• Title/Summary/Keyword: Depth images

Search Result 1,244, Processing Time 0.03 seconds

Calcium-doped zinc oxide nanocrystals as an innovative intracanal medicament: a pilot study

  • Gabriela Leite de Souza;Thamara Eduarda Alves Magalhaes;Gabrielle Alves Nunes Freitas;Nelly Xiomara Alvarado Lemus;Gabriella Lopes de Rezende Barbosa;Anielle Christine Almeida Silva;Camilla Christian Gomes Moura
    • Restorative Dentistry and Endodontics
    • /
    • v.47 no.4
    • /
    • pp.38.1-38.15
    • /
    • 2022
  • Objectives: This study investigated the cytotoxicity, radiopacity, pH, and dentinal tubule penetration of a paste of 1.0% calcium-doped zinc oxide nanocrystals (ZnO:1.0Ca) combined with propylene glycol (PRG) or polyethylene glycol and propylene glycol (PEG-PRG). Materials and Methods: The pastes were prepared by mixing calcium hydroxide [Ca(OH)2] or ZnO:1.0Ca with PRG or a PEG-PRG mixture. The pH was evaluated after 24 and 96 hours of storage in deionized water. Digital radiographs were acquired for radiopacity analysis and bubble counting of each material. The materials were labeled with 0.1% fluorescein and applied to root canals, and images of their dentinal tubule penetration were obtained using confocal laser scanning microscopy. RAW264.7 macrophages were placed in different dilutions of culture media previously exposed to the materials for 24 and 96 hours and tested for cell viability using the MTT assay. Analysis of variance and the Tukey test (α = 0.05) were performed. Results: ZnO:1.0Ca materials showed lower viability at 1:1 and 1:2 dilutions than Ca(OH)2 materials (p < 0.0001). Ca(OH)2 had higher pH values than ZnO:1.0Ca at 24 and 96 hours, regardless of the vehicle (p < 0.05). ZnO:1.0Ca pastes showed higher radiopacity than Ca(OH)2 pastes (p < 0.01). No between-material differences were found in bubble counting (p = 0.0902). The ZnO:1.0Ca pastes had a greater penetration depth than Ca(OH)2 in the apical third (p < 0.0001). Conclusions: ZnO:1.0Ca medicaments presented higher penetrability, cell viability, and radiopacity than Ca(OH)2. Higher values of cell viability and pH were present in Ca(OH)2 than in ZnO:1.0Ca.

A Consideration on Creativity of the Unconscious: Focusing on a Series of Dreams (무의식의 창조성에 관한 하나의 고찰: 일련의 꿈을 중심으로)

  • Dukkyu Kim
    • Sim-seong Yeon-gu
    • /
    • v.38 no.2
    • /
    • pp.239-268
    • /
    • 2023
  • Humanity has faced destruction(chaos) due to catastrophes (Covid-19, war, earthquake) and awaits a new restoration. For civilizations and individuals, creation or creativity is essential to psychic development. Creativity is the driving force that renews an individual when a new stance and attitude of consciousness or a new adaptation to reality is desperately needed in the depth of the human mind. This article is the result of an exploration of the nature and characteristics of creativity presented by a series of four dreams. First, the definition and form of creativity were explored in the context of religion, mythology, and history of Eastern and Western. While Western mythology refers to creation or creativity originating from God, ancient China viewed creativity as expressed through the interaction of yin and yang, the movement of Tao. In East and West, the form of creation is divided into creation from nothing, creation from matter, and creation through dissolution from the matrix, which psychologically suggests that creativity or creation originates from the unconscious, the seedbed of infinite potential and creative power. Next, with insights from the second dream, the characteristics of creativity were discussed. Creativity occurs through transcendent function and 'going beyond the frame of reference,' that is, 'transgressivity.' Third, the nature of creativity was explored as the creativity of the unconscious aims for regeneration and drives the renewal of Self archetypal images within the collective and individuals. Ultimately, the creativity of the unconscious is the goal of the whole psyche and aims for individuation to become the whole. Realizing the creativity of the unconscious is the fate of humans as the second creator.

