• Title/Summary/Keyword: Detector

Search Result 6,182, Processing Time 0.03 seconds

A Design of the RF Signal Detector for Mobile Communication (이동통신용 RF 신호 검파기 설계)

  • An Jeong-Sig;Kim Kye-Kook
    • Journal of the Korea Society of Computer and Information
    • /
    • v.9 no.4 s.32
    • /
    • pp.185-189
    • /
    • 2004
  • In this paper, designed a diode detector and a log chip detector for mobile communication, and its application is proposed by compared results. In practice, fabricated a diode detector have showed detection voltage of $0{\sim}0.7V$ to RF input power of $-40dBm{\sim}-10dBm$, therefore it has suitable characteristic for small variable signal detection. And a log chip detector have showed wide dynamic range of 65dB, and $1.5{\sim}4.5V$ detection voltage to RF input power of $-65dBm{\sim}0dBm$. therefore we have found that it suit peak power measurement because it had insensible output detection voltage.

  • PDF

Joint Adaptive Combining and Variable Tap-Length Multiuser Detector for Underwater Acoustic Cooperative Communication

  • Liu, Zhiyong;Wang, Yinghua;Song, Lizhong;Wang, Yinyin;Dai, Fusheng
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.12 no.1
    • /
    • pp.325-339
    • /
    • 2018
  • In this paper, we propose a joint adaptive combining and variable tap-length multiuser detector (MUD) for amplify-and-forward (AF) underwater acoustic cooperative interleave-division multiple access (IDMA) communication system. The proposed MUD jointly realizes tap-length adjustment, adaptive combining, and multiuser detection. In contrast to the existing methods, the proposed detector can adaptively combine the received signals from different nodes at destination, and does not need the assumption that full and perfect channel state information (CSI) of all the links at the receiver is known. Moreover, the proposed detector can adaptively adjust the tap coefficient vector and tap-length of each branch according to the specific channel profile of each branch. Simulation results validate the feasibility and show the advantages of the proposed detector against existing counterparts.

The Use of the Online Two-dimensional Liquid Chromatography Coupled with a Universal Detector for the Screening of Non-volatile Potential Migrants in Food Packaging Materials (식품포장재내 비휘발성 잠재 이행물질들의 스크리닝을 위한 이차원크로마토 그래피와 범용검출기의 이용)

  • Yoon, Chan-Suk;Lee, Keun-Taik
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.16 no.1
    • /
    • pp.9-18
    • /
    • 2010
  • For screening test of the non-volatile compounds which migrate from food packaging materials into foodstuffs, the traditional high performance liquid chromatography (HPLC) systems suffer from the lack of universal detector with high sensitivity and universality and high efficiency HPLC separation column which provides complete separation of complex mixtures into all individual substances. In this work, the use possibility of online two-dimensional liquid chromatography (2D-LC) system coupled with a charged aerosol detector (CAD), a universal detector, was reviewed. 2D-LC system permits to improve peak capacity and resolving power for complex mixtures. Charged aerosol detector (CAD) offers a new feasibility for detection of any non-volatile compounds with high sensitivity and constant response factor in a calibration range. The combination of size exclusion chromatography (SEC) and normal phase HPLC (NP-HPLC) is most frequently used for the separation of the natural and synthetic polymers which are mainly used as raw materials for the manufacture of food packaging materials. However, there is no commercial software available for data acquisition and handling and therefore the quantification in 2D-LC analysis is still rare.

  • PDF

Development of Leakage Detector for Electric Equipment Failure in Fountain (분수대에서의 전기설비 고장에 대한 누전 감지 장치 개발)

