• 제목/요약/키워드: Device stress

검색결과 813건 처리시간 0.033초

Thermal Stress Simulation of Mass Concrete Using Thermal Stress Device

  • 무하마드나시르;김진근
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계학술발표회 논문집(I)
    • /
    • pp.474-477
    • /
    • 2006
  • To predict thermal stress independent of uncertain material properties of early age concrete, such as elastic modulus and creep, thermal stress device is used. In order to verify the application of various degree of constraint in the thermal stress device, a series of experiments were performed on mass concrete followed by numerical simulation. The application of various degrees of constraint can be achieved by using constraint frame material with different thermal expansion coefficient, length, and cross sectional area. Temperature development in the real structure has been simulated using temperature and humidity control chamber. The results from experiments and numerical analysis show that the thermal stresses estimated from simulation agree well with the general stress variations in the real structure even though the properties of concrete are uncertain.

  • PDF

DC 및 AC 스트레스에서 Lateral DMOS 트랜지스터의 소자열화 (Hot-Carrier-Induced Degradation of Lateral DMOS Transistors under DC and AC Stress)

  • 이인경;윤세레나;유종근;박종태
    • 대한전자공학회논문지SD
    • /
    • 제44권2호
    • /
    • pp.13-18
    • /
    • 2007
  • 본 연구에서는 Lateral DMOS 소자열화 메카니즘이 게이트 산화층의 두께에 따라 다른 것을 측정을 통하여 알 수 있었다. 얇은 산화층 소자는 채널에 생성되는 계면상태와 drift 영역에 포획되는 홀에 의하여 소자가 열화 되고 두꺼운 산화층 소자에서는 채널 영역의 계면상태 생성에 의해서 소자가 열화 되는 것으로 알 수 있었다. 그리고 소자 시뮬레이션을 통하여 다른 열화 메카니즘을 입증할 수 있었다. DC 스트레스에서의 소자 열화와 AC 스트레스에서 소자열화의 비교로부터 AC스트레스에서 소자열화가 적게 되었으며 게이트 펄스의 주파수가 증가할수록 소자열화가 심함을 알 수 있었다. 그 결과로부터 RF LDMOS 에서는 소자열화가 소자설계 및 회로설계에 중요한 변수로 작용할 수 있음을 알 수 있었다.

Evaluation Method of Hairstyling Materials and its Application to Cosmetic Preparations

  • Abe, Hidetoshi;Iida, Ichiro;Someya, Takao
    • 대한화장품학회:학술대회논문집
    • /
    • 대한화장품학회 2003년도 IFSCC Conference Proceeding Book I
    • /
    • pp.1-12
    • /
    • 2003
  • Instead of sensory evaluation, we designed an evaluation method of the setting function of hairstyling products, based on an original theory focusing on changes in bending stress observed when a load with continuous bending is applied to human hair. Specifically, we developed a device to measure bending stress to quickly and objectively evaluate the condition of human hair, particularly its dynamic properties such as the setting function, following the application of hairstyling products. This device generates a load with continuous bending while applying a pendulum motion to a hair tress, one end of which is anchored. The setting function and holding power of resins of various molecular weight and ionic properties were evaluated using this device. The results demonstrated a close correlation with those obtained by experts' sensory evaluation. The evaluation results of bending stress and holding rate confirmed that the combined use of two different resins could improve the function of setting preparations. Evaluation using this device was able to substitute for sensory evaluation, and offers quick objective evaluation and detection of changes in the holding power of hairstyling products over time. We conclude that evaluation using this device is a promising new method.

