• Title/Summary/Keyword: Deterioration Progress

Search Result 96, Processing Time 0.028 seconds

Deterioration Diagnostic Techniques for Power Facilities by Analyzing Pulse-Height of leakage current (누설전류 파고분석에 의한 전력설비의 열화진단 기술)

  • 한주섭;김명진;손원진;길경석
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2001.10a
    • /
    • pp.367-370
    • /
    • 2001
  • This paper proposes a new deterioration diagnostic technique for power facilities by analyzing the pulse-height analysis of leakage current. Until now, various deterioration diagnostic techniques to prevent power system failures by deterioration of power facilities are suggested, and most of which measures leakage current amplitude only as a estimation parameter. In this experiment, it is known that the pulse heights of the leakage current are increased according to deterioration progress as well as there comes remarkable changes in pulse height distribution thereto. Therefore, the use of pulse height distribution in deterioration diagnostic technique makes more accurate diagnosis than the conventional method by using only leakage current value. From the application test, it is confirmed that the proposed technique has sufficient performance to diagnose deterioration of power facilities.

  • PDF

Electrical Characteristics of ZnO Blocks by a Lightning Impulse Current and the Expert System to Diagnose Arrester Deterioration (뇌충격전류에 의한 산화아연형 피뢰기 소자의 전기적 특성과 피뢰기 열화진단 전문가 시스템)

  • Gil, Gyeong-Seok;Han, Ju-Seop;Song, Jae-Yong;Kim, Myeong-Jin;Kim, Jeong-Bae;Jo, Han-Gu
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.51 no.4
    • /
    • pp.152-157
    • /
    • 2002
  • This paper describes an effect of a single- and a quadruple-lightning impulse currents on electrical characteristics of ZnO blocks, and an expert system to diagnose arrestor deterioration. To deduce the parameters needed for diagnosing arrester deterioration, an accelerate deterioration teat is carried out. In the experiment, leakage current components are measured. Also, wave height distribution of the leakage current according to the progress of arrester deterioration is analyzed. From the experimental results, the wave height distribution of the leakage current showed conspicuous difference even in an immaterial leakage current increase. Therefore, the use of wave height distribution of the leakage current in deterioration diagnostic technique makes more accurate diagnosis than the conventional method by using only a leakage currant value. Finally, the expert system based on the experimental results is developed and the system can diagnose arrestor deterioration by measuring the leakage current and its wade height distribution.

Relationship between threatened vascular plants and the human population in Japan

  • Hayashi, Naoki;Watanabe, Eriko;Matsuda, Hiroyuki
    • Journal of Ecology and Environment
    • /
    • v.35 no.4
    • /
    • pp.331-341
    • /
    • 2012
  • Using data sets for Japan as a whole, as arranged with approximately $10{\times}10$ km squares (a secondary grid), we investigated the relationship between population density and the habitats of threatened vascular plants listed in the Japanese Red Data Book; depopulated areas in the present and future, areas where under-use may be serious, and those with a predominance of elderly people; and the present state of the habitats in terms of a characteristic land use pattern. Regarding the habitats of threatened vascular plants, the progress of deterioration [$(N_{CR}+N_{EN})/(N_{CR}+N_{EN}+N_{VU})$] in depopulated areas has been confirmed, where $N_{CR}$, $N_{EN}$, and $N_{VU}$ are the numbers of species classified as critically endangered, endangered, and vulnerable, respectively. Moreover, in grid squares used by a human such as farmland, the progress of the deterioration simply increases when population density becomes low. However, for many vascular plants, they are particularly endangered in populous areas. Local populations will decrease throughout Japan with the rate of depopulation in and around large cities being relatively slow. We also propose some issues that need further study. The deterioration by human activity may be reduced. On the other hand, some vascular plants may be adversely influenced by depopulation. Additionally, we should keep a close watch on grasslands and water areas in large cities to preserve vascular plants.

A Bayesian Regression Model to Estimate the Deterioration Rate of Track Irregularities (궤도틀림 진전율 추정을 위한 베이지안 회귀분석 모형 연구)

  • Park, Bum Hwan
    • Journal of the Korean Society for Railway
    • /
    • v.19 no.4
    • /
    • pp.547-554
    • /
    • 2016
  • This study considered how to estimate the deterioration rate of the track quality index, which represents track geometric irregularity. Most existing studies have used a simple linear regression and regarded the slope of the regression equation as the progress rate. In this paper, we present a Bayesian approach to estimate the track irregularity progress. This Bayesian approach has many advantages, among which the biggest is that it can formally include the prior distribution of parameters which can be derived from historic data or from expert experiences; then, the rate can be expressed as a probability distribution. We investigated the possibility of applying the Bayesian method to the estimation of the deterioration rate by comparing our bayesian approach to the conventional linear regression approach.

