• Title/Summary/Keyword: Detector materials

Search Result 503, Processing Time 0.019 seconds

Radiation Measurements at Fukushima Medical University over a Period of 12 Years Following the Nuclear Power Plant Accident

  • Ryo Ozawa
    • Journal of Radiation Protection and Research
    • /
    • v.48 no.3
    • /
    • pp.153-161
    • /
    • 2023
  • Background: Fukushima Medical University (FMU) is located 57 km northwest of the Fukushima Daiichi Nuclear Power Plant. Our laboratory has been conducting environmental radiation measurements continuously before and after the nuclear accident. We aimed to report the observed behavior of radiation originating from the released radioactive materials due to the accident, predict future trends, and disseminate the results to the local residents. Materials and Methods: Measurements of the counting rate by a diameter of 76 mm and a length of 76 mm thallium-doped sodium iodide (NaI[Tl]) scintillation detector (S-1211-T; Teledyne Brown Engineering Environmental Services) in the central part of the laboratory, and the dose rate outward at the window by NaI(Tl) scintillation detector and digital processor (EMF211; EMF Japan Co. Ltd.) were conducted. Results and Discussion: Measurements by Teledyne S-1211-T showed that in the early stages, radiation from radioactive isotopes with short half-lives was dominant, while radiation from radioactive isotopes with longer half-lives became dominant as the measurement period became longer. Through nonlinear least squares regression, both short and long half-lives were successfully determined. It was also possible to predict how the radiation dose would decrease. The environmental radiation trends around FMU were measured by the EMF211. Both measurements were affected by rainfall and snow accumulation. Decontamination work on the FMU campus impacted measurements by the EMF211 especially. Conclusion: The results of two types of measurements, one at the center and the other at the window side of the laboratory, were presented. By applying a simplified model, radiation from radioactive isotopes with short and long half-lives was identified. Based on these results, future trends were predicted, and the information was used for public communication with the local residents.

HACCP in Changran Jeotgal

  • Park Mi-Yeon;Choi Seung-Tae;Chang Dong-Suck
    • Fisheries and Aquatic Sciences
    • /
    • v.5 no.1
    • /
    • pp.48-53
    • /
    • 2002
  • The HACCP (hazard analysis critical control point) concept becomes an important aspect of Good Manufacturing Practices (GMP) in safe food production. The HACCP plan was developed with food safety objective. The authors already carried out hazards analysis on Changran Jeotgal manufacturing process in a previous report. In this study we developed a HACCP plan on the manufacturing process of Changran Jeotgal. We could decide two CCPs those were salt concentration and eliminations of foreign materials before packaging. Foreign materials should be certainly checked out with laser detector just before packaging. Salt should be maintained more than $8\%$ to inhibit pathogenic bacteria in end product. On the Jeotgal process free water is removed after salting and Jeotgal is seasoned with several subsidiary materials such as com syrup. In result end products have $8\%$ salt with water activity 0.82. Most bacteria are inhibited but some can live in this condition. Materials on the working may be contaminate by pathogens, chemicals or physical hazards. It will be decreased by SSOP (standard sanitary operating program). The SSOP needed in Jeotgal plants is nearly same as other general food manufacturing plants but essential to fulfill HACCP program.

Effects of cyclic mean pressure of helium gas on performance of integral crank driven stirling cryocooler

  • Hong, Yong-Ju;Ko, Junseok;Kim, Hyo-Bong;Park, Seong-Je
    • Progress in Superconductivity and Cryogenics
    • /
    • v.18 no.3
    • /
    • pp.30-34
    • /
    • 2016
  • An integral crank driven Stirling cryocooler is solidly based on concepts of direct IR detector mounting on the cryocooler's cold finger, and the integral construction of the cryocooler and Dewar envelope. Performance factors of the cryocooler depend on operating conditions of the cryocooler such as a cyclic mean pressure of the working fluid, a rotational speed of driving mechanism, a thermal environment, a targeted operation temperature and etc.. At given charging condition of helium gas, the cyclic mean pressure of helium gas in the cryocooler changes with temperatures of the cold end and the environment. In this study, effects of the cyclic mean pressure of helium gas on performances of the Stirling cryocooler were investigated by numerical analyses using the Sage software. The simulation model takes into account thermodynamic losses due to an inefficiency of regenerator, a pressure drop, a shuttle heat transfer and solid conductions. Simulations are performed for the performance variation according to the cyclic mean pressure induced by the temperature of the cold end and the environment. This paper presents P-V works in the compression and expansion space, cooling capacity, contribution of losses in the expansion space.

