• Title/Summary/Keyword: Deviation

Search Result 9,477, Processing Time 0.038 seconds

Dosimetric Evaluation of a Small Intraoral X-ray Tube for Dental Imaging (치과용 초소형 X-선 튜브의 선량평가)

  • Ji, Yunseo;Kim, YeonWoo;Lee, Rena
    • Progress in Medical Physics
    • /
    • v.26 no.3
    • /
    • pp.160-167
    • /
    • 2015
  • Radiation exposure from medical diagnostic imaging procedures to patients is one of the most significant interests in diagnostic x-ray system. A miniature x-ray intraoral tube was developed for the first time in the world which can be inserted into the mouth for imaging. Dose evaluation should be carried out in order to utilize such an imaging device for clinical use. In this study, dose evaluation of the new x-ray unit was performed by 1) using a custom made in vivo Pig phantom, 2) determining exposure condition for the clinical use, and 3) measuring patient dose of the new system. On the basis of DRLs (Diagnostic Reference Level) recommended by KDFA (Korea Food & Drug Administration), the ESD (Entrance Skin Dose) and DAP (Dose Area Product) measurements for the new x-ray imaging device were designed and measured. The maximum voltage and current of the x-ray tubes used in this study were 55 kVp, and 300 mA. The active area of the detector was $72{\times}72mm$ with pixel size of $48{\mu}m$. To obtain the operating condition of the new system, pig jaw phantom images showing major tooth-associated tissues, such as clown, pulp cavity were acquired at 1 frame/sec. Changing the beam currents 20 to $80{\mu}A$, x-ray images of 50 frames were obtained for one beam current with optimum x-ray exposure setting. Pig jaw phantom images were acquired from two commercial x-ray imaging units and compared to the new x-ray device: CS 2100, Carestream Dental LLC and EXARO, HIOSSEN, Inc. Their exposure conditions were 60 kV, 7 mA, and 60 kV, 2 mA, respectively. Comparing the new x-ray device and conventional x-ray imaging units, images of the new x-ray device around teeth and their neighboring tissues turn out to be better in spite of its small x-ray field size. ESD of the new x-ray device was measured 1.369 mGy on the beam condition for the best image quality, 0.051 mAs, which is much less than DRLs recommended by IAEA (International Atomic Energy Agency) and KDFA, both. Its dose distribution in the x-ray field size was observed to be uniform with standard deviation of 5~10 %. DAP of the new x-ray device was $82.4mGy*cm^2$ less than DRL established by KDFA even though its x-ray field size was small. This study shows that the new x-ray imaging device offers better in image quality and lower radiation dose compared to the conventional intraoral units. In additions, methods and know-how for studies in x-ray features could be accumulated from this work.

Dosimetric Effect on Selectable Optimization Parameters of Volumatric Modulated Arc Therapy (선택적 최적화 변수(Selectable Optimization Parameters)에 따른 부피적조절회전방사선치료(VMAT)의 선량학적 영향)

  • Jung, Jae-Yong;Shin, Yong-Joo;Sohn, Seung-Chang;Kim, Yeon-Rae;Min, Jung-Wan;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.23 no.1
    • /
    • pp.15-25
    • /
    • 2012
  • The aim of this study is to evaluate plan quality and dose accuracy for Volumetric Modulated Arc Therapy (VMAT) on the TG-119 and is to investigate the effects on variation of the selectable optimization parameters of VMAT. VMAT treatment planning was implemented on a Varian iX linear accelerator with ARIA record and verify system (Varian Mecical System Palo Alto, CA) and Oncentra MasterPlan treatment planning system (Nucletron BV, Veenendaal, Netherlands). Plan quality and dosimetric accuracy were evaluated by effect of varying a number of arc, gantry spacing and delivery time for the test geometries provided in TG-119. Plan quality for the target and OAR was evaluated by the mean value and the standard deviation of the Dose Volume Histograms (DVHs). The ionization chamber and $Delta^{4PT}$ bi-planar diode array were used for the dose evaluation. For treatment planning evaluation, all structure sets closed to the goals in the case of single arc, except for the C-shape (hard), and all structure sets achieved the goals in the case of dual arc, except for C-shape (hard). For the variation of a number of arc, the simple structure such as a prostate did not have the difference between single arc and dual arc, whereas the complex structure such as a head and neck showed a superior result in the case of dual arc. The dose distribution with gantry spacing of $4^{\circ}$ was shown better plan quality than the gantry spacing of $6^{\circ}$, but was similar results compared with gantry spacing of $2^{\circ}$. For the verification of dose accuracy with single arc and dual arc, the mean value of a relative error between measured and calculated value were within 3% and 4% for point dose and confidence limit values, respectively. For the verification on dose accuracy with the gantry intervals of $2^{\circ}$, $4^{\circ}$ and $6^{\circ}$, the mean values of relative error were within 3% and 5% for point dose and confidence limit values, respectively. In the verification of dose distribution with $Delta^{4PT}$ bi-planar diode array, gamma passing rate was $98.72{\pm}1.52%$ and $98.3{\pm}1.5%$ for single arc and dual arc, respectively. The confidence limit values were within 4%. The smaller the gantry spacing, the more accuracy results were shown. In this study, we performed the VMAT QA based on TG-119 procedure, and demonstrated that all structure sets were satisfied with acceptance criteria. And also, the results for the selective optimization variables informed the importance of selection for the suitable variables according to the clinical cases.

