• Title/Summary/Keyword: Depth Measure Sensor

Search Result 73, Processing Time 0.029 seconds

Development of Force/Displacement Sensing System for Nanomachining (나노 가공을 위한 힘.변위 검출시스템 개발)

  • Bang, Jin-Hyeok;Kwon, Ki-Hwan;Park, Jae-Jun;Cho, Nahm-Gyoo
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.777-781
    • /
    • 2004
  • This paper presents a force/displacement sensing system to measure penetration depths and machining forces during pattering operation. This sensing system consists of a leaf spring mechanism and a capacitive sensor, which is mounted on a PZT driven in-feed motion stage with 1nm resolution. The sample is moved by a xy scanning motion stage with 5nm resolution. The constructed system was applied to nano indentation experiments, and the load-displacement curves of silicon(111) and aluminum were obtained. Then, the indentation samples were measured by AFM. Experimental results demonstrated that the developed system has the ability of preforming force/depth sensing indentations

  • PDF

Development of 3-channel Pulse Wave Measurement System (3채널 맥파 측정 시스템 개발)

  • Kim, Eun-Geun;Heo, Hyun;Nam, Ki-Chang;Kang, Hee-Jung;Huh, Young
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.1049-1050
    • /
    • 2008
  • It is difficult to measure the pulse wave in a short time because radial artery position and located depth are different depending on the person. In this paper, the pulse wave measurement system was developed using 3 channel piezoresistive sensor array to detect the most significant pulse wave. Augmentation Index(AI) and Heart Rate(HR) analysis are also available for predicting cardiovascular risks. The developed system is small and easy to use. And it is promising to be used as home healthcare device.

  • PDF

Study on air pocket design of thrust bearing for high-stiffness air spindle (공기 주축 고강성화를 위한 스러스트 베어링의 에어포켓 설계에 관한 연구)

  • Han, Young-Chil;Lee, Chae-Moon;Lee, Deug-Woo;An, Dae-Geun
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.998-1002
    • /
    • 2003
  • This paper investigates the characteristics of stiffness and load in the thrust bearing of spindle which could be changeable according to the groove shape of inlet, in order to design a high-stiffness air bearing by selecting a optimal groove shape. In experiments, dead weight and displacement sensor are used to measure the load carrying capacity and the stiffness respectively. Various shapes and different depth of groove of self-restrictor are used as experimental conditions. Comparative study between the theoretical value and the practical one by measuring the value of stiffness and load of the thrust bearing is performed.

  • PDF

Development of a Fixing Apparatus Available to Mount-and-detach ADCP on a Small Vessel (소형선박용 착.탈식 ADCP 고정장치 개발)

  • Hwang, Sang-Chul;Jeon, Dong-Chull;Kang, Jae-Hoon;Kim, Cheol-Soo
    • Ocean and Polar Research
    • /
    • v.26 no.3
    • /
    • pp.481-486
    • /
    • 2004
  • A portable apparatus mounting Acoustic Doppler Current Profilers (ADCP) to any small boat was developed to effectively measure currents in shallow and narrow coastal seas like the west coasts of Korea. Characteristics of the apparatus is that an underwater fish-shaped body protecting an ADCP is designed to reduce the drag during the cruise, which can be freely mounted and detached from a boat with a clamp. Several cruise outputs prove themselves that the apparatus is properly designed for the intended purpose, to minimize air bubbles and to control the submerged depth of the sensor.

Measurement of Skin Dose and Percentage Depth Does in Build-up Region Using a Fiber-optic Dosimeter (광섬유 방사선량계를 이용한 선량보강 영역에서의 심부선량 백분율과 피부 선량률 측정)

  • Cho, Dong-Hyun;Jang, Kyoung-Won;Yoo, Wook-Jae;Seo, Jeong-Ki;Heo, Ji-Yeon;Lee, Bong-Soo;Cho, Young-Ho
    • Korean Journal of Optics and Photonics
    • /
    • v.21 no.1
    • /
    • pp.16-20
    • /
    • 2010
  • In this study, we have fabricated a fiber-optic dosimeter using an organic scintillator and a plastic optical fiber. The dosimeter measure skin dose and percentage depth dose in a build-up region for an incident high energy photon beam. The scintillating light generated in the organic sensor probe embedded in a solid water phantom is guided by 30 m plastic optical fiber to a light-measuring device such as a PMT or an electrometer. In addition, using a fiber-optic dosimeter or a GAFCHROMIC EBT film, skin dose and percentage depth dose in the build-up region are measured and compared.

