• Title/Summary/Keyword: Depletion parameter

Search Result 30, Processing Time 0.029 seconds

Assessment of Snowmelt Impact on Chungju Dam Watershed Inflow Using Terra MODIS Data and SWAT Model (Terra MODIS 위성영상과 SWAT 모형을 이용한 융설이 충주댐 유입량에 미치는 영향 평가)

  • Kim, Saet Byul;Ahn, So Ra;Shin, Hyung Jin;Kim, Seong Joon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.34 no.2
    • /
    • pp.457-467
    • /
    • 2014
  • This study is to evaluate the snowmelt impact on dam inflow for the Chungju Dam watershed $6,642.0km^2$ using Terra MODIS (Moderate-Resolution Imaging Spectroradiometer) and Soil and Water Assessment Tool (SWAT). To determine the SWAT snowmelt parameter; snow cover depletion curve (SCDC) the snow depth distribution (SDD) using Terra MODIS was used, the snow depth was spatially interpolated using snowfall data of ground meteorological stations. For 10 sets (2000-2010) data during snowmelt period (November-April), the sno50cov parameter, that is, the 50% coverage at a fraction of SCDC which determines the shape of snow depletion process, showed the values of 0.4 to 0.7. The SWAT model was calibrated with average $R^2$ of 0.54 using the sno50cov of each year. The 10 years average streamflow during snowmelt period was 104.3 mm which covers 12.0% of the annual streamflow.

Sensitivity Analysis of Depletion Parameters for Heat Load Evaluation of PWR Spent Fuel Storage Pool (경수로 사용후핵연료 저장조 열부하 평가를 위한 연소조건 인자 민감도 분석)

  • Kim, In-Young;Lee, Un-Chul
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.9 no.4
    • /
    • pp.237-245
    • /
    • 2011
  • As necessity of safety re-evaluation for spent fuel storage facility has emphasized after the Fukushima accident, accuracy improvement of heat load evaluation has become more important to acquire reliable thermal-hydraulic evaluation results. As groundwork, parametric and sensitivity analyses of various storage conditions for Kori Unit 4 spent fuel storage pool and spent fuel depletion parameters such as axial burnup effect, operation history, and specific heat are conducted using ORIGEN2 code. According to heat load evaluation and parametric sensitivity analyses, decay heat of last discharged fuel comprises maximum 80.42% of total heat load of storage facility and there is a negative correlation between effect of depletion parameters and cooling period. It is determined that specific heat is most influential parameter and operation history is secondly influential parameter. And decay heat of just discharged fuel is varied from 0.34 to 1.66 times of average value and decay heat of 1 year cooled fuel is varied from 0.55 to 1.37 times of average value in accordance with change of specific power. Namely depletion parameters can cause large variation in decay heat calculation of short-term cooled fuel. Therefore application of real operation data instead of user selection value is needed to improve evaluation accuracy. It is expected that these results could be used to improve accuracy of heat load assessment and evaluate uncertainty of calculated heat load.

Compact Gate Capacitance Model with Polysilicon Depletion Effect for MOS Device

  • Abebe, H.;Morris, H.;Cumberbatch, E.;Tyree, V.
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.7 no.3
    • /
    • pp.209-213
    • /
    • 2007
  • The MOS gate capacitance model presented here is determined by directly solving the coupled Poisson equations on the poly and silicon sides, and includes the polysilicon (poly) gate depletion effect. Our compact gate capacitance model exhibits an excellent fit with measured data and parameter values extracted from data are physically acceptable. The data are collected from 0.5, 0.35, 0.25 and $0.18{\mu}m$ CMOS technologies.