A Hematological Study on Korean of Rural Community - Correllation on Blood Pressure, Hematocrit- (한국(韓國) 일부(一部) 농촌주민(農村住民)에 대(對)한 혈액학적(血液學的) 고찰(考察) -혈압치(血壓値)와 적혈구용적치관계(赤血球容積値關係)를 중심(中心)으로-)

  • Nam, Taik-Sung;Kang, Duk-Yong
    • Journal of agricultural medicine and community health
    • /
    • v.2 no.1
    • /
    • pp.36-42
    • /
    • 1977
  • A study on blood pressure and hematocrit values of 1,559 people in 19 Korean rural areas was carried out in 1974 and the results were analyzed statistically. Obtained as follows: 1. The blood pressure according to sex and age groups (from the twenties to the seventies) was as follows: 1) The blood pressure of male by age group il) In the twenties, M (mean) was 125. 85/74, 15mm/Hg, a (standard deviation) was 15.9/10.2, and ill (standard error) was 1.55/0.99. (2) In the thirties, ${\delta}$ was 123.93/77.19 mm/Hg, a was 14.4/10.8, and m was 1.24/0.93. (3) In the forties, M was 128.44/81.15 mm/Hg, a was 23.9/14.7, and m was 2.16/1.33. (4) In the fifties, M was 128.48/181.24 mm/Hg, a was 24.7/13.9, and m was 2.05/1.16. (5) In the sixties, M was 135.80/81.70 mm/Hg, a was 27.4/18.8, and ${\delta}$ was 2.74/1.88. (6) In the seventies, M was 146.84/83. 16mm/Hg, ${\delta}$ was 24.5/10.0, and m was 5.62/2.30. 2) The blood pressure of female by age group (1) In the twenties, M was 117.89/73.33 mm/Hg, ${\delta}$ was 15.7/12.1, and m was 1.42/1.09. (2) In the thirties, M was 118.04/75.71 mm/Hg, ${\delta}$ was 16.9/13.0, and m was 1.13/0.87. (3) In the forties, M was 120.92/78.17 mm/Hg, ${\delta}$ was 20.9/12.9, and m was 1.42/0.87. (4) In the fifties, M was 122.14/79.55 mm/Hg, ${\delta}$ was 24.2/15.9, and m was 1.63/1.07. (5) In the sixties, M was 131.57/84.29 mm/Hg, ${\delta}$ was 28.4/16.9, and m was 2.58/1.53. (6) In the seven ties, M was 139.62/86, 54 mm/Hg, ${\delta}$ was 22.4/15.7, and m was 4.38/3.09. And the range of systolic blood pressure in male was 70~230 mm/Hg and in female was 80-230 mm/Hg. The range of distolic blood pressure in male was 50~160 mm/Hg and in female was 40~140 mm/Hg. 2. The hematocrit value according to sex and age groups was as follows: 1) The hematocrit values of male by age group (1) In the twenties, M was 42.72%, ${\delta}$ was 3.05, and m was 0.30. (2) In the thirties, M was 41.77%, ${\delta}$ was 3.29, and m was 0.28. (3) In the forties, M was 41.39, ${\delta}$ was 3.86, and m was 0.35. (4) In the fifties, M was 40.12%, ${\delta}$ was 3.65, and m was 0.30. (5) In the sixties, M was 39.88%, ${\delta}$ was 3.81. and m was 0.38. (6) In the seventies, M was 38.47%, ${\delta}$ was 2.27, and m was 0.52. 2) The hematocrit values of female by age group (1) In the twenties, M was 35.40%, ${\delta}$ was 3.37, and m was 0.30. (2) In the thirties, M was 35.50%, ${\delta}$ was 3. 35, and m was 0.22. (3) In the forties, M was 35.75%, ${\delta}$ was 3. 18, and m was 0.22. (4) In the fifties, M was 35.84%, ${\delta}$ was 3.30, and m was 0.22. (5) In the sixties, M was 35.70%, ${\delta}$ was 3.35, and m was 0.30. (6) In the seventies, M was 35.08%, ${\delta}$ was 3.08, and m was 0.60. The range of hematocrit values in male was 23~50% and in female was 18~50% (un associated with age groups). 3. In comparison with the blood pressure and the value of hematocrit of study groups showed that the blood pressure raised higher but the value of hematocrit got lowered on the contrary as the groups are getting older. 4. Total number of patients with hypertension was 165(10.6%) which were consisted with 71 male (11.3%) and 94 female (10.1%). But only two cases of the male patient and one case of the female patient were associated with protein uria. 5. The incidence of anemia by hematocrit values was as follows: 1) The incidence of male anemia patients based on$\leqq$41% ($\leqq$39%). (1) In the twenties, incidence was 43.90% (16.98%). (2) In the thirties, 41.48% (25.93%). (3) In the forties, 42.62% (25.41%). (4) In the fifties, 62.76% (40.69%). (5) In the sixties, 70% (38%). (6) In the seventies, 84.21% (73.68%). 2) The incidence of female anemia patients bailed on $\leqq$35% ($\leqq$34%). (1) In the twenties, incidence was 43.90% (37.39%). (2) In the thirties, 48.21 % (33.93%). (3) In the forties, 43.58% (32.57%). (4) In the fifties, 45.91 % (34.09%). (5) In the sixties, 47.11% (37.19%). (6) In the seventies, 50% (46.15%) 6. The incidence rate of anemia patients with hypertension was highest in the age group 51~60 in male and 31~40 in female.

