A Study on the Properties of Fire Endurance and Spalling of High Performance RC Column with the Finishing and Covering Material (고성능 RC 기둥의 마감재 변화에 따른 폭열 및 내화특성에 관한 연구)

  • Han, Cheon-Goo;Hwang, Yin-Seong;Ji, Suk-Won;Kim, Kyoung-Min
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.10 no.2
    • /
    • pp.143-152
    • /
    • 2006
  • High performance concrete(HPC) has been widely used in high-rise building. The HPC has several benefits including high strength, high fluidity and high durability. However, spalling is susceptible to occur in HPC and HPC also tends to be deteriorated in the side of fire resistance performance at fire. This paper investigated the spalling prevention of high performance RC column. Control concrete showed severe failure and a case of concrete with fire enduring spraying material exhibited more severe spalling failure than even control concrete. In addition, concrete with fire enduring paint reported the most favorable spalling resistance effect for preventing spall, compared with other concrete covered with finishing materials, such as fire enduring spraying material, gypsum board, marble board and fire enduring PC board. Meanwhile, concrete adding 0.1% of PP fiber demonstrated spalling resistance performance after 3hours load bearing test.

Development of the Smart Concrete Using Electric Resistance (전기 저항을 이용한 스마트 콘크리트의 개발)

  • 김화중;김이성;김형준
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2004.04a
    • /
    • pp.447-453
    • /
    • 2004
  • Various structural materials have been used in construction projects using stones, connotes, and steels materials. Among of these projects, concretes may use widely because concretes have high compressive strength, and comparatively easy maintenance and management. Reinforced concrete Buildings will be deteriorated as time passed. These problems will be accelerated by propagation of cracks. In order to manage such cracks, time, efforts and expense are required. In this study, leakages of fluorescence and adhesive material were investigated using glass sensors that were embedded in a model beam and column. In addition, currents in glass pipe sensor were observed to find leakage of liquid in glass pipes. Progressive cracks were generated by fracture of glass me sensor. In this investigation, a reinforcement clothing system was wrapped for a glass pipe sensor, The glass pipe sensor that can make control and reinforce cracks simultaneously.

  • PDF

An Experimental Study on Damage Detection of PSC Beams using Vibration Test (진동 시험을 통한 PSC 보의 손상탐지에 대한 실험적 연구)

  • Jung Woo-Tae;Park Jong-Sup;Park Young-Hwan;You Young-Jun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.05a
    • /
    • pp.96-99
    • /
    • 2004
  • PSC bridges are deteriorated by many reasons and are difficult to measure residual prestressing forces. It is considered that one of the methods for measuring the prestressing forces is vibration test. This study reports on the change of natural frequency for damaged PSC beams using vibration test which have been carried out to evaluate the effects of cross-section and prestressing forces on natural frequency of PSC beams. According to the results of vibration test results, natural frequency is more sensitive to the changes of cross-section than those of prestress.

  • PDF

Experimental Study on Behavior of Bonding between PSC Girders and Precast Decks (PSC 거더와 프리캐스트 바닥판간 부착 강도 평가를 위한 실험적 연구)

  • Kim In Gyu;Chung Chul Hun;Shim Chang Su;Kim Seong Woon
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.05a
    • /
    • pp.770-773
    • /
    • 2004
  • The full-width, full-depth precast panel system is very efficient for the rehabilitation of deteriorated decks as well as for new bridge construction.. The horizontal bond strength at the interface between the two interconnected elements is of primary importance in order to achieve composite action. The strength of the bond between the two precast members should be high enough to prevent any progressive slip from taking place. However, the case when both of the interconnected elements are precast members bonded by means of grout, is not currently addressed by KBDC or AASHTO. This is the main impetus for this study. A total 43 push-off tests were performed to evaluate the horizontal bond strength and to recommend the best practice for the system. Test parameters included different interface surface conditions, different amount and different types of shear connectors. The presence of the shear keys at the top surface of the beam increased the interface bond capacity tremendously compared to the bond capacity with a different surface conditions.

  • PDF

Study on the Life Cycle Management System of the Marine Transmission Tower Structures (해상철탑구조물의 수명관리방안 연구)

  • Pang, Gi-Sung;Song, Young-Chul;Yoon, Deok-Joong;Kim, Do-Gyeum
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05b
    • /
    • pp.281-284
    • /
    • 2006
  • The marine Transmission tower infrastructure erected in the SI-HWA lake is deteriorated and damaged by the various environment effect, and then, there is a possibility of going bad in the safety. The appropriate maintenance to ensure the security of the structure during life cycle is necessary. Specially the Jacket or the steel file foundation in the sea is apt to be corroded quickly. In this research, to establish life management system of 345kV Yonghung marine transmission tower structure, the actual durability research facility which can obtain the actual proof data is constructed. the maintenance guideline and procedure of the structure are established. Hereafter, there is a plan which will advance the research against the composition of the life prediction model, which is based on the data acquired from the actual durability research facility.

