• 제목/요약/키워드: Deterioration Factor

검색결과 396건 처리시간 0.024초

동결융해작용을 받는 콘크리트의 열화예측에 관한 연구 (Study on the Prediction of Concrete Deterioration Subjected to Cyclic Freezing and Thawing)

  • 고경택;이종석;이장화;조명석;송영철
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 학회창립 10주년 기념 1999년도 가을 학술발표회 논문집
    • /
    • pp.795-798
    • /
    • 1999
  • Deterioration induced by the freezing and thawing in concrete often leads to the reduction in concrete durability by the cracking or surface spalling. In this paper, the deterioration prediction model for concrete structures subjected to the irregular freeze-thaw was proposed from the results of accelerated laboratory test using the constant temperature condition and acceleration factor from the in-situ weather data.

  • PDF

동특성 추정 기법과 신뢰성 해법에 의한 기설교량의 내하력 판정 방법 (A RELIABILITY-BASED CAPACITY RATING OF EXISTING BRIDGES BY INCORPORATING SYSTEM IDENTIFICATION)

  • Cho, Hyo-Nam;Yun, Chung-Bang
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1990년도 봄 학술발표회 논문집
    • /
    • pp.37-43
    • /
    • 1990
  • This paper develops practical models and methods for the assessment of safety and rating of damaged and/or deteriorated bridges by incorporating a system identification technique for the explicit inclusion of the degree of deterioration or damage and of the actual bridge response. And, based on the proposed model, reliability-based rating methods are proposed as LRFR(Load and Resistance Factor Rating) and system reliability-index rating criteria. The proposed limit state model explicitly accounts for the degree of deterioration or damage in terms of the damage and response factors. The damage factor in the paper is proposed as the ratio of the current stiffness to the intact stiffness. Based on the observation and the results of applications to existing bridges, it may be concluded that the proposed rating models, which explicitly account for the uncertainties and the effects of degree of deterioration or damage based on the system identification technique, provide more realistic and consistent safety-assessment and capacity-rating.

  • PDF

염화물 함유에 의한 콘크리트의 내동해성 및 표면열화에 관한 연구 (A Study on the Scaling Deterioration and Resistance to Freezing of Concrete by Containing Chlorides)

  • 박주헌;김규용;김한준;권영호
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 춘계 학술발표회 제16권1호
    • /
    • pp.372-375
    • /
    • 2004
  • Scaling deterioration and resistance to freezing of port concrete structures due to the combined effects of chemical actions by containning chlorides and the freeze-thaw action is also a problem which has not yet been fundamentally solved. Furthermore, deterioration of concrete surface was considered as accelerate factor of concrete durability tended to decrease. Therefore, we considered the scaling measuring method and decreasing influence of durability of concrete according to kind of binders, such as OPC, Slag, Slag+Fa, due to freeze and thaw of concrete by containing chlorides. As a results of this study, it was effective method of scaling deterioration and resistance freewing of concrete, and confirmed the salt deterioration resistance effect to use slag binder against to containing chlorides.

  • PDF

해수동결융해작용에 의한 콘크리트의 표면열화에 관한 연구 (A Study on the Concrete Scaling Deterioration due to Freezing and Thawing of Sea Water)

  • 김규용;박주현;김규동;이승훈
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 가을 학술발표회 논문집
    • /
    • pp.54-57
    • /
    • 2003
  • Scaling deterioration of port concrete structures due to the combined effects of chemical actions by seawater and the freeze-thaw action is also a problem which has not yet been fundamentally solved. Furthermore, deterioration of concrete surface was considered as accelerate factor of concrete durability tended to decrease. Therefore, we considered the scaling measuring method and decreasing influence of durability of concrete according to kind of binders, such as OPC, Slag, Slag+Fa, due to freeze and haw of sea water. As a results of this study, it was effective method of scaling deterioration of concrete, and confirmed the salt deterioration resistance effect to use slag binder against to sea water.

  • PDF

현장측정을 통한 자갈도상궤도의 동적 거동 분석 (A Study on the Dynamic Behaviors of Ballast Track using Field Test)

  • 박용걸;최정열
    • 한국철도학회논문집
    • /
    • 제9권4호
    • /
    • pp.401-411
    • /
    • 2006
  • The major objective of this study is to investigate the dynamic behaviors of track due to the deterioration characteristics of ballast for servicing tracks by the field test. The durability of ballast plays an important role in the track behaviour. To estimate the deterioration characteristics of ballast, several tests have been carried out by several scholars. The deterioration characteristics of ballast is one of the most important factor in the dynamic behaviour of track and its life. In this paper abrasion/breakage characteristics of ballast is studied to predict the effect of physical ballast characteristics on ballast track. To reveal deterioration characteristics of ballast, the field test were carried out. The deterioration characteristics, studied in this paper, is applied to the dynamic behaviour of track in various conditions.