  • PDF

The study of MDCT of Radiation dose in the department of Radiology of general hospitals in the local area (일 지역 종합병원 영상의학과 MDCT선량에 대한 연구)

  • Shin, Jung-Sub
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.4
    • /
    • pp.281-290
    • /
    • 2012
  • The difference of radiation dose of MDCT due to different protocols between hospitals was analyzed by CTDI, DLP, the number of Slice and the number of DLP/Slice in 30 cases of the head, the abdomen and the chest that have 10 cases each from MDCT examination of the department of diagnostic imaging of three general hospitals in Gyeongsangbuk-do. The difference of image quality, CTDI, DLP, radiation dose in the eye and radiation dose in thyroid was analyzed after both helical scan and normal scan for head CT were performed because a protocol of head CT is relatively simple and head CT is the most frequent case. Head CT was significantly higher in two-thirds of hospitals compared to A hospital that does not exceed a CTDI diagnostic reference level (IAEA 50mGy, Korea 60mGy) (p<0.001). DLP was higher in one-third of hospitals than a diagnostic reference level of IAEA 1,050mGy.cm and Korea 1,000mGy.cm and two-thirds exceeded the recommendation of Korea and those were significantly higher than A hospital that does not exceed a diagnostic reference level (p<0.001). Abdomen CT showed 119mGy that was higher than a diagnostic reference level of IAEA 25mGy and Korea 20mGy in one-third. DLP in all hospitals was higher that Korea recommendation of 700mGy.cm. Among target hospitals, C hospital showed high radiation dose in all tests because MPR and 3D were of great importance due to low pitch and high Tube Curren. To analyze the difference of radiation dose by scan methods, normal scan and helical scan for head CT of the same patient were performed. In the result, CTDI and DLP of helical CT were higher 63.4% and 93.7% than normal scan (p<0.05, p<0.01). However, normal scan of radiation dose in thyroid was higher 87.26% (p<0.01). Beam of helical CT looked like a bell in the deep part and the marginal part so thyroid was exposed with low radiation dose deviated from central beam. In addition, helical scan used Gantry angle perpendicularly and normal scan used it parallel to the orbitomeatal line. Therefore, radiation dose in thyroid decreased in helical scan. However, a protocol in this study showed higher radiation dose than diagnostic reference level of KFDA. To obey the recommendation of KFDA, low Tube Curren and high pitch were demanded. In this study, the difference of image quality between normal scan and helical scan was not significant. Therefore, a standardized protocol of normal scan was generally used and protective gear for thyroid was needed except a special case. We studied a part of CT cases in the local area. Therefore, the result could not represent the entire cases. However, we confirmed that patient's radiation dose in some cases exceeded the recommendation and the deviation between hospitals was observed. To improve this issue, doctors of diagnostic imaging or technologists of radiology should perform CT by the optimized protocol to decrease a level of CT radiation and also reveal radiation dose for the right to know of patients. However, they had little understanding of the situation. Therefore, the effort of relevant agencies with education program for CT radiation dose, release of radiation dose from CT examination and addition of radiation dose control and open CT contents into evaluation for hospital services and certification, and also the effort of health professionals with the best protocol to realize optimized CT examination.

