• Title/Summary/Keyword: Device-to-Device

Search Result 25,369, Processing Time 0.043 seconds

Development of Direct Measurement Device for Alveolar Breath Carbon Monoxide

  • Jo, Wan-Kuen;Oh, Jee-Won
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.18 no.E4
    • /
    • pp.181-190
    • /
    • 2002
  • A novel portable device for the direct measurement of alveolar breath carbon monoxide (CO) was developed. The major components of the device include a mouthpiece, non-rebreathing two-way valve, Teflon tube, and CO dosimeter. An alveolar CO measurement can be completed within 1.5 min when using the proposed device and measurement protocol. Measurements could be read to the nearest 0.1 ppm. Humidity did not influence the CO measurements taken by the CO dosimeter, plus there were no problems associated with the recovery and carryover of CO through the device. The criterion for significance in statistical analyses was p< 0.05. The average recovery was 103 and 99% for recovery and carryover experiments, respectively. Test results using the proposed alveolar CO measurement system reflected a good reproducibility. This reproducibility was also supported by the finding that the relative standard deviations (RSDs) of the data sets were less than 7% for the loss experiment and less than 8% for the carryover experiment. Consequently, it would appear that the proposed device can be effectively applied to measure CO levels found in breath, thereby overcoming several disadvantages associated with the conventional bag and adsorbent tube sampling methods.

Measuring rheological properties using a slotted plate device

  • Kee, Daniel-De;Kim, Young-Dae;Nguyen, Q. Dzuy
    • Korea-Australia Rheology Journal
    • /
    • v.19 no.2
    • /
    • pp.75-80
    • /
    • 2007
  • The slotted plate technique has previously been shown to be a successful method for directly measuring the static yield stress of suspensions. In this study, we further establish the usefulness of the slotted plate device as a rheometer especially at low shear rates, taking advantage of the extremely low speeds of the slotted plate technique. Newtonian fluids, a shear thinning fluid, and yield stress fluids were tested using the slotted plate device and the results were compared with those from a commercial rheometer using different standard flow geometries. The relationship between the stress on the plate and the viscosity for the slotted plate device obtained by dimensional analysis (drag) predicts a linear relationship between the force at the plate and the plate speed, consistent with the experimental data. The slotted plate device can measure viscosities at very low shear rates. The apparent viscosity - shear-rate data obtained from the slotted plate device are complementary to those obtained using a commercial rheometer. That is : the slotted plate can measure viscosity in the shear rate range $10^{-7}<\dot{\gamma}<10^{-3}\;s^{-1}$, while the commercial rheometer measures viscosity at shear rates higher than $10^{-3}\;s^{-1}$.

Thermodynamic Design of J-T Neon Refrigeration System Utilizing Modified Roebuck Compression Device (변형 Roebuck 압축기를 이용한 J-T 네온 냉각시스템의 열역학적 설계)

  • 정제헌;정상권
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.5
    • /
    • pp.432-438
    • /
    • 2003
  • This paper describes a modified Roebuck compression device as a potential compression device of a rotating cryogenic refrigeration system in superconducting machine such as generator or motor. The conventional cryogen transfer method from stationary refrigeration system to rotating system can be eliminated by an on-board cryogenic refrigeration system that utilizes well-designed multi-stage modified Roebuck compression device. This paper shows basic thermodynamic analysis of modified Roebuck compression device and its application for compressing neon at 77 K with substantial pressure ratio when the rotor diameter is 0.8 m with rotating speed of 3600 rpm. The device does not require any moving part in rotating frame, but two separate thermal reservoirs to convert thermal energy into mechanical compression work. The high temperature thermal reservoir is atmospheric environment at 300 K and the low temperature thermal reservoir is assumed as a liquid nitrogen bath at 77 K. The concept of the compression device in this paper demonstrates its usefulness of generating high-pressure neon at 77 K for rotating J-T neon refrigeration cycle of superconducting rotor.

