Indoor Radon Levels and Effective Dose Estimation in Learning and Common Living Space of University (대학 내 학습공간과 공동 생활공간에 대한 실내 라돈 농도 측정과 유효선량 산출)

  • Kim, Jung-Su
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.3
    • /
    • pp.329-334
    • /
    • 2018
  • Radon which is natural component of air is a colorless and odorless radioactive gas. Radon exposure can also occur from some building materials if they are made from radon-containing substances by breathing. In this study, The radiation dose of radon concentration was detected at 8 buildings of the A university during 3-month from June. 2017 to August. 2017. We detected indoor radon exposure at 8 building of the university and estimated annual effective dose. The radon concentration of Hall G and Hall F of the A university represented 81 and $14Bq/m^3$ respectively and average indoor radon concentration represented $41.63Bq/m^3$. Average effective dose was estimated 0.40 mSv/y, maximum effective dose was 0.78 mSv/y and minimum effective dose was 0.13 mSv/y respectively. University is the place that students spend the almost whole time. We suggest ventilation and appropriate management of a building, which could reduce the natural radiation exposure by radon concentration.

Diagnostic ability of differential diagnosis in ameloblastoma and odontogenic keratocyst by imaging modalities and observers (범랑모세포종과 치성각화낭의 감별 진단시 방사선사진과 판독자에 따른 진단능의 비교)

  • Gang, Tae-In;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-Suk;Lee, Sam-Sun;Kim, Jeong-Hwa;Moon, Je-Woon;Choi, Soon-Chul
    • Imaging Science in Dentistry
    • /
    • v.36 no.4
    • /
    • pp.177-182
    • /
    • 2006
  • Purpose: To evaluate the diagnostic ability in differentiating between ameloblastoma and odontogenic keratocyst according to the imaging modalities and observers. Materials and Methods: We evaluated thirty-six cases of ameloblastomas and forty-seven cases of odontogenic keratocysts all histologically confirmed. Six oral and maxillofacial radiologists diagnosed the lesions by 3 methods: using panoramic radiograph, using computed tomograph (CT), and using panoramic radiograph and CT. The observers were classified by 3 groups: group 1 had experienced over 10 years in oral and maxillofacial radiologic field, group 2 had experienced for 3-4 years, and group 3 was in the process of residentship. After over 2 weeks, the observers diagnosed them by the same methods. Results: The ROC curve areas except for group 3 were the highest with interpretation using panoramic radiograph and CT, followed by interpretation using CT only, and the lowest with interpretation using panoramic radiograph only. The overall difference was not found in diagnostic ability among groups in using panoramic radiograph only, but there was difference in diagnostic ability of group 1 and 2 vs 3 in using CT only, and combination panoramic radiograph and CT. Conclusions: To differentiate between ameloblastoma and odontogenic keratocyst more accurately, the experienced oral and maxillofacial radiologist should diagnose with combination of panoramic radiograph and CT.

  • PDF

Morphological Changes of Mouse Ovary by X-Ray Irradiation (방사선 조사선량에 따른 생쥐 난소의 형태학적 변화)

