• 제목/요약/키워드: Detector materials

검색결과 503건 처리시간 0.025초

Optimal Density Assignment to 2D Diode Array Detector for Different Dose Calculation Algorithms in Patient Specific VMAT QA

  • Park, So-Yeon;Park, Jong Min;Choi, Chang Heon;Chun, Minsoo;Han, Ji Hye;Cho, Jin Dong;Kim, Jung-in
    • Journal of Radiation Protection and Research
    • /
    • 제42권1호
    • /
    • pp.9-15
    • /
    • 2017
  • Background: The purpose of this study is to assign an appropriate density to virtual phantom for 2D diode array detector with different dose calculation algorithms to guarantee the accuracy of patient-specific QA. Materials and Methods: Ten VMAT plans with 6 MV photon beam and ten VMAT plans with 15 MV photon beam were selected retrospectively. The computed tomography (CT) images of MapCHECK2 with MapPHAN were acquired to design the virtual phantom images. For all plans, dose distributions were calculated for the virtual phantoms with four different materials by AAA and AXB algorithms. The four materials were polystyrene, 455 HU, Jursinic phantom, and PVC. Passing rates for several gamma criteria were calculated by comparing the measured dose distribution with calculated dose distributions of four materials. Results and Discussion: For validation of AXB modeling in clinic, the mean percentages of agreement in the cases of dose difference criteria of 1.0% and 2.0% for 6 MV were $97.2%{\pm}2.3%$, and $99.4%{\pm}1.1%$, respectively while those for 15 MV were $98.5%{\pm}0.85%$ and $99.8%{\pm}0.2%$, respectively. In the case of 2%/2 mm, all mean passing rates were more than 96.0% and 97.2% for 6 MV and 15 MV, respectively, regardless of the virtual phantoms of different materials and dose calculation algorithms. The passing rates in all criteria slightly increased for AXB as well as AAA when using 455 HU rather than polystyrene. Conclusion: The virtual phantom which had a 455 HU values showed high passing rates for all gamma criteria. To guarantee the accuracy of patent-specific VMAT QA, each institution should fine-tune the mass density or HU values of this device.

비파엽 품질 비교 분석을 위한 Triterpenic Acid의 추출 방법 (Development of an Effective Extraction Method for the Quality Control of Eriobotrae Folium : Determination of Triterpenic Acids)

  • 이경인;박문영;표병식;김선민
    • 생약학회지
    • /
    • 제41권1호
    • /
    • pp.62-66
    • /
    • 2010
  • In result of analysis for the content determination of ursolic acid(UA) and oleanolic acid(OA) in extract of Eriobotryae folium using HPLC with UV detector, UA in chloroform extract of Moo-mok variety was showed highest content(2.7843 mg/g). And OA in ethyl acetate extract of Dae-bang variety was showed highest content(0.5898 mg/g). These result suggest that direct extraction using organic solvent(chloroform or ethyl acetate) was useful method for rapid quantitative analysis of UA and OA without preprocessing such as drying or fractionation.

기상광반응기를 이용한 BTEX의 분해 (Decomposition of BTEX by Gas-phase Photo Reactor)

  • 이남희;이강;황두선;김세기;김선재
    • 한국재료학회:학술대회논문집
    • /
    • 한국재료학회 2003년도 춘계학술발표강연 및 논문개요집
    • /
    • pp.77-77
    • /
    • 2003
  • 산업화에 따라 각종 산업분야에서 유기 용제의 사용이 증가하게 되었고 대기오염, 수질오염 등의 상태가 심각해져가고 있는 실정이다 그러나 다양해진 오염물질을 처리하는 데 있어서 기존의 산화처리방법은 한계에 달하였고 새로운 처리공정으로 최근 고급산화법(AOP : Advanced Oxidation Process)에 대한 연구가 활발하게 진행되고 있다. 이에 본 연구에서는 대기환경 및 인체에 심각한 영향을 주는 VOCs(Voletail Organic compounds)중 BTEX(Benzene, Toluene, Ethylbenzene, Xylene)를 다양한 형태의 광촉매제를 이용하여 기상 광분해한 후 이에 대한 최적의 분해 조건과 분해율을 비교하고자 하였다. 순환식의 자체 제작한 기상광반응장치를 이용하여, CVD법으로 TiO$_2$ 입자를 알루미나 비드위에 코팅한 볼과 같은 방법으로 유리기판위에 코팅한 판상의 광촉매제 그리고 결정성이 각기 다른 루틸상과 아나타제 그리고 아나타제/루틸 혼합상의 TiO$_2$ 분말을 직접 이용하여 VOCs 농도와 종류, 광원의 종류 및 세기를 변화시켜 PID(Photo ionization Detector)방식의 순환식 VOCs 측정기를 이용하여 광분해율을 실시간으로 측정하였다.

