• Title/Summary/Keyword: Design department

Search Result 35,787, Processing Time 0.064 seconds

Factors Influencing on Learning Flow of Nursing Students (간호대학생의 학습몰입에 영향을 미치는 요인)

  • Kim, Seon-Hwa;Park, Sang-Youn
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.3
    • /
    • pp.1557-1565
    • /
    • 2014
  • The purpose of this study was to identify the factors influencing learning flow of nursing student. Design of this study was a descriptive research. The participants for this study were 283 nursing college students with four-years curriculum in D city from June 14th to June 24th, 2013. Data were analyzed using descriptive statistics, t-test, one way ANOVA, Pearson's correlation and multiple regression with SPSS 18.0 Program. There were significant correlations among self-leadership, academic self-efficacy, major satisfaction, and the learning flow. As a multiple regression analysis, factors that have an effect on learning flow were self-leadership, and academic self-efficacy. These factors explain 58.2% of the variance in learning flow. Self-leadership, academic self-efficacy, and learning flow relationship were positive relevant. To enhance learning flow ability for nursing students, it is necessary to develop training program and academic environment for increasing self-leadership and academic self-efficacy.

A Study on the delivery of brand image information to consumers by telecom companies' SI(Store Identity) (through comparing SI between Korea telecom companies and foreign famous telecom companies) (통신회사의 SI(Store Identity)가 소비자의 브랜드 이미지 정보전달에 관한 연구(한국통신회사 SI와 해외의 유명 통신회사SI 비교를 통하여))

  • Kim, Jong Sung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.6
    • /
    • pp.2639-2644
    • /
    • 2013
  • The renewal cycle, which newly decorates stores, has been shortened, as the marketing competition between telecommunication companies has been extended to the stores, due to the rapid increase of mobile phone users and fast replacement cycle of products. The store renewal made by major telecommunication companies, including signboard, has been pushed in order for telecommunication companies to give strong impression about their own brand identity to consumers. Consumers want stores not only to sell cheap and high quality products but also to provide customer experience, by which customers can feel store, product and service and accept them. Especially, since the competition between telecommunication companies is getting tough, it is the current trend that the number of stores is increasing much, and telecommunication companies are recently renewing their stores, with the concept of SI(Store Identity), which changes store image into the incorporated image including interior and exterior, rather than just replacing CI(Corporate Identity), when they renew stores. It can be said that SI(Store Identity) is an important factor, by which companies consistently design visual factors such as interior and sign, and then apply them to the interior and exterior of the stores, and thereby give good store image to consumers, and ultimately have great effect on the increase of sales volume. This kind of activity can be image-controlled by companies' Identity Management, and it can be a very important factor in terms of marketing. In this study, it has an objective to compare and analyze SI of domestic telecommunication companies and foreign telecommunication companies, and then suggest effective SI direction.

Development of ICT-based road safety integrated facilities for pedestrian crossing (ICT기반 횡단보도용 교통안전 통합시설물 개발)

  • Cho, Choong-Yuen;Yim, Hong-Kyu;Lee, Min-Jae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.12
    • /
    • pp.93-99
    • /
    • 2017
  • The rate of traffic accidents that occurred in Korea last year is 10 out of every 100,000 people, ranking it 6th among the 35 OECD member countries. The accident rate of children with disabilities and elderly people is also high. The purpose of this study is to introduce traffic safety facilities which have been developed for the reduction of traffic accidents in non-urban areas in Korea through an analysis of the related literature, the accident factors using traffic accident analysis system data and traffic accident characteristics. Traffic safety integrated facilities for ICT-based pedestrian crossings are subject to cross-sectional coverage of child protection zones. The smart safety fence prevents vehicles from parking illegally and informs pedestrians that there is an access vehicle on the pedestrian crossing. The smart bump is designed to warn drivers who are not aware of the pedestrians. In order to standardize the appropriate form and size of the traffic safety facilities for pedestrian crossings, we constructed a standard model for each type, considering the road function, press classification, power, lane number, geometric form, etc. As a result, the rate of traffic accidents involving vulnerable people was reduced. In addition, it is anticipated that the maintenance costs will be reduced by the use of a solar power supply and their compatibility with the existing installed safety fences.