  • Yoon, Chul-Ho;Choi, Jong-Woon;Yoon, Surk-Hwan
    • Journal of Radiation Protection and Research
    • /
    • v.32 no.4
    • /
    • pp.140-156
    • /
    • 2007
  • This research was performed to investigate the morphological changes of folliculus ovary according to the radiation dose. The whole body radiation of 200 cGy, 400 cGy, and 600 cGy was given to the each groups of 5 months-aged female mouse. Various staining methods used in this research are: Hematosylin-Eosin method, and immunohistochemistrical methods using BrdU, TUNEL, p53, p21, PCNA and inhibin. The minute structural changes of folliculus ovary were observed through an electron microscope with high magnification. The morphological changes of growing folliculus ovary became distinct as the dose of X-rays increased. Especially, the nuclei of granular cells showed manifest condensation and the changes of the transparent zone were distinct. As a result of histochemical reaction according to Masson's trichrome method and reticular fiber method, the changed granular cells, the deformed basilar membrane of folliculus ovary and the abnormal arrangement of the reticular fiber were observed. In the reaction of BrdU, the granular cells of normal folliculus ovary with positive reaction rapidly decreased according to the increase of the dose of X-rays. In TUNEL study, granular cells showing positive reaction in retarded folliculus ovary were expanded to growing folliculus ovary and primordial folliculus ovary according to the increase of the dose of X-rays. In case of 600 cGy of X-rays, oocyte underwent apoptosis. In p53 immunohistochemistry, p53 manifested to be stronger as the dose of X-rays increased. p53 reactivity was manifested distinctively in all cells comprising folliculus ovary following irradiation of 600 cGy. p21 was manifested in granular cells of folliculus ovary and showed very positive reaction around follicular antrum according to the increase of the dose of X-rays. In PCNA, positive reaction was manifested in growing folliculus ovary, mature folliculus ovary and primordial folliculus ovary, but the extent of the reaction decreased as the dose of the X-rays decreased. The finding that the reaction of granular cells around folliculus ovary was stronger than that near follicular membrane indicates that what was damaged first by X-ray was the cells near folliculus ovary and follicular antrum. The reactivity of $inhibin-{\alpha}$ showed difference according to the growing stage of folliculus ovary: $inhibin-{\alpha}$ showed the most strong reaction in mature folliculus ovary with follicular antrum. There was strong reaction in granular cells around follicular membrane but $inhibin-{\alpha}$ did not occur at all in theca cells comprising follicular membrane. $Inhibin-{\alpha}$ in ovary tissue exposed to 400 cGy of X-rays was manifested more strongly than in ovary tissue exposed to 600 cGy of X-rays, which was related to the phenomenon that granular cells of mature folliculus ovary underwent necrosis or apoptosis increasingly due to X-rays. In an electron microscope with high magnification, nuclei and protoplasm of granular cells in growing folliculus ovary abruptly underwent minute structural changes according to the increase of dose of X-rays. Cell residue, by-product of cell decease, neutrophil and macrophage around follicular antrum were observed. The minute structural changes in granular cells showed typical characteristics of apoptosis: the increase of electronic density due to nuclear condensation, fragmentation of nuclei and atrophy of protoplasm. Necrosis of cells was identified but it was not so remarkable. Macrophage with apoptotic bodies was scattered. Proportional to the radiation dose, we found that the generation of heterogeneous substance of normal ovary texture's follicular fluid, the emergence of dyeing characteristic in the basilar membrane of folicle, the generation of apoptosis, and the transformation of macrophages, etc. From this results, we can infer the possible radiation hazard on the ovary of cervix cancer patient with radiation therapy.

Amendment of the Inspection Standard for Diagnostic Radiation Equipment Applying IEC 60601-1-3: Medical Electrical Equipment - Part 1-3: General Requirements for Basic Safety and Essential Performance - Collateral Standard: Radiation Protection in Diagnostic X-ray Equipment (KS C IEC60601-1-3: 의료용 전기기기-제1-3부: 기본 안전 및 필수 성능에 관한 일반 요구사항-보조표준: 진단용 X선 장치의 방사선 방어를 적용한 진단용 방사선 발생장치의 검사기준 개선안)