  • PDF

메브레인 구조를 갖는 Cu-Mn-Co-Ni 산화물계 박막형 적외선 감지기 제조 (Febrication of Cu-Mn-Co-Ni-$O_4$ Thin Film Type Infrared Detector of Membrane Structure)

  • 박정희;신종배;전민석;한경섭;최덕균
    • 한국재료학회:학술대회논문집
    • /
    • 한국재료학회 2003년도 추계학술발표강연 및 논문개요집
    • /
    • pp.74-74
    • /
    • 2003
  • 적외선 감지기는 냉장고, 에어컨, 자동차용 전자부품 등의 온도측정 및 제어, 과잉 전류의 억제를 위한 소자로 널리 사용되며, 또한 최근에는 온도보상형 수정발진기(TCXO) 또는 RF모듈, 액정 판넬의 온도보상회로 등 정보통신기기의 신뢰성 향상을 위해 그 수요가 날로 증가하고 있다. 현재 상용되는 적외선 감지기의 대부분은 벌크형 또는 후막형으로 제조되고 있으나, 최근 반도체공정 기술의 발달로 인하여 보다 향상된 특성이 요구됨에 따라 박막형 등 새로운 형태의 적외선 감지기 대해 활발한 연구가 이루어지고 있다. 본 연구에서는 열 질량과 전도에 의한 열손실을 최소화하여 소자의 감도 및 응답 특성을 향상시키기 위하여 SiO$_2$Si$_3$N$_4$/SiO$_2$ (ONO)다중층 위에 소자 감지부를 형성하고 bulk-micromachining기술을 이용하여 멤브레인 구조를 갖는 박막형 적외선 감지기를 제작하였다.

  • PDF

대변형 초탄성 재료의 해석을 위한 무요소 적응기법

  • 전석기;정동원
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1995년도 추계학술대회 논문집
    • /
    • pp.736-739
    • /
    • 1995
  • The meshless adaptive method based on multiple scale analysis is developed to simulate large deformation problems. In the procedure, new particles are simply added to the orginal particle distribution because meshless methods do not require mesh structures in the formulations. The high scale component of the approximated solution detects the localized region where a refinement is needed. The high scale component of the second invariant od Green-Lagrangian strain tensor is suggested as the new high gradient detector for adaptive procedures. The feasibility of the proposed theory is demonstrated by a numerical experiment for the large deformation of hyperelastic materials.

  • PDF

Simultaneous Determination of Benzoic Acid, Caffeic Acid and Chlorogenic Acid in Seeds of Eriobotrya japonica and their Antibacterial Effect

  • Jeong, Jun-Mo;Lee, Kyoung-In;Kim, Sun-Min
    • Journal of Applied Biological Chemistry
    • /
    • 제57권1호
    • /
    • pp.89-93
    • /
    • 2014
  • We aim to develop a simple method for simultaneous and quantitative determination of benzoic acid, caffeic acid and chlorogenic acid in seeds of Eriobotrya japonica. In addition, antibacterial effect of these three phenolic acids was examined. A basic method is performed on the high performance liquid chromatography system coupled to an UV-detector (230 nm) and reverse phase C-18 column ($4.6{\times}150mm$, $5{\mu}m$). Each phenolic acid was confirmed via liquid chromatography-mass spectrometry (MS)/MS system under the multiple-reaction monitoring with negative-ion electrospray ionization (ESI(-)) mode. It is demonstrated that the method was could be applied to samples for an analytical study of the phenolic acids. On the other hand, three phenolic acids in seeds of E. japonica exhibited antibacterial effect against several pathogenic bacteria. Of these, benzoic acid was found to have stronger antibacterial effect.

변압기 절연유중 가스 검출장치의 가스 감지 특성 (Gas detection charracteristic of Transformer Oil Gas Detector)

  • 황규현;서호준;이석우;이동희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 추계학술대회 논문집 Vol.18
    • /
    • pp.323-324
    • /
    • 2005
  • To found out the degradation characteristic of transformer insulation, insulation materials and electrodes are deposited into transformer oil. They used to heated and make flashover. Due to the thermal and electrical stress added to insulation materials, the density of carbon dioxide and hydrogen included in transformer oil was increased. The gas density can measured by using the gas density detection equipment of gas sensor and air circulation method.

