• 제목/요약/키워드: Determining the phase

검색결과 520건 처리시간 0.029초

Study of Short-Circuit Currents Around Dĕtmarovice Power Station

  • Ali, Shehab Abdulwadood
    • Transactions on Electrical and Electronic Materials
    • /
    • 제15권3호
    • /
    • pp.117-124
    • /
    • 2014
  • The calculation of short-circuit currents is important for power systems operation and restoration, and for determining the means to protect human lives and properties. In this paper, a part of a power system network, around the D$\breve{e}$tmarovice power station in Czech Republic, was simulated by the well known program EMTP-ATPDraw (Electromagnetic Transients Program-Alternative Transient Program), and short-circuit currents and voltages were calculated at different points in the electric network and presented as a time function by the PlotXY program. Calculations were done just for phase-to-ground, and for the three-phase short-circuit at the Kun$\check{c}$ice substation. The results were important for determining the characteristics of the equipment required to withstand or break the short-circuit current; for this reason, the calculations were repeated using earth-fault resistances only for the case of busbar KUN shown in Figs. 5 and 6.

디지털제어기의 제어주기 결정방법에 관한 연구 (A new criterion for determining the sampling rate of digital controller)

  • 이준화;문홍주;정병근
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2000년도 제15차 학술회의논문집
    • /
    • pp.360-360
    • /
    • 2000
  • In this paper, a new criterion f9r determining the sampling rate of digital conroller is proposed. This paper will introduce a method fur determining the appropriate sampling rate of digital controller which can be substituted with the given analog controller, using phase margin and gain cross over frequency, not rising time or bandwidth of the closed-loop system. This method also guarantees performance of the system. Without exact modeling functions of the plant, abstracting those functions, this paper can achieve stability and aimed performance of the system, and this paper proved it with proper modeling functions.

  • PDF

와이어 가공 조건 자동 생성 2 단계 신경망 추정 (Automatic Generation of Machining Parameters of Electric Discharge Wire-Cut Using 2-Step Neuro-Estimation)

  • 이건범;주상윤;왕지남
    • 한국정밀공학회지
    • /
    • 제15권2호
    • /
    • pp.7-13
    • /
    • 1998
  • This paper presents a methodology for determining machining conditions in Electric Discharge Wire-Cut. Unification of two phase neural network approach with an automatic generation of machining parameters is designed. The first phase neural network, which is 1 to M backward-mapping neural net, produces approximate machining conditions. Using approximate conditions, all possible conditions are newly created by the proposed automatic generation procedure. The second phase neural net, which is a M to 1 forward-mapping neural net, determines the best one among the generated candidates. Simulation results with ANN are given to verify that the presenting methodology could apply for determining machining parameters in Electric Discharge Wire-Cut.

  • PDF

마이크로파 광대역 정위상기 (Microwave Wideband Constant Phase Shifter)

  • Bae, Jung-Yi
    • 대한전자공학회논문지
    • /
    • 제23권2호
    • /
    • pp.182-188
    • /
    • 1986
  • A method of wideband constant phase control is proposed. This can be applied to reflection type phase shifter with p-i-n diode. Using the proposed method, a microwave phase network which consists of a transmission line and reactive circuit element is suggested. By determining theproper values of design parameters, the desired wideband constant phase with different specification can easily be designed. Also, using the proposed method, the parameters variation, and 1.1 dB of insertion loss in the range of 12% bandwidth.

  • PDF

선형 위상 신호를 이용한 위상속도 측정에 관한 연구 (A Study on Phase Velocity Measurement using Linear Phase Signal)

  • 고덕영;김계국;이종악
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1988년도 전기.전자공학 학술대회 논문집
    • /
    • pp.51-54
    • /
    • 1988
  • In this paper, Digital signal processing method is deserved by the tissue characteristic quantization. Linear phase velocity is studied using linear signal, and the slope which attenuation characteristics are decreased is analysed according to frequency increase. A more efficient method determining the minimum phase function is developed from the spectral magnitud function.