The Precision Test Based on States of Bone Mineral Density (골밀도 상태에 따른 검사자의 재현성 평가)

  • Yoo, Jae-Sook;Kim, Eun-Hye;Kim, Ho-Seong;Shin, Sang-Ki;Cho, Si-Man
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.67-72
    • /
    • 2009
  • Purpose: ISCD (International Society for Clinical Densitometry) requests that users perform mandatory Precision test to raise their quality even though there is no recommendation about patient selection for the test. Thus, we investigated the effect on precision test by measuring reproducibility of 3 bone density groups (normal, osteopenia, osteoporosis). Materials and Methods: 4 users performed precision test with 420 patients (age: $57.8{\pm}9.02$) for BMD in Asan Medical Center (JAN-2008 ~ JUN-2008). In first group (A), 4 users selected 30 patient respectively regardless of bone density condition and measured 2 part (L-spine, femur) in twice. In second group (B), 4 users measured bone density of 10 patients respectively in the same manner of first group (A) users but dividing patient into 3 stages (normal, osteopenia, osteoporosis). In third group (C), 2 users measured 30 patients respectively in the same manner of first group (A) users considering bone density condition. We used GE Lunar Prodigy Advance (Encore. V11.4) and analyzed the result by comparing %CV to LSC using precision tool from ISCD. Check back was done using SPSS. Results: In group A, the %CV calculated by 4 users (a, b, c, d) were 1.16, 1.01, 1.19, 0.65 g/$cm^2$ in L-spine and 0.69, 0.58, 0.97, 0.47 g/$cm^2$ in femur. In group B, the %CV calculated by 4 users (a, b, c, d) were 1.01, 1.19, 0.83, 1.37 g/$cm^2$ in L-spine and 1.03, 0.54, 0.69, 0.58 g/$cm^2$ in femur. When comparing results (group A, B), we found no considerable differences. In group C, the user_1's %CV of normal, osteopenia and osteoporosis were 1.26, 0.94, 0.94 g/$cm^2$ in L-spine and 0.94, 0.79, 1.01 g/$cm^2$ in femur. And the user_2's %CV were 0.97, 0.83, 0.72 g/$cm^2$ L-spine and 0.65, 0.65, 1.05 g/$cm^2$ in femur. When analyzing the result, we figured out that the difference of reproducibility was almost not found but the differences of two users' several result values have effect on total reproducibility. Conclusions: Precision test is a important factor of bone density follow up. When Machine and user's reproducibility is getting better, it’s useful in clinics because of low range of deviation. Users have to check machine's reproducibility before the test and keep the same mind doing BMD test for patient. In precision test, the difference of measured value is usually found for ROI change caused by patient position. In case of osteoporosis patient, there is difficult to make initial ROI accurately more than normal and osteopenia patient due to lack of bone recognition even though ROI is made automatically by computer software. However, initial ROI is very important and users have to make coherent ROI because we use ROI Copy function in a follow up. In this study, we performed precision test considering bone density condition and found LSC value was stayed within 3%. There was no considerable difference. Thus, patient selection could be done regardless of bone density condition.

  • PDF

Mumps- and Rubella-specific IgG Levels in Adolescents (청소년기의 연령증가에 따른 볼거리 및 풍진 항체가 변동)