Foundation Color Image Analysis (파운데이션 색상 이미지 분석)

  • Hee-Kyung Lim
    • Journal of the Korean Applied Science and Technology
    • /
    • v.40 no.6
    • /
    • pp.1580-1588
    • /
    • 2023
  • The desire for clear and clean skin is universal among both men and women. Women, in particular, seek the help of foundation to achieve beautiful and transparent skin. The choice of foundation is not determined by the race of an individual; instead, it varies based on personal skin color and undertone. Therefore, there is a need to surpass the stereotype of using foundation colors based on racial discrimination. The purpose of this study is to randomly select cosmetics brands from Korea, China, Japan, the United States, France, and the United Kingdom, considering the impact of each photo, environment, and equipment. The objective is to understand the differences in skin tones in foundation advertisement model images on websites. Analyzing the RGB values of foundation colors for each brand revealed that in Korea, the colors were 8.75R, 1.25YR, 2.5YR, 3.75YR, 5YR, and 6.25YR. Chinese brands showed similar colors with 2.5YR, 3.75YR, 5YR, 6.25YR, and 10YR. Japanese brands displayed colors such as 7.5R, 8.75R, 10R, 5YR, 6.25YR, and 7.5YR. American brands presented colors like 6.25R, 8.75R, 10R, 2.5YR, 3.75YR, 5YR, 6.25YR, 7.5YR, and 10YR. French brands featured 10R, 1.25YR, 3.75YR, 5YR. Lastly, British brands displayed 2.5YR, 3.75YR, 7.5YR. As a follow-up study, in-depth research on the reshaping and color changes of foundation over time is recommended. It is hoped that this research will serve as fundamental data for makeup companies' marketing and contribute to the development of both domestic and international color cosmetics markets.

Automation of Online to Offline Stores: Extremely Small Depth-Yolov8 and Feature-Based Product Recognition (Online to Offline 상점의 자동화 : 초소형 깊이의 Yolov8과 특징점 기반의 상품 인식)

  • Jongwook Si;Daemin Kim;Sungyoung Kim
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.17 no.3
    • /
    • pp.121-129
    • /
    • 2024
  • The rapid advancement of digital technology and the COVID-19 pandemic have significantly accelerated the growth of online commerce, highlighting the need for support mechanisms that enable small business owners to effectively respond to these market changes. In response, this paper presents a foundational technology leveraging the Online to Offline (O2O) strategy to automatically capture products displayed on retail shelves and utilize these images to create virtual stores. The essence of this research lies in precisely identifying and recognizing the location and names of displayed products, for which a single-class-targeted, lightweight model based on YOLOv8, named ESD-YOLOv8, is proposed. The detected products are identified by their names through feature-point-based technology, equipped with the capability to swiftly update the system by simply adding photos of new products. Through experiments, product name recognition demonstrated an accuracy of 74.0%, and position detection achieved a performance with an F2-Score of 92.8% using only 0.3M parameters. These results confirm that the proposed method possesses high performance and optimized efficiency.

Estimation of POC Export Fluxes Using 234Th/238U Disequilibria in the Amundsen Sea, Antarctica; Preliminary Result (남극 아문젠해에서 234Th/238U 비평형법을 사용한 유광대에서 심층으로의 입자상 유기탄소 침강플럭스 추정; 예비결과)