현장측정을 통한 자갈도상 궤도의 동적 거동 분석 (A Study on the Dynamic Behaviors of Ballast Track using Field Test)

  • 최정열;박균서;류중열;박정근;류경식;박용걸
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2006년도 추계학술대회 논문집
    • /
    • pp.494-507
    • /
    • 2006
  • The major objective of this study is to investigate the dynamic behaviors of track due to the deterioration characteristics of ballast for servicing tracks by the field test. The durability of ballast plays an important role in the track behaviour. To estimate the deterioration characteristics of ballast, several tests have been carried out by several scholars. The deterioration characteristics of ballast is one of the most important factor in the dynamic behaviour of track and its life. In this paper abrasion/breakage characteristics of ballast is studied to predict the effect of physical ballast characteristics on ballast track. To reveal deterioration characteristics of ballast, the field test were carried out. The deterioration characteristics, studied in this paper, is applied to the dynamic behaviour of track in various conditions.

  • PDF

운행차 열화특성을 고려한 제작차 배출가스 목표치 설정에 관한 연구 (A Study on the Target Values Fixing of Green Vehicle Emissions in Consideration of In-use Deterioration)

  • 김현우
    • 한국자동차공학회논문집
    • /
    • 제11권2호
    • /
    • pp.104-110
    • /
    • 2003
  • As exhaust emission standards are more stringent, higher conversion efficiency of automotive catalytic converter is required. In addition, catalytic converter is deteriorated during mileage accumulation of vehicle. Therefore the specification of catalytic converter should be decided in consideration of emission standards and deterioration. Because the decision of the specification of catalytic converter is required at the beginning of vehicle development procedure, it is important and necessary to fix the target values of green vehicle exhaust emissions. To do this, a linear regression analysis was done with in-use exhaust emissions data of 5 different kinds of vehicle that received US94 emission standards certification, and data handling methods including some statistical estimation were proposed. As a result, the fixed target values of NMHC, CO, NOx of green vehicle against US94 emission standards were 0.079, 0.83, 0.116, respectively. And expected in-use deterioration factor of NMHC, CO, NOx were 1.75, 2.02, 1.38, respectively. And also it was blown that even if failure rate is 30% after 80,000km driven, it might be sufficiently safe from emission failure confirmatory test of Korea. It is hopeful to make a database of in-use emissions to increase the confidence in correctness of the calculated target values.

MPPF 커패시터의 전기적, 열적 열화시 소체의 화학적특성에 관한 연구 (A Study on Chemical Characteristic of Electrically and Thermally Treated MPPF Capacitor Elements)

  • 구교선;송현석;이동준;곽희로;송길목
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.227-230
    • /
    • 2001
  • This paper divides the factors of an accident into two parts, that are electrical deterioration and thermal deterioration, to analyze a characteristic of the factor of an accident which can break out in the capacitor of metal vaporized polypropylene film. For the purpose of creating capacitor which is caused by electric deterioration, we applied DC overvoltage, induced self-healing and breakdown from element. We applied gradual heat to get an element which is cause by thermal deterioration. The chemical structure of the shape and surface is analyzed by thermogravimetric analyzer (TGA), Scanning Electron Microscope (SEM) and Fourier Transform Infrared Spectrometer(FT-IR). As a result, the peak of methylene group came out, in case of electrical deterioration, as observing the self-healing point. However, the peak is disappeared in the heat treated element by 500[$^{\circ}C$], and the peak of carbonyl group which has C=O came out in case of thermal deterioration.

  • PDF

남한산성 여장 손상원인 분석 (Factor Analysis of Deterioration in Namhansanseong Yeojang)

  • 정광용;이상옥;양희제
    • 건축역사연구
    • /
    • 제25권1호
    • /
    • pp.59-68
    • /
    • 2016
  • There are many reasons of damage in Namhansanseong Yeojang. Lots of damage types are observed in each Yeojang. There are many types of damage factors but major damage factor is breakage by freezing and thawing. So Conduct non-destructive evaluation about damage factors in Namhansanseong Yeojang to analysis weathering factors in Yeojang by measuring directional microclimate. The study will pave the way for conservation management in Namhansanseong by suggesting the conservation calendar about weather condition and damage factors.

자동차(自動車) 배출(排出)가스 시험(試驗)에서 3 공해요소(公害要素)에 대한 변화요인(變化要因) (DF) 분포(分布)에 관한 연구(硏究) (A Study on the Distribution of the Deterioration Factor for Three Pollutants in Motor Vechicle Emission Test)

  • 조재립;황의철
    • 품질경영학회지
    • /
    • 제15권2호
    • /
    • pp.2-9
    • /
    • 1987
  • The Deterioration Factor (DF) for a single pollutant within an engine family is computed as the ratio of two points on a linear regression line describing durability vehicle test results as a function of accumulated mileage. It is inteded to represent the factor by which emissions will increase during the ''useful life" of a vehicle in the engine family. Here are discribed procedures for computing the DF and how consideration of the DF is included in the development for the motor vehicle emission certification process. This paper is aimed to develop the distribution of the DF for three pollutant and to estimate the parameter values for the distribution of the DF.