  • PDF

방향 판별 분산간섭계의 최적 분산 조건 연구 (Optimal Dispersion Condition to Distinguish OPD Directions of Spectrally-Resolved Interferometry)

  • 윤영호;김대희;주기남
    • 한국정밀공학회지
    • /
    • 제34권4호
    • /
    • pp.259-264
    • /
    • 2017
  • Spectrally resolved interferometry (SRI) is an attractive technique to measure absolute distances without any moving components. In the spectral interferogram obtained by a spectrometer, the optical path difference (OPD) can simply be extracted from the linear slope of the spectral phase. However, SRI has a fundamental measuring range limitation due to maximum and minimum measurable distances. In addition, SRI cannot distinguish the OPD direction because the spectral interferogram is in the form of a natural sinusoidal function. In this investigation, we describe a direction determining SRI and propose the optimal conditions for determining OPD direction. Spectral phase nonlinearity, caused by a dispersive material, effects OPD direction but deteriorates spectral interferogram visibility. In the experiment, various phase nonlinearities were measured by adjusting the dispersive material (BK7) thickness. We observed the interferogram visibility and the possibility of direction determination. Based on the experimental results, the optimal dispersion conditions are provided to distinguish OPD directions of SRI.

액체와 투과형 편향법을 이용한 광학부품의 굴절률 분포 측정 (Determining the Refractive Index Distribution of an Optical Component Using Transmission Deflectometry with Liquids)

  • 신상훈;유영훈
    • 한국광학회지
    • /
    • 제25권6호
    • /
    • pp.326-333
    • /
    • 2014
  • 액체 속에 담긴 시료를 투과형 편향법을 이용하여 3차원 형상을 측정하고 시료의 굴절률 분포를 측정하였다. 편향법은 면적이 비교적 크고 거울과 같이 산란이 거의 없는 물체의 3차원 측정을 하는데 유용하다. 편향법을 통해 얻은 왜곡 무늬로부터 위상과 기울기를 구하기 위해 위상이동법과 시간추적 위상펼침 (TPU:Temporal Phase Unwrapping) 방법을 이용하였고, 구한 기울기로부터 높이를 구하기 위해 최소자승법을 이용하였다. 굴절률 분포 측정을 위해 2개의 유체를 이용하였다. 전산기 시늉과 실험결과 액체를 이용한 투과형 편향법을 이용하여 시료내의 굴절률 분포를 측정 할 수 있음을 확인하였다.

Parameter Estimation of Three-Phase Induction Motor by Using Genetic Algorithm

  • Jangjit, Seesak;Laohachai, Panthep
    • Journal of Electrical Engineering and Technology
    • /
    • 제4권3호
    • /
    • pp.360-364
    • /
    • 2009
  • This paper suggests the techniques in determining the values of the steady-state equivalent circuit parameters of a three-phase induction machine using genetic algorithm. The parameter estimation procedure is based on the steady-state phase current versus slip and input power versus slip characteristics. The propose estimation algorithm is of non-linear kind based on selection in genetic algorithm. The machine parameters are obtained as the solution of a minimization of objective function by genetic algorithm. Simulation shows good performance of the propose procedures.

이족보행로봇의 비충격 걸음새를 위한 제어에 관한 연구 (A study on the control for impactless gait of biped robot)

  • 박인규;김진걸
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1997년도 한국자동제어학술회의논문집; 한국전력공사 서울연수원; 17-18 Oct. 1997
    • /
    • pp.536-539
    • /
    • 1997
  • This paper presents a three dimensional modeling and a trajectory generation for minimized impact walking of the biped robot. Inverse dynamic analysis and forward dynamic analysis are performed considering impact force between the foot and ground for determining the actuator capacity and for simulating the proposed biped walking robot. Double support phase walking is considered for close to human's with adding the kinematic constraints on the one of the single support phase.

  • PDF

단상 UPS 제어기 설계 및 개발 (Development and design of single-phase uninterruptible power supply)

  • 김형섭;유은식;이동명
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2014년도 추계학술대회 논문집
    • /
    • pp.203-204
    • /
    • 2014
  • In this paper, single-phase uninterruptible power supply design method is presented. In this control scheme, input current, output current and output voltage are used. For voltage control PR controller is used and that for current controller is PI controller. The gains for controllers are sought by the classical method for determining gains. Throughout simulations the performance of single-phase UPS is verified.

  • PDF