• 제목/요약/키워드: Device-to-Device

검색결과 25,316건 처리시간 0.052초

Development of a Low-cost Metering Device for Automatic Mixing of Nutrient-Solution

  • Ryu, K.H.;Lee, K.C.;Lee, J.H.
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 1996년도 International Conference on Agricultural Machinery Engineering Proceedings
    • /
    • pp.1117-1125
    • /
    • 1996
  • A low-cost and precise metering device, which is suitable to automatic mixing of nutrient-solution for hydroponic culture, was developed for small-scale growers. The metering accuracy of the metering device developed was compared with commercial metering pumps. The mixing performance through the control of EC and pH was also evaluated. The accuracy of the metering device in terms of the full -scale error was $\pm$0.3% , which was much better compared to $\pm$2.45% and $\pm$1.38% for the two types of commercial metering pumps. The mixing system of nutrient-solution with the metering device showed a satisfactory control performance with the accuracies of $\pm$0.05mS/cm and$\pm$0.2pH for EC and pH, respectively.

  • PDF

6축 병렬형 순응기구를 이용한 위치/힘 동시제어 (Kinestatic Control using Six-axis Parallel-type Compliant Device)

  • 김한성
    • 한국생산제조학회지
    • /
    • 제23권5호
    • /
    • pp.421-427
    • /
    • 2014
  • In this paper, the kinestatic control algorithm using a six-axis compliant device is presented. Unlike the traditional control methods using a force/torque sensor with very limited compliance, this method employs a compliant device to provide sufficient compliance between an industrial robot and a rigid environment. This kinestatic control method is used to simply control the position of an industrial robot with twists of compensation, which can be decomposed into twists of compliance and twists of freedom. A simple design method of a six-axis parallel-type compliant device with a diagonal stiffness matrix is presented. A compliant device prototype and kinestatic control hardware system and programming were developed. The effectiveness of the kinestatic control algorithm was verified through two kinds of kinestatic control experiments.

시각장애인들을 위한 무선 정보 전송 시스템 (Wireless Information Transfer System for Blind People)

  • 길기종;손병준;신용빈;김동우;이수진;김종욱
    • 대한임베디드공학회논문지
    • /
    • 제12권1호
    • /
    • pp.63-69
    • /
    • 2017
  • This paper proposes a new device for a portable braille device using Atmega128 and solenoid magnets. This braille device is composed of three panels, and each panel has six solenoid dots. This device aims to help the disabled people who cannot communicate with others. As an application example, when a disabled people approach a traffic light, it sends a message via Bluetooth to the proposed device letting people recognize a dangerous area. The message converted from the database is based on standard braille chart.

의도 고출력 전자파에 의해 오동작 되는 CMOS소자의 전류특성 (Current Characteristics of CMOS device Broken by Intentional High Power Electromagnetic Wave)

  • 황선묵;홍주일;한승문;박신우;허창수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1516-1517
    • /
    • 2007
  • This paper investigated the breakdown effect of the CMOS device by impact of high power electromagnetic wave. The experiments employed a waveguide to study the current characteristics of CMOS device broken by high power electromagnetic wave. The CMOS device were composed of a LED drive circuit for visual discernment. Also CMOS device broken by high power electromagnetic wave was observed by power current. The CMOS device were broke by high power electromagnetic wave at about 10 kV/m and when power current is 75 mA. Based on the result, CMOS devices should show plan to protect the CMOS devices by high power electromagnetic wave. And the database from this experiment should provide the basis for future investigation.

  • PDF

Development of Complex Module Device for Odor Reduction in Sewage

  • KIM, Young-Do;KWON, Woo-Taeg
    • 웰빙융합연구
    • /
    • 제4권3호
    • /
    • pp.1-9
    • /
    • 2021
  • Purpose: This study was conducted to develop a module with higher removal efficiency and effectiveness by adapting two or more deodorization techniques for main cause of odor pollution exposed citizen living near water treatment facilities. Research design, data and methodology: To consider the standard, unity, electrical wire, compatibility of detachable device by installing two types of dry deodorization device within one module for easy replacement. Complex odor, H2S, NH3 were collected from sewage treatment facilities for evaluation of deodorization device. Results: Using the developed application in this study, removal efficiency of complex odor, H2S, NH3 were 93%, 100%, 82%, respectively. Conclusions: The H2S removal efficiency of deodorization device was higher than bio-filter system, which were currently used by sewage treatment. Further, the device should be considered for use in efficient odor removal system.

Correlation between spin density and Vth instability of IGZO thin-film transistors

  • Park, Jee Ho;Lee, Sohyung;Lee, Hee Sung;Kim, Sung Ki;Park, Kwon-Shik;Yoon, Soo-Young
    • Current Applied Physics
    • /
    • 제18권11호
    • /
    • pp.1447-1450
    • /
    • 2018
  • The electron spin resonance (ESR) detects point defect of the In-Ga-Zn oxide (IGZO) like singly ionized oxygen vacancies and excess oxygen, and get spin density as a parameter of defect state. So, we demonstrated the spin density measurement of the IGZO film with various deposition conditions and it has linear relationship. Moreover, we matched the spin density with the total BTS and the threshold voltage ($V_{th}$) distribution of the IGZO thin film transistors. The total BTS ${\Delta}V_{th}$ and the $V_{th}$ distribution were degraded due to the spin density increases. The spin density is the useful indicator to predict $V_{th}$ instability of IGZO TFTs.