Functional Analysis of 4D CAD System and Improvement of Function for Applying Linear Construction Project (4D CAD시스템의 기능분석 및 선형시설물 적용을 위한 기능 개선 방안)

  • Kim, Hyeon-Seoug;Kang, Leen-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.9
    • /
    • pp.269-278
    • /
    • 2018
  • In Korea, BIM technology is applied mainly to building construction projects, but is expected to be applied rapidly to civil engineering projects because the government is currently considering the mandatory application of BIM for infrastructure facilities. Because the infrastructure project is processed in a horizontal work area, the application of BIM technology is more useful in the schedule management of the construction phase than the interference management of the design phase. The 4D CAD system is a typical BIM technology applied to the schedule management in the construction phase, but the application to the actual project is limited due to the lack of practical functions. This study examined the functions of four representative 4D CAD systems commercialized so that the selection criterion can be provided according to the characteristics of the project, and suggests that the functions that should be improved to have practicability. As a result of functional analysis, the application characteristics of each system were analyzed and the user convenience was suggested. In addition, a linear 4D simulation methodology was developed to improve the functions applicable to civil engineering projects, and ways to improve the utilization of the infrastructure projects as the construction phase BIM were suggested. In railway and road construction projects, most activities, such as earthwork, bridges, and tunnels proceed along the distance axis in a horizontal space. Therefore, a linear 4D simulation method, in which an activity is expressed along a distance axis, can be more practically useful rather than a simple 4D simulation method with a Gantt chart.

Numerical analysis on effect of hole size on Emergency Evacuation Support System (수치해석을 통한 비상피난지원 시스템의 급기구 크기에 따른 유동분석)

  • Kim, Ji Tae;Park, Won Hee;Lee, Duck Hee;Ro, Kyoung-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.4
    • /
    • pp.324-329
    • /
    • 2020
  • The emergency evacuation support system provides a safe means of evacuation by preventing the inflow of smoke through the formation of a smoke shield curtain in fire situations and pressurizing fresh air to the inside of the smoke shield curtain. In this study, numerical analysis was performed to examine the effects of the hole size on the flow inside the smoke curtain. As the air supply size decreased, the flow rate through the air supply was formed relatively uniformly from the inlet to the outlet length of the emergency support system. In addition, the size of the air supply hole was more than 20 mm, the flow rate was very low near the outlet, so the air supply hole size should be smaller than 20 mm. In addition, the minor loss of the air supply hole was calculated to be K = 1.5 from the numerical results. Therefore, the proper design of an emergency evacuation support system is possible using the flow characteristics according to the size and minor loss of the air supply hole.

An Analysis of Flood Damage Influence by Urban Spatial Factors (도시공간적 요인에 의한 침수피해의 영향 분석)

  • Park, Kiyong;Oh, Hoo;Jeon, Won-Sik;Lee, Eui Hoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.9
    • /
    • pp.238-250
    • /
    • 2020
  • This study investigated the long-term measures to minimize flood damage in the event of flooding in urban areas. The relationship between urban spatial factors and the impact of flood damage was analyzed, focusing on non-structural measures. The urban spatial factors were categorized into three parts: open space, disaster prevention facilities, and urbanization sectors. Multiple regression analysis was used to investigate how urban spatial factors influence flood damage. As a result of the analysis, the crucial factors, such as the reduced green areas and parks included in the open space sectors, resulted in an increased flood damage potential. The posterior factors, such as the population density and GRDP included in the urbanization sector concurrently led to an increase in the flood damage potential. Therefore, to better adapt to climate change, it is necessary to establish urban spatial plans strategically, such as green areas and parks. Meanwhile, the population density and GRDP are also the main factors causing flood damage. Therefore, when used appropriately in terms of resilience, it will serve as adaptations and recovery.

A Development of Real-time Vibration Monitoring and Analysis System Linked to the Integrated Management System of Ministry of Public Safety and Security (국민안전처 통합관리시스템 연계 가능한 시설물 진동 감지 및 분석 시스템 개발)

  • Lim, Ji-Hoon;Jung, Jin-Woo;Moon, Dae-Joong;Choi, Dong-Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.20 no.3
    • /
    • pp.130-139
    • /
    • 2016
  • A frequency of earthquake occurrence in the Republic of Korea is increasing over the past few decades. In this situation, an importance of earthquake prevention comes to the fore because the earthquake does damage to structures and causes severe damage of human life. For the earthquake prevention, a real-time vibration measurement for structures is important. As an example, the United States of America and Japan have already been monitoring real-time earthquake acceleration for the important structures and the measured acceleration data has been managed by forming database. This database could be used for revising the seismic design specifications or predicting the damage caused by earthquake. In Korea, Earthquake Recovery Plans Act and Enforcement Regulations are revised and declared lately. Ministry of Public Safety and Security is constructing a integrated management system for the measured earthquake acceleration data. The purpose of this research is to develop a real-time vibration monitoring and analysis system for structures which links to the integrated management system. The developed system contains not only a monitoring function to show real-time acceleration data but also an analysis system to perform fast fourier transform, to obtain natural frequency and earthquake magnitude, to show response spectrum and power spectrum, and to evaluate structural health. Additionally, this system is designed to be able to link to the integrated management system of Ministry of Public Safety and Security. It is concluded that the developed system can be useful to build a safety management network, minimize maintenance cost of structures, and prevention of the structural damage due to earthquake.

