck 압축기를 이용한 J-T 네온 냉각시스템의 열역학적 설계 (Thermodynamic Design of J-T Neon Refrigeration System Utilizing Modified Roebuck Compression Device)

  • 정제헌;정상권
    • 설비공학논문집
    • /
    • 제15권5호
    • /
    • pp.432-438
    • /
    • 2003
  • This paper describes a modified Roebuck compression device as a potential compression device of a rotating cryogenic refrigeration system in superconducting machine such as generator or motor. The conventional cryogen transfer method from stationary refrigeration system to rotating system can be eliminated by an on-board cryogenic refrigeration system that utilizes well-designed multi-stage modified Roebuck compression device. This paper shows basic thermodynamic analysis of modified Roebuck compression device and its application for compressing neon at 77 K with substantial pressure ratio when the rotor diameter is 0.8 m with rotating speed of 3600 rpm. The device does not require any moving part in rotating frame, but two separate thermal reservoirs to convert thermal energy into mechanical compression work. The high temperature thermal reservoir is atmospheric environment at 300 K and the low temperature thermal reservoir is assumed as a liquid nitrogen bath at 77 K. The concept of the compression device in this paper demonstrates its usefulness of generating high-pressure neon at 77 K for rotating J-T neon refrigeration cycle of superconducting rotor.

MTM하드웨어 기반 스마트 단말 보안 핵심기술 구현 (Security Core Technology Implementation for MTM Hardware-Based Smart Devices)

  • 김정녀
    • 정보보호학회논문지
    • /
    • 제26권6호
    • /
    • pp.1455-1459
    • /
    • 2016
  • 최근 들어, 스마트 단말에서 지불, 인터넷 뱅킹 등 금융업무와 관련된 중요한 정보들을 다루는 경우가 많아졌다. 또한 스마트 단말의 실행환경이 공개 소프트웨어 환경 위주로 발전하면서, 사용자들이 임의의 응용소프트웨어를 다운받아 사용하는 것이 용이하게 됨에 따라, 스마트 단말이 보안적 측면에서 취약하게 되었다. 본 논문에서는 하드웨어 기반의 스마트 단말 보안 기술의 특징을 알아본다. 또한, 본 논문에서는 스마트 단말에서 실행되는 응용프로그램을 위한 MTM(Mobile Trusted Module) 하드웨어기반의 안전한 스마트 단말 실행환경에 대한 구현방법을 제안한다.

Uniaxial Magnetic Anistotropy of a NiO-Spin Valve Device

  • Lee, Won-Hyung;Hwang, Do-Guwn;Lee, Sang-Suk
    • Journal of Magnetics
    • /
    • 제14권1호
    • /
    • pp.18-22
    • /
    • 2009
  • The shape anisotropy effect of a giant magnetoresistance-spin valves (GMR-SV) device with a glass/NiO/NiFe/CoFe/Cu/CoFe/NiFe layered structure for use in the detection of magnetic property of molecules within a cell was investigated. The patterned device was given uniaxial anisotropy during the sputtering deposition and vacuum post-annealing, which was performed at $200^{\circ}C$ under a 300 Oe magnetic field. The pattern size of the device, which was prepared through the photolithography process, was $2{\times}15\;{\mu}m^2$. The experimental results confirmed that the best design for a GMR-SV device to be used as a biosensor is to have both the axis sensing current and the easy axis of the pinned NiO/NiFe/CoFe triple layer oriented in the direction of the device's width, while the easy axis of the free CoFe/NiFe bilayer should be pointed along the long axis of the device.

