• Title/Summary/Keyword: Device-free

Search Result 667, Processing Time 0.028 seconds

Effect of underlayer electroless Ni-P plating on deposition behavior of cyanide-free electroless Au plating (비시안 무전해 Au 도금의 석출거동에 미치는 하지층 무전해 Ni-P 도금 조건의 영향)

  • Kim, DongHyun;Han, Jaeho
    • Journal of the Korean institute of surface engineering
    • /
    • v.55 no.5
    • /
    • pp.299-307
    • /
    • 2022
  • Gold plating is used as a coating of connector in printed circuit boards, ceramic integrated circuit packages, semiconductor devices and so on, because the film has excellent electric conductivity, solderability and chemical properties such as durability to acid and other chemicals. In most cases, internal connection between device and package and external terminals for connecting packaging and printed circuit board are electroless Ni-P plating followed by immersion Au plating (ENIG) to ensure connection reliability. The deposition behavior and film properties of electroless Au plating are affected by P content, grain size and mixed impurity components in the electroless Ni-P alloy film used as the underlayer plating. In this study, the correlation between electroless nickel plating used as a underlayer layer and cyanide-free electroless Au plating using thiomalic acid as a complexing agent and aminoethanethiol as a reducing agent was investigated.

Implementation of Cost-effective Common Path Spectral Domain Free-hand Scanning OCT System

  • Shoujing Guo;Xuan Liu;Jin U. Kang
    • Current Optics and Photonics
    • /
    • v.7 no.2
    • /
    • pp.176-182
    • /
    • 2023
  • Optical coherence tomography (OCT) is being developed to guide various ophthalmic surgical procedures. However, the high cost of the intraoperative OCT system limits its availability mostly to the largest hospitals and healthcare systems. In this paper, we present a design and evaluation of a low-cost intraoperative common-path free-hand scanning OCT system. The lensed fiber imaging probe is designed and fabricated for intraocular use and the free-hand scanning algorithm that could operate at a low scanning speed was developed. Since the system operates at low frequencies, the cost of the overall system is significantly lower than other commercial intraoperative OCT systems. The assembled system is characterized and shows that it meets the design specifications. The handheld OCT imaging probe is tested on multilayer tape phantom and ex-vivo porcine eyes. The results show that the system could be used as an intraoperative intraocular OCT imaging device.

Schottky Barrier Free Contacts in Graphene/MoS2 Field-Effect-Transistor

  • Qiu, Dongri;Kim, Eun Kyu
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2015.08a
    • /
    • pp.209.2-209.2
    • /
    • 2015
  • Two dimensional layered materials, such as transition metal dichalcogenides (TMDs) family have been attracted significant attention due to novel physical and chemical properties. Among them, molybdenum disulfide ($MoS_2$) has novel physical phenomena such as absence of dangling bonds, lack of inversion symmetry, valley degrees of freedom. Previous studies have shown that the interface of metal/$MoS_2$ contacts significantly affects device performance due to presence of a scalable Schottky barrier height at their interface, resulting voltage drops and restricting carrier injection. In this study, we report a new device structure by using few-layer graphene as the bottom interconnections, in order to offer Schottky barrier free contact to bi-layer $MoS_2$. The fabrication of process start with mechanically exfoliates bulk graphite that served as the source/drain electrodes. The semiconducting $MoS_2$ flake was deposited onto a $SiO_2$ (280 nm-thick)/Si substrate in which graphene electrodes were pre-deposited. To evaluate the barrier height of contact, we employed thermionic-emission theory to describe our experimental findings. We demonstrate that, the Schottky barrier height dramatically decreases from 300 to 0 meV as function of gate voltages, and further becomes negative values. Our findings suggested that, few-layer graphene could be able to realize ohmic contact and to provide new opportunities in ohmic formations.

