• Title/Summary/Keyword: Detection techniques

Search Result 2,614, Processing Time 0.045 seconds

Augmented Reality System using Planar Natural Feature Detection and Its Tracking (동일 평면상의 자연 특징점 검출 및 추적을 이용한 증강현실 시스템)

  • Lee, A-Hyun;Lee, Jae-Young;Lee, Seok-Han;Choi, Jong-Soo
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.48 no.4
    • /
    • pp.49-58
    • /
    • 2011
  • Typically, vision-based AR systems operate on the basis of prior knowledge of the environment such as a square marker. The traditional marker-based AR system has a limitation that the marker has to be located in the sensing range. Therefore, there have been considerable research efforts for the techniques known as real-time camera tracking, in which the system attempts to add unknown 3D features to its feature map, and these then provide registration even when the reference map is out of the sensing range. In this paper, we describe a real-time camera tracking framework specifically designed to track a monocular camera in a desktop workspace. Basic idea of the proposed scheme is that a real-time camera tracking is achieved on the basis of a plane tracking algorithm. Also we suggest a method for re-detecting features to maintain registration of virtual objects. The proposed method can cope with the problem that the features cannot be tracked, when they go out of the sensing range. The main advantage of the proposed system are not only low computational cost but also convenient. It can be applicable to an augmented reality system for mobile computing environment.

Detection Methods of Histochemically-reactive Zinc in the CNS at the Light Microscopical Level (중추신경계통 내 분포하는 zinc 이온의 조직화학적 동정법 비교: I. 광학현미경수준에서)

  • Kim, Yi-Suk;Kim, Sang-Hyun;Lee, Beob-Yi;Lee, Hyun-Sook;Kim, Sung-Joo;Jo, Seung-Mook
    • Applied Microscopy
    • /
    • v.38 no.1
    • /
    • pp.29-34
    • /
    • 2008
  • Small amounts of zinc ions regulate a plentitude of enzymatic proteins, receptors and transcription factors, thus cells need accurate homeostasis of zinc ions. Some neurons have developed mechanisms to accumulate zinc in specific membrane compartment ("vesicular zinc"), which can be evidenced using histochemical techniques. These neurons are the socalled zinc enriched (ZEN) neurons, which accumulate glutamate and zinc inside their synaptic vesicles and release it during synaptic transmission. In the present paper we have studied the distribution of the ZEN terminals in the rat hippo-campus using ZnSe autometallography, Neo-Timm staining, ZnT3 immunohistochemistry and TSQ fluorescence staining.

Studies on the Immunoblot Characterization of Clonorchis sinensis Worm Antigens at Carly Development Stages (Immunoblot 법을 이용한 간흡충항원(肝吸蟲抗原)의 발육단계별(發育段階別) 항원성분석(抗原性分析)에 관한 연구(硏究))

  • Lee, Seon-Kyung;Joo, Kyoung-Hwan;Chung, Myung-Sook;Rim, Han-Jong
    • Journal of agricultural medicine and community health
    • /
    • v.16 no.1
    • /
    • pp.61-69
    • /
    • 1991
  • Serodiagnosis of Clonorchis sinensis infections will probably be a first choice tool for screening of clonorchiasis in a future because of increasing difficulties in collection and examination of stools. The sensitive test such as ELISA can he used effectively. However there are some limitations in serological diagnosis for the detection of serum antibody. One of the major problems is the non-specificity of the antigens which produce cross reaction with other helminthic infection sera. To solve this problem. many investigators have tried to purify the antigens used. In this study, we determined the antigenic profile of the crude saline extract antigen of C. sinensis at early developmental stage based on SDS-PAGE and immunoblotting techniques for the purpose of understanding the nature of C. sinensis worm antigen The following results were obtained : 1) The SDS-PAGE showed many protein hands ranging from 10Kd to 91Kd relative molecular weight. Among them, 66, 46, 40, 33, 27, 24, 16, 14 and 10Kd bands were observed as a principle bands. The protein components of C. sinensis changed chronologically during their early developmental period. 44Kd band was stained unclearly in antigen of 2 weeks worm, but changed to concentrated state in antigen of 5 weeks worm. 35Kd band was found in antigen of 2 weeks worm, however this band was disappeared in antigen of 5 weeks worm. 22Kd band also lost its staining property gradually. 2) In spite of differences in antigenic profile, there was no differences in the data obtained by microplate ELISA using each antigen preparation. Absorbance value began to rise in between 2 to 3 weeks after infection. 3) By EITB. serum antibody recognized major protein bands with molecular weight of 91, 85, 63, 46, 40, 33, 24, 14 and 10Kd hand respectively. Among them 66, 33, 17 and 14Kd bands were observed as non-specific band because they reacted even in normal control sera. Generally, gradual increase of positive reactions were observed as the infection period of C. sinensis was prolonged. In other hand, the reaction of 10Kd hand did not occurred when 26th week sera was tested. 4) The positive reactions using antigens of 2 weeks worm, especially on 40 and 24Kd bands, were most strong and sharply demarcated compared to those of 3~5 weeks worm antigen.