ITS 장비 성능시험장 선정기준 및 구축결과 (Results of Developing an ITS Device Performance Test-Bed and Criteria of Its Selection)

  • 이상협;이미영;백남철
    • 대한토목학회논문집
    • /
    • 제26권5D호
    • /
    • pp.703-708
    • /
    • 2006
  • 미국, 일본 등에서는 ITS 장비 성능시험장을 구축하여 정보의 신뢰성 강화, 표준화 및 호환성 확보 등에 활용하고 있다. 본 연구에서는 이러한 외국사례를 검토하여 시험장 선정기준을 제시하고 그에 부합하는 성능시험장을 구축하였으며 ITS 장비 성능시험장의 시범운영을 실시하고 그 시험결과를 분석함으로써 ITS 장비 성능시험장 구축의 중요성을 확인하였다.

회전방지장치와 지대주의 내육각구조가 임플란트로 전달되는 조임 회전력에 미치는 영향 (EFFECT OF A COUNTER-TORQUE DEVICE AND THE INTERNAL HEXAGON OF ABUTMENT ON THE TIGHTENING TORQUE TRANSMITTED TO THE IMPLANT)

  • 이상민;전영찬;정창모
    • 대한치과보철학회지
    • /
    • 제41권2호
    • /
    • pp.223-231
    • /
    • 2003
  • Statement of problem : Little is known about the effect of a counter-torque device and the internal hexagon of abutment on the tightening torque transmitted to the implant. Purpose : The purpose of this study was to examine the effect of a counter-torque device and the internal hexagon of abutment on the tightening torque transmitted to the implant. Material and Methods : In this study, three types of abutment were used, (1) two-piece conical abutment with hexagon, (2) two-piece conical abutment without hexagon, and (3) one-piece conical abutment without hexagon. The experimental groups were divided into five groups according to the type of abutment and the usage of a counter-torque device. Group I : two-piece conical abutment with internal hexagon was tightened without the use of a counter-torque device. Group II : two-piece conical abutment without internal hexagon was tightened without the use of a counter-torque device. Group III : one-piece conical abutment without internal hexagon was tightened without the use of a counter-torque device. Group IV : two-piece conical abutment with internal hexagon was tightened with the use of a counter-torque device Group V : two-piece conical abutment without internal hexagon was tightened with the use of a counter-torque device. Abutments were tightened 20Ncm torque with the use of manual torque wrench and then torque values were measured by torque-gauge. After the measurement of torque values, all groups were loosened with the use of manual torque wrench and then detorque values were measured by torque-gauge. Results : The results were as follows. 1. There were no differences in torque values among three types of abutment. 2. Regardless of the existence of the internal hexagon of abutment, a counter-torque device decreased the tightening torque transmitted to the implant about 92% 3. In group III showed the highest detorque value, however there were no differences among group I, II, IV and V. Conclusion : Within the limitations of this study, it was concluded that the internal hexagon of abutment has no effect on the tightening torque transmitted to the implant and the detorque value of abutment screw. The use of a counter-torque device is essential to prevent microfracture on the implant-bone interface but has no effect on preload.

CX23880 기반 PCI 다채널 비디오/오디오 캡쳐 장치 설계 및 구현 (Design and Implementation of a CX23880 based PCI Multichannel Video/Audio Capture Device)

  • 백승걸;홍진기;정선태
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2003년도 하계종합학술대회 논문집 Ⅳ
    • /
    • pp.2148-2151
    • /
    • 2003
  • In this paper, we present our experiences in designing and implementing a CX23880 based multichannel video/audio capture device. We try to clarify differences between CX2388x family and 878A, the previous version of Cx2388x, and what one needs to be careful about in developing device drivers for CX2388x based video/audio devices. Our work is expected to help one who will need to develop Cx2388x based video/audio device later.

  • PDF

Follow-up Comparison of Two Different Types of Anterior Thoracolumbar Instrumentations in Trauma Cases : Z-plate vs. Kaneda Device

  • Park, Jung-Keun;Kim, Keun-Su
    • Journal of Korean Neurosurgical Society
    • /
    • 제41권2호
    • /
    • pp.77-81
    • /
    • 2007
  • Objective : In a variety of thoracolumbar diseases, corpectomy followed by interbody bone graft and anterior instrumentation has allowed direct neural decompression and reconstruction of the weight-bearing column by short segments fusion. In this study, we compared spinal stability of the two different anterior thoracolumbar instruments : Z-plate and Kaneda device representing plate and two-rods type, respectively. Methods : A retrospective review was performed for all the patients with thoracolumbar diseases or traumas treated with anterior corpectomy, autologous iliac bone graft, and fixation with instruments from 1996 to 2000. For the anterior instrumentation, Z-plate or Kaneda device was used for 24 [M:F=5:9, average age=37] and 12 [M:F=9:3, average age=41] patients, respectively. The plain AP and lateral flexion-extension films were taken immediately after surgery and at each follow-up. The sagittal and coronal Cobb's angles at the operation segments were used to observe the change of initial fixation status. The surgical time length and bleeding amount of the two groups were compared. Intra-operative and post-operative instrument associated complications were evaluated. Student t-test was used for statistical analysis and p-value less than 0.05 was considered to be significant. Results : Mean follow-up durations for Z-plate and Kaneda device were 24 and 21 months, respectively. The fusion rate was 91% for Z-plate and 100% for Kaneda device. Two cases of Z-plate group showed instrumentation failure during the follow up period, in which additional surgery was necessary. The mean differences of sagittal Cobb's angles among the AP images immediate after surgery and at follow-up were 7 and 2 degrees for Z-plate and Kaneda device, respectively [p<0.05]. The mean differences of coronal Cobb's angles were 5 and 2 degrees for Z-plate and Kaneda device, respectively [p<0.05]. No Intra-operative complication has occurred in both groups. There was no difference in surgery time and bleeding amount between two groups. Conclusion : We think that Kaneda device [rod type] is stronger than Z-plate [plate type] to keep the spinal stability after anterior thoracolumbar surgery.