• 제목/요약/키워드: Detector

검색결과 6,190건 처리시간 0.03초

Multiuser Detection for Multicarrier DS/CDMA System

  • Park, Wan;Kim, Jin-Young
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2000년도 하계종합학술대회 논문집(1)
    • /
    • pp.201-204
    • /
    • 2000
  • In this paper, a new multiuser detector combining multicarrier and decorrelating detection schemes is proposed and analyzed in a frequency selective Rayleigh fading channel. The bit error probability is derived and compared with that of the conventional decorrelating detector. From the numerical results, it is shown that the proposed detector achieves better BER performance and lower computational complexity than those of the conventional decorrelating detector.

  • PDF

간단한 구조의 폴딩 EPR4 비터비 검출기 (A Reduced Complexity Folding EPR4 Viterbi Detector)

  • 이천수;기훈재김수원
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1998년도 추계종합학술대회 논문집
    • /
    • pp.687-690
    • /
    • 1998
  • The full Viterbi detector for EPRML read channel system needs large area due to complex computation. There are several conventional methods to reduce the complexity such as GVA(Generalized Viterbi Algorithm) and BMS(Branch Metric Shift). This paper proposes another method, FVD(Folding Viterbi Detector), that has state transition diagram folded with inverted states. Compared with GVA detector, FVD requires only 61% gates and has lower power consumption and better BER performance.

  • PDF

고속 무선 LAN 시스템을 위한 저복잡도 MIMO-OFDM 심볼 검출기 설계 (Design of Low-Complexity MIMO-OFDM Symbol Detector for High Speed WLAN Systems)

  • 임준하;김재석
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2008년도 하계종합학술대회
    • /
    • pp.447-448
    • /
    • 2008
  • This paper presents a low-complexity design and implementation results of a multi-input multi-output (MIMO) orthogonal frequency division multiplexing (OFDM) symbol detector for high speed wireless LAN (WLAN) systems. The proposed spatial division multiplexing (SDM) symbol detector is designed by HDL and synthesized to gate-level circuits using 0.18um CMOS library. The total gate count for the symbol detector is 238K.

  • PDF

Li drifted Ge 검출기에 관해서 (For the Li Drifted Germanium Detector)

  • 함창식
    • 대한전자공학회논문지
    • /
    • 제4권2호
    • /
    • pp.16-21
    • /
    • 1967
  • 이 보고는 처음에 Li drifted Ge 검출기에 관해서 이 Li drifted Ge 검출기에 의한 열중성자로부터의 Cl(n, r) 반응에서 생기는 r선 스텍트로를 보여준다. 이 Li drifted Ge 검출기의 에너지 분해능은 의 122KeV에서 4.5KeV, 의 1333KeV에서 10KeV이다.

  • PDF

중.원 적외선 동시 검출기를 위한 readout 회로 설계 (Readout Circuit Design for Dual Band IR Detector)

  • 강상구;김병혁;이희철
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2001년도 하계종합학술대회 논문집(2)
    • /
    • pp.57-60
    • /
    • 2001
  • A readout circuit for Dual band IR detector was proposed and designed. Designed circuit provide to detector a stable diode bias and high injection efficiency using Buffered Direct Injection (BDI) input circuit. Then, amplifier in the unit cell is operated when cell is selected in order to minimize the power consumption. We could confirm through the simulation that designed circuit integrate and output simultaneously the signal generating from the dual band IR detector.

  • PDF

Linear-Quadratic Detectors for Spectrum Sensing

  • Biglieri, Ezio;Lops, Marco
    • Journal of Communications and Networks
    • /
    • 제16권5호
    • /
    • pp.485-492
    • /
    • 2014
  • Spectrum sensing for cognitive-radio applications may use a matched-filter detector (in the presence of full knowledge of the signal that may be transmitted by the primary user) or an energy detector (when that knowledge is missing). An intermediate situation occurs when the primary signal is imperfectly known, in which case we advocate the use of a linear-quadratic detector. We show how this detector can be designed by maximizing its deflection, and, using moment-bound theory, we examine its robustness to the variations of the actual probability distribution of the inaccurately known primary signal.