Measurements of simulated periodontal bone defects in inverted digital image and film-based radiograph: an in vitro study

  • De Molon, Rafael Scaf;Morais-Camillo, Juliana Aparecida Najarro Dearo;Sakakura, Celso Eduardo;Ferreira, Mauricio Goncalves;Loffredo, Leonor Castro Monteiro;Scaf, Gulnara
    • Imaging Science in Dentistry
    • /
    • v.42 no.4
    • /
    • pp.243-247
    • /
    • 2012
  • Purpose: This study was performed to compare the inverted digital images and film-based images of dry pig mandibles to measure the periodontal bone defect depth. Materials and Methods: Forty 2-wall bone defects were made in the proximal region of the premolar in the dry pig mandibles. The digital and conventional radiographs were taken using a Schick sensor and Kodak F-speed intraoral film. Image manipulation (inversion) was performed using Adobe Photoshop 7.0 software. Four trained examiners made all of the radiographic measurements in millimeters a total of three times from the cementoenamel junction to the most apical extension of the bone loss with both types of images: inverted digital and film. The measurements were also made in dry mandibles using a periodontal probe and digital caliper. The Student's t-test was used to compare the depth measurements obtained from the two types of images and direct visual measurement in the dry mandibles. A significance level of 0.05 for a 95% confidence interval was used for each comparison. Results: There was a significant difference between depth measurements in the inverted digital images and direct visual measurements (p>|t|=0.0039), with means of 6.29 mm ($IC_{95%}$:6.04-6.54) and 6.79 mm ($IC_{95%}$:6.45-7.11), respectively. There was a non-significant difference between the film-based radiographs and direct visual measurements (p>|t|=0.4950), with means of 6.64mm($IC_{95%}$:6.40-6.89) and 6.79mm($IC_{95%}$:6.45-7.11), respectively. Conclusion: The periodontal bone defect measurements in the inverted digital images were inferior to film-based radiographs, underestimating the amount of bone loss.

The Vibration Measurement of Boring Process by Using the Optical Fiber Sensor at inside of Boring Bar (광섬유 센서의 보링 바 삽입에 의한 진동측정)

  • Song, Doo-Sang;Hong, Jun-Hee;Guo, Yang-Yang
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.28 no.6
    • /
    • pp.709-715
    • /
    • 2011
  • Chattering in cutting operations are usually a cumbersome part of the manufacturing process in mechanical. Particular, machining performance such as that of the boring process is limited by cutting condition at the movable components. Among various sources of chatter vibration, detrimental point in cutting condition is found a mechanical condition on overhang. It limits cutting speed, depth, surface roughness and tool wear failure as result because the all properties are varying with the metal removal process. In this case, we have to observe the resonance frequencies of a boring bar for continuous cutting. In the established research, boring bar vibration of cutting system has been measured with the aid of accelerometer. However, the inherent parameters of internal turning operations are severely limit for the real time monitoring on accelerometers. At this point, this paper is proposed other method for real time monitoring during continuous cutting with optical fiber at the inside of boring bar. This method has been used a plastic fiber in the special jig on boring bar by based on experimental modal analysis. In this study, improvement of monitoring system on continuous internal cutting was attempted using optical fiber sensor of inside type because usually chattering is investigated experimentally measuring the variation in chip thickness. It is demonstrated that the optical fiber sensor is possibility to measure of chattering with real time in boring process.

Investigation for Shoulder Kinematics Using Depth Sensor-Based Motion Analysis System (깊이 센서 기반 모션 분석 시스템을 사용한 어깨 운동학 조사)