Security Core Technology Implementation for MTM Hardware-Based Smart Devices (MTM하드웨어 기반 스마트 단말 보안 핵심기술 구현)

  • Kim, Jeong Nyeo
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.26 no.6
    • /
    • pp.1455-1459
    • /
    • 2016
  • Recently, the frequency of dealing important information regarding financial services like paying through smart device or internet banking on smart device has been increasing. Also, with the development of smart device execution environment towards open software environment, it became easier for users to download and use random application software, and its security aspect appears to be weakening. This study will inspect features of hardware-based smart device security technology. Furthermore, this study will propose a realization method in MTM hardware-based secure smart device execution environment for application software runs that in smart device.

Uniaxial Magnetic Anistotropy of a NiO-Spin Valve Device

  • Lee, Won-Hyung;Hwang, Do-Guwn;Lee, Sang-Suk
    • Journal of Magnetics
    • /
    • v.14 no.1
    • /
    • pp.18-22
    • /
    • 2009
  • The shape anisotropy effect of a giant magnetoresistance-spin valves (GMR-SV) device with a glass/NiO/NiFe/CoFe/Cu/CoFe/NiFe layered structure for use in the detection of magnetic property of molecules within a cell was investigated. The patterned device was given uniaxial anisotropy during the sputtering deposition and vacuum post-annealing, which was performed at $200^{\circ}C$ under a 300 Oe magnetic field. The pattern size of the device, which was prepared through the photolithography process, was $2{\times}15\;{\mu}m^2$. The experimental results confirmed that the best design for a GMR-SV device to be used as a biosensor is to have both the axis sensing current and the easy axis of the pinned NiO/NiFe/CoFe triple layer oriented in the direction of the device's width, while the easy axis of the free CoFe/NiFe bilayer should be pointed along the long axis of the device.

Structural Analysis of Door Safety Device (도어 안전장치의 구조해석)

  • Lee, Jong-sun
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.9
    • /
    • pp.173-177
    • /
    • 2019
  • This study is door safety device for the structural analysis are described. Recently emerged as a key point of the door safety and increase the need of a door safety device. In order to improvement this inconvenience, the door safety device was design and structural analysis by using CATIA. CATIA utilizes door safety device element model for displacement, stress and strain energy were obtained. Consideration of door open angles were $95^{\circ}$, $100^{\circ}$, $105^{\circ}$, $110^{\circ}$, $115^{\circ}$, $120^{\circ}$. These results will be provided to develop new concepts of door safety device as initial data.

Structural Relationship among Children's Academic Stress, Grit, Executive Function Difficulty, and Media Device Addiction (아동의 학업스트레스, 그릿, 집행기능 곤란 및 미디어기기 과의존 간의 구조적 관계)

  • Kong, Youngsook;Lim, Jiyoung
    • Human Ecology Research
    • /
    • v.59 no.3
    • /
    • pp.387-400
    • /
    • 2021
  • This study examined the structural relationship between children's academic stress, grit, executive function difficulty, and media device addiction. Data on 1,132 children and their mothers from the 11th (2018)Panel Study on Korean Children were used for the study. Data were collected by Academic Stress Scale, Grit Scale-Children, Child-Adolescent Self-reported Executive Function Difficulty Screening Questionnaire, and K-Internet Addiction Scale. Data were analyzed using SPSS 25.0 and AMOS 23.0 program with Pearson correlation, structural equation model and bootstrapping. The main results were as follows. 1) Children's academic stress had a negative influence on their grit. 2) Children's grit had a negative influence on their executive function difficulty and media device addiction. 3) Children's executive function difficulty had a positive influence on their media device addiction. 4) The relationship between children's academic stress and media device addiction was mediated by their grit and executive function difficulty. This study is significant in the sense that it found protective factors and risk factors for children's addiction to media devices. We suggest that children's grit be improved, and their academic stress and executive function difficulty be reduced to prevent and mediate children's media device addiction.