Pull-out Capacity of Cast-in-place Anchor for Construction of Precast Concrete Segment Arch (프리캐스트 콘크리트 패널 분절 아치 시공을 위한 선설치 앵커의 인발 강도 평가)

  • Ahn, Jin-Hee;Yim, Hong Jae;Bang, Jin Soo;Jeon, Seok Hyeon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.2
    • /
    • pp.94-102
    • /
    • 2020
  • Precast concrete segment arch system has an economic and construct ability that combined with advantage of precast concrete and arch behavior. A precast concrete segment arch system with outrigger is consisted of segmented precast panels, a steel outrigger rib, and V-strip to connect precast panels with a steel outrigger rib and cast-in-place anchors in precast panels to connect V-strip should have sufficient pull-out capacity to form its arch shape by site lifting for assembled precast panels and outriggers. However, it is difficult to secure its embedment depth due to the relatively shallow thickness of precast panel. It can be also occurred that flexure deformation of precast panels caused by its pull-out behaviors. In this study, pull-out capacity of cast-in-place anchor was examined for construction of precast concrete segment arch system with outriggers. Therefore, a total of 24 precast panel specimens were fabricated to examine pull-out capacities of cast-in-place anchor in precast panels, and installation depth of anchors, diameter of anchors and wire mesh effects for the precast panel were examined. From this pull-out tests, its pull-out capacities and failure modes were evaluated and the type of the cast-in-place anchor applicable to the precast concrete segment panel arch system with outriggers was determined from comparison of the design specification values.

An Analysis on the CCTV Location Appropriateness and Effectiveness for the Crime Prevention (범죄예방을 위한 CCTV 위치 적절성 및 효과성 분석)

  • Heo, Sun-Young;Moon, Tae-Heon
    • Journal of the Korean association of regional geographers
    • /
    • v.21 no.4
    • /
    • pp.739-750
    • /
    • 2015
  • This study aims to investigate the possibility of crime prevention through CCTV by analyzing the appropriateness of the CCTV location, whether it is installed in the hotspot of crime-prone areas, and exploring the crime prevention effect and transition effect. The real crime and CCTV locations of case city were converted into the spatial data by using GIS. The data was analyzed by hotspot analysis and weighted displacement quotient (WDQ). The results demonstrated that there was no significant effect in the installation of CCTV on crime prevention. This indicates that CCTV should be installed and managed in a more scientific way reflecting local crime situations. In terms of CCTV, the methods of spatial analysis such as GIS, which can evaluate the installation effect, and the methods of economic analysis like cost-benefit analysis should be developed. In addition, these methods should be distributed to local governments across the nation for the appropriate installation of CCTV and operation. This study intended to find a design guideline of the optimum CCTV installation. In this regard, this study is meaningful in that it will contribute to the creation of a safe city.

  • PDF

Analysis of Nonlinear Destructive Interaction between Wind and Wave Loads Acting on the Offshore Wind Energy Converter based on the Hydraulic Model Test (해상 풍력발전체에 작용하는 풍하중과 파랑하중간의 비선형 상쇄간섭 해석 -수리모형실험을 중심으로)

  • Cho, Yong Jun;Yang, Kee Sok
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.27 no.5
    • /
    • pp.281-294
    • /
    • 2015
  • In order to quantitatively estimate the nonlinear destructive interaction of wave load with wind load, which is very vital for the optimal design of offshore wind energy converter, we carried out a hydraulic model test and wind tunnel test. As a substructure of offshore wind energy converter, we would deploy the monopile, which is popular due to its easiness in construction. Based on the simulation using Monte Carlo simulation using Kaimal spectrum and cross spectrum, the instantaneous maximum wind velocity is adjusted to 10 m/s. And, considering the wave conditions of the Western Sea where a pilot wind farm is planned to be constructed, $H_s=0.1m$, 0.15 m, 0.2 m is carefully chosen. It turns out that the nonlinear destructive interaction between the wind and wave loads acting on the offshore wind energy converter is more clearly visible at rough seas rather than at mild seas, which strongly support our deduction that a Large eddy, a swirling vortex developed near the bumpy water surface in the opposite direction of the wind, is the driving mechanism underlying nonlinear destructive interaction between the wind and wave loads.