Effect of Black Charcoal and Activated Carbon for Reduction of Radon Radioactivity that Emitted from Building Materials (건축재료로부터 방출되는 라돈방사능 감소를 위한 흑탄과 활성탄 효과)

  • Cho, Yun-Min;Lee, Hwa-Hyung
    • Journal of the Korea Furniture Society
    • /
    • v.22 no.1
    • /
    • pp.13-17
    • /
    • 2011
  • Recently, interest in indoor air quality is increasing. Especially, radon radioactivity among the indoor air is a well-known risk factor for lung cancer because of ionizing radiation in the form of ${\alpha}$-particles. This study was carried out to investigate effect of black charcoal and activated carbon for reduction of radon radiation that emitted from building materials. Black charcoal and activated carbon were used as a barrier which was against the infiltration of radon. The source of radon was gypsum board. Two types of charcoal barrier were powder- and board-type with 5 mm, 10 mm thickness respectively. The method for this determination is evaluated radon concentration in chamber. The measurements were performed with radon detector, SARAD3120. Results of this study are as following: Black charcoal and activated carbon confirmed the highly efficient barrier. Radon concentration was reduced from 72% to 85% as compared the control chamber. Radon reduction capability, however, was no difference as barrier's types. Results obtained in ventilation condition, radon concentration shows 5.93 pCi/L on average in the closed condition and shows 2.69 pCi/L in the opened condition.

  • PDF

카바졸 전자 공여기를 포함한 D-${\pi}$-A 유도체의 결정 구조

  • Kim, Byung-Soon;Kim, Su-Ho;Matsumoto, Shinya;Son, Young-A
    • Proceedings of the Korean Society of Dyers and Finishers Conference
    • /
    • 2011.03a
    • /
    • pp.63-63
    • /
    • 2011
  • The donor-${\pi}$-acceptor (D-${\pi}$-A) chromophoric dye system has received great attention in variety fields such as electroluminescent materials, sensors and optoelectronic devices. There are many research activities focused on the development for abovementioned application materials with the high-performance properties. In the previous work, we are reported that novel D-${\pi}$-A dye, 2-[4-(9H-carbazol-9-yl)benzylidene]-2,3-dihydroinden-1-one, is successfully attained and exhibited a positive fluorescence solvatochromism. In this work, the molecular structure and packing geometry of 2-[4-(9H-carbazol-9-yl)benzylidene]-2,3-dihydroinden-1-one was discussed by their conformational structure. Their single yellow prism crystal having approximate dimensions of $0.30{\times}0.10{\times}0.10$ mm was carried out with a Rigaku RAXIS RAPID imaging plate area detector with graphite monochromated $CuK_{\alpha}$ radiation. Their crystal structure were solved by using the CrystalStructure crystallographic software package.

  • PDF

Structural and Electrical Properties of CoxMn3-xO4 Ceramics for Negative Temperature Coefficient Thermistors

  • Kim, Kyeong-Min;Lee, Sung-Gap;Kwon, Min-Su
    • Transactions on Electrical and Electronic Materials
    • /
    • v.18 no.6
    • /
    • pp.330-333
    • /
    • 2017
  • $Co_xMn_{3-x}O_4$ ($1.48{\leq}x{\leq}1.63$) ceramics were fabricated using the solid-state reaction method. Structural and electrical properties of specimens based on the composition ratio of Co were observed in order to investigate their applicability in NTC thermistors. All specimens showed a single spinel phase with a homogeneous tetragonal structure. The $Co_{1.57}Mn_{1.43}O_4$ specimen showed a maximum average grain size of approximately $6.47{\mu}m$. In all specimens, TCR properties displayed excellent characteristics of over $-4.2%/^{\circ}C$. The resistivity at 298 K and B-value of the $Co_{1.57}Mn_{1.43}O_4$ specimen were approximately $418{\Omega}-cm$ and 4300, respectively.