  • Kim, Mi Seon;Choi, Man Sik;Lee, Sang Heon;Lee, Sang Hoon;Rhee, Tae Siek;Hahm, Doshik
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.19 no.2
    • /
    • pp.109-124
    • /
    • 2014
  • In order to understand the carbon cycle in the Amundsen Sea of the Southern Ocean, the export fluxes of particulate organic carbon from the euphotic zone to deep water estimated using ${\psi}$/${\psi}$ disequilibrium method. Seawaters in 14 water columns were collected during February and March 2012, and analyzed for total and dissolved ${\psi}$, and particulate organic carbon. Total ${\psi}$ activities in the water column showed deficiency and excess relative to those of ${\psi}$ depending on the water depth. Deficiency of total ${\psi}$ in the euphotic zone showed mirror images both with chlorophyll-a and fluorescence, and was consistent with the loss of nitrate, which indicated the effect of biological activity. In addition, deficiency of total ${\psi}$ from deep water was associated with the increase of total dissolvable Fe/Mn concentration. Excess total ${\psi}$ activity presented below the euphotic zone might be related to particulate ${\psi}$ concentrated in this water depth. Mean export flux of ${\psi}$ estimated using the steady state model was $867{\pm}246dpmm^{-2}day^{-1}$. Mean export flux of particulate organic carbon, which were estimated by the product of total ${\psi}$ flux and ratio of POC/${\psi}$ ($7.08{\pm}4.27{\mu}molCdpm^{-1}$) in the sinking particles, was $5.9{\pm}3.9mmolCm^{-2}day^{-1}$. These fluxes were similar levels to those in the Weddell Sea during February and March 2008. Export ratios (ThE) relative to the primary production in the euphotic zone were in the range of 3-54% (av. 28%).

Evaluation of Electron Boost Fields based on Surgical Clips and Operative Scars in Definitive Breast Irradiation (유방보존술 후 방사선치료에서 수술 흉터와 삽입된 클립을 이용한 전자설 추가 방사선 조사야 평가)

  • Lee, Re-Na;Chung, Eun-Ah;Lee, Ji-Hye;Suh, Hyun-Suk
    • Radiation Oncology Journal
    • /
    • v.23 no.4
    • /
    • pp.236-242
    • /
    • 2005
  • Purpose: To evaluate the role of surgical clips and scars in determining electron boost field for early stage breast cancer undergoing conserving surgery and postoperative radiotherapy and to provide an optimal method in drawing the boost field. Materials and Methods: Twenty patients who had $4{\sim}7$ surgical clips in the excision cavity were selected for this study. The depth informations were obtained to determine electron energy by measuring the distance from the skin to chest wall (SCD) and to the clip implanted in the most posterior area of tumor bed. Three different electron fields were outlined on a simulation film. The radiological tumor bed was determined by connecting all the clips implanted during surgery Clinical field (CF) was drawn by adding 3 cm margin around surgical scar. Surgical field (SF) was drawn by adding 2 cm margin around surgical clips and an Ideal field (IF) was outlined by adding 2 cm margin around both scar and clips. These fields were digitized into our planning system to measure the area of each separate field. The areas of the three different electron boost fields were compared. Finally, surgical clips were contoured on axial CT images and dose volume histogram was plotted to investigate 3-dimensional coverage of the clips. Results : The average depth difference between SCD and the maximal clip location was $0.7{\pm}0.55cm$. Greater difference of 5 mm or more was seen in 12 patients. The average shift between the borders of scar and clips were 1.7 1.2, 1.2, and 0.9 cm in superior, inferior, medial, and lateral directions, respectively. The area of the CF was larger than SF and IF in 6y20 patients. In 15/20 patients, the area difference between SF and if was less than 5%. One to three clips were seen outside the CF in 15/20 patients. In addition, dosimetrically inadequate coverage of clips (less than 80% of prescribed dose) were observed in 17/20 patients when CF was used as the boost field. Conclusion: The electron field determined from clinical scar underestimates the tumor bed in superior-inferior direction significantly and thereby underdosing the tissue at risk. The electron field obtained from surgical clips alone dose not cover the entire scar properly As a consequence, our technique, which combines the surgical clips and clinical scars in determining electron boost field, was proved to be effective in minimizing the geographical miss as well as normal tissue complications.