  • Park, Hye-Min;Kim, Jung-Min;Kim, Jung-Su;Kim, Seong-Ok;Choi, Young-Min
    • Journal of radiological science and technology
    • /
    • v.41 no.5
    • /
    • pp.493-504
    • /
    • 2018
  • The diagnostic radiation equipment is managed in accordance with the "Rules for Safety Management of Diagnostic Radiation Equipment" enacted in 1995. The equipments should be inspected before use and every three years after use in accordance with the [Appendix 1] of the same rule. The inspection standard has been maintained without particular revision since enacted. But, over the past two decades new types of equipments have been manufactured and used. So, it is necessary to revise [Appendix 1] by making inspection items and inspection standards. In this study, we revised the classification system of equipments and reviewed international standards of IEC 60601 series, IEC 61223 series and AAPM TG 18 On-line Report No.03. And identified the problem of current inspection standards. Through this, we revised, deleted and added the inspection items and inspection standard of each equipment to meet the domestic circumstances. As a result of the study, we reorganized the classification system of equipment which are current classified as 5 classes into 22 classes as X-ray system etc. (7 classes), CT system etc. (5 classes) and Dental X-ray system etc. (10 classes). And then, we developed 70 inspection items for 6 types of equipments according to the reorganized classification system of equipments. The inspection items and inspection standards derived from this study have been proposed to the KCDC and will be applied to the revision of the Rule's [Appendix 1]. Therefore, we expect to be used as reference materials for domestic medical center, inspection institutions, and equipment manufacturing import companies.

Study on the hard tissue changes in osteomyelitis of the jaws using CT image (CT 영상을 이용한 악골 골수염의 경조직 변화에 관한 연구)

  • An, Chang-Hyeon;Choi, Bo-Ram;Huh, Kyung-Hoe;Lee, Won-Jin;Lee, Sam-Sun;Choi, Soon-Chul
    • Imaging Science in Dentistry
    • /
    • v.39 no.3
    • /
    • pp.163-168
    • /
    • 2009
  • Purpose : To assess the clinical findings and hard tissue changes of osteomyelitis of the jaws using computed tomographic (CT) image analysis. Materials and Methods : We reviewed and interpreted the CT images of 163 patients (64 males and 99 females, age range from 10 to 87 years) who visited the Seoul National University Dental Hospital from April 23, 2006 to December 31, 2008 and were diagnosed as osteomyelitis of the jaws through clinical, radiologic, and histopathologic examination. Each CT findings was investigated for frequency, correlation with age and gender. Results : Of the 163 patients, 31 (19.0%) were affected on the maxilla, 135 (82.8%) were affected on the mandible, and 3 (1.8%) were affected on the both jaws simultaneously. The mean age of the patients who were affected on the maxilla was 61.0 years and that of the patients who were affected on the mandible was 56.2 years. On the maxilla, the most frequent site of disease was the posterior area (83.9%) and on the mandible, mandibular body (83.0%), followed by angle (48.1%), ramus (38.5%), condyle (13.3%), incisal area (9.6%), and coronoid process (3.0%). Among the 31 maxillary osteomyelitis, defect in the trabecular bone was observed in 28 (90.3%), osteosclerosis 20 (64.5%), defect in the cortical bone 27 (87.1%), sequestrum 17 (54.8%), and periosteal reaction 2 (6.5%). Among the 135 mandibular osteomyelitis, defect in the trabecular bone was observed in 100 (74.1%), osteosclerosis 104 (77.0%), defect in the cortical bone 116 (85.9%), sequestrum 36 (26.7%), and periosteal reaction 67 (49.6%). Conclusion : Of our cases, the maxillary osteomyelitis was visibly observed more frequently in females than males. The incidence is the highest in seventies (28.8%) and the lowest in teens (3.1%). The osteomyelitis of the jaws was observed more frequently in males than females before the age of 50, and observed more frequently in females after the age of 50. The most noticeable point was that the sequestrum was observed more often on maxillary osteomyelitis and the periosteal reaction was observed more often on mandibular osteomyelitis.

