• 제목/요약/키워드: Device-to-Device

검색결과 25,316건 처리시간 0.053초

Exploratory Study on the Success Factors of Rehabilitation Medical Device Cluster

  • Kim, Sung-Jin;Kim, Gyu-Bae
    • 융합경영연구
    • /
    • 제6권4호
    • /
    • pp.17-27
    • /
    • 2018
  • Purpose - As Korea is reaching a post-aged society, the number of chronic illness is increasing, and the demand for rehabilitation medical device is growing. Although there is high potential for the growth in rehabilitation industry, because most of the related companies in Korea are relatively small, lacking capital or R&D resource, it is difficult for them to create an innovative product, and currently most of the high-tech equipments are imported. Therefore a medical device cluster, where business, research, medical institutes and universities may work cooperatively to enhance research development and solve issues is necessary for future development. Research design, data, methodology - In this method we have done a literature review of the rehabilitation industry and industrial cluster. Based on the studies, we have conducted an exploratory factor analysis by studying examples of foreign and domestic medical clusters and drawing success factors in forming a medical cluster. Next based on the studies we have conducted a survey to domestic medical device companies to find their difficulties and needs to form a successful medical device cluster. Results - This paper provides both theoretic review on success factors of forming a medical device cluster and practical analysis using case study and survey. Conclusion - The significance of this paper is that based on the literature review, we have compared actual examples of domestic/foreign medical clusters and drawn difference and coincidence between literature and actual cluster success factor. We were also able to conduct a survey on actual medical device companies and through the results we were able to search difficulties and necessities of medical device companies.

Yaw방향의 보정이 가능한 Tomotherapy couch device의 개발 (Development of Tomotherapy couch device capable of yaw-directional correction)

  • 채문기;권동열;선종률;최병기
    • 대한방사선치료학회지
    • /
    • 제30권1_2호
    • /
    • pp.139-151
    • /
    • 2018
  • 목 적 : "Yaw방향의 보정이 가능한 Tomotherapy couch device"를 자체 제작하였고, 그 유용성을 평가하였다. 대상 및 방법 : 휨 강도가 $200kg/cm^2$의 경질 섬유판 재질로 Yaw방향의 회전 가능한 Tomotherapy couch device를 제작하고, 제작된 device의 물리적 정확성을 판단하기 위해 Varian사의 Novalis Tx의 CBCT Image와 MED-TEC사의 Iso-Align Phantom을 사용하여 device의 Yaw방향의 보정각도의 정확성을 측정하였고, Tomotherapy HDA에서의 치료를 위해 치료계획은 Accuray PrecisionTM를 이용하여 In House Head and Phantom 위에 치료계획을 설계하였고 제작한 device의 보정각도마다 치료 전 후의 MVCT의 adaptive plan을 Accuray PrecisionARTTM and PrecisionTM을 사용하여 선량을 평가하였다. 결 과 : Yaw방향의 보정이 가능한 Tomotherapy couch device를 자체 제작하였으며, 물리적 정확성의 측면에서 모든 각도별 vertical, lateral, longitudinal의 보정값은 약 1 mm 내외였고, 최대 보정값이 1.5 mm를 넘지 않았으며 Yaw방향의 보정은 최대 0.12도 오차 이내의 범위 안에 들어왔다. 치료후의 MVCT촬영 영상을 이용한 adaptive plan을 이용한 선량 평가에서도 모든 각도실험에서 target은 D95=Prescription dose를 만족하고, target내 선량이 95 %~107 % 이내에 들어왔으며, OAR 또한 본원에서 평가한 SMC Head and Neck tolerance dose 영역 내에 모두 들어왔다. 결 론 : 자체 제작한 "Yaw방향의 보정이 가능한 Tomotherapy couch device는 Tomotherapy의 치료에서 Yaw방향의 set-up 오차를 정확히 보정해준다. 비용적인 측면에서도 효과대비 저비용으로 장치를 만들 수 있을 뿐만 아니라 재촬영에 대한 환자가 받는 MVCT image dose를 방지하고 시간적으로도 환자의 회전율을 상승시킬 수 있으며, Yaw방향의 set up 오차를 보정하므로 더 정확한 방사선치료를 시행할 수 있다고 판단된다.