  • PDF

Evaluation of Half Cell Potential Measurement in Cracked Concrete Exposed to Salt Spraying Test (염해에 노출된 균열부 콘크리트의 반전위 평가)

  • Kim, Ki-Bum;Park, Ki-Tae;Kwon, Seung-Jun
    • Journal of the Korea Concrete Institute
    • /
    • v.25 no.6
    • /
    • pp.621-630
    • /
    • 2013
  • Several techniques for steel corrosion detection are proposed and HCP (half cell potential) technique is widely adopted for field investigation. If concrete has cracks on surface, steel corrosion is rapidly accelerated due to additional intrusion of chloride and carbon dioxide ions. This study is for an evaluation of HCP in cracked concrete exposed chloride attack. For this work, RC (reinforced concrete) beams are prepared considering 3 w/c ratios (0.35, 0.55, and 0.70) and several cover depths (10~60 mm) and various crack widths of 0.0~1.0 mm are induced. For 35 days, SST (salt spraying test) is performed for corrosion acceleration, and HCP and corrosion length of rebar are evaluated. With increasing crack width, w/c ratios, and decreasing cover depth, HCP measurements increase. HCP evaluation technique is proposed considering the effects of w/c ratios, crack width, and cover depth. Furthermore anti-corrosive cover depths are obtained through Life365 program and the results are compared with those from this study. The results shows relatively big difference in cracked concrete, however provide similar anti-corrosive conditions in sound concrete.

A Study of $^{222}Rn\;and\;^{226}Ra$ Analysis in the Groundwater by LSC (액체섬광계수기에 의한 지하수중의 $^{222}Rn$$^{226}Ra$ 분석법 연구)

  • Woo, Hyung-Joo;Yoon, Yoon-Yeol;Cho, Soo-Young;Chun, Sang-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.20 no.4
    • /
    • pp.275-283
    • /
    • 1995
  • PERALS(Photon Electron Rejecting Alpha Liquid Scintillation) spectrometry coupled with solvent extraction method has been set up for the analysis of $^{222}Rn\;and\;^{226}Ra$ in the groundwater. This analytical method offers low background, better energy resolution and lower quenching problem than the other techniques. By the analysis of NIST SRM 4966 $^{226}Ra$ standard, the analytical accuracy and precision were found to be 3% and 1%, respectively, and the relative standard deviation of the recovery of Rn extraction between pH2 and pH10 was 7%. Detection limits of $^{222}Rn$ and $^{226}Ra$ for 10 hours counting were counted to be $0.42 pCi/{\iota}\;and\;0.016 pCi/{\iota}$, respectively. For the test analysis of $^{222}Rn\;and\;^{226}Ra$ in the graundwater, hot spring water samples of 17 regions were analyzed. The concentration of $^{222}Rn$ were in the range of $90{\sim}5200pCi/{\iota}$ and average value was $1470pCi/{\iota}\;^{226}Ra$ concentration showed a peak value of $97.9pCi/{\iota}$ in a Kangwon region, but the average value was $1.14pCi/{\iota}$ except that region.

