• 제목/요약/키워드: Device-to-Device

검색결과 25,316건 처리시간 0.058초

만성 감염성 창상에 대한 변형 음압요법과 은이온 제재의 이용 (Application of Modified Vacuum Assisted Closure with Silver Materials in Chronic Infected Wound)

  • 박건욱;정재호
    • Archives of Plastic Surgery
    • /
    • 제35권4호
    • /
    • pp.393-399
    • /
    • 2008
  • Purpose: Chronic infected wounds sustained over 4 weeks with exposed tendon or bone are difficult challenges to plastic surgeons. Vacuum assisted closure (VAC) device has been well used for the management of chronic wounds diminishing wound edema, reducing bacterial colonization, promoting formation of granulation tissue and local blood flow by negative pressure to wounds. But Commercial ready-made VAC device might have some difficulties to use because of its high expenses and heavy weight. So we modified traditional VAC device with silver dressing materials as topical therapeutic agents for control of superimposed bacterial wound infection such as MRSA, MRSE and peudomonas. Methods: We designed the modified VAC device using wall suction, 400 cc Hemovac and combined slow release silver dressing materials. We compared 5 consecutive patients' data treated by commercial ready-made VAC device(Group A) with 11 consecutive patients' data treated by modified VAC device combined with silver dressing materials(group B) from September 2004 to June 2007. Granulation tissue growth, wound discharge, wound culture and wound dressing expenses were compared between the two groups. Results: In comparison of results, no statistical differences were identified in reducing rate of wound size between group A and B. Wound discharge was significantly decreased in both groups. Modified VAC device with silver dressing materials showed advantages of convenience, cost effectiveness and bacterial reversion. Conclusion: In combination of modified VAC device and silver dressing materials, our results demonstrated the usefulness of managing chronic open wounds superimposed bacterial infection, cost effectiveness compared with traditional VAC device and improvement of patient mobility.

백-밸브-마스크 환기증진을 위한 보조기구 개발 및 효과 (Assistant device development and effects for promotion of bag-valve-mask ventilation)

  • 권찬양;이인수
    • 한국응급구조학회지
    • /
    • 제22권1호
    • /
    • pp.49-59
    • /
    • 2018
  • Purpose: The purpose of this study was to develop an assistant device for the promotion of bag-valve-mask ventilation based on a non-equivalent control group pre-test and post-test design. Methods: The experimental tool was a mask assistance device developed by the researchers. Data were analyzed using SPSS 21.0 with the cardiopulmonary resuscitation (CPR) evaluation program from August 18 to 30, 2016. The research tools included general, hand-related, and ventilation-related characteristics. Results: Before and after using the mask assistance device, the tidal volume increased by 64 mL (p<.001) from 461.76 mL to 525.86 mL. The tidal volume for control was 477.86 mL, and there was a statistical difference (p<.05). The ventilation frequency in device users was 10 times per minute for a total of 20 ventilations with before 10.65 after 10 times, and that of the control group was before 10.36 times after 10 times; there was no difference in both groups(p>.05). The accuracy of the assistance device was $81.72{\pm}30.86%$, which was a very high value. However, the accuracy of ventilation in the control group with no assistance device was $18.97{\pm}32.44%$, which was a very low accuracy rate. Conclusion: This study's results suggested utilizing the newly-developed mask assistance device in CPR, and showed increases in tidal volume and accuracy of ventilation using the bag-valve-mask ventilation equipment. The general and hand-related characteristics did not have any effect, so the use of the device proved to increase the efficacy in all users.

선별적 적용을 통한 의료기기 공급내역보고 제도 개선 연구 (A Study on the Improvement of the Reports on Details of Supply of Medical Device System Through Selective Application)

  • 정현주;임수연;김주완;장원석;권병주
    • 대한의용생체공학회:의공학회지
    • /
    • 제44권5호
    • /
    • pp.315-323
    • /
    • 2023
  • The objective of this study is to identify the selective application targets for reporting on details of supply of class 1 and 2 medical devices as part of the improvement of the reports on details of supply of medical device system, and to analyze its effectiveness. Therapeutic materials covered by health insurance and secondhand medical devices were chosen based on the transparency of health insurance coverage and the management of medical device distribution. As a result, approximately 85% of groups can be excluded from the reporting requirements compared to reporting all items under Class 1 and 2 medical devices. This is expected to enhance the efficiency of supply reporting tasks. Additionally, the information on supply details managed by the regulatory authority can be utilized for statistical analysis and periodic monitoring, serving as fundamental data for the development of medical device-related policies and research in the field of medical devices.

