• Title/Summary/Keyword: Design charts

Search Result 282, Processing Time 0.027 seconds

A Study for the design of a Mobile Medical Care System M-LIMS

  • Yang, Kyung-Sik;Koo, Kyung-Wan
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.7 no.2
    • /
    • pp.84-89
    • /
    • 2015
  • About 30% of Mongolian population is populated in the capital of the nation. Too many hospitals are concentrated in size as compared to the capital. This creates a difficult environment to provide equal distribution of medical benefit. In order to resolve this issue of medical benefit inequality, a portable/travelling medical treatment system using 'M-LIMS' is proposed for real-life application. The system with M-LIMS to be designed will include functions such as composing, sharing charts among doctors, standardizing charts. M-LIMS will be designed considering Mongol's regional characteristics, and application plans will be proposed accordingly.

How to Perform FMEA Effectively (효과적인 FMEA 실시)

  • 장중순;안동근
    • Journal of Korean Society for Quality Management
    • /
    • v.25 no.1
    • /
    • pp.156-172
    • /
    • 1997
  • FMEA is a widely used technique to assess or to improve reliability of products at early stage of design and development. In order to implement FMEA effectively, it is important to utilize knowledge or technical know-hows. However, that is very difficult. In fact, if information on the failure modes is enough, it is important to consider a counterplan to eliminate critical failure modes. If engineers do not have such information, however, it is more important to know what failure modes of the component under consideration would undergo. This means that the purposes of performing FMEA varies according to the situation. Therefore, we need different kinds of FMEA charts to meet those purposes. This paper proposes two FMEA charts: one is suitable for detecting potential failure modes and the other is for product improvements.

  • PDF

The Design of Robust Control Chart for A Contaminated Process (오염된 공정을 위한 로버스트 관리도의 설계)

  • Kim, Yong-Jun;Kim, Dong-Hyuk;Chung, Young-Bae
    • Journal of Korean Society for Quality Management
    • /
    • v.40 no.3
    • /
    • pp.327-336
    • /
    • 2012
  • Purpose: In this study, we research the hurdle rate method to suggest the robust control chart for a contaminated process less vulnerable to fault values than existing control charts. Methods: We produce the results of p, ARL values to compare the performance of two control charts, $\bar{x}-s$ that has been used typically and TM-TS that is suggested by this paper. We implement the simulation focusing on three cases, change of deviation, mean and both of them. Results: We draw a conclusion that the TM-TS control chart has better efficiency than $\bar{x}-s$ control chart over the three cases. Conclusion: We insist that applying TM-TS control chart for a polluted process is more effective than $\bar{x}-s$ control chart.

Design of Modified ${\bar{x}}$-s Control Chart based on Robust Estimation (로버스트 추정에 근거한 수정된 ${\bar{x}}$-s 관리도의 설계)

  • Chung, Young-Bae;Kim, Yon-Soo
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.38 no.1
    • /
    • pp.15-20
    • /
    • 2015
  • Control charts are generally used for process control, but the role of traditional control charts have been limited in case of a non-contaminated process. Traditional ${\bar{x}}$-s control chart has not been activated well for such a problem because of trying to control processes as center line and control limits changed by the contaminated value. This paper suggests modified ${\bar{x}}$-s control chart based on robust estimation. In this paper, we consider the trimmed mean of the sample means and the trimmed mean of the sample standard deviations. By comparing with ARL value, the responding results are decided. The comparison resultant results of traditional control chart and modified control chart are contrasted.

Distribution of average rainfall event-depth for overflow risk-based design of detention storage basin (월류위험도 기반 저류지 설계를 위한 평균강우량도 작성)

  • Kim, Dae Geun;Park, Sun Jung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.1
    • /
    • pp.15-22
    • /
    • 2008
  • This study collected the latest 30-year (1976~2005) continuous rainfall data hourly recorded at 61 meterological observatories in Korea, and the continuous rainfall data was divided into individual rainfall events. In addition, distribution charts of average rainfall event-depth were created to facilitate the application to the overflow risk-based design of detention storage basin. This study shows that 4 hour is appropriate for SST (storm separation time) to separate individual rainfall events from the continuous rainfall data, and the one-parameter exponential distribution is suitable for the frequency distribution of rainfall event depths for the domestic rainfall data. The analysis of the domestic rainfall data using SST of 4 hour showed that the individual rainfall event was 1380 to 2031 times, the average rainfall event-depth was 19.1 to 32.4mm, and ranged between 0.877 and 0.926. Distribution charts of average rainfall event-depth were created for 4hour and 6 hour of SST, respectively. The inland Gyeongsangbuk-do, Western coastal area and inland of Jeollabuk-do had relatively lower average rainfall event-depth, whereas Southern coastal area, such as Namhae, Yeosu, and Jeju-do had relatively higher average rainfall event-depth.

