• Title/Summary/Keyword: Design of measurement system

Search Result 2,450, Processing Time 0.047 seconds

A Design and Implementation of Integrated Performance Measurement System for Internet Routers (인터넷 라우터 통합 성능측정 시스템의 설계 및 구현)

  • Yu, Ki-Sung;Kim, Jae-Hwan;Shin, Jae-Wook;Cho, Gi-Hwan;Chung, Jin-Wook
    • Journal of Internet Computing and Services
    • /
    • v.8 no.4
    • /
    • pp.31-40
    • /
    • 2007
  • This paper presents a design and implementation of integrated performance measurement system to effectively assess the performance of internet router devices. Firstly, we examine the internet standards to extract performance metrics and the performance related tools available in public, then suggest a functional relationship among them, System architecture, user interface and database are presented as a whole system design. Finally, based the design detail, the system implementation has been described.

  • PDF

Development of Automatic Measurement and Inspection System for ALC Block Using Camera (카메라를 이용한 ALC 블록의 치수계측 및 불량검사 자동화 시스템 개발)

  • 허경무;김성훈
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.9 no.6
    • /
    • pp.448-455
    • /
    • 2003
  • A system design technique of automatic thickness measurement and defect inspection system, which measures the thickness of the ALC(Autoclaved Lightweight Concrete) block and inspects the defect on a realtime basis is proposed. The image processing system was established with a CCD camera, an image grabber, and a personal computer without using assembled measurement equipment. The image obtained by this system was analyzed by a devised algorithm, specially designed for the enhanced measurement accuracy. For the realization of the proposed algorithm, the preprocessing method that can be applied to overcome uneven lighting environment, an enhanced edge decision method using 8 edge-pairs with irregular and rough surface, the unit length decision method in uneven condition with rocking objects, and the curvature calibration method of camera using a constructed grid are developed. The experimental results, show that the required measurement accuracy specification is sufficiently satisfied using our proposed method.

The Suitability of the Size Classification of Dress Shirts on the Market (시판 드레스셔츠의 치수 구분 적합성)

  • Han, Eun Joo;Kweon, Soo Ae;Choi, Jong Myoung;Song, Jae Min;Lim, Bo Youn
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.39 no.5
    • /
    • pp.695-702
    • /
    • 2015
  • This study provides basic data that are helpful to prepare a sizing system for dress shirts that improves the wearer's size fitness. The 16 different parts of the dress shirts were measured for 24 pieces of dress shirts with three kinds of size (95, 100 and 105) among the eight different brands on the market. The measurement sizes of the dress shirts analyzed the accuracy of the size information, size classification by size designation, and differences of size by brand. The results of the study were: 1. The size information of dress shirts differed from customer demand. 2. The size increments between size designations differed from each other even though measurement sizes of the dress shirts increased as the size designation increase. 3. Measurement sizes of the dress shirts were different between brands even for dress shirts of the same size designation. It is necessary that manufacturers secure an accurate and standardized sizing system and provide accurate information for the measurement sizes of dress shirts on an online shopping mall.

Application of Particle Swarm Optimization for Harmonic State Estimation (전력시스템 고조파 상태 추정에서 PSO 적용)

  • Wang, Y.P.;Jeong, J.W.;Kim, H.H.;An, B.C.
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.529-530
    • /
    • 2007
  • The design of a measurement system to perform Harmonic State Estimation(HSE) is a very complex problem. In particular, the number of available harmonic analysis measurement instruments is always limited. Therefore, a systematic procedure is needed to design the optimal placement of measurement points. This paper presents an optimal algorithm of HSE which is based on an optimal placement of measurement points using PSO. This PSO-HSE has been applied to power system for the validation of an optimal algorithm of HSE. The study results have indicated an economical and effective method for optimal placement of measurement points using PSO in the HSE.

  • PDF

Hierarchical Measurement System Design by System Partitioning (계통 분할에 의한 계층적 측정 시스템 설계)

  • 문영현;최상봉;박영문;추진부
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.37 no.5
    • /
    • pp.261-271
    • /
    • 1988
  • This paper presents a hierarchical algorithm of the measurement system design by system partitioning. With the increase of system size, the conventional algorithms of the optimal measurement system design confront the problems of excessive memory requirements, long computation time and cumulative computation errors. In order to overcome these problems, a hierarchical approach by system partitioning is proposed with the introduction of equivalent measurements for all the extemal measurements. This approach has the advantage of remarkable reduction in computation time and memory requirements, and guarantees sufficient calculation accuracy in its application to large power systems. The proposed algorithm has been tested for various systems, which shows its applicability to practical power systems.

Design of Screening Inspection Procedures Based on Guard Bands Considering Measurement Errors (측정오류를 고려한 가드밴드 기반 스크리닝 검사방식의 설계)

  • Kim, Young Jin
    • Journal of Korean Society for Quality Management
    • /
    • v.41 no.4
    • /
    • pp.673-681
    • /
    • 2013
  • Purpose: The purpose of this study is to investigate the design optimization modeling of screening procedures based on the assessment of misclassification errors. Methods: Misclassification errors due to measurement variability are derived for normally distributed quality characteristics. Further, an optimization model for ensuring the level of outgoing quality is proposed and demonstrated through an illustrative example. Results: It is shown that two types of misclassification errors (i.e., false acceptance and false rejection) may be properly compromised through an analytical assessment of measurement errors and an optimization modeling. It is also discussed that a variety of optimization modeling may be enabled based on the derivation of measurement errors. Conclusion: It may be concluded that the design of screening inspection may further be facilitated by including the effect of measurement errors on the performance of screening inspection procedure.