Comparative Analysis of Bathymetry in the Dongdo and the Seodo, Dokdo using Multibeam Echosounder System (다중빔 음향 측심기를 이용한 독도 동도와 서도 남부 연안 해저지형 비교 분석)

  • Lee, Myoung Hoon;Kim, Chang Hwan;Park, Chan Hong;Rho, Hyun Soo;Kim, Dae Choul
    • Economic and Environmental Geology
    • /
    • v.50 no.6
    • /
    • pp.477-486
    • /
    • 2017
  • In this study, we analyze precise seabed geomorphology and conditions for comparing the nearshore areas of the Dongdo(East Island) and the Seodo(West Island) using detailed bathymetry data and seafloor backscattering images, in Dokdo, the East Sea. We have been obtained the detailed bathymetry data and the seafloor backscattering data. The survey range is about $250m{\times}250m$ including land of islets to the nearshore areas of the southern part of the Dongdo and the Seodo. As a result of bathymetry survey, the southern area of the Dongdo(~50 m) is deeper than the Seodo(~30 m) in the water depth. The survey areas are consist of extended bedrocks from land of the Dongdo and the Seodo. The underwater rock region of the Seodo is larger than the Dongdo. In spite of similar extended rocks features from islets, there are some distinctive seabed characteristics between the southern nearshore areas of the Dongdo and the Seodo. The Talus-shaped seafloor environment formed by gravel and underwater rocks originating from the land of the Dongdo is up to about 15 m depth. And the boundary line of between extended bedrocks and seabottom is unclear in the southern nearshore of the Dongdo. On the other hand, the southern coast of the Seodo is characterized by relatively large scale underwater rocks and evenly distributed sediments, which clearly distinguish the boundary of between extended bedrocks and seafloor. This is because the tuff layers exposed to the coastal cliffs of the Dongdo are weak against weathering and erosion. It is considered that there are more influences of the clastic sediments carried from the land of the Dongdo compared with the Seodo. Particularly, the land of the Dongdo has been undergoing construction activities. And also a highly unstable ground such as faults, joints and cracks appears in the Dongdo. In previous study, there are dissimilar features of the massive tuff breccia formations of the Dongdo and the Seodo. These conditions are thought to have influenced the different seabed characteristics in the southern nearshore areas of the Dongdo and the Seodo.

Development of a Small Animal Positron Emission Tomography Using Dual-layer Phoswich Detector and Position Sensitive Photomultiplier Tube: Preliminary Results (두층 섬광결정과 위치민감형광전자증배관을 이용한 소동물 양전자방출단층촬영기 개발: 기초실험 결과)

  • Jeong, Myung-Hwan;Choi, Yong;Chung, Yong-Hyun;Song, Tae-Yong;Jung, Jin-Ho;Hong, Key-Jo;Min, Byung-Jun;Choe, Yearn-Seong;Lee, Kyung-Han;Kim, Byung-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.5
    • /
    • pp.338-343
    • /
    • 2004
  • Purpose: The purpose of this study was to develop a small animal PET using dual layer phoswich detector to minimize parallax error that degrades spatial resolution at the outer part of field-of-view (FOV). Materials and Methods: A simulation tool GATE (Geant4 Application for Tomographic Emission) was used to derive optimal parameters of small PET, and PET was developed employing the parameters. Lutetium Oxyorthosilicate (LSO) and Lutetium-Yttrium Aluminate-Perovskite(LuYAP) was used to construct dual layer phoswitch crystal. $8{\times}8$ arrays of LSO and LuYAP pixels, $2mm{\times}2mm{\times}8mm$ in size, were coupled to a 64-channel position sensitive photomultiplier tube. The system consisted of 16 detector modules arranged to one ring configuration (ring inner diameter 10 cm, FOV of 8 cm). The data from phoswich detector modules were fed into an ADC board in the data acquisition and preprocessing PC via sockets, decoder block, FPGA board, and bus board. These were linked to the master PC that stored the events data on hard disk. Results: In a preliminary test of the system, reconstructed images were obtained by using a pair of detectors and sensitivity and spatial resolution were measured. Spatial resolution was 2.3 mm FWHM and sensitivity was 10.9 $cps/{\mu}Ci$ at the center of FOV. Conclusion: The radioactivity distribution patterns were accurately represented in sinograms and images obtained by PET with a pair of detectors. These preliminary results indicate that it is promising to develop a high performance small animal PET.