  • PDF

등시지각 색 샘플링에 기반한 $CIEL^{*}a^{*}b^{*}$-CMY로의 비선형 색변환 ($CIEL^{*}a^{*}b^{*}$-CMY nonlinear color transformation based on equi-visual perception color sampling)

  • 류승민;오현수;이철희;유미옥;최환언;안석출
    • 한국인쇄학회지
    • /
    • 제18권1호
    • /
    • pp.103-112
    • /
    • 2000
  • The color space transformation to link device-dependent color spaces and device-independent color spaces is essential for device characterization and cross-media color reproduction. There are various color conversion methods such as regression, 3D interpolation with LUT(look-up table), and neural network. In the color transformation with these methods, the conversion accuracy is essentially based on the sample data to be exploited for device characterization. In conventional method, color samples are uniformly selected in device-dependent space such as CMY and RGB. However, distribution of these color samples is very non-uniform in device-independent color space such as CIEL*a*b*. Accordingly, the conversion error in device-independent color space is irregular according to the distribution of the samples. In this paper, a color sampling method based on equi-visual perception is proposed to obtain approximate uniform color samples in CIEL*a*b* space. In order to evaluate transformation accuracy of proposed method, color space transformations are simulated using regression, 3D interpolation with LUT and neural network techniques, respectively.

  • PDF

휠체어 탑승 장애인을 위한 이동형 체중측정 자동화 장치 개발 (Development of the Portable Weighing Scale Automatic Device for Disabled Wheelchair Users)

  • 장경배;이경완;구도훈
    • 대한임베디드공학회논문지
    • /
    • 제8권1호
    • /
    • pp.61-67
    • /
    • 2013
  • Wheelchair users have a difficulty in managing their weight because there is lack of measure systems and even though the users have the system, it costs too much. Thus, purpose of this study is for developing the portable weight scale automatic device to help wheelchair users by monitoring their weight on the wheelchairs in real time. Portable weight scale automatic device composed by four strain gauges, and the device was connected with mobile phone so that wheelchair users were able to check their weight in real time. In order to evaluate the device performance, 10 normal subjects and 10 disabled subjects participated in this study. The subjects' truth weight and measured weight by the device are compared. The weigh difference within normal subjects was $0.75{\pm}0.80kg$, and the weigh difference within disabled subjects was $1.02{\pm}0.74kg$. Difference between the truth weigh and the measured weigh were not statistically different. The reason for this error occurred is inaccuracy of the loadcell installation and calibration. If this problems get solved, the measured indicator is expected to help wheelchair users to manage their weight.

Debug Port Protection Mechanism for Secure Embedded Devices

  • Park, Keun-Young;Yoo, Sang-Guun;Kim, Ju-Ho
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제12권2호
    • /
    • pp.240-253
    • /
    • 2012
  • In this paper we propose a protection mechanism for the debug port. While debug ports are useful tools for embedded device development and maintenance, they can also become potential attack tools for device hacking in case their usage is permitted to hackers with malicious intentions. The proposed approach prevents illicit use of debug ports by controlling access through user authentication, where the device generates and issues authentication token only to the server-authenticated users. An authentication token includes user access information which represents the user's permitted level of access and the maximum number of authentications allowed using the token. The device authenticates the user with the token and grants limited access based on the user's access level. The proposed approach improves the degree of overall security by removing the need to expose the device's secret key. Availability is also enhanced by not requiring server connection after the initial token generation and further by supporting flexible token transfer among predefined device groups. Low implementation cost is another benefit of the proposed approach, enabling it to be adopted to a wide range of environments in demand of debug port protection.

백회와 사신총 혈위에 적합한 침구 소자의 개발 (The Development of Acupuncture- Moxibustion Device for 4 points around GV20(Baihui))

  • 조봉관
    • 대한한의진단학회지
    • /
    • 제19권2호
    • /
    • pp.101-108
    • /
    • 2015
  • Objectives This paper focused on developing the acupuncture-moxibustion device for head. Disadvantages of the existing devices for head moxibustion are its hume and inconvenience in operating because of the hair. Methods The proposed acupuncture-moxibustion device for GV20(Baihui) is 10mm long as needle body and 6mm long as needle root whose feature are 1~2 turns spiral coil. The spiral coil contains the moxa in order not to drop the moxa while operating Results The direct temperature on the burning moxa were measured by TK-305 infrared thermometer. But the direct temperature on the needle of acupuncture-moxibustion device were not able to measure by TK-305 infrared thermometer. By definition equation, the indirect temperatures on the needle of acupuncture-moxibustion device were able to be calculated. Conclusion A very safe, small and cheap acupuncture-moxibustion device for GV20(Baihui) of head is proposed. It will be useful to generate the heat shock protein and to operate in preventing and curing the Alzheimer's disease.