Highly Manufacturable 65nm McFET (Multi-channel Field Effect Transistor) SRAM Cell with Extremely High Performance

  • Kim, Sung-Min;Yoon, Eun-Jung;Kim, Min-Sang;Li, Ming;Oh, Chang-Woo;Lee, Sung-Young;Yeo, Kyoung-Hwan;Kim, Sung-Hwan;Choe, Dong-Uk;Suk, Sung-Dae;Kim, Dong-Won;Park, Dong-Gun
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제6권1호
    • /
    • pp.22-29
    • /
    • 2006
  • We demonstrate highly manufacturable Multi-channel Field Effect Transistor (McFET) on bulk Si wafer. McFET shows excellent transistor characteristics, such as $5{\sim}6 times higher drive current than planar MOSFET, ideal subthreshold swing, low drain induced barrier lowering (DIBL) without pocket implantation and negligible body bias dependency, maintaining the same source/drain resistance as that of a planar transistor due to the unique feature of McFET. And suitable threshold voltage ($V_T$) for SRAM operation and high static noise margin (SNM) are achieved by using TiN metal gate electrode.

의료기기 허가·신고·심사 등에 관한 규정 변화와 전망 : 한의 의료기기 중심으로 (Changes and Perspects in the Regulation on Medical Device Approval Report Review, etc. : Focus on Traditional Korean Medical Devices)

  • 김대진;최병희;김태영;정성희;강우석
    • 대한예방한의학회지
    • /
    • 제28권1호
    • /
    • pp.31-42
    • /
    • 2024
  • Objective : In order to understand the changes in domestic approval regulations applicable to traditional Korean medical device companies, this article will explain the major amendments 「Regulation on Medical Device Approval Report Review, etc.」 from 2005 to the present on a year-by-year basis, and provide a counter plan to the recent changes in approval regulations. Methods : We analysed the changes in approval regulatory amendments related to the traditional Korean medical devices from 2005 to the present. Results : The Ministry of Food and Drug Safety is continuously improving medical device approval regulations to ensure the global competitiveness of domestic medical devices and contribute to the improvement of public health. Recent major approval regulatory amendments include the establishment of a review system for software medical devices and digital therapeutics, the recognition of real world evidence materials, the introduction of a biological evaluation of medical devices within a risk management process and a medical device approval licence renewal system. Conclusions : It is expected that the range of medical devices available to Korean medicine doctors will continue to expand in the future through the provision of non-face-to-face medical services and the development of advanced and new medical devices, as well as wearable medical devices and digital therapeutics. In order to increase the market entry potential of traditional Korean medical devices that incorporate advanced technologies such as digital technology and AI-based diagnosis and prediction technology, it is urgent that the government provide significant support to traditional Korean medical device companies to improve approval regulatory compliance.

망간단괴 집광기 주위 해수 유동교란 수치해석 (Numerical Analysis of Deep Seawater Flow Disturbance Characteristics Near the Manganese Nodule Mining Device)

  • 임성진;채용배;정신택;조홍연;이상호
    • Ocean and Polar Research
    • /
    • 제36권4호
    • /
    • pp.475-485
    • /
    • 2014
  • Seawater flow characteristics around a manganese nodule mining device in deep sea were analyzed through numerical investigation. The mining device influences the seawater flow field with complicated velocity distributions, and they are largely dependent on the seawater flow speed, device moving speed, and injection velocity from the collecting part. The flow velocity and turbulent kinetic energy distributions are compared at several positions from the device rear, side, and top, and it is possible to predict the distance from which the mining device affects the seawater flow field through the variation of turbulent kinetic energy. With the operation of the collecting device the turbulent kinetic energy remarkably increases, and it gradually decreases along the seawater flow direction. Turbulent kinetic energy behind the mining system increases with the seawater flow velocity. The transient behavior of nodule particles, which are not collected, is also predicted. This study will be helpful in creating an optimal design for a manganese nodule collecting device that can operate efficiently and which is eco-friendly.