Effect of Hg-ambient annealing on Hg0.7Cd0.3Te thin films for IR detector (Hg 분위기 열처리에 따른 적외선 감지용 Hg0.7Cd0.3Te 박막의구조적 특성 변화)

  • Kim, Kwang-Chon;Lee, Cha-Hyun;Choi, Won-Chel;Kim, Hyun-Jae;Kim, Jin-Sang
    • Journal of Sensor Science and Technology
    • /
    • v.19 no.5
    • /
    • pp.398-402
    • /
    • 2010
  • The liquid phase epitaxy(LPE) method was widely used to growth of mercury cadmium telluride(MCT) thin films. However, this method lead to Hg-vacancies in MCT thin film, because Hg has high vapor pressure at this temperature range. This is a well known defect in HgCdTe grown by LPE method. In this study, we report the development of techniques for improving the crystalline quality and controlling the composite uniformity of HgCdTe thin films using high- pressure Hg-ambient annealing method. As a result, we achieved the improvement of the composite uniformity of HgCdTe thin films. It was observed by the high angle annular dark field scanning TEM(HAADF-STEM) analysis. Moreover, new HgTe phase and a shrinking of lattice fringe were observed.

Electrical Properties of ZnxMn3-xO4 Ceramics for Application as IR Detectors

  • Kim, Kyeong-Min;Lee, Sung-Gap;Lee, Dong-Jin
    • Transactions on Electrical and Electronic Materials
    • /
    • v.17 no.4
    • /
    • pp.227-230
    • /
    • 2016
  • ZnxMn3-xO4 (0.95≤x≤1.20) specimens were prepared using a conventional solid state reaction method. All specimens were sintered in air at 1,200℃ for 12 h, cooled at a rate of 2℃/min to 800℃, and subsequently quenched to room temperature. We investigated the electrical properties of ZnxMn3-xO4 specimens with various amounts of ZnO for use as IR detectors. At a composition of x≥1.15, the ZnO phase precipitates beside the spinel structure. The electrical resistivity at room temperature, activation energy, responsivity, and detectivity of a Zn1.10Mn1.90O4 specimen are 653.2 kΩ-cm, 0.392 eV, 0.016 V/W, and 7.52×103 cmHz1/2/W, respectively.

Development of a DDA+PGA-combined non-destructive active interrogation system in "Active-N"

  • Kazuyoshi Furutaka;Akira Ohzu;Yosuke Toh
    • Nuclear Engineering and Technology
    • /
    • v.55 no.11
    • /
    • pp.4002-4018
    • /
    • 2023
  • An integrated neutron interrogation system has been developed for non-destructive assay of highly-radioactive special nuclear materials, to accumulate knowledge of the method through developing and using it. The system combines a differential die-away (DDA) measurement system for the quantification of nuclear materials and a prompt gamma-ray analysis (PGA) system for the detection of neutron poisons which disturb the DDA measurements; a common D-T neutron generator is used. A special care has been taken for the selection of materials to reduce the background gamma rays produced by the interrogation neutrons. A series of measurements were performed to test the basic performance of the system. The results show that the DDA system can quantify plutonium of as small as 20 mg and it is not affected by intense neutron background up to 1.57 × 107 s-1 and gamma ray of 4.43 × 1010 s-1. The gamma-ray background counting rate at the PGA detector was reduced down to 3.9 × 103 s-1 even with the use of the D-T neutron generator. The test measurements show that the PGA system is capable of detecting 0.783 g of boron and about 86.8 g of gadolinium in 30 min.

Feasibility study of a novel hash algorithm-based neutron activation analysis system for arms control treaty verification

  • Xiao-Suo He;Yao-Dong Dai;Xiao-Tao He;Qing-Hua He
    • Nuclear Engineering and Technology
    • /
    • v.56 no.4
    • /
    • pp.1330-1338
    • /
    • 2024
  • Information on isotopic composition and geometric structure is necessary for identifying a true warhead. Nevertheless, such classified information should be protected physically or electronically. With a novel Hash encryption algorithm, this paper presents a Monte Carlo-based design of a neutron activation analysis verification module. The verification module employs a thermal neutron source, a non-uniform mask (physically encrypting information about isotopic composition and geometric structure), a gamma detector array, and a Hash encryption algorithm (for electronic encryption). In the physical field, a non-uniform mask is designed to distort the characteristic gamma rays emitted by the inspected item. Furthermore, as part of the Hash algorithm, a key is introduced to encrypt the data and improve the system resolution through electronic design. In order to quantify the difference between items, Hamming distance is used, which allows data encryption and analysis simultaneously. Simulated inspections of simple objects are used to quantify system performance. It is demonstrated that the method retains superior resolution even with 1% noise level. And the performances of anti-statistical attack and anti-brute force cracking are evaluated and found to be very excellent. The verification method lays a solid foundation for nuclear disarmament verification in the upcoming era.