  • PDF

T2 Relaxation Times of the Cingulate Cortex, Amygdaloid Body, Hippocampal Body, and Insular Cortex: Comparison of 1.5 T and 3.0 T (대상회 피질, 편도체, 해마체, 도피질의 T2 이완시간: 1.5테슬러와 3.0테슬러 자기공명영상장치의 비교)

  • Lee, Ho-Joon;Kim, Eung-Yeop
    • Investigative Magnetic Resonance Imaging
    • /
    • v.15 no.1
    • /
    • pp.67-71
    • /
    • 2011
  • Purpose : To compare T2 relaxation times (T2) in the cingulate cortex, amygdaloid body, hippocampal body, and insular cortex between 1.5T and 3.0T MR imagers. Materials and Methods : Twelve healthy volunteers underwent FLAIR and CPMG imaging perpendicular to the hippocampal body at both 3.0T and 1.5T. T2 was measured in the cingulate cortex, amygdaloid body, hippocampal body, and insular cortex. The T2 relaxation time ratios of the cingulate cortex, insular cortex, and amygdaloid body to the hippocampal body were compared between 1.5T and 3.0T. Results : The mean T2 of the cingulate cortex, amygdaloid body, hippocampal body, and insular cortex at 1.5T were $109.5{\pm}3.1$, $117.0{\pm}7.1$, $114.7{\pm}2.4$, and $111.3{\pm}2.4$, respectively; $99.7{\pm}3.8$, $100.7{\pm}4.3$, $97.9{\pm}3.4$, and $96.2{\pm}2.0$, respectively, at 3.0T. Percentage changes of T2 in the cingulate cortex, insular cortex, amygdaloid body, and hippocampal body at 3.0T with respect to those at 1.5T were -8.9%, -13.5%, -14.6%, and -13.5%, respectively. The mean T2 ratios of the cingulate gyrus, insular cortex, and amygdaloid body to the hippocampal body at 1.5T and 3.0T were 0.96 and 1.02 (p = 0.003); 1.02 and 1.03 (p>0.05); 0.97 and 0.98 (p>0.05), respectively. Conclusion : T2 decrease in the cingulate cortex was less than the amygdaloid body, insular cortex, and hippocampal body at 3.0T. The mean T2 ratio of the cingulate gyrus to the hippocampal body was significantly different between 1.5T and 3.0T.

A Study on the Surface Dose Distribution by Scattered and Leakage Radiation in Radiation Therapy (방사선 치료 시 산란선 및 누설선에 의한 표면선량 분포에 관한 연구)

  • Kang, Jongsu;Jung, Dongkyung;Kim, Yongmin
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.3
    • /
    • pp.351-357
    • /
    • 2018
  • During radiation therapy, the patient is exposed to secondary radiation by scattered and leakage radiation. For the diagnostic radiation, guidelines for reducing the patient's exposure as the diagnostic reference level are provided. However, in the case of therapeutic radiation, even though the radiation dose by the secondary radiation is considerable, the prescription dose is not limited because of the reason of the therapeutic efficiency. The purpose of this study was to evaluate the secondary radiation that the patient could be received at the peripheral tissue during the radiotherapy using the linear accelerator with the radiophotoluminescent glass dosimeter. In addition, we measured the degree of saturation of the luminescent amount according to the build-up characteristic of the radiophotoluminescent glass dosimeter. As a result of carrying out this study, the exposure dose decreased drastically farther away from the treatment field. When the head was irradiated with 1 Gy, the neck could be exposed to 18.45 mGy. When the same dose was irradiated at the neck, 15.55 mGy of the head and irradiated at the chest, 14.26 mGy of the neck and irradiated at the pelvis, 1.14 mGy of the chest were exposed separately. The degree of saturation of the luminescent intensity could be overestimated by 1.8 ~ 4.8% depending on time interval for 3 days.