Usefulness of Flow Composite Image in Raynaud Scan ($^{201}Tl$) ($^{201}Tl$을 이용한 레이노 검사에서 동적 Composite 영상의 유용성)

  • Kim, Dae-Yeon;Shin, Gyoo-Seol;Oh, Eun-Jung;Kim, Gun-Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.101-104
    • /
    • 2010
  • Purpose: Raynaud scan is divided to flow, blood pool and local-delay image. Usually, we evaluate comparison through blood pool and local-delay image. We will evaluate about usability when comparative observe blood image and local-delay image in Raynaud scan that used $^{201}Tl$ as making flow image to one sheet of images. Materials and Methods: We have selected 29 Raynaud phenomenon patients aged 14~68 years who visited department of vascular surgery between Feb. 2008 and Aug. 2009. An intravenous injection $^{201}Tl$ of 111 MBq (3 mCi) to opposite side diagonal line limbs above an internal auditing department. Equipment used Philips gamma camera forte A-Z, and collimator used LEHR. Matrix size set up to each $64{\times}64$, $128{\times}128$, $256{\times}256$ and zoom factor used to full field. Protocol of dynamic is 2 second to 155 frames. Blood pool and delay count to 300 second. We set up ROI by a foundation to data acquired in PEGASYS processing program. Each results were analyzed with the SPSS 12.0 statistical software. Results: Each averages of count ratio (Rt / Lt) to have been given at composite image, a blood pool image, delay images analyzed at Raynaud phenomenon patients is $1.25{\pm}0.39$, $1.20{\pm}0.33$, $1.11{\pm}0.17$. The sample analysis results of blood pool image and delay image contented itself with p<0.029. Also, there don't have been each difference, and blood pool image, delay image regarding composite image was able to know. Conclusion: We were able to give help for comparison to evaluate a blood pool image and a local delay image at the Raynaud scan which used $^{201}Tl$ while making a flow image to one sheet image. Identification to be visual too was possible. If you are proceeded a researcher that there was further depth, you are more appropriate for, and you may get useful information.

  • PDF

A study on optical coherence tomography system using optical fiber (광섬유를 이용한 광영상 단층촬영기에 관한연구)

  • 양승국;박양하;장원석;오상기;김현덕;김기문
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2004.04a
    • /
    • pp.5-9
    • /
    • 2004
  • In this paper, we studied the OCT(Optical Coherence Tomography) system which it has been extensively studied because of having some advantages such as high resolution cross-sectional images, low cost, and small size configuration. A basic principle of OCT system is Michelson interferometer. The characteristics of light source determine the resolution and the transmission depth. As a results, the light source have a commercial SLD with a central wavelength of 1,285 nm and FWHM(Full Width at Half Maximum) of 35.3 nm. The optical delay line part is necessary to equal of the optical path length with scattered light or reflected light from sample. In order to equal the optical path length, the stage which is attached to reference mirror is moved linearly by step motor And the interferometer is configured with the Michelson interferometer using single mod fiber, the scanner can be focused of the sample by using the reference arm. Also, the 2-dimensional cross-sectional images were measured with scanning the transverse direction of the sample by using step motor. After detecting the internal signal of lateral direction at a paint of sample, scanner is moved to obtain the cross-sectional image of 2-demensional by using step motor. Photodiode has been used which has high detection sensitivity, excellent noise characteristic, and dynamic range from 800 nm to 1,700 nm. It is detected mixed small signal between noise and interference signal with high frequency After filtering and amplifying this signal, only envelope curve of interference signal is detected. And then, cross-sectional image is shown through converting this signal into digitalized signal using A/D converter. The resolution of the OCT system is about 30$\mu\textrm{m}$ which corresponds to the theoretical resolution. Also, the cross-sectional image of ping-pong ball is measured. The OCT system is configured with Michelson interferometer which has a low contrast because of reducing the power of feedback interference light. Such a problem is overcomed by using the improved inteferometer. Also, in order to obtain the cross-sectional image within a short time, it is necessary to reduce the measurement time for improving the optical delay line.

  • PDF