  • PDF

PHA-Induced Peripheral Blood Cytogenetics and Molecular Anslysis : a Valid Diagnostic and Follow-up Modality For Acute Primyelocytic Leukemia Patients Treated With ATRA and/or Arsenic Tri-oxide

  • Baba, Shahid M;Azad, Niyaz A;Shah, Zaffar A;Afroze, Dil;Pandith, Arshad A;Jan, Aleem;Aziz, Sheikh A;Dar, Fayaz A
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.4
    • /
    • pp.1999-2006
    • /
    • 2016
  • Background: Acute promyelocytic leukemia (APML) is characterized by the reciprocal translocation t(15;17) (p22;p12) resulting in the PML-$RAR{\alpha}$ fusion gene. A dual diagnostic and follow up approach was applied including cytogenetic demonstration of the t(15;17) translocation and detection dg PML-$RAR{\alpha}$ chimeric transcripts by molecular means. Purpose: Conventional cytogenetics involving bone marrow is beset with high probability of poor metaphase index and was substituted with phytohemagglutinin (PHA)-induced peripheral blood culture based cytogenetic analysis as a diagnostic & follow up modality in APML patients of Kashmir (North India). Both qualitative (RT-PCR) and quantitative (Q-PCR) tests were simultaneously carried out to authenticte the modified cytogenetics. Materials and Method: Patient samples were subjected to the said techniques to establish their baseline as well as follow-up status. Results: Initial cytogenetics revealed 30 patients (81%) Positive for t(15;17) whereas 7 (19%) had either cryptic translocation or were negative for t(15;17). Two cases had chromosome 16q deletion and no hallmark translocation t(15;17). Q-PCR status for PML-$RAR{\alpha}$ was found to be positive for all patients. All the APML patients were reassessed at the end of consolidation phase and during maintenance phase of chemotherapy where 6 patients had molecular relapse, wherein 4 also demonstrated cytogenetic relapse. Conclusions: It was found that PHA-induced peripheral blood cytogenetics along with molecular analysis could prove a reliable modality in the diagnosis and assessment of follow up response of APML patients.

Study on Improvement in Reliability of Measurement and Analysis for Polycyclic Aromatic Hydrocarbons in the Atmosphere (대기 중 다환방향족탄화수소(PAHs)의 측정.분석 신뢰도 향상에 관한 고찰)

  • Lee, Min-Do;Lim, Yong-Jae;Lee, Sang-Uk;Kong, Boo-Joo;Lee, Sang-Deok;Han, Jin-Seok
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.23 no.5
    • /
    • pp.515-525
    • /
    • 2007
  • In this study, various techniques for measurement and analysis of PAHs in the ambient air were verified in order to select a more reliable method. Sampling and analysis of PAHs were done by the EPA TO-13a method. QA/QC of the measurement was conducted to minimize errors in sampling and analyzing processes. The linearity of calibration curve of the PAH standards was good ($R^2{\geq}0.99$). Audit accuracy was evaluated using 5 internal standards of PAHs ($Naphthalene-d_8,\;Acenaphthene-d_{10},\;Phenanthrene-d_{10},\;Chrysene-d_{12},\;Perylene-d_{12}$). Relative standard deviations of the internal standard of the PAHs were ranged from 6.22% for $acenaphthene-d_{10}$ to 8.11% for $chrysene-d_{12}$. To evaluate the surrogate recoveries, two field surrogate standards of PAHs ($fluoranthene-d_{10},\;benzo(a)pyrene-d_{12}$) and two extract surrogate standards of the PAHs ($fluorene-d_{10},\;pyrene-d_{12}$) were spiked into all samples before field sampling and sample extraction, respectively. Recoveries of field the surrogate standards ranged from $80.4{\pm}12.2%$ for $fluoranthene-d_{10}$ to $66.2{\pm}12.8%$ for $benzo(a)pyrene-d_{12}$. Extraction recoveries of the surrogate standards ranged from $70.4{\pm}10.2%$ for $fluorene-d_{10}$ to $77.6{\pm}10.8%$ for $pyrene-d_{10}$. The detection limit of benzo(a)pyrene among 16 PAHs standards for quantitation was 20 pg.