  • PDF

Measuring rheological properties using a slotted plate device

  • Kee, Daniel-De;Kim, Young-Dae;Nguyen, Q. Dzuy
    • Korea-Australia Rheology Journal
    • /
    • 제19권2호
    • /
    • pp.75-80
    • /
    • 2007
  • The slotted plate technique has previously been shown to be a successful method for directly measuring the static yield stress of suspensions. In this study, we further establish the usefulness of the slotted plate device as a rheometer especially at low shear rates, taking advantage of the extremely low speeds of the slotted plate technique. Newtonian fluids, a shear thinning fluid, and yield stress fluids were tested using the slotted plate device and the results were compared with those from a commercial rheometer using different standard flow geometries. The relationship between the stress on the plate and the viscosity for the slotted plate device obtained by dimensional analysis (drag) predicts a linear relationship between the force at the plate and the plate speed, consistent with the experimental data. The slotted plate device can measure viscosities at very low shear rates. The apparent viscosity - shear-rate data obtained from the slotted plate device are complementary to those obtained using a commercial rheometer. That is : the slotted plate can measure viscosity in the shear rate range $10^{-7}<\dot{\gamma}<10^{-3}\;s^{-1}$, while the commercial rheometer measures viscosity at shear rates higher than $10^{-3}\;s^{-1}$.

Correlation between spin density and Vth instability of IGZO thin-film transistors

  • Park, Jee Ho;Lee, Sohyung;Lee, Hee Sung;Kim, Sung Ki;Park, Kwon-Shik;Yoon, Soo-Young
    • Current Applied Physics
    • /
    • 제18권11호
    • /
    • pp.1447-1450
    • /
    • 2018
  • The electron spin resonance (ESR) detects point defect of the In-Ga-Zn oxide (IGZO) like singly ionized oxygen vacancies and excess oxygen, and get spin density as a parameter of defect state. So, we demonstrated the spin density measurement of the IGZO film with various deposition conditions and it has linear relationship. Moreover, we matched the spin density with the total BTS and the threshold voltage ($V_{th}$) distribution of the IGZO thin film transistors. The total BTS ${\Delta}V_{th}$ and the $V_{th}$ distribution were degraded due to the spin density increases. The spin density is the useful indicator to predict $V_{th}$ instability of IGZO TFTs.

등방성체용 동적 광탄성 하이브리드 법 개발에 관한 연구 (A Study on the Development of the Dynamic Photoelastic Hybrid Method for Isotropic Material)

  • 신동철;황재석
    • 대한기계학회논문집A
    • /
    • 제24권9호
    • /
    • pp.2220-2227
    • /
    • 2000
  • In this paper, dynamic photoelastic hybrid method is developed and its validity is certified. The dynamic photoelastic hybrid method can be used on the obtaining of dynamic stress intensity factors and dynamic stress components. The effect of crack length on the dynamic stress intensity factors is less than those on the static stress intensity factors. When structures are under the dynamic mixed mode load, dynamic stress intensity factor of mode I is almost produced. Dynamic loading device manufactured in this research can be used on the research of dynamic behavior when mechanical resonance is produced and when crack is propagated with the constant velocity.

P-채널 다결정 실리콘 박막 트랜지스터의 Alternate Bias 스트레스 효과 (Effect of Alternate Bias Stress on p-channel poly-Si TFT`s)

  • 김영호;조봉희;강동헌;길상근;임석범;임동준
    • 한국전기전자재료학회논문지
    • /
    • 제14권11호
    • /
    • pp.869-873
    • /
    • 2001
  • The effects of alternate bias stress on p-channel poly-Si TFT\`s has been systematically investigated. We alternately applied positive and negative bias stress on p-channel poly-Si TFT\`s, device Performance(V$\_$th/, g$\_$m/, leakage current, S-slope) are alternately appeared to be increasing and decreasing. It has been shown that device performance degrade under the negative bias stress while improve under the positive bias stress. This effects have been related to the hot carrier injection into the gate oxide rather than the generation of defect states within the poly-Si/SiO$_2$ interface under alternate bias stress.