  • Lee, Ingyu;Park, Jai Hyung;Son, Dong-Wook;Cho, Yongun;Ha, Sang Hoon;Kim, Eugene
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.1
    • /
    • pp.68-75
    • /
    • 2021
  • Purpose: The purpose of this study was to analyze the motion of the shoulder joint dynamically through a depth sensor-based motion analysis system for the normal group and patients group with shoulder disease and to report the results along with a review of the relevant literature. Materials and Methods: Seventy subjects participated in the study and were categorized as follows: 30 subjects in the normal group and 40 subjects in the group of patients with shoulder disease. The patients with shoulder disease were subdivided into the following four disease groups: adhesive capsulitis, impingement syndrome, rotator cuff tear, and cuff tear arthropathy. Repeating abduction and adduction three times, the angle over time was measured using a depth sensor-based motion analysis system. The maximum abduction angle (θmax), the maximum abduction angular velocity (ωmax), the maximum adduction angular velocity (ωmin), and the abduction/adduction time ratio (tabd/tadd) were calculated. The above parameters in the 30 subjects in the normal group and 40 subjects in the patients group were compared. In addition, the 30 subjects in the normal group and each subgroup (10 patients each) according to the four disease groups, giving a total of five groups, were compared. Results: Compared to the normal group, the maximum abduction angle (θmax), the maximum abduction angular velocity (ωmax), and the maximum adduction angular velocity (ωmin) were lower, and abduction/adduction time ratio (tabd/tadd) was higher in the patients with shoulder disease. A comparison of the subdivided disease groups revealed a lower maximum abduction angle (θmax) and the maximum abduction angular velocity (ωmax) in the adhesive capsulitis and cuff tear arthropathy groups than the normal group. In addition, the abduction/adduction time ratio (tabd/tadd) was higher in the adhesive capsulitis group, rotator cuff tear group, and cuff tear arthropathy group than in the normal group. Conclusion: Through an evaluation of the shoulder joint using the depth sensor-based motion analysis system, it was possible to measure the range of motion, and the dynamic motion parameter, such as angular velocity. These results show that accurate evaluations of the function of the shoulder joint and an in-depth understanding of shoulder diseases are possible.

Analysis of the PTO Torque of a Transplanter by Planting Condition

  • Kim, Wan Soo;Chung, Sun Ok;Choi, Chang Hyun;Cho, Jong Seung;Choi, Dug Soon;Kim, Young Joo;Lee, Sang Dae;Hong, Soon Jung;Kim, Yong Joo;Koo, Seung Mo
    • Journal of Biosystems Engineering
    • /
    • v.41 no.4
    • /
    • pp.313-318
    • /
    • 2016
  • Purpose: This study measured and analyzed the PTO (power take off) torque of a transplanter according to the planting conditions during field operation. Methods: A torque measurement system was constructed with torque sensors to measure the torque of a PTO shaft, a measurement device to acquire sensor signals, and a power controller to provide power for a laptop computer. The field operation was conducted at four planting distances (26, 35, 43, and 80 cm) and two planting depths using the transplanter on a field with similar soil conditions. One-way ANOVA with planting distance and Duncan's multiple range test at a significance level of 0.05 were used to analyze the PTO torque. The torque ratio was calculated based on the minimum torque using the average PTO torque measured under each planting condition. Results: The average torques on the PTO shaft for planting distances of 26, 35, 43, and 80 cm at a low planting depth were 11.05, 9.07, 7.04, and 3.75 Nm, respectively; the same for planting distances of 26, 35, 43, and 80 cm at a middle planting depth were 12.20, 9.86, 7.94, and 4.32 Nm, respectively. When the planting distance decreased by 43, 35, and 26 cm, the torque ratio at a low planting depth increased by 88, 142, and 195%, respectively. When the planting distance decreased by 43, 35, and 26 cm, the torque ratio at the middle planting depth increased by 84, 128, and 182%, respectively. Conclusions: PTO torque fluctuated by planting distance and depth. Moreover, the PTO torque increased for short planting distances. Therefore, farmers should determine the planting conditions of the transplanter by considering the load and durability of the machine. The results of this study provide useful information pertaining to the optimum PTO design of the transplanter considering the field load.

Analysis of Potential on Measurement of SO2 and NO2 using Radiative Transfer Model and Hyperspectral Sensor (복사전달모델과 초분광센서를 이용한 아황산가스와 이산화질소의 농도 측정 가능성 분석)

  • Shin, Jung-il;Kim, Ik-Jae;Choi, Min-Jae;Lim, Seong-Ha
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.6
    • /
    • pp.658-663
    • /
    • 2018
  • Current measuring methods for air quality are based on ground measurement networks and satellite data. New methods of collecting evidence with advanced sensors are needed because current methods have limitations in collecting evidence for the illegal emission of air pollutants at narrow areas or specific sites. This study analyzed the possibility of using an ultraviolet hyperspectral sensor to measure the concentration of nitrogen dioxide and sulfur dioxide. Two types of spectra were used: simulated spectra for gases with various concentrations using a radiative transfer model and observed spectra for each gas for a concentration. To understand the possibility of using a hyperspectral sensor, the differences between the simulated spectra and the observed spectra were analyzed, and the variation of simulated spectra were then analyzed according to the concentration. The results showed good agreement between observed spectra and simulated spectra. In addition, the absorption depth at specific wavelengths in the simulated spectra had a very strong correlation with the gas concentration. The gas concentration could be estimated using the hyperspectral sensor. In the future, validation would be needed to estimate the gas concentration through observations of various concentrations of gases using a hyperspectral sensor.