  • Cheon, Hae Won;Shin, Young Kyoo;Lee, Kang Woo;Choung, Ji Tae;Tockgo, Young Chang
    • Pediatric Infection and Vaccine
    • /
    • v.5 no.1
    • /
    • pp.128-135
    • /
    • 1998
  • Purpose : This study was intended to measure seropositivities and the level of mumps- and rubella-specific IgG of MMR vaccinees from 12 to 17 years of age in Korea. Materials and Methods : From May 1996 to July 1996 we obtained sera from students of 1 middle and 2 high schools in Seoul, who were MMR vaccinees from 12 to 17 years of age and had no evidence of immunodeficiency. These 216 study population include 110 males and 106 females. Mumps- and rubella-specific IgG antibody levels were measured by ELISA. Cut-off values for seropositivity were 20 U(Gamma Unit) in mumps and over 0.17 in rubella. Results : 1) As age increased, seropositivities to mumps increased, being 68.4% in 12 year, 79.3% in 13 year, 72.2% in 14 year, 82.0% in 15 year, 87.5% in 16 year, 87.0% in 17 year, which however has no statistical significance. 2) As age increased, the level of mumps-specific IgG antibody(mean+standard deviation, GU) increased, being $52.0{\pm}49.2$ in 12 year, $65.9{\pm}51.4$ in 13 year, $71.1{\pm}66.0$ in 14 year, $67.8{\pm}53.6$ in 15 year, $82.8{\pm}67.8$ in 16 year, $92.0{\pm}68.9$ in 17 year, which however has no statistical significance. 3) As age increased, seropositivities of rubella-specific IgG increased significantly, being 26.3% in 12 year, 20.7% in 13 year, 50.0% in 14 year, 67.2% in 15 year, 66.7% in 16 year, 65.2% in 17 year(P<0.001). 4) As age increased, rubella-specific IgG increased significantly, being $0.13{\pm}0.145$ in 12 year, $0.087{\pm}0.101$ in 13 year, $0.194{\pm}0.168$ in 14 year, $0.260{\pm}0.187$ in 15 year, $0.305{\pm}0.213$ in 16 year, $0.325{\pm}0.221$ in 17 year(P<0.001). There was positive correlation between age and rubella-specific IgG titer(rubella-specific $IgG=0.0517{\times}age-0.5586$, r=0.3752, P<0.001). Conclusion : In adolescent, seropositivities and the level of mumps-specific IgG remained relatively high, but approximately 20% of study population showed seronegativity. Seropositivities and the level of rubella-specific IgG showed the lowest level at 13 years of age and were increased with age after 14 years of age. Further evaluation may be needed to elucidate the cause of these changes of rubella-specific IgG.

  • PDF

Development of Adjustable Head holder Couch in H&N Cancer Radiation Therapy (두경부암 방사선 치료 시 Set-Up 조정 Head Holder 장치의 개발)

  • Shim, JaeGoo;Song, KiWon;Kim, JinMan;Park, MyoungHwan
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.43-50
    • /
    • 2014
  • In case of all patients who receive radiation therapy, a treatment plan is established and all steps of treatment are planned in the same geometrical condition. In case of head and neck cancer patients who undergo simulated treatment through computed tomography (CT), patients are fixed onto a table for planning, but laid on the top of the treatment table in the radiation therapy room. This study excogitated and fabricated an adjustable holder for head and neck cancer patients to fix patient's position and geometrical discrepancies when performing radiation therapy on head and neck cancer patients, and compared the error before and after adjusting the position of patients due to difference in weight to evaluate the correlation between patients' weight and range of error. Computed tomography system(High Advantage, GE, USA) is used for phantom to maintain the supine position to acquire the images of the therapy site for IMRT. IMRT 4MV X-rays was used by applying the LINAC(21EX, Varian, U.S.A). Treatment planning system (Pinnacle, ver. 9.1h, Philips, Madison, USA) was used. The setup accuracy was compared with each measurement was repeated five times for each weight (0, 15, and 30Kg) and CBCT was performed 30 times to find the mean and standard deviation of errors before and after the adjustment of each weight. SPSS ver.19.0(SPSS Inc., Chicago, IL,USA) statistics program was used to perform the Wilcoxon Rank test for significance evaluation and the Spearman analysis was used as the tool to analyze the significance evaluation of the correlation of weight. As a result of measuring the error values from CBCT before and after adjusting the position due to the weight difference, X,Y,Z axis was $0.4{\pm}0.8mm$, $0.8{\pm}0.4mm$, 0 for 0Kg before the adjustment. In 15Kg CBCT before and after adjusting the position due to the weight difference, X,Y,Z axis was $0.2{\pm}0.8mm$, $1.2{\pm}0.4mm$, $2.0{\pm}0.4mm$. After adjusting position was X,Y,Z axis was $0.2{\pm}0.4mm$, $0.4{\pm}0.5mm$, $0.4{\pm}0.5mm$. In 30Kg CBCT before and after adjusting the position due to the weight difference, X,Y,Z axis was $0.8{\pm}0.4mm$, $2.4{\pm}0.5mm$, $4.4{\pm}0.8mm$. After adjusting position was X,Y,Z axis was $0.6{\pm}0.5mm$, $1.0{\pm}0mm$, $0.6{\pm}0.5mm$. When the holder for the head and neck cancer was used to adjust the ab.0ove error value, the error values from CBCT were $0.2{\pm}0.8mm$ for the X axis, $0.40{\pm}0.54mm$ for Y axis, and 0 for Z axis. As a result of statistically analyzing each value before and after the adjustment the value was significant with p<0.034 at the Z axis with 15Kg of weight and with p<0.038 and p<0.041 at the Y and Z axes respectively with 30Kg of weight. There was a significant difference with p<0.008 when the analysis was performed through Kruscal-Wallis in terms of the difference in the adjusted values of the three weight groups. As it could reduce the errors, patients' reproduction could be improved for more precise and accurate radiation therapy. Development of an adjustable device for head and neck cancer patients is significant because it improves the reproduction of existing equipment by reducing the errors in patients' position.