Extraction of Snowmelt Parameters using NOAA AVHRR and GIS Technique for 5 River Basins in South Korea (NOAA AVHRR 영상 및 GIS 기법을 이용한 국내 5대강 유역의 융설 매개변수 추출)

  • Shin, Hyung-Jin;Park, Geun-Ae;Kim, Seong-Joon
    • Korean Journal of Remote Sensing
    • /
    • v.23 no.2
    • /
    • pp.119-124
    • /
    • 2007
  • The few observed data related snowmelt was the major cause of difficulty in extracting snowmelt factors such as snow cover area, snow depth and depletion curve. Remote sensing technology is very effective to observe a wide area. Although many researchers have used remote sensing for snow observation, there were a few discussions on the characteristics of spatial and temporal variation. Snow cover maps were derived from NOAA AVHRR images for the winter seasons from 1997 to 2006. Distributed snow depth was mapped by overlapping between snow cover maps and interpolated snowfall maps from 69 meteorological observation stations. Model parameters (Snow Cover Area: SCA, snow depth, Snow cover Depletion Curve: SDC) building for 5 major watersheds in South Korea. Especially SDC is important parameter of snowmelt model.

A study on Weibull Probability Statistics Characteristics for Vickers Hardness of Degraded Stainless Steel (열화된 스테인리스강의 비커스 경도에 대한 와이블 확률 통계 특성에 관한 연구)

  • Nam, Ki-Woo;Cho, Sung-Duck;Kim, Seon-Jin;Ahn, Seok-Hwan
    • Journal of Power System Engineering
    • /
    • v.21 no.5
    • /
    • pp.79-85
    • /
    • 2017
  • Vickers hardness is an important material in the design and reliability is required. Therefore, these values are very important as the basic data for design, manufacture and development, and the identification of quantitative probability distribution characteristics such as mean and dispersion is a very important parameter in design. In this study, Vickers hardness was measured after artificially heat-treated in the temperature range 753K, where chrome depletion near the grain boundary occurred for three kinds of stainless steels, and the Vickers hardness were evaluated. From the results, Vickers hardness increased with increasing heat treatment temperature. In Weibull distribution for Vickers hardness, the dispersion of STS310S at 813K and 873K was small, and the dispersion of STS316L at 753K, 933K and 993K was small. Also, STS347H exhibited the lowest dispersion at 753K in three kinds of stainless steels. The scale parameter increased with increasing heat treatment temperature in three kinds of stainless steels.

Condensation Heat Transfer Characteristics of HCFC - 123 inside Horizontal Smooth Tube (HCFC-123의 수평 평활관내 응축 전열 특성에 관한 연구)

  • 권옥배;오후규;오종택;김성규
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.17 no.3
    • /
    • pp.24-32
    • /
    • 1993
  • Experimental data on the heat transfer characteristics of HCFC-123 and CFC-11 during condensation in horizontal smooth tube are presented. The experimental apparatus consisted of a closed working fluid loop, coolant loop, and measuring system. The major components of the working fluid loop made of a refrigerant pump, boiler, superheater, refrigerant flow meter, receiver and test section. The tube-in-tube type test section was made of smooth tube which were constructed form 9.52 mm outer diameter of smooth copper tube with 50 mm outside diameter of PVC tube duct. The ranges of parameter, such as refrigerant mass velocity, coolant flow rate, and quality were 90-325kg/($m^2$.s), 60-360kg/h, 5-95% respectively. Data were obtained under steady state condition for annular flow. As a result of these, the condensation heat transfer coefficients for HCFC-123 were slightly lower than those of CFC-11 from 8% to 15% inside horizontal smooth tube. Furthermore, a new generalized correlation for the heat transfer coefficients of HCFC-123 and CFC-11 during condensation inside horizontal smooth tube is proposed.