도어 안전장치의 구조해석 (Structural Analysis of Door Safety Device)

  • 이종선
    • 한국융합학회논문지
    • /
    • 제10권9호
    • /
    • pp.173-177
    • /
    • 2019
  • 모든 건축물에 사용되고 있는 도어는 안전장치를 부착하지 않아 사고가 빈번하게 발생하고 있으며 어린이에게는 치명적인 손 끼임 사고로 이어진다. 이러한 사고를 방지하기 위한 도어 안전장치를 개발하기 위하여 기존의 도어 안전장치에 대하여 구조해석을 실시하였다. 기존 도어 안전장치의 안전성을 검증하기 위하여 CATIA를 활용하여 모델링하고 도어의 개폐각도는 $95^{\circ}$, $100^{\circ}$, $105^{\circ}$, $110^{\circ}$, $115^{\circ}$, $120^{\circ}$를 고려하였으며 구조해석의 결과로서 변형량, 응력, 변형률 에너지를 구하였다. 이러한 해석결과는 새로운 도어 안전장치를 개발하기 위한 초기자료로 활용되었으며 어린이가 손이 끼이지 않도록 경첩부에 설치하고 반대면은 플라스틱 커버 형태로 개발하여 손 끼임을 방지한다

아동의 학업스트레스, 그릿, 집행기능 곤란 및 미디어기기 과의존 간의 구조적 관계 (Structural Relationship among Children's Academic Stress, Grit, Executive Function Difficulty, and Media Device Addiction)

  • 공영숙;임지영
    • Human Ecology Research
    • /
    • 제59권3호
    • /
    • pp.387-400
    • /
    • 2021
  • This study examined the structural relationship between children's academic stress, grit, executive function difficulty, and media device addiction. Data on 1,132 children and their mothers from the 11th (2018)Panel Study on Korean Children were used for the study. Data were collected by Academic Stress Scale, Grit Scale-Children, Child-Adolescent Self-reported Executive Function Difficulty Screening Questionnaire, and K-Internet Addiction Scale. Data were analyzed using SPSS 25.0 and AMOS 23.0 program with Pearson correlation, structural equation model and bootstrapping. The main results were as follows. 1) Children's academic stress had a negative influence on their grit. 2) Children's grit had a negative influence on their executive function difficulty and media device addiction. 3) Children's executive function difficulty had a positive influence on their media device addiction. 4) The relationship between children's academic stress and media device addiction was mediated by their grit and executive function difficulty. This study is significant in the sense that it found protective factors and risk factors for children's addiction to media devices. We suggest that children's grit be improved, and their academic stress and executive function difficulty be reduced to prevent and mediate children's media device addiction.

Effect of Exercise Using an Automatic Spine Extension Device on Thoracic Kyphotic and Extension Angles

  • Kim, Ju-hyeon;Park, Seon-mi;Sin, Hyang-hee;Choi, Ho-jeong;Liu, Yaoyao;Yoo, Won-gyu
    • 한국전문물리치료학회지
    • /
    • 제29권3호
    • /
    • pp.235-240
    • /
    • 2022
  • Background: A spinal extension and intensive rehabilitation program reduced the symptoms and pain of kyphosis, and improved function. Objects: This study aimed to demonstrate the effect of a spine extension device on the degree of thoracic kyphosis and extension angles, confirm reduction of the kyphosis angle and an increase in flexibility. Methods: Thirteen adults were enrolled in the experiment, using the spine extension device, which was set to passively extend the spine. The angle between the spinous process of the first thoracic vertebra and the spinous process of the twelfth thoracic vertebra was measured by dual inclinometer before and after using the spine extension device. Results: In the static posture, the thoracic kyphosis decreased after using the spine extension device in the thoracic extension posture, and there was a significant difference (p < 0.05); thoracic extension angle increased with statistical significance (p < 0.05). Conclusion: In this study, the thoracic kyphosis angle and thoracic extension angle of the subjects before and after using spine extension device was compared and analyzed, which proved that the spine extension device can effectively improve the mobility of spinal extension.