  • PDF

An Experimental Study on Shear Strengthening of the R/C Deep Beams Using Carbon and Aramid Fibers (탄소 및 아라미드섬유를 이용한 철근콘크리트 깊은 보의 전단보강에 관한 실험적 연구)

  • Jo, Byung-Wan;Kim, Young-Jin
    • Journal of Ocean Engineering and Technology
    • /
    • v.13 no.3B
    • /
    • pp.56-64
    • /
    • 1999
  • An experimental study was carried out to examine the structural behavior of reinforced concrete deep beams strengthened with aramid fiber sheets, carbon fiber sheets and plates, and to propose the reasonable strengthening method for the deteriorated R.C. deep beams. Results show that the most significant differences in behavior of reinforced concrete deep beams strengthened with fiber sheet and plate were mainly due to various fiber orientations and anchorage. Deep beams diagonally strengthened with carbon fibers show better performance compared with those of vertically, horizontally strengthened specimens and produce the increase in the shear resistance through the redistribution of internal forces after the initial cracks occur. However, strengthened deep beams without anchorages might show unreasonable, brittle peeling-off failure of fiber reinforcements.

  • PDF

Properties of Cement Mortar Using Mica Waste as Fine Aggregate (운모폐석을 잔골재로 사용한 시멘트 모르타르의 특성)

  • 윤기원;김광화;오상백;한민철;류현기;한천구
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.11a
    • /
    • pp.481-484
    • /
    • 2003
  • This study is intended to investigate application of mica waste(MS) to fine aggregate for mortar by comparing it with cement mortar in which crushed sand(CS) and river sand(NS) are used. According to the results, as the physical properties of aggregate, specific gravity is large in order of MS, NS and CS, absorption ratio in order of MS, CS and NS, and unit weight and solid volume percentage in order of NS, CS and MS. In the case of MS mortar, mechanical properties, drying shrinkage and heat conduction ratio are reduced, but the radiative amount of infrared light is excellent compared with NS mortar. Fluidity and unit weight of MS mortar is larger than those of CS mortar, and strength does not make differences. Length change by drying shrinkage is larger, but heat conduction ratio and radiative amount of infrared light are smaller than CS mortar. Thus, it proves that MS can be used in place of NS and CS, but its quality is deteriorated slightly.

  • PDF

Fire-induced damage on Shield TBM concrete segment (터널 화재로 인한 콘크리트 세그먼트의 손상특성 규명)

  • Choi, Soon-Wook;Chang, Soo-Ho;Lee, Gyu-Phil;Bae, Gyu-Jin
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.423-430
    • /
    • 2005
  • Fire accidents in underground space may bring much loss of lives as well as properties and result in catastrophic disasters. This study aimed to manufacture the high-temperature furnace capable of simulating fire scenarios (RABT and RWS) and carry out the preliminary fire tests to evaluate fire-induced damage in underground structures. Specimens used in the fire tests were the concrete segments generally used in shield TBM tunnels. The simulated fire scenario was set to the RABT curve that is the most representative fire scenario in underground space. From the fire tests, the spalling was estimated to reach approximately 20cm from the surface exposed to fire. In addition, from the observation of core specimens obtained after fire tests, the deteriorated zone of unspalled specimens amounted to approximately 10cm from the surface of spalling.

  • PDF

Development of Using Technique of Impregnating Alkalization Agent to Recover Durability of Carbonated Reinforcement Concrete Structures by Fire Damages (화재로 인해 중성화된 철근콘크리트구조물의 내구성 회복을 위한 침투성 알칼리성부여제의 이용기술개발)

  • Moo-Han, Kim;Yong-Ro, Kim;Jea-Bong, Jang
    • Fire Science and Engineering
    • /
    • v.18 no.3
    • /
    • pp.18-24
    • /
    • 2004
  • Fire breaking out in carbonated reinforcement concrete structures considerably deteriorates the durability of them by propelling carbonation. However, the research and technical development to recover the durability is still in an underdeveloping stage in Korea. Therefore, this research aims to understanding the deteriorated durability of a carbonated structure, evaluating the performance of an impregnating alkalization agent to recover the durability and developing a way of using it.

Strengthening Evaluation of Post-Tensioning Due to Anchorage System (정착방법에 따른 외부 프리스트레이트 도입공법의 보강성능 평가)

  • 박승범;홍석주
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.04a
    • /
    • pp.279-284
    • /
    • 2000
  • The bridge is nation's principal structure and its influence for national economy is enormous. But it is essential for maintenance of deteriorated bridge because of the increased service life and the decreased performance. For the bridge reinforced by continuos slabs and post-tensioning, we evaluate th stress properties of girders and internal support. Results are almost coincidence between measured data in the field and analysed data by computer. We compared the effects by successive order of post- tensioning and order considered distribution of each girder's camber and stress. Bridge's camber and stress showed respectively symmetry and asymmetry shape by post tensioning order. For the effect of post-tensioning force partition, we divided the post-tensioning force into 3 types (100%, 20%, 30%), and the results show t도 difference of final stress and camber.