Effect of xylazine hydrochloride on histamine release (Xylazine이 histamine 유리에 미치는 영향)

  • 김영환;박준형
    • Korean Journal of Veterinary Service
    • /
    • v.25 no.1
    • /
    • pp.53-73
    • /
    • 2002
  • It has been reported that degranulation of mast cells in rats, rabbits and dog was observed after dosing xylazine hydrochloride(Xh) which has been widely used as sedative, analgesic and muscular relaxant. Therefore, this experiment was conducted to examine the relations between Xh and histamine release and to identify the action of ${\alpha}$-adrenoceptors which exists on the suface of mast cells. 1. The content of histamine within serum was measured with HPLC by performing the O-phthalaldehyde(OPA) fluorescent derivation. The pretreatment method had a little modification from the conventional method. The pretreament was carried out in the following method. 0.2$m\ell$ of serum and 1$m\ell$ of butanol were added to mixed together and then the liquid was centrifugally separated at 4$^{\circ}C$ and 2,000 rpm for 3 minutes. 0.4$m\ell$ of 0.1N HCl and 1.6$m\ell$ of heptane were added to 0.8$m\ell$ of supernatant taken from the liquid, and they were mixed together. This mixture was also centrifugally separated at 4$^{\circ}C$ and 2,000 rpm for 5 minutes. The supernatant was thrown away and the OPA fluorescent derivation was carried out with 0.2$m\ell$ of the lower liquid then, 5 minutes after mixing 400${\mu}\ell$ of 0.1N HCl, 120${\mu}\ell$ of 1N NaOH and 40${\mu}\ell$ of 0.1% OPA in the 0.2$m\ell$ of the lower liquid,120${\mu}\ell$ of 3.57N H$_3$PO$_4$ was added to the mixed liquid, and the liquid, was mixed again and syringe-filtered. Then, the measurement was done with HPLC in the 30 : 70(ν/ν) ratio of 0.004M KH$_2$PO$_4$: CH$_3$CN, flow rate of 1.0$m\ell$/min., and a wavelength of λex= 350nm and λem=444nm at the column temperature of 27$^{\circ}C$, using the fluorescence detector. 2. The content of histamine in each laboratory animal appeared to be higher in such an order as rabbit, rat, guinea pig, dog, Korean indigenous goat, swine, Korean indigenous cattle, Holstein, and mouse, of which the individual mean values${\pm}$standard deviation were 2.0668 ${\pm}$ 0.6049. 0.4999 ${\pm}$ 0.2278, 0.4241 ${\pm}$ 0.1974, 0.1054 ${\pm}$ 0.0556, 0.1028 ${\pm}$ 0.0276, 0.0972 ${\pm}$ 0.0513, 0.0872 ${\pm}$ 0.0373, 0.0717 ${\pm}$ 0.0379, and 0.0706 ${\pm}$ 0.0366, respectively. 3. The content of histamine was measured at the moments of 15-, 30-, 60-, 120-minutes after inoamuscular injection of 20mg/100kg Xh into two to 4 years old Holstein weighing 600∼700kg. The result showed that there was a significant increase at the times of 30- and 90-minutes after injection(p<0.05). 4. Intramuscular injection of 3mg/10kg Xh was given to crossbred pug dogs weighing 2.5∼4.3kg. The content of histamine was measured at the times of 30-, 60-, 90- and 120-minutes after injection. The result revealed that there was a significant increase at the times of 60-and 90-minutes after injection(p<0.05). 5. Intramuscular injection of 10mg/$m\ell$∼25mg/$m\ell$ Xh in concentration of 0.1$m\ell$ was applied to Korean indigenous goat over 5 months old. Then, the content of histamine was measured at the times of 15-, 30-, 60- and 90-minutes after injection. A significant increase was shown at the times of 30- and 60-minutes after injection(p<0.05). 6. The content of histamine was measured at the moments of 30- and 60-minutes after intramuscular injection of 0.1-0.2$m\ell$ Xh (20mg/$m\ell$) into male rabbits weighting 2.5-4kg. A significant increase was found at the moment of 60 minutes after injection(p<0.001). 7. After administering Xh to the mast cell taken from the abdominal cavity of mouse, the content of histamine was measured. The result showed that the higher the concentration, the more significantly the content of histamine was increased(p<0.05). 8. Compound 48/80 was administered in concentration of 5$\mu\textrm{g}$/$m\ell$ and 10$\mu\textrm{g}$/$m\ell$ to the mast cell picked from the abdominal cavity of mouse. The result showed that there was a significant increase in the content of histamine in case of the concentration of 10$\mu\textrm{g}$/$m\ell$(p<0.05). It was found to be about 10,000 to 500,000 times stronger than the Xh. 9. After premedication of 1mg/kg of yohimbine hydrochloride as ${\alpha}$$_2$-adrenergic antagonist to rabbits, the Xh was administered to them. The result was that the value of histamine within serum was decreased significantly(p<0.001). 10. After premeditation of 1mg/kg of prazosin hydrochloride as ${\alpha}$$_1$-adrenergic antagonist to rabbits, the Xh was administered to them. It was found that the value of histamine within serum was decreased significantly(p<0.005). 11, Prazosin hydrochloride and yohimbine hydrochloride as ${\alpha}$$_1$-adrenergic antagonist, respectively, and ${\alpha}$$_2$-adrenergic antagonist were administerd. In this case, the value of histamine within serum was decreased significantly(p<0.0001). As the results, when the Xh is administered to various kinds of animals, the amount of histamine release within serum is increased. In view of the results so far achieved, it is concluded that Xh acted on both a$_1$-adrenoreceptor and ${\alpha}$$_2$-adrenoreceptor induces the degranulation of mast cell.