  • Kim, Doo-Hyun;Kim, Sung-Chul;Park, Jong-Young
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.1
    • /
    • pp.35-40
    • /
    • 2018
  • This research aimed to develop an leakage detector of analyzing the electric potential generated from the electric leakage of electric equipment of the fountain. To accomplish this goal, the potential gradient was analyzed against path 1 ~ path 4; this was done by taking the lighting of a fountain as the electric leakage point based on code analyses in Korea and other countries. Lighting 1 was taken as the electric leakage point, and the earthing point was set against lightings(2~3). It appeared that the allowable touch voltage against the 1 type(under 2.5 V) exceeded 60.0%. Therefore, the lighting of fountain turned out to be the most dangerous point, and electric shock could be formed by the electric leakage of electric equipment in underwater as well as by the lighting. An leakage detector was developed based on this risk; this detector is capable of analyzing the electric potential of a electric equipments of the fountain in underwater. Then, a verification test was carried out. This leakage detector can be used to measure electric potential in various submerged areas such as swimming pools, flooded spaces, and fountains.

Partial IC Blind Multiuser Detection for CDMA Systems (CDMA 시스템을 위한 부분 간섭 제거 블라인드 다중 사용자 검출)

  • Woo Dae-Ho;Yoo Young-Gyo;Byun Youn-Shik
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.31 no.2C
    • /
    • pp.184-190
    • /
    • 2006
  • In this paper, we propose the blind multiuser detector which is robust against the effects of near-far and multiuser interference. The proposed detector is composed of the partial IC(interference canceller) and the blind MOE(minimum output energy) multiuser detector. The partial IC partially eliminates interference components from the received signal then the output of partial IC is fed into the input of multiuser detector. Simulation results show that the proposed detector has the robust property but the performance of conventional MOE multiuser detector is rapidly degraded in case of existing both near far and multiuser. Thus, the proposed partial IC BMUD(blind multiuser detection) technique has better performance than the conventional MOE.

Efficacy of the AHI Mastitis Detector for the Diagnosis of Bovine Mastitis (전도율측정법(傳導率測定法)(AHI Mastitis Detector)을 이용(利用)한 유방염진단(乳房炎診斷)의 야외적용시험(野外適用試驗))

  • Park, Yong-Ho;Kim, Keum-Hwa;An, Soo-Hwan;Kim, Dong-Sung
    • Korean Journal of Veterinary Research
    • /
    • v.22 no.2
    • /
    • pp.273-278
    • /
    • 1982
  • A total of 136 dairy cows were subjected to test for bovine mastitis by AHI mastitis detector, microbiological test (MT) and California mastitis test (CMT). The results obtained were summarlized as follows: MT indicated that the most important causative microorganisms isolated from mastitic milk were Staphylococcus aureus (59.3%), Staphylococcus epidermidis (16.4%), Streptococcus agalactiae (12.4%) and Streoticoccus uberis (4.4%). In Holstein breed, the critical threshold of electrical conductivity values of normal and mastitic milk were found to be less than $6,900{\mu}S$ and above, $7,700{\mu}S$, respectively. Although there was goad agreement (92.0%) between AHI mastitis detector test and CMT for the diagnosis of bovine mastitis, the diagnostic efficiency of AHI mastitis detector (80.0%) was higher than that of CMT (74.0%) when compared with microbiological findings. In addition, handiness and objectivity of AHI mastitis detector for the detection of mastitic milk suggested that this could effectively be used for the diagnosis of both clinical and subclinical bovine mastitis in field.

  • PDF

Introduction of Ultraviolet/Infrared Flame Detector and Method for False Detection Prevention (자외선/적외선 불꽃감지기 소개 및 오동작 방지를 위한 연구)

  • Lim, Byung-Hyun;Ko, Nak-Yong;Hwang, Jong-Sun;Kim, Yeong-Min;Kim, Jong-Man
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.05b
    • /
    • pp.8-11
    • /
    • 2003
  • We propose that when combustible burn with contain carbon, introduce fire detector with sensor of private-use detectable light energy as infrared and ultraviolet in energy of electromagnetic-wave type radiate from flame, method for correct discrimination to resemble fire produce false alarm of detector such as sun light, hot object radiation, are welding. This research using infrared sensor is pyroelectric infrared sensor based black body radiation theory. Ultraviolet sensor is uv Tron using gas multiplication effect to current discharge and photoelectric effect of metal. To have high sensibility and to gain proper output voltage, it has high responsive performance. This research introduced UV/IR compound type flame detector and proposed method of false alarm reduced to resemble fire. The result propres the prevention and extinction of fire technique degree, certificated operation of detector.