이식 가능한 RTOS용 Character LCD 디바이스 드라이버 (Portable RTOS Character LCD Device Driver)

  • 홍정환
    • 한국컴퓨터정보학회지
    • /
    • 제14권2호
    • /
    • pp.153-158
    • /
    • 2006
  • 임베디드 소프트웨어(embedded software)에서 디바이스 드라이버(device driver)는 하드웨어와 운영체제 및 응용 프로그램 사이의 연결고리 역할을 하는 핵심 구성 요소로서, 응용 프로그램이 하드웨어에서 제공하는 기능을 사용할 수 있도록 제어 및 상호동작을 위한 일관된 인터페이스를 제공하는 소프트웨어이다. 이러한 디바이스 드라이버는 하드웨어와 소프트웨어의 양쪽 측면에 모두 관련이 있어서 개발이 어렵기 때문에 하드웨어 플랫폼이 바뀔 때마다 새로 작성하는 것은 굉장한 손실이다. 따라서 본 논문에서는 이기종의 하드웨어에서도 쉽게 이식 가능한 디바이스 드라이버 개발방법에 대해 살펴보고 효율적인 디바이스 드라이버 모델 개발방법에 대해 제안한다.

  • PDF

로드셀과 토크암을 이용한 대용량 토크 측정장치 개발에 관한 연구 (Development of device measuring very high torque via torque arm with attached load cells)

  • 이용범;한승호
    • 유공압시스템학회논문집
    • /
    • 제7권1호
    • /
    • pp.6-10
    • /
    • 2010
  • A measurement of very high torque for track drive unit in construction equipment is usually in difficulties due to the requirement of a torque meter with high capacity, and the limitation of geometry for an experimental set-up. To improve the troublesome problem, a new device was proposed, where a torque transmitted through the torque arm can be measured by load cells attached at each torque arm. The experimental set-up of the new device was carried out in order to measure the torque values for a mechanical feedback type planetary gear box, in which the power flow circulates itself in a closed-loop. The new device enables to measure torque values of 60,000Nm. Additionally, the measured values were estimated statistically in the aspect of their repeatability and reproducibility, so that an acceptable behaviour as a measuring device can be confirmed.

  • PDF

전력 Switching 소자를 압전트랜스로 구동하는 방법 (The Driving Method of Power Switching Device Using Pizoelectric Transformer)

  • 황민규;이상균;이재춘;최준영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 D
    • /
    • pp.1324-1326
    • /
    • 1998
  • To drive motor or heating machine, it needs the electric power system like the apparatus of inverter. This electric power system obviously comprises power switching devices and drivers to run them. And this system has the topology comprised one/many arm(s), - each arm has high side switching device and low side switching device. Transformer, photocoupler, and HVIC having functions of isolation and level shift which are important thing to drive high side switching device are used as component of drivers in conventional apparatus. Piezoelectric transformers are proposed in this paper, and applied to drive high side swiching device. Through experiments, the possiblities of driving high side switching device are presented and the problems are mooted concurrently. But, we also consider a counterplan for solving the mooted trouble issues.

  • PDF

Distributed Control with Varying Time Delay in Virtual Device Network

  • Kiwon Song;Kim, Jonghwi;Park, Gi-Sang;Park, Gi-Heung
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2002년도 ICCAS
    • /
    • pp.118.1-118
    • /
    • 2002
  • Recent trends in internet access to the device network require that information be provided from anywhere in the enterprise. One then needs to integrate both device network protocol and data network protocol to realize Virtual Device Network (VDN). Interoperability between devices and equipments is essential to enhance the quality and the performance of VDN. LonWorks technology is incorporated as device network protocol for interoperability. VDN integrating both device network and data network has varying time delay. Inherent varying time delay of VDN can significantly degrade the reliability of Distributed Control System. This study investigates the transmission characteristics of VDN and s...

  • PDF