  • PDF

Numerical Analysis of Chamber Flow and Wave Energy Conversion Efficiency of a Bottom-mounted Oscillating Water Column Wave Power Device (고정식 진동수주형 파력 발전장치의 챔버 유동 및 파에너지 변환효율 해석)

  • Koo, Weon-Cheol;Kim, Moo-Hyun;Choi, Yoon-Rak
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.47 no.3
    • /
    • pp.388-397
    • /
    • 2010
  • A two-dimensional time-domain, potential-theory-based fully nonlinear numerical wave tank (NWT) was developed by using boundary element method and the mixed Eulerian-Lagrangian (MEL) approach for free-surface node treatment. The NWT was applied to prediction of primary wave energy conversion efficiency of a bottom-mounted oscillating water column (OWC) wave power device. The nonlinear free-surface condition inside the chamber was specially devised to represent the pneumatic pressure due to airflow velocity and viscous energy loss at the chamber entrance due to wave column motion. The newly developed NWT technique was verified through comparison with given experimental results. The maximum energy extraction was estimated with various chamber-air duct volume ratios.

Development of a Miniature Pendular Type Impact Testing Machine Using a Magnetic Powder Brake (마그네틱 파우더 브레이크를 이용한 소형 진자형 충격시험기 개발)

  • You, In-Dong;Lee, Man-Suk;Kim, Ho-Kyung
    • Tribology and Lubricants
    • /
    • v.27 no.3
    • /
    • pp.140-146
    • /
    • 2011
  • A miniature pendular type impact testing machine was designed and developed, adopting a magnetic powder brake in order to investigate tensile and shear behavior of a small solder ball at high speed. In this testing system, the potential energy of the pendulum is transferred into the impact energy during its drop. Then, the impact energy is transmitted through the striker which is connected to the push rods to push the specimen for tensile loading. The tensile behavior of lead-free solder ball in diameter of 760 ${\mu}m$ was successfully investigated in a speed range of 0.15 m/s~1.25 m/s using this designed device. The maximum tensile strength of the solder joint decreases with the loading speed in the testing condition. The maximum tensile strength of the joint was 56 MPa in the low speed region.

A Study on Droplet Formation from Piezo Inkjet Print Head (피에조 잉크젯 헤드에서 액적 토출 현상에 대한 연구)

  • Oh Se-Young;Lee Jung-Yong;Lee Yu-Seop;Chung Jae-Woo;Wee Sang-Kwon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.10 s.253
    • /
    • pp.1003-1011
    • /
    • 2006
  • Droplets are ejected onto a substrate through a nozzle by pushing liquids in flow channels of drop-on-demand devices. The behavior of ejection and formation of droplets is investigated to enhance the physical understanding of the hydrodynamics involved in inkjet printing. The free surface phenomenon of a droplet is described using $CFD-ACE^{TM}$ which employs the volume-of-fluid (VOF) method with the piecewise linear interface construction (PLIC). Droplet formation characteristics are analyzed in various flow regimes with different Ohnesorge numbers. The computational results show that the droplet formations are strongly dependent on the physical properties of working fluids and the inlet flow conditions. In addition, the wetting characteristics of working fluids on a nozzle influence the volume and velocity of a droplet produced in the device. This study may provide an insight into how a liquid droplet is formed and ejected in a piezoelectric inkjet printing device.

Separation of Lentil Lectin Using Free-Flow Electrophoresis (자유유동 전기이동을 이용한 Lentil Lectin의 분리)

  • 류화원;이동일장호남
    • KSBB Journal
    • /
    • v.9 no.2
    • /
    • pp.115-121
    • /
    • 1994
  • A Purification device with 30-channel free-flow electrophoresis was assembled to treat samples of 240m1 volume for purification of lentil lectin (LcH) from lentil seeds with no impurities in a silverstained PAGIEF gel. HEPES(50mM)-Ttis(50mM), Cycloserine(50mM)-urea(3M), Histidine(50mM)-urea(3M) were used as ampholytea among which Histidine(50mM)-urea(3M) (pI 7.65) was found best in resolution. LcH is known to be present in the form of LcH-A, LcH-B and the complex of the two. The complex, however, disappeared when urea was added in the ampholytes, which suggested that the complete purification of two isolectins is possible using the present multistep purificaton device.