Feature Map Based Complete Coverage Algorithm for a Robotic Vacuum Cleaner (청소 로봇을 위한 특징점 맵 기반의 전 영역 청소 알고리즘)

  • Baek, Sang-Hoon;Lee, Tae-Kyeong;Oh, Se-Young;Ju, Kwang-Ro
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.20 no.1
    • /
    • pp.81-87
    • /
    • 2010
  • The coverage ability is one of essential techniques for the Robotic Vacuum Cleaner (RVC). Most of the RVCs rely on random or regular pattern movement to cover a target space due to the technical difficulties to implement localization and map and constraints of hardwares such as controller and sensors. In this paper, we consider two main issues which are low computational load and using sensors with very limited sensing capabilities. First, in our approach, computing procedures to build map and detect the RVC's position are minimized by simplifying data obtained from sensors. To reduce computational load, it needs simply presenting an environment with objects of various shapes. Another isuue mentioned above is regarded as one of the most important problems in our approach, because we consider that many RVCs use low-cost sensor systems such as an infrared sensor or ultrasonic sensor with limited capabilities in limited range, detection uncertainty, measurement noise, etc. Methods presented in this paper are able to apply to general RVCs equipped with these sensors. By both simulation and real experiment, we evaluate our method and verify that the proposed method guarantees a complete coverage.

Detection of Knowledge Structure of Korean Studies Using Document Co-citation Analysis: the Difference between Self-perception and Others' Perception (문헌동시인용 분석을 통한 한국학 지식구조 파악: 주체 인식과 타자 인식의 차이)

  • Kim, Hea-JIn
    • Journal of Korean Library and Information Science Society
    • /
    • v.51 no.1
    • /
    • pp.179-200
    • /
    • 2020
  • This study aims to detect the knowledge structure of Korean studies using document co-citation analysis and text mining techniques. This study divided Korean corpus into two perspectives: Self-perceived and others' perceived Korean studies. To this end, we collected 10,929 humanities and social literature containing the word Korea or Korean as a keyword in the SCOPUS database. As a result of analysis, a total of 20 subdomains were found in the knowledge structure of self-perception, and a total of 14 subdomains were found in the knowledge structure of otherts' perception. Differences in Korean Studies between two are: First, the sub-area of self-perceived Korean studies is subdivided into more diverse areas than the sub-area of other-perceived Korean studies. Second the major areas in self-perceived Korean studies are customers and services, industrialization, multiculturalism, mental health, tourism, Korean language, environment, and cities. Others' perceptions of Korean Studies are grouped into domestic and foreign situations of Korea, Korean pop culture, Koreans as US immigrants, and Korean language. Finally, the common areas of self-perception and others' perception were mental health, tourism, Korean language, North-Korean defectors, and juvenile delinquency.

Detection and Blocking Techniques of Security Vulnerability in Android Intents (안드로이드 인텐트의 보안 취약성 탐지 및 차단 기법)

  • Yoon, Chang-Pyo;Moon, Seok-jae;Hwang, Chi-Gon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2013.05a
    • /
    • pp.666-668
    • /
    • 2013
  • Recently, the kind and number of malicious code, which operates in Operation System of smart devices, are rapidly increasing along with the fast supplement of smart devices. Especially, smart devices based on Android OS have high potential of danger to expose to malicious code as it has an easy access to system authority. When using intent, the global message system provided from Android, inter approach between applications is available, and possible to access to created data by the device. Intent provides convenience to application development in the aspect of reusability of component however, it could be appointed as a risk element in security-wise. Therefore, if intent is used in malicious purpose, it is easy to lead the condition where is weak on security. That is, it is possible to control as accessing to resources which application is carrying to operate by receiving intents as making smart device uncontrollable or consuming system resources. Especially, in case of system authority is achieved, the risks such as smart device control or personal information exposure become bigger when misusing broadcast intent through malicious code. This paper proposes a corresponding method of security vulnerability of Android intent that monitors the appearance of intent with intent pattern inspection, detects and blocks unidentified pattern intent.

  • PDF