  • PDF

디지털 X선 영상센서 적용을 위한 진공증착 CsI 특성평가 (The X-ray Detection Characteristic of vacuum evaporated CsI for Digital X-ray Image Sensor)

  • 신정욱;박지군;최장용;석대우;김재형;남상희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 춘계학술대회 논문집 센서 박막재료 반도체 세라믹
    • /
    • pp.15-18
    • /
    • 2003
  • In recent years, there has been keen interest in phosphor materials responding X-ray. Cesium iodide of the materials is a material with a high $\gamma$-ray stopping power due to its relative high density and atomic number. CsI is noted for its high resistance to thermal and mechanical shock due to the absence of a cleavage plane. To design the structure of CsI detector, we analysed the structure with SEM and XRD and measured UV meter.

  • PDF

입상 활성탄을 이용한 형광물질 추적자시험 적용성 연구 (Feasibility of Granular Activated Charcoal as a Detector in Fluorescent Tracer Tests)

  • 이진용;황현태;이명재;김용철;염병우
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제12권4호
    • /
    • pp.86-93
    • /
    • 2007
  • 최근에 형광물질을 이용한 추적자 시험이 빈번해지고 있다. 본 연구에서는 형광물질 추적자 시험시 농도측정 방법으로서 입상 활성탄을 이용하는 방법의 적용가능성을 실내 및 현장실험을 통해 평가하였다. 실내실험 결과 로다민 WT 및 우라닌 개별용액의 경우 활성탄 흡착 농도는 실제 표준농도와는 일부 차이가 있지만 각 표준농도와 선형성은 매우 뛰어난 것으로 나타났다. 또한 $10{\mu}g/L$ 이상의 형광물질 농도에서는 활성탄의 적용성이 뛰어났다. 한편 두 형광물질을 혼합한 경우에는 간섭의 영향으로 활성탄 적용성이 떨어졌다. 실제 현장에서 활성탄을 이용하여 추적자 시험을 한 결과, 통상적으로 수행하는 직접적인 물시료 채취분석법과 비교하였을 때 활성탄을 이용한 흡착방법도 충분히 현장 적용성이 있으며 저농도에서는 습식 그리고 고농도에서는 건식으로 분석한다면 보다 정확한 형광물질 농도측정이 되는 것으로 나타났다. 특히 오염물질 확산 평가 등이 목적이 아니라 추적자 물질의 도달확인(즉 수리적 연결성 진단)이 주요 목적이고 추적자시험의 예상 소요기간이 길다면 활성탄을 활용한 방법은 매우 비용경제적일 것으로 사료된다.

몬테카를로 전산해석을 이용한 콘크리트 코어시료의 직경과 밀도에 따른 보정인자 계산 (Calculation of the Correction Factors related to the Diameter and Density of the Concrete Core Samples using a Monte Carlo Simulation)

  • 이규영;강보선
    • 한국방사선학회논문지
    • /
    • 제14권5호
    • /
    • pp.503-510
    • /
    • 2020
  • 콘크리트는 원자력 시설의 차폐용 구조물로 광범위하게 사용되고 있는 재료이다. 하지만, 시설의 해체 시 양적으로 가장 많이 발생하는 방사성 폐기물이기도하다. 콘크리트는 중성자를 포획하여 다양한 방사성 핵종을 생성하기 때문에 해체 전에 시료를 채취하여 방사능 측정 및 평가를 수행해야 한다. 측정은 주로 HPGe 검출기를 이용하는데 시료의 정확한 방사능 판정을 위해는 기하학적 보정인자, 자가흡수 보정인자, 계측기의 절대효율 등 효과적인 보정인자를 측정치에 반영해야 한다. 보정인자는 기하학적 및 화학적 상태가 실제 시료와 동일한 표준시료를 이용해서 동일한 측정조건 하에서 획득한다. 하지만, 콘크리트는 다양한 구성물질과 높은 밀도로 전처리가 제한적이므로 콘크리트 표준시료를 제작하는 것은 매우 어렵다. 또한 코어드릴(core drill)을 사용하여 채취되는 콘크리트 시료는 체적선원이므로 직경에 대한 기하학적 보정과 밀도에 대한 자가흡수에 대한 보정이 필수적이다. 따라서, 최근에는 많은 연구자들이 표준선원을 제작 후 측정하는 대신 몬테카를로 전산모사(Monte Carlo simulation)을 이용하여 효과적인 보정인자들을 계산하는 연구를 수행하고 있다. 본 연구에서는 Monte Carlo code 중 하나인 Geant4를 이용하여 방사화 콘크리트에서 가장 많이 생성되는 핵종인 152Eu, 60Co에서 방출되는 감마선 에너지에 대한 콘크리트 코어시료의 직경과 밀도에 따른 보정인자를 산출하였다.