  • PDF

Scale-up of Flat Panel Photobioreactor considering Hydrodynamics (수력학을 고려한 평판형 광생물 반응기의 스케일업에 관한 연구)

  • Kim, Gwang-Ho;Lee, Dong-Woon;Jeong, Sang-Hwa
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.17 no.1
    • /
    • pp.48-56
    • /
    • 2018
  • Due to the growing concerns of energy resource depletion and environmental destruction, the mass production of microalgae has been studied. The scale-up of a photobioreactor (PBR) is required for the mass production of biomass. In this paper, the geometric parameters and oxygen transfer rate (OTR) are considered, to scale up a flat panel photobioreactor (FP PBR). The PBR is designed using the goal-driven optimization (GDO) method to accomplish the scale-up. The local sensitivity of each output parameter with respect to the input parameter is analyzed through the design of experiment (DOE), and the design candidates are evaluated with the screening sampling method. The volumetric mass transfer coefficient is measured by the dynamic method.

Comparison of Alternate Approaches for Reversible Geminate Recombination

  • Khokhlova, Svetlana S.;Agmon, Noam
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.3
    • /
    • pp.1020-1028
    • /
    • 2012
  • This work compares various models for geminate reversible diffusion influenced reactions. The commonly utilized contact reactivity model (an extension of the Collins-Kimball radiation boundary condition) is augmented here by a volume reactivity model, which extends the celebrated Feynman-Kac equation for irreversible depletion within a reaction sphere. We obtain the exact analytic solution in Laplace space for an initially bound pair, which can dissociate, diffuse or undergo "sticky" recombination. We show that the same expression for the binding probability holds also for "mixed" reaction products. Two different derivations are pursued, yielding seemingly different expressions, which nevertheless coincide numerically. These binding probabilities and their Laplace transforms are compared graphically with those from the contact reactivity model and a previously suggested coarse grained approximation. Mathematically, all these Laplace transforms conform to a single generic equation, in which different reactionless Green's functions, g(s), are incorporated. In most of parameter space the sensitivity to g(s) is not large, so that the binding probabilities for the volume and contact reactivity models are rather similar.

An Analytic Model for Punchthrough Limited Breakdown Voltage of Cylindrical Junctions (Punchthrough 원통형 접합이 항복전압에 대한 해석적 모델)

  • 배동건;정상구
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.36D no.4
    • /
    • pp.70-76
    • /
    • 1999
  • Analytic model for punchthrough limited breakdown voltage of cylindrical junction is presented as a function of the epitaxial layer thickness and the critical depletion width of the cylindrical junction in nonpunchthrough cases. All the expressions for the distances, electric fields and potentials are normalized, allowing quick determination of the corresponding breakdown voltages. The calculated results are in good agreement with the simulations obtained from two dimensional device simulation program MEDICI.

  • PDF

Comparison of Gate Thickness Measurement

  • 장효식;황현상;김현경;문대원
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.197-197
    • /
    • 1999
  • Gate oxide 의 두께 감소는 gate의 캐패시턴스를 증가시켜 트랜지스터의 속도를 빠르게 하며, 동시에 저전압 동작을 가능하게 하기 때문에 gate oxide 두께는 MOS 공정 세대가 진행되어감에 따라 계속 감소할 것이다. 이러한 얇은 산화막은 device design에 명시된 두께의 특성을 나타내야 한다. Gate oxide의 두께가 작아질수록 gate oxide와 crystalline silicon간의 계면효과가 박막의 두께의 결정에 심각한 영향을 주기 때문에 정확한 두께 계측이 어렵다. 이러한 영향과 계측방법에 따라서 두께 계측의 차이가 나타난다. XTEM은 사용한 parameter에, Ellipsometer는 refractive index에, MEIS(Medium) Energy Ion Scattering)은 에너지 분해능에, Capacitor-Voltage 측정은 depletion effect에 의해 영향을 받는다. 우리는 계면의 원자분해능 분석에 통상 사용되어온 High Resolution TEM을 이용하여 약 30~70$\AA$ SiO2층의 두께와 계면 구조에 대한 분석을 하여 이를 MEIS와 0.015nm의 고감도를 가진 SE(Spectroscopy Ellipsometer), C-V 측정 결과와 비교하여 가장 좋은 두께 계측 방법을 찾고자 한다.

  • PDF