The Evaluation of IL-8 in the Serum of Pneumoconiotic patients (진폐증 환자에서의 혈청내 IL-8 농도)

  • Ahn, Hyeong Sook;Kim, Ji Hong;Chang, Hwang Sin;Kim, Kyung Ah;Lim, Young
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.6
    • /
    • pp.945-953
    • /
    • 1996
  • Background : Many acute and chronic lung diseases including pneumoconiosis are characterized by the presence of increased numbers of activated macrophages. These macrophages generate several inflammatory cell chemoattractants, by which neutrophil migrate from vascular compartment to the alveolar space. Recruited neutrophils secrete toxic oxygen radicals or proteolytic enzymes and induce inflammatory response. Continuing inflammatory response results in alteration of the pulmonary structure and irreversible fibrosis. Recently, a polypeptide with specific neutrophil chemotactic activity, interleukin-8(IL-8), has been cloned and isolated from a number of cells including : monocytes, macrophages and fibroblasts. IL-1 and/or TNF-${\alpha}$ preceded for the synthesis of IL-8, and we already observed high level of IL-1 and TNF-${\alpha}$ in the pneumoconioses. So we hypothesized that IL-8 may be a central role in the pathogenesis of pneumoconiosis. In order to evaluate the clinical utility of IL-8 as a biomarker in the early diagnosis of pneumoconiosis, we investigated the increase of IL-8 in the pneumoconiotic patient and the correlation between IL-8 level and progression of pneumoconiosis. Method : We measured IL-8 in the serum of 48 patients with pneumoconiosis and 16 persons without dust exposure history as a control group. Pneumoconiotic cases were divided into 3 groups according to ILO Classification : suspicious group(n=16), small opacity group(n=16) and large opacity group(n=16). IL-8 was measured by a sandwich enzytne immunoassay technique. All data were expressed as the $mean{\pm}standard$ deviation. Results: 1) The mean value of age was higher in the small opacity and large opacity group than comparison group, but smoking history was even. Duration of dust exposure was not different among 3 pneumoconiosis groups. 2) IL-8 level was $70.50{\pm}53.63pg/m{\ell}$ in the suspicious group, $107.50{\pm}45.88pg/m{\ell}$ in the small opacity group, $132.50{\pm}73.47pg/m{\ell}$ in the large opacity group and $17.85{\pm}33.85pg/m{\ell}$ in the comparison group. IL-8 concentration in all pneumoconiosis group was significant higher than that in the comparison group(p<0.001). 3) IL-8 level tended to increase with the progression of pneumoconiosis. Multiple comparison test using Anova/Scheffe analysis showed a significant difference between suspicious group and large opacity group(p<0.05). 4) The level of IL-8 was correlated with the progression of pneumoconiosis(r=0.4199, p<0.05). Conclusion : IL-8 is thought to be a good biomarker for the early diagnosis of pneumoconiosis.