Bi-directional Two Terminal Switching Device based on SiGe for Spin Transfer Torque (STT) MRAM

  • Yang, Hyung-Jun;Kil, Gyu-Hyun;Lee, Sung-Hyun;Song, Yun-Heub
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제42회 동계 정기 학술대회 초록집
    • /
    • pp.385-385
    • /
    • 2012
  • A two terminal N+/P/N+ junction device to replace the conventional selective transistor was studied as a bilateral switching device for spin transfer torque (STT) MRAM based on 3D device simulation. An N+/P/N+ junction structure with $30{\times}30nm$ area requires bi-directional current flow enough to write a data by a drain induced barrier lowering (DIBL) under a reverse bias at N+/P (or P/N+ junction), and high current on/off ratio of 106. The SiGe materials are widely used in hetero-junction bipolar transistors, bipolar compensation metal-oxide semiconductors (BiCMOS) since the band gap of SiGe materials can be controlled by changing the fraction and the strain epilayers, and the drift mobility is increased with the increasing Ge content. In this work, N+/P/N+ SiGe material based junction provides that drive current is increased from 40 to $130{\mu}A$ by increased Ge content from 10~80%. When Ge content is about 20%, the drive current density of SiGe device substantially increased to 2~3 times better than Si-based junction device in case of 28 nm P length, which is sufficient current to operation of STT-MRAM.

  • PDF

케이블 컨듀잇 구조의 수술용 햅틱 마스터 장치의 개선과 smooth backlash inverse를 이용한 backlash 보정 (Improvement of surgical haptic master device using cable-conduit and backlash compensation by smooth backlash inverse)

  • 최우혁;윤성민;이민철
    • 로봇학회논문지
    • /
    • 제9권1호
    • /
    • pp.48-56
    • /
    • 2014
  • In robotic surgery, a surgeon checks only a surgical site of patient in the progress of surgery by vision and sound information. In order to solve this limited information, the haptic function is necessary. And haptic surgical robot is also necessary to design a haptic master device. The master device for laparoscope operation with cable-conduit was developed in previous research to give haptic function. It suggested a possibility of developing a master device by using the cable-conduit. However, it is very inconvenient to use. Therefore, this paper suggests a new mechanism design structure to solve the problems of the previous work by new forming a new master device. And it has proved that it's usability is better than previous one. Furthermore it has also experimented and analyzed that a backlash of new master device is compensated by smooth backlash inverse algorithm.

Optimal Design of Slider for Stable Flying Characteristics using $4{\times}1$ Near-field Probe Array

  • Jung, Min-Su;Hong, Eo-Jin;Park, Kyoung-Su;Park, No-Cheol;Yang, Hyun-Seok;Park, Young-Pil;Lee, Sung-Q;Park, Kang-Ho
    • 정보저장시스템학회논문집
    • /
    • 제2권1호
    • /
    • pp.65-70
    • /
    • 2006
  • In the information storage development, the trend of the storage device is to increase the recording density. Among such an effort, near-field probe recording is spotlighted as a method of high increasing recording density. For the successfully embodiment of storage device, the actuating mechanism of near-field probe is essentially designed. In this paper, we suggest the slider similar with conventional HDD and design the slider using near-field probe for the purpose of applying the slider in order to control gap between probe and media. The most important object of slider design is to guarantee the flying ability and stability. For achievement of these design objects, we perform two step of optimal design process. The media is supposed to model as random displacement, which is only considered roughness of disk surface. The design slider is analyzed with dynamic state in assumed media. At this process, the optimal model is confirmed to stable flying stability.

  • PDF

뉴로모픽 시스템 향상을 위한 RRAM 기반 시냅스 소자 리뷰 (A Review of RRAM-based Synaptic Device to Improve Neuromorphic Systems)

  • 박건우;김제규;최건우
    • 반도체디스플레이기술학회지
    • /
    • 제21권3호
    • /
    • pp.50-56
    • /
    • 2022
  • In order to process a vast amount of data, there is demand for a new system with higher processing speed and lower energy consumption. To prevent 'memory wall' in von Neumann architecture, RRAM, which is a neuromorphic device, has been researched. In this paper, we summarize the features of RRAM and propose the device structure for characteristic improvement. RRAM operates as a synapse device using a change of resistance. In general, the resistance characteristics of RRAM are nonlinear and random. As synapse device, linearity and uniformity improvement of RRAM is important to improve learning recognition rate because high linearity and uniformity characteristics can achieve high recognition rate. There are many method, such as TEL, barrier layer, NC, high oxidation properties, to improve linearity and uniformity. We proposed a new device structure of TiN/Al doped TaOx/AlOx/Pt that will achieve high recognition rate. Also, with simulation, we prove that the improved properties show a high learning recognition rate.