  • PDF

Experimental and Simulated Efficiency of a HPGe Detector in the Energy Range of $0.06{\sim}11$ MeV

  • Park Chang Su;Sun Gwang Min;Choi H.D.
    • Nuclear Engineering and Technology
    • /
    • v.35 no.3
    • /
    • pp.234-242
    • /
    • 2003
  • The full energy peak efficiency of a hyper pure germanium (HPGe) detector was calibrated in a wide energy range from 0.06 to 11 MeV. Both the experimental technique and the Monte Carlo method were used for the efficiency calibration. The measurement was performed using the standard radioisotopes in the low energy region of $60{\sim}1408$ keV, which was further extended up to 11 MeV by using the $^{14}N(n,r)\;and\;^{35}Cl(n,r)$ reactions. The GEANT Monte Carlo code was used for efficiency calculation. The calculated efficiency had the same dependency on the r-ray energy with the measurement, and the discrepancy between the calculation and the measurement was minimized by fine-tuning of the detector geometry. From the calculated result, the efficiency curve of the HPGe detector was reliably determined particularly in the high energy region above several MeV, where the number of measured efficiency points is relatively small despite the wide energy region. The calculated efficiency agreed with the measurement within about $7\%$. In addition to the efficiency calculation, the origin of the local minimum near 600 keV on the efficiency curve was analyzed as a general characteristics of a HPGe detector.

Analysis of the Response Time of a Photoelectric Spot-Type Smoke Detector Depending on the Type of Fires (화원에 따른 광전식 연기감지기 반응시간 분석)

  • Jee, Seung-Wook
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.5
    • /
    • pp.89-94
    • /
    • 2013
  • The fire testing performed for smoke detector model approval in Korea tests only one kind of fire smoke. A photoelectric spot-type smoke detector using Mie scattering is affected by the wavelength of light beam and the particle diameter. According to UL (Underwriters Laboratories Inc.) 268 standard, this paper analyze the characteristic of the response for a photoelectric spot-type smoke detector on sale in Korea using various fire smokes. Probability that the response time is included in non-defective range is 100% in paper fire, 90% in wood fire and 75% in flammable liquid fire, 90% in wood fire and 75% in flammable liquid fire. According to the estimation for population mean of the response time choosing a confidence level of 99%, a maximum of 19% for wood fire and that of 38% for flammable liquid fire are defective. As the result of analysis of smoke particle, this paper is found that these results are caused by the smoke particles are wide variations in size or have very black.

Low-Power Channel-Adaptive Reconfigurable 4×4 QRM-MLD MIMO Detector

  • Kurniawan, Iput Heri;Yoon, Ji-Hwan;Kim, Jong-Kook;Park, Jongsun
    • ETRI Journal
    • /
    • v.38 no.1
    • /
    • pp.100-111
    • /
    • 2016
  • This paper presents a low-complexity channel-adaptive reconfigurable $4{\times}4$ QR-decomposition and M-algorithm-based maximum likelihood detection (QRM-MLD) multiple-input and multiple-output (MIMO) detector. Two novel design approaches for low-power QRM-MLD hardware are proposed in this work. First, an approximate survivor metric (ASM) generation technique is presented to achieve considerable computational complexity reduction with minor BER degradation. A reconfigurable QRM-MLD MIMO detector (where the M-value represents the number of survival branches in a stage) for dynamically adapting to time-varying channels is also proposed in this work. The proposed reconfigurable QRM-MLD MIMO detector is implemented using a Samsung 65 nm CMOS process. The experimental results show that our ASM-based QRM-MLD MIMO detector shows a maximum throughput of 288 Mbps with a normalized power efficiency of 10.18 Mbps/mW in the case of $4{\times}4$ MIMO with 64-QAM. Under time-varying channel conditions, the proposed reconfigurable MIMO detector also achieves average power savings of up to 35% while maintaining a required BER performance.