Analysis of The Behavior of Kurtosis By Simplified Model of One Sided Affiliated Impact Vibration

  • Takeyasu, Kazuhiro;Higuchi, Yuki
    • Industrial Engineering and Management Systems
    • /
    • v.4 no.2
    • /
    • pp.192-197
    • /
    • 2005
  • Among many amplitude parameters, Kurtosis (4-th normalized moment of probability density function) is recognized to be the sensitive good parameter for machine diagnosis. Kurtosis has a value of 3.0 under normal condition and the value generally goes up as the deterioration proceeds. In this paper, simplified calculation method of kurtosis is introduced for the analysis of impact vibration with one sided affiliated impact vibration which occurs towards the progress of time. That phenomenon is often watched in the failure of such as bearings’ outer race. One sided affiliated impact vibration is approximated by one sided triangle towards the progress of time and simplified calculation method is introduced. Varying the shape of one sided triangle, various models are examined and it is proved that new index is a sensitive good index for machine failure diagnosis. Utilizing this method, the behavior of kurtosis is forecasted and analyzed while watching machine condition and correct diagnosis is executed.

A Study on the Deterioration Progress of Railway Arresters (철도용 피뢰기의 열화진전에 관한 연구)

  • 길경석;한주섭;한문섭
    • Journal of the Korean Society for Railway
    • /
    • v.7 no.4
    • /
    • pp.307-311
    • /
    • 2004
  • Arresters are the best protective device on electrical power systems against transient overvoltages generated by lightning and/or switching operation. Nonetheless, arresters are deteriorated by absorption of moisture in the environments of its use, repetition in the protective operation to overvoltages, and some defects at manufacturing. It is therefore important to estimate the electrical characteristic changes of ZnO blocks. In this paper, an accelerated ageing test by a standard lightning impulse current was carried out to extract parameters needed for arrester diagnosis, and leakage current components were measured. Total energy applied to the ZnO blocks at each time is about 1,050[J] in 8/20[${\mu}\textrm{s}$] impulse current. From the experimental results, we proposed electrical parameters and leakage current level to diagnose arrester soundness.

Development of Deterioration Detecting System for Aged ACSR-OC Conductors in HV Overhead Distribution Lines (고압 가공배전선의 노화된 ACSR-OC 도체에 대한 열화검출시스템 설계)

  • Kim, Sung-Duck;Lee, Seung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2000.11a
    • /
    • pp.232-235
    • /
    • 2000
  • Design and experiments of a nondestructive system to inspect deterioration of ACSR-OC (ACSR Outdoor Cross-linked Polyethylene Insulated Wire usually used in HV overhead distribution lines presented in this paper. ACSR-OC conductor built to pollutants air for a long period would be easily progress to corrode so that it may lead to the reduction of the effective cross section area of conductors. A fault diagnosis system consisting of a solenoid sensor, a constant current source with RF frequency signal processing unit and a motor driver/controller designed and implemented. This instrument can dot the sensor output variation due to deterioration corrosion, continuously. As a result, it was shown such corrosion detector can readily be utilized estimating the diameter change due to deterioration overhead distribution lines and in giving an warning or inform before severe aged conductor lead to fail.

  • PDF

Influence of System Voltage Harmonics on Arrester Deterioration Diagnostic Techniques by Leakage Current Measurement (누설전류측정에 의한 피뢰기 열화진단기술에 있어 전원고조파의 영향)

  • Kil, Gyung-Suk;Han, Joo-Sup
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.08a
    • /
    • pp.142-145
    • /
    • 2002
  • This paper describes an influence of system voltage harmonics on arrester deterioration diagnostic techniques based on leakage current measurement because the resistive current is composed of two components caused by nonlinear characteristics of arrester and by system voltage harmonics. Resistive leakage currents of arresters, which can be evaluated by the third harmonic component of total leakage currents, increase with its deterioration progress. In this paper, we developed a PSpice model for ZnO arrester to simulate the harmonics' effect described above. In simulation, pure sinusoidal voltage and the $3^{rd}$ harmonic voltage are applied to the model, and the leakage current changes are compared. The simulation results showed that the magnitudes of resistive leakage current depend not only on the phase of system voltage harmonics but also on the magnitude of it.

  • PDF

Shear Deterioration of RC Beams after Flexural Yielding (휨항복 후 전단 파괴하는 철근콘크리트 보의 전단 성능 저하)

  • 이정윤
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.10a
    • /
    • pp.583-588
    • /
    • 2000
  • While a great progress has been achieved in predicting the ultimate shear strength in the RC members, it is a fact that a method in order to estimate the ductility of RC members still has to be looked for. This study theoretically predict the ductility of RC beams which fail in shear after flexural yielding by considering the deterioration of concrete strength in plastic hinge region.

  • PDF

A Study on Deterioration in Polymer Insulating Material at Cryogenic Temperature (극저온중의 고분자 절연재료의 열화연구)

  • 김현희;김영석;김상현;최효상;조광욱
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1996.11a
    • /
    • pp.311-315
    • /
    • 1996
  • This Paper is to discribe the ac treeing deterioration in Polyethylenetherphthalate (PET) at various temperature. The AC tree was investigated at 77K using L$N_2$. The experimental results show that V-t characteristics was an inverse proportion to temperature. The progress of tree initiation and growth were also to temperature.

  • PDF