  • PDF

마이크로 머신(MEMS) 소자 패키지의 열응력에 대한 연구 (A Study on the Thermo-Mechanical Stress of MEMS Device Packages)

  • 전우석;백경욱
    • 한국재료학회지
    • /
    • 제8권8호
    • /
    • pp.744-750
    • /
    • 1998
  • 마이크로 머신 소자는 일반전자 소자와 달리 소자 자체에 미세한 기계적 구조물을 갖고 있으며, 이의 구동을 통하여 센서 또는 엑츄에이터의 기능을 갖게 된다. 이 소자들은 그 작동 요구특성에 따라 패키지의 기계적, 환경적 격리를 요구하거나 분위기조절이 요구되는 등 까다로운 패키지 특성을 필요로 한다. 또한 미세한 작동소자들로 인하여 열 및 열응력에 매우 민감하며, 패키지방법에 따라 구동부위의 작동 특성이 크게 변화할 수 있다. 본 연구에서는 마이크로 머신 소자가 패키지 상에 접촉되어 패키지 될 때, 소자의 접촉 재료 및 공정온도, 크기 등이 마이크로 머신 소자에 미치는 열응력을 연구하였다. 유한요소해석법을 사용하여 소자에 미치는 열응력과 이로 인한 마이크로머신 소자의 물리적 변형을 예측하고, 이를 통하여 마이크로 머신 소자 패키지에 최소한의 열응력을 미치는 소자접속 재료의 선별과 패키지 설계의 최적화를 이루고자 하였다.

  • PDF

척주 온열 마사지 기기를 이용한 근육통, 우울감 및 스트레스 개선 효과 (The Effectiveness of Using a Spinal Column Thermal Massage Device on Muscle Pain, Depression and Stress)

  • 이미현;김가은;장홍영;조일영
    • 한국융합학회논문지
    • /
    • 제11권7호
    • /
    • pp.361-368
    • /
    • 2020
  • 본 연구는 근육통 환자들의 척주온열마사지 기기 사용이 근육통 개선에 효과가 있는지를 살펴보고, 정서적 부분인 우울감, 스트레스 개선에도 효과가 있는지 검증하는데 목적이 있다. 이를 위해 연구참여자 16명(남자, 31.25%)은 온열 마사지 기기에 대한 처치로 4주간 주 5회, 1회당 40분을 실시하였다. 연구결과, 주관적 통증정도는 VAS -46.32%, PDI -44.86%의 변화율을 보였으며, VAS, PDI 모두 유의한 감소를 보였다. 기타 우울감 및 스트레스 정도에서는 BDI -21.84%, SRI -11.48%의 변화율을 보였으며, BDI, SRI 모두 유의한 감소를 나타내었다. 따라서 근육통 환자 치료 시 온열마사지 기기를 활용한다면 주관적 근육통, 우울감 및 스트레스 개선에서 긍정적인 효과가 있을 것으로 기대된다.

막구조물의 막장력 측정장치 개발에 관한 연구 (DEVEOPMENT OF MEASURING SYSTEM OF MEMBRANE STRESS FOR MEMBRANE STRUCTURE)

  • 정한목;우재원;조병욱;이성연
    • 한국공간구조학회:학술대회논문집
    • /
    • 한국공간구조학회 2008년도 춘계 학술발표회 논문집
    • /
    • pp.171-178
    • /
    • 2008
  • This paper is concerned with the development of a measurement system using field measuring device which will give the membrane stress of the membrane structures. Up to this point, several techniques on measurement of membrane stresses has been proposed and some have been used in the fields, but accuracy of the measured stresses to be far from reliable one. Such situation has not been changed until recent days, we do not have the measurement device on which we can depend. On top of that, due to the different properties in cross directions for material of the membrane, the stress in the warp direction is different from that in the fill one. A new method is proposed to measured membrane stresses in two different direction separately, where instead of membrane stresses directly, an external force perpendicular to the membrane to be applied. A portable device can measure the applied force and the displacement. A special testing bed to be fabricated to accommodate $50cm{\times}50$ manbrane specimen which can apply 5 ton load in two orthogonal direction. A special device using push-pull gage was developed. To measure the membrane stresses in warp and fill direction separately, a different length of the tips are used. The measuring device which can called tension meter, can be calibrated on the testing bed, and optimized the length and shape of tip.

  • PDF