• Title/Summary/Keyword: Department of Radiography

Search Result 1,480, Processing Time 0.031 seconds

Evaluation of the Patient Dose in Case of Standard Radiographic Examinations Using CR and DR (표준영상의학검사를 대상으로 한 CR과 DR에서의 환자선량평가)

  • Kim, Sang-Tae;Han, Beom-Hui
    • Journal of radiological science and technology
    • /
    • v.33 no.3
    • /
    • pp.173-178
    • /
    • 2010
  • In projection radiography, two types of digital imaging systems are currently available, computed radiography (CR) and digital radiography (DR): a difference between them can be stated in terms of dose and image quality. In the Department of Radiology our hospital, a flat-panel DR equipment (Digital diagnost, Philips) and two CR systems (ADC Compact plus digitizer, AGFA) are employed. Eight standard radiographic examinations (Skull AP, Skull LAT, Chest PA, Chest LAT, Abdomen AP, L-spine AP, L-spine LAT, Pelvis AP) were considered: doses delivered to patients in terms of both entrance skin dose (ESD) were calculated and compared in order to study the dosimetric discrepancies between CR and DR. Assessment of image quality is undertaken by Consultant Radiologists to ensure that the quality criteria for diagnostic radiographic images of the European guidelines were met. Results showed that both ESD in DR are lower than that in CR; all images met the criteria in the European Guidelines for both modalities and were used for reporting by the radiologists. Since the operators are the same and the image quality is comparable in both modalities, this study shows that in the considered examinations, DR can perform better than CR from a dosimetric point of view.

STUDY ON ENTRANCE SKIN DOSE AT PANORAMIC RADIOGRAPHY IN INCHEON, KOREA

  • Choi, Jung-Hyun;Kim, Sung-Chul;Han, Dong Kyoon
    • Journal of Radiation Protection and Research
    • /
    • v.39 no.4
    • /
    • pp.182-186
    • /
    • 2014
  • Recently, the use of panoramic radiography has shown a constant increase, and significant research is underway. However, radiation exposure attracts less attention in dental radiography than in other types of radiography. We used an OSLD for measurement of the entrance skin dose in eyeballs and the thyroid region, both of which are not covered by examinations but are included in radiographical regions and are sensitive to radiation, as well as orally in Incheon and reported the results. The entrance skin dose was 0.0282 mSv on average for the oral region, and 0.0259 mSv on average for the eyeball, and 0.0261mSv on average, for thyroid gland. While there is no proper shielding method for the eyeball, a thyroid protector is not used by most hospitals and most hospitals are equipped with an apron and a thyroid protector separately; thus, it is necessary to use an integration of an apron and a thyroid protector and medical device manufacturers need to develop a method for controlling the length of the slit in the slit-type area of radiation occurrence in order to reduce unnecessary exposure.

A Quality Assurance on Digital Chest Radiography in Medical Institution for Pneumoconiosis : Compared with Analog Radiography (진폐요양기관의 흉부 디지털촬영과 아날로그촬영의 정도관리 비교)

  • Lee, Won-Jeong;Ko, Kyung-Sun;Park, Jai-Soung;Kim, Sung-Jin;Chu, Sang-Deok;Park, So-Young;Choi, Byung-Soon
    • Journal of radiological science and technology
    • /
    • v.33 no.2
    • /
    • pp.85-91
    • /
    • 2010
  • Digital radiography has been replacing rapidly the analog radiography for diagnosis of pneumoconiosis. The purpose of this study is to compare quality control of digital radiography (DR) and analog radiography (AR) for chest radiography in medical institution for pneumoconiosis (MIP) For the first time, we visited MIP to evaluate the chest radiography which is used for patients with pneumoconiosis, including equipment, technical parameters and reading environment. There were 33 institutions. DR and AR were installed in 24 and 9 institutions, respectively. Between DR and AR, we compared the radiological technique (RT), image quality (IQ) and reading environment (RE) to use the guideline published by Occupational Safety and Health Research Institute (OSHRI). The image quality was rated by two experienced chest radiologists for pneumoconiosis with certified from OSHRI. The chest radiography equipment was not significantly difference between AR and DR, but there were significantly difference in tube voltage and grid ratio used for chest radiography except to tube current, exposure time. Statistically, DR is significantly higher in RT(70.3 vs