Signal Shapes from a Closed-ended Coaxial HPGe Detector

  • Park, H. D.
    • Nuclear Engineering and Technology
    • /
    • 제29권6호
    • /
    • pp.451-458
    • /
    • 1997
  • Signal shapes from a closed-ended coaxial HPGe detector are investigated by numerical methods. The detector used in this study has a volume of 72 ㎤ with relative efficiency of 15%. The electric field and potential distributions in the detector are determined by solving the Poisson equation at the depletion and operating bias. Hence the time dependent signal shapes induced on the electrode are obtained from the energy balance consideration and tv solving the equation of motion for the charge carriers. For various initial positions of a charge carrier pair, the collection times of induced charge vary in the range of 70 - 404 nsec.

  • PDF

직접검파, 광통신에 이용되는 Point-detector Array의 해석 (Direct-Detection, Analysis of the point-detector arrays used in optical communication)

  • 성평식;김영권
    • 한국통신학회논문지
    • /
    • 제12권5호
    • /
    • pp.428-438
    • /
    • 1987
  • 本 論文은 大氣 空間에서 信號場과 雜音場을 處理하기 위하여 point-detector array檢波 시스템을 構成한 것이다. 또 variance 및 covariance Circuit도 구성했다. 이것들을 이용하여 測定한 直接檢波 最大出力은 理論値와 잘 一致함을 確認하였고 또한 實驗値는 joint-Gaussian理論曲線과 一致하였다.

  • PDF

Multi-Detector Row CT를 이용한 중심부 기도 질환의 평가 (Multi-Detector Row CT of the Central Airway Disease)

  • 강은영
    • Tuberculosis and Respiratory Diseases
    • /
    • 제55권3호
    • /
    • pp.239-249
    • /
    • 2003
  • Multi-detector row CT (MDCT) provides faster speed, longer coverage in conjunction with thin slices, improved spatial resolution, and ability to produce high quality muliplanar and three-dimensional (3D) images. MDCT has revolutionized the non-invasive evaluation of the central airways. Simultaneous display of axial, multiplanar, and 3D images raises precision and accuracy of the radiologic diagnosis of central airway disease. This article introduces central airway imaging with MDCT emphasizing on the emerging role of multiplanar and 3D reconstruction.

6MV X-선 검출특성 조사를 위하여 유전체 필름을 이용하여 제작한 평행판 검출기의 유용성 (Feasibility Study of Parallel- Plate Detector Using Dielectric film for 6 MV X-ray)

  • 조문준;김용은;이병용;김정기;임상욱;김현수;김기환
    • 한국의학물리학회지:의학물리
    • /
    • 제15권2호
    • /
    • pp.105-111
    • /
    • 2004
  • 본 연구에서는 의료용 선형가속기로부터 발생되는 명목상 가속전압 6 MV선의 검출특성을 확인하기 위하여 유전체 물질을 사용한 평행판 검출기를 제작하였다. 제작한 검출기의 전극은 단면이 크롬으로 코팅되어 있는 FEP유전체 필름(두께: 100 $\mu\textrm{m}$)을 사용하였고 두 전극 사이에 PTFE유전체 필름(두께 : 100 $\mu\textrm{m}$)을 삽입하였다. 측정을 위하여 선원-팬텀 표면간의 거리 100 cm, 그리고 팬텀의 표면으로부터 깊이 5 cm되는 지점에 방사선 유도전하를 획득하기 위한 제작검출기를 놓았다. 방사선 조사시 제작검출기의 유용성을 알아보기 위하여, 영점 변동, 누설 전류, 인가전압에 따른 검출기의 반응, 재현성, 선형성, 조직최대선량비 등을 측정하였다. 측정결과 검출기의 영점 변동 전류 (I$_{Z}$ )는 8.3 pA, 누설 전류(I$_{I}$)는 10 pA 이었다. 제작 검출기는 인가전압에 대한 선형성을 보였으며, 또한 재현성실험에서는 조사된 선량에 대하여 1% 오차 범위 내에서 일치하였다. 검출기의 선량에 대한 선형성은 3% 이내의 오차범위에서 일치하면서 선량율 의존성이 있음을 확인하였다. 조직최대선량비분포에 대한 제작 평행판 검출기와 비교검출기간의 선량오차는 팬텀내의 최대 선량점으로부터 7.5 cm까지 3% 이내에서 일치하였다. 본 연구결과 유전체 필름을 이용한 평행판 검출기는 선량계로서의 기본적인 특성들을 허용 가능한 범위에서 만족스러워 상대선량측정을 위한 검출기로 사용할 수 있음을 확인할 수 있었다.

  • PDF