  • PDF

A Study of the Health Service Computerization State and the Occupational Nurses's Satisfaction Level on Computerization (산업간호현장의 보건업무 전산화시스템 활용현황과 산업간호사의 전산화 직무만족도 연구)

  • Jung, Hee Young;Park, Hyoung-Sook
    • Korean Journal of Occupational Health Nursing
    • /
    • v.13 no.1
    • /
    • pp.5-18
    • /
    • 2004
  • This study aims to investigate the use state of the health service computerization system in the occupational nursing field and the occupational nursers' satisfaction level, and provide basic data to promote the development of the health service computerization system for the nursing field. For this study, a questionnaire was provided to 118 occupational nurses who belong to Busan and Gyeongnam branches of KAOHN(Korean Association of Occupational Health Nurses) for 2 months (from Dec. 1, 2002 to Jan. 31, 2003). A tool of Choi Yong-Heui(2000) was used to investigate the satisfaction level of using the health service computerization system. The collected materials were analyzed in real number and percentage, average and standard deviation, t-test and ANOVA by using the SPSS WIN 10.0 program. This study is summarized as follows: 1. The average age was $31.99{\pm}5.58$ old in this study. The married were 54.2%. Participants who graduated from a junior college was 76.9%. The average service period was $4.48{\pm}4.68$ years. In service types, 79.7% of participants served in a health care center. The average service period was $3.22{\pm}2.89$ years. The service place which had 1000 workers or more was 35.6%. 2. Only 20.3% of participants in this study had a computer use education. 3. The field who participants used mostly was communication/internet, $3.29{\pm}.85$ hours in average. 4. 97.1% of occupational fields had computers and peripheral devices: 71.4% in pentium computer, 42.8% in the hard disk capacity of 20-29GB, 60.0% in 15 inch monitors, 86.2% in printers, 18.1% in digital cameras, 12.4% in LAN, and 9.5% in scanners. 80.1% of the occupational fields which were objects of study could use communication. 5. The occupational fields which did not introduced the health service computerization system were 62.8%. The main cause was attributable to entrepreneurs' insufficient recognition 66.6%. 51.5% of the entrepreneurs did not have an introduction plan. 37.2% of participating companies had the health service computerization system. 56.4% of them introduced it since the year 2000. 81.6% of the introduction motivation aimed to the efficiency of health service. The most issue upon introduction was insufficient understanding of a person in charge - 25.6%. The in-house development of the system covered 56.4%. 61.5% of the participants accepted their demands from the first stage of development. The direct effect of computerization showed the increase of 25.9% in the quickness and continuity of service treatment, and 25.9% in the serviceability of statistical treatment. 6. 22.0% of the participants had a computerization system use education. 69.2% of them had a in-house education. An educational method by nurses who used the computerization system was 76.9%. 92.3% of the education was helpful for practical duties. 7. An analysis of the computer use by health service fields showed that the medicine management in a health management field was 15.9%. the work environment measuring management in a work environment filed was 32.9%. the employment. general and special examination management in a heal th management field was 61.1 %. the various reports management in an administrative field was 64%. the health education data preparation management in an educational field was 58.0%. and the medicine and expendables management in an equipment management field was 51.6%. An analysis of the computerization system use showed that the various statistical data manage in a health management field was 13.0%. the work environment measuring management in a health management field was 34.8%. the personal disease management in a health management field was 51.9%. the heal education data preparation management in an educational field was 54.5%. and the equipment management of health care centers in an equipment management field was 52.6%. 8. 31.6% of the participants wanted that health service computerization system would include the generals of health services. 42.4% of the participants thought that first of all. the aggressive interest and investment of employers were required to build the health service computerization system. 9. The participants' satisfaction level on the computerization system use was $3.51{\pm}.57$ points. An analysis by each factor showed $3.62{\pm}.68$ points in a service change factor. $3.15{\pm}.63$ points in a computer program use factor, and $3.45{\pm}.71$ points in a continuous computerization use factor. 10. An analysis of the computerization system use by general characteristics of participants showed that the married (p = .022) had the satisfaction level higher than the unmarried. 11. The satisfaction level of the computerization system use by participants' computer use ability tended to be higher in proportion to the increase of computer use abilities in spreadsheet (F=2.606. p=.048). presentation (F=3.62. p=.012) and communication/internet(F=2.885. p=.0321. Based on the study results mentioned above. I will suggest as follows : The nationwide enlargement and repetition study is required for occupational nurses who serve in occupational nursing fields. The computerization system in a health service field is inferior comparing with other fields. The computerization system standard by business types and characteristics should be prepared through employers's aggressive participation and national support. Therefore various statistical data which occurs in occupational fields will be managed systematically and efficiently. A regular and systematic computer education plan for occupational nurses in charge of health services in the filed is urgently required to efficiently manage and improve the health of on-site workers.

  • PDF