Exoskeleton 형태의 모션 캡쳐 장치를 이용한 이동로봇의 원격 제어 (Teleoperated Control of a Mobile Robot Using an Exoskeleton-Type Motion Capturing Device Through Wireless Communication)

  • 전풍우;정슬
    • 제어로봇시스템학회논문지
    • /
    • 제10권5호
    • /
    • pp.434-441
    • /
    • 2004
  • In this paper, an exoskeleton-type motion capturing system is designed and implemented. The device is designed to have 12 degree-of-freedom entirely to represent human arm motions. Forward and inverse kinematics of the device are analyzed to make sure of its singular positions. With the designed model parameters, simulation studies are conducted to verify that the designed motion capturing system is effective to represent human motions within the workspace. As a counterpart of the exoskeleton system, a mobile robot is built to follow human motion restrictively. Experimental studies of teleoperation from the exoskeleton device to control the mobile robot are carried out to show feasible application of wireless man-machine interface.

A Dielectrophoresis Microfluidic Device for Trapping Bioparticles at Low Voltage and Frequency

  • Jeong, Jin-Tae;Shin, Hyun-Min;Kim, Duwoon;Lee, Kyeong-Hwan
    • Journal of Biosystems Engineering
    • /
    • 제41권1호
    • /
    • pp.60-65
    • /
    • 2016
  • Purpose: The necessity for precise manipulation of bioparticles has greatly increased in the fields of bioscience, biomedical, and environmental monitoring. Dielectrophoresis (DEP) is considered to be an ideal technique to manipulate bioparticles. The objective of this study is to develop a DEP microfluidic device that can trap fluorescent beads, which mimic bioparticles, at the low voltage and frequency of the sinusoidal signal supplied to the microfluidic device. Methods: A DEP microfluidic device, which is composed of polydimethylsiloxane (PDMS) channels and interdigitated electrode networks, is fabricated to trap fluorescent beads. The geometry of the interdigitated electrodes is determined through computational simulation. To determine the optimum voltage and frequency of the sinusoidal signal supplied to the device, the experiments of trapping beads are conducted at various combinations of voltage and frequency. The performance of the DEP microfluidic device is evaluated by investigating the correlation between fluorescent intensities and bead concentrations. Results: The optimum ratio of the widths between the negative and positive electrodes was 1:4 ($20:80{\mu}m$) at a gap of $20{\mu}m$ between the two electrodes. The DEP electrode networks were fabricated based on this geometry and used for the bead trapping experiments. The optimum voltage and frequency of the supplied signal for trapping fluorescent beads were 15 V and 5 kHz, respectively. The fluorescent intensity of the trapped beads increased linearly as the bead concentration increased. The coefficient of determination ($R^2$) between the fluorescent intensity and the bead concentration was 0.989. Conclusions: It is concluded that the microfluidic device developed in this study is promising for trapping bioparticles, such as a cell or virus, if they are conjugated to beads, and their concentration is quantified.

가속도센서와 기울기센서를 이용한 실시간 낙상 감지 시스템에 관한 연구 (The Study of Realtime Fall Detection System with Accelerometer and Tilt Sensor)

  • 김성현;박진;김동욱;김남균
    • 한국정밀공학회지
    • /
    • 제28권11호
    • /
    • pp.1330-1338
    • /
    • 2011
  • Social activities of the elderly have been increasing as our society progresses toward an aging society. As their activities increase, so does the occurrence of falls that could lead to fractures. Falls are serious health hazards to the elderly. Therefore, development of a device that can detect fall accidents and prevent fracture is essential. In this study, we developed a portable fall detection system for the fracture prevention system of the elderly. The device is intended to detect a fall and activate a second device such as an air bag deployment system that can prevent fracture. The fall detection device contains a 3-axis acceleration sensor and two 2-axis tilt sensors. We measured acceleration and tilt angle of body during fall and activities of daily(ADL) living using the fall detection device that is attached on the subjects'. Moving mattress which is actuated by a pneumatic system was used in fall experiments and it could provide forced falls. Sensor data during fall and ADL were sent to computer and filtered with low-pass filter. The developed fall detection device was successful in detecting a fall about 0.1 second before a severe impact to occur and detecting the direction of the fall to provide enough time and information for the fracture preventive device to be activated. The fall detection device was also able to differentiate fall from ADL such as walking, sitting down, standing up, lying down, and running.