Effect of Exercise Using an Automatic Spine Extension Device on Thoracic Kyphotic and Extension Angles

  • Kim, Ju-hyeon;Park, Seon-mi;Sin, Hyang-hee;Choi, Ho-jeong;Liu, Yaoyao;Yoo, Won-gyu
    • Physical Therapy Korea
    • /
    • v.29 no.3
    • /
    • pp.235-240
    • /
    • 2022
  • Background: A spinal extension and intensive rehabilitation program reduced the symptoms and pain of kyphosis, and improved function. Objects: This study aimed to demonstrate the effect of a spine extension device on the degree of thoracic kyphosis and extension angles, confirm reduction of the kyphosis angle and an increase in flexibility. Methods: Thirteen adults were enrolled in the experiment, using the spine extension device, which was set to passively extend the spine. The angle between the spinous process of the first thoracic vertebra and the spinous process of the twelfth thoracic vertebra was measured by dual inclinometer before and after using the spine extension device. Results: In the static posture, the thoracic kyphosis decreased after using the spine extension device in the thoracic extension posture, and there was a significant difference (p < 0.05); thoracic extension angle increased with statistical significance (p < 0.05). Conclusion: In this study, the thoracic kyphosis angle and thoracic extension angle of the subjects before and after using spine extension device was compared and analyzed, which proved that the spine extension device can effectively improve the mobility of spinal extension.

Teleoperated Control of a Mobile Robot Using an Exoskeleton-Type Motion Capturing Device Through Wireless Communication (Exoskeleton 형태의 모션 캡쳐 장치를 이용한 이동로봇의 원격 제어)

  • Jeon, Poong-Woo;Jung, Seul
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.10 no.5
    • /
    • pp.434-441
    • /
    • 2004
  • In this paper, an exoskeleton-type motion capturing system is designed and implemented. The device is designed to have 12 degree-of-freedom entirely to represent human arm motions. Forward and inverse kinematics of the device are analyzed to make sure of its singular positions. With the designed model parameters, simulation studies are conducted to verify that the designed motion capturing system is effective to represent human motions within the workspace. As a counterpart of the exoskeleton system, a mobile robot is built to follow human motion restrictively. Experimental studies of teleoperation from the exoskeleton device to control the mobile robot are carried out to show feasible application of wireless man-machine interface.

A Dielectrophoresis Microfluidic Device for Trapping Bioparticles at Low Voltage and Frequency

  • Jeong, Jin-Tae;Shin, Hyun-Min;Kim, Duwoon;Lee, Kyeong-Hwan
    • Journal of Biosystems Engineering
    • /
    • v.41 no.1
    • /
    • pp.60-65
    • /
    • 2016
  • Purpose: The necessity for precise manipulation of bioparticles has greatly increased in the fields of bioscience, biomedical, and environmental monitoring. Dielectrophoresis (DEP) is considered to be an ideal technique to manipulate bioparticles. The objective of this study is to develop a DEP microfluidic device that can trap fluorescent beads, which mimic bioparticles, at the low voltage and frequency of the sinusoidal signal supplied to the microfluidic device. Methods: A DEP microfluidic device, which is composed of polydimethylsiloxane (PDMS) channels and interdigitated electrode networks, is fabricated to trap fluorescent beads. The geometry of the interdigitated electrodes is determined through computational simulation. To determine the optimum voltage and frequency of the sinusoidal signal supplied to the device, the experiments of trapping beads are conducted at various combinations of voltage and frequency. The performance of the DEP microfluidic device is evaluated by investigating the correlation between fluorescent intensities and bead concentrations. Results: The optimum ratio of the widths between the negative and positive electrodes was 1:4 ($20:80{\mu}m$) at a gap of $20{\mu}m$ between the two electrodes. The DEP electrode networks were fabricated based on this geometry and used for the bead trapping experiments. The optimum voltage and frequency of the supplied signal for trapping fluorescent beads were 15 V and 5 kHz, respectively. The fluorescent intensity of the trapped beads increased linearly as the bead concentration increased. The coefficient of determination ($R^2$) between the fluorescent intensity and the bead concentration was 0.989. Conclusions: It is concluded that the microfluidic device developed in this study is promising for trapping bioparticles, such as a cell or virus, if they are conjugated to beads, and their concentration is quantified.