Analytical solution of seismic stability against overturning for a rock slope with water-filled tension crack

  • Zhang, Yanjun;Nian, Tingkai;Zheng, Defeng;Zheng, Lu
    • Geomechanics and Engineering
    • /
    • v.11 no.4
    • /
    • pp.457-469
    • /
    • 2016
  • Steep rock slope with water-filled tension crack will happen to overturn around the toe of the slope under seismic loading. This failure type is completely different from the common toppling failure occurring in anti-dipping layered rock mass slopes with steeply dipping discontinuities. This paper presents an analytical approach to determine the seismic factor of safety against overturning for an intact rock mass slope with water-filled tension crack considering horizontal and vertical seismic coefficients. This solution is a generalized explicit expression and is derived using the moment equilibrium approach. A numerical program based on discontinuous deformation analysis (DDA) is adopted to validate the analytical results. The parametric study is carried out to adequately investigate the effect of horizontal and vertical seismic coefficients on the overall stability against overturning for a saturated rock slope under two water pressure modes. The analytical results show that vertically upward seismic inertia force or/and second water pressure distribution mode will remarkably decrease the slope stability against overturning. Finally, several representative design charts of slopes also are presented for the practical application.

Design and Implementation of Dashboard Author and Viewer for IoT Systems based on MQTT (MQTT 기반 IoT 시스템을 위한 대시보드 저작 및 뷰어의 설계 및 구현)

  • Hwang, Kitae
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.18 no.5
    • /
    • pp.31-37
    • /
    • 2018
  • When an IoT system is constructed, a dashboard is also developed to monitor the values of sensors in the IoT System. Much time and money, however, are spent in developing the dashboard software. This paper presents design and implementation details of a dashboard maker called as YellowPeach, which helps to create a dashboard easily and fast without programming. Using YellowPeach, the user can author a dashboard by putting predefined charts to display values of sensors in it, and store the dashboard as a JSON file. Also an web application has been developed to run the dashboard on the web browser. The dashboard viewer web application connects on MQTT-based IoT system, receives values from the sensors, and displays the values on charts in real-time.

Design of Median Control Chart for Nonnormally Distributed Processes (비정규분포공정(非正規分布工程)에서 메디안특수관리도(特殊管理圖)의 모형설계(模型設計))

  • Sin, Yong-Baek
    • Journal of Korean Society for Quality Management
    • /
    • v.15 no.2
    • /
    • pp.10-19
    • /
    • 1987
  • Statistical control charts are useful tools to monitor and control the manufacturing processes and are widely used in most Korean industries. Many Korean companies, however, do not always obtain desired results from the traditional control charts by Shewhart such as the $\overline{X}$-chart, X-chart, $\widetilde{X}$-chart, etc. This is partly because the quality charterstics of the process are not distributed normally but are skewed due to the intermittent production, small lot size, etc. In the Shewhart $\overline{X}$-chart, which is the most widely used one in Korea, such skewed distributions make the plots to be inclined below or above the central line or outside the control limits although no assignable causes can be found. To overcome such shortcomings in nonnormally distributed processes, a distribution-free type of confidence interval can be used, which should be based on order statistics. This thesis is concerned with the design of control chart based on a sample median which is easy to use in practical situation and therefore properties for nonnormal distributions may be easily analyzed. Control limits and central lines are given for the more famous nonnormal distributions, such as Gamma, Beta, Lognormal, Weibull, Pareto, and Truncated-normal distributions.

  • PDF

Analysis of the Current State of Clothing Size System in Children's Clothing Online Shopping Malls (아동복 온라인쇼핑몰 업체의 의류 치수체계 현황분석)

  • Jeong, Hwa-Yeon
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.24 no.3
    • /
    • pp.145-158
    • /
    • 2022
  • To grasp the size system of children's clothing online shopping malls, basic size charts for clothing products from 14 shopping malls were collected, compared, and analyzed. Looking at the age range of the basic size chart for each company, the minimum age is 1 year old, the maximum age is 14-15 years old, and all companies included ages up to 7 years. In addition, as for the number of size designations, children's clothing companies used seven to eight designations, and there were six types of size designation methods. Next, looking at the height range for each size, even with the same size designation method, the height range differed depending on the company. Also, the KS size standard does not consider body weight, but many companies use weight as a reference body size. Compared with the child body size data of the 6th Korean Body Size Data, the height and weight range for each size provided by the company showed differences between companies. The results of this study can be used in the future as basic data when revising and supplementing the clothing sizes in children's clothing companies.

A Design of Control Chart for Fraction Nonconforming Using Fuzzy Data (퍼지 데이터를 이용한 불량률(p) 관리도의 설계)

  • 김계완;서현수;윤덕균
    • Journal of Korean Society for Quality Management
    • /
    • v.32 no.2
    • /
    • pp.191-200
    • /
    • 2004
  • Using the p chart is not adequate in case that there are lots of data and it is difficult to divide into products conforming or nonconforming because of obscurity of binary classification. So we need to design a new control chart which represents obscure situation efficiently. This study deals with the method to performing arithmetic operation representing fuzzy data into fuzzy set by applying fuzzy set theory and designs a new control chart taking account of a concept of classification on the term set and membership function associated with term set.