Analysis of Twinkling Artifacts Caused by Kidney Stones on Abdominal Ultrasound (복부 초음파 검사에서 신장결석으로 인해 발생되는 Twinkling 인공물에 관한 분석)

  • Kim, Ju-Hee;Jang, Hyon-Chol;Cho, Pyong-Kon
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.5
    • /
    • pp.637-642
    • /
    • 2021
  • Kidney stones are largely classified into kidney stones, ureter stones, and urolithiasis depending on the location of their occurrence. Therefore, in this study, from January 2019 to June 2021, kidney stones found in 112 patients with flank pain or who visited for abdominal ultrasonography at a general hospital located in Daegu were diagnosed with urolithiasis. We wanted to investigate the effect on twinkling artifacts. As a result of the study, the incidence of twinkling artifacts due to kidney stones was relatively high in the longitudinal scan among the scan methods. As the number of kidney stones increased, the incidence of twinkling artifacts increased by 1.296 times (p<0.05). As the kidney stone size increased, the incidence of twinkling artifacts increased by 0.086-fold (p<0.05). It was found that the number and size of kidney stones are factors affecting twinkling artifacts. Since the effect of kidney stones on twinkling artifacts is related to the number and size of kidney stones, continuous attention should be paid to helping the detection of kidney stones by using variables affecting twinkling artifacts.

The Associated Factors of Protective Behaviors for Radiation Exposure based on Health Belief Model Honam Province Radiologic Technologists (건강신념모델을 적용한 호남지역 방사선사의 방사선 방어행위 수행도 관련 요인)

  • Yoon, Yo-Sang;Ryu, So-Yeon;Park, Jong;Choi, Seong-Woo;Oh, Hye-Jong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.3
    • /
    • pp.96-107
    • /
    • 2020
  • This study aimed to identify the associated factors of protective behaviors for radiation exposure among some radiology technologists using the Health Belief Model. The subjects of the study were 541 radiology technologists working at hospitals or clinics in Honam Province. Using the SPSS version 18.0 program, data were analyzed using a t-test, ANOVA, Pearson's correlation analysis, and hierarchical multiple logistic regression analysis. To modify the factors, the performance of subjects who had a higher level of education and nuclear medicine rooms were higher than those who worked in simple radiography rooms. The radiation protective behaviors performance of the subjects who had more exercise, medium-level stress, and worked in higher-quality protection facilities was higher. Regarding the personal perceptions, the cues to action (β=.292, p=.0001), and perceived seriousness (β =.075, p=.010) were factors that had effects on the performance of radiation protection behaviors. Regarding the likelihood of action, the benefits (β=.168, p<.0001), self-efficacy (β=.148, p=.007), and the performance of protective behaviors were higher. In conclusion, protection education as a cue to action should be provided to stimulate protective behaviors, and the benefits of protective behaviors should be emphasized. To increase the performance of protection behaviors, self-efficacy should be enhanced, and the subjects are offered appropriate information that helps perceive seriousness.

Analysis of Liver Elasticity according to Ultrasound Findings (초음파 소견에 따른 간 탄성도 분석)

  • Chun, Hye-Ri;Jang, Hyon-Chol;Cho, Pyong-Kon
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.6
    • /
    • pp.883-889
    • /
    • 2021
  • This study was conducted on 101 patients who visited hospital for abdominal ultrasonography from May 2020 to December 2020. The purpose of this study was to find out the elasticity according to the ultrasound images (echo pattern, splenomegaly, hepatitis) during the ultrasound examination using the shear wave elastography. The shear wave elastography value of the normal group of the echo pattern was 5.75±1.58 kPa, and the group with the abnormal echo pattern was 8.84±4.94 kPa, and the shear wave elastography value of the abnormal group was high (p<0.05). In normal spleen size, hepatic elasticity value was 6.33±2.54 kPa, and hepatic elasticity value of splenomegaly was 13.73±5.48 kPa. In the case of splenomegaly, the liver elasticity value was high, and there was a statistically significant difference (p<0.05). As the spleen size increased, the liver elasticity value increased by 1.485 times, and as hepatitis progressed, the liver elasticity value increased by 1.573 times (p<0.05). As a result of analysis of concordance between ultrasound imaging findings and shear wave elastography, the Kappa value was found to be as high as 0.922 (p<0.05), which showed high concordance between the two test methods. Additional comparisons of liver elasticity values in shearwave elastography tests along with liver ultrasound findings are thought to be of great help in diagnosing liver fibrosis.