  • PDF

Electrical breakdown free SWCNT thin film transistors on flexible polyimide substrate

  • Park, Jae-Hyeon;Ha, Jeong-Suk
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.58-58
    • /
    • 2010
  • Carbon nanotubes (CNTs) have been extensively studied owing to its superior electrical properties, especially high electron mobility, which can be applied to various nano-electronic devices. However, synthesized CNTs have a mixture of metallic and semiconducting tubes so that their separation has been a tremendous obstacle to the practical application in electronic device structures. Among the different separation methods, electrical breakdown process to selectively burn out the metallic tubes has been quite successful though it needs additional process in the fabrication of device structures. Here, we report on the selective but not perfect growth of semiconducting nanotubes via use of diluted ferritin catalyst. SWCNTs were grown on ferritin catalyst, where the concentration of the ferritin solution was changed. In this way, we could fabricate the electrical breakdown free SWCNT thin film transistors on the flexible polyimide (PI) substrate. When we used the ferritin diluted by 1/2000, ~ 60 % of the SWCNT thin film transistors showed a perfect p-type behavior with an on/off current ratio higher than $10^5$ and on-current greater than $10^{-7}$ A. We will also discuss the photo-response of such formed thin film transistors over both visible and UV light.

  • PDF

Size-based separation of microscale droplets by surface acoustic wave-induced acoustic radiation force (표면파 유도 음향방사력을 이용한 미세액적의 크기 선별)

  • Mushtaq, Ali;Beomseok, Cha;Muhammad, Soban Khan;Hyunwoo, Jeon;Song Ha, Lee;Woohyuk, Kim;Jeongu, Ko;Jinsoo, Park
    • Journal of the Korean Society of Visualization
    • /
    • v.20 no.3
    • /
    • pp.19-26
    • /
    • 2022
  • In droplet microfluidics, precise droplet manipulation is required in numerous applications. This study presents ultrasonic surface acoustic wave (USAW)-based microfluidic device for label-free droplet separation based on size. The proposed device is composed of a slanted-finger interdigital transducer on a piezoelectric substrate and a polydimethylsiloxane microchannel placed on the substrate. The microchannel is aligned in the cross-type configuration where the USAWs propagate in a perpendicular direction to the flow in the microchannel. When droplets are exposed to an acoustic field, they experience the USAW-induced acoustic radiation force (ARF), whose magnitude varies depending on the droplet size. We modeled the USAW-induced ARF based on ray acoustics and conducted a series of experiments to separate different-sized droplets. We found that the experimental results were in good agreement with the theoretical estimation. We believe that the proposed method will serve as a promising tool for size-based droplet separation in a label-free manner.

The Effects of Cognitive Training Using Application Games of Smart Device on Cognitive Function in Patients With Mild Traumatic Brain Injury (스마트기기 애플리케이션 게임을 이용한 인지훈련이 경미한 손상이 있는 외상성 뇌손상 환자의 인지기능에 미치는 영향)

  • Kang, Seon-Hwa;Kim, Young-Sil;Kang, So-La;Moon, Jong-Hoon
    • Journal of Korean Society of Neurocognitive Rehabilitation
    • /
    • v.10 no.2
    • /
    • pp.9-18
    • /
    • 2018
  • The research has sought to examine the effect of cognition training using smart device application games on the cognition function of traumatic brain injury patients. The research was conducted to the seventeen traumatic brain injury patients with slight symptoms who were treated with occupational therapy. The patients were divided into the two groups, nine for the experimental group and eight for the control group. The experimental group was assigned to conduct cognition training using smart device application games and traditional cognition training for fifteen minutes each, and the control group has conducted the traditional cognition training for 30 minutes. All arbitrations were conducted for 30 minutes a day, five times a week and for four weeks. To assess the cognitive function, Korean Mini-Mental State Examination (K-MMSE), Lowenstein Occupational Therapy Cognitive Assessment (LOTCA) and visual memory 1 and 2 of Motor-free Visual Perception Test-3 (MVPT-3) were measured before and after the intervention. In the comparison of the change between the two groups, the experimental groups showed a significant improvement in the visual memory of Motor-free Visual Perception Test-3 and remembrance section of the Korean Mini-Mental State Examination (p<.05). The result of this research has confirmed that the cognition training using the smart device application game can make the positive change to the visual memory of the traumatic brain injury patients more than the traditional cognition training.