Design and Implementation of a DSP-Based Multi-Channel Power Measurement System

  • Jeon Jeong-Chay;Oh Hun
    • KIEE International Transactions on Power Engineering
    • /
    • v.5A no.3
    • /
    • pp.214-220
    • /
    • 2005
  • In order to improve energy efficiency and solve power disturbances, power components measurement for both the supply and demand side of a power system must be implemented before appropriate action on the power problems can be taken. This paper presents a DSP (Digital Signal Processor)-based multi-channel (voltage 8-channel and current 10-channel) power measurement system that can simultaneously measure and analyze power components for both supply and demand. Voltage 8-channel and current 10-channel measurement is made through voltage and current sensors connected to the developed system, and power components such as reactive power, power factor and harmonics are calculated and measured by the DSP. The measured data are stored in a personal computer (PC) and a commercial program is then used for measurement data analysis and display. After voltage and current measurement accuracy revision using YOKOGAWA 2558, the developed system was tested using a programmable ac power source. The test results showed the accuracy of the developed system to be about 0.3 percent. Also, a simultaneous measurement field test of the developed system was implemented by application to the supply and demand side of the three-phase power system.

Effect of Measurement Error on the Economic Design of Control Charts for Controlling Process Means (측정오차가 공정평균 관리도의 경제적 설계에 미치는 영향)

  • 염창선
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.22 no.50
    • /
    • pp.55-63
    • /
    • 1999
  • Past studies on economic control charts for controlling process means assumed that the measures of a quality characteristic do not have measurement error. In practice, however, this assumption is frequently violated. In this paper, the economic design models of three control charts(Xbar control chart, Xbar control chart with warning limits, and CUSUM control chart) for controlling process means are developed on the assumption that the measures can have measurement error. The effects of measurement error on the process control cost and design parameters of three economic control charts are examined. According to the experiments done in this study, when measurement error exists, the economic CUSUM control chart has lower process control cost in comparison with two other control charts. When measurement error becomes larger, both the sample size and the sampling interval increase while the control limits decrease.

  • PDF

Design of a MEMS sensor array for dam subsidence monitoring based on dual-sensor cooperative measurements

  • Tao, Tao;Yang, Jianfeng;Wei, Wei;Wozniak, Marcin;Scherer, Rafal;Damasevicius, Robertas
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.15 no.10
    • /
    • pp.3554-3570
    • /
    • 2021
  • With the rapid development of the Chinese water project, the safety monitoring of dams is urgently needed. Many drawbacks exist in dams, such as high monitoring costs, a limited equipment service life, long-term monitoring difficulties. MEMS sensors have the advantages of low cost, high precision, easy installation, and simplicity, so they have broad application prospects in engineering measurements. This paper designs intelligent monitoring based on the collaborative measurement of dual MEMS sensors. The system first determines the endpoint coordinates of the sensor array by the coordinate transformation relationship in the monitoring system and then obtains the dam settlement according to the endpoint coordinates. Next, this paper proposes a dual-MEMS sensor collaborative measurement algorithm that builds a mathematical model of the dual-sensor measurement. The monitoring system realizes mutual compensation between sensor measurement data by calculating the motion constraint matrix between the two sensors. Compared with the single-sensor measurement, the dual-sensor measurement algorithm is more accurate and can improve the reliability of long-term monitoring data. Finally, the experimental results show that the dam subsidence monitoring system proposed in this paper fully meets the engineering monitoring accuracy needs, and the dual-sensor collaborative measurement system is more stable than the single-sensor monitoring system.

Development of a Real-time 3D Intraoral Scanner Based on Fringe-Projection Technique (프린지 투영법을 이용한 실시간 3D 구강 내 스캐너의 개발)

  • Ullah, Furqan;Lee, Gunn-Soo;Park, Kang
    • Korean Journal of Computational Design and Engineering
    • /
    • v.17 no.3
    • /
    • pp.156-163
    • /
    • 2012
  • Real-time three-dimensional shape measurement is becoming increasingly important in various fields, including medical sciences, high-technology industry, and microscale measurements. However, there are not so many 3D profile tools specially designed for specifically narrow space, for example, to scan the tooth shape of a human jaw. In this paper, a real-time 3D intraoral scanner is proposed for the measurement of tooth profile in the mouth cavity. The proposed system comprises a laser diode beam, a micro charge-coupled device, a graticule, a piezoelectric transducer, a set of optical lenses, and a polhemus device sensor. The phase-shifting technique is used along with an accurate calibration method for the measurement of the tooth profile. Experimental and theoretical inspection of the phase-to-coordinate relation is presented. In addition, a nonlinear system model is developed for collimating illumination that gives the more accurate mathematical representation of the system, thus improves the shape measurement accuracy. Experiment results are presented to verify the feasibility and performance of the developed system. The experimental results indicate that overall measurement error accuracy can be controlled within 0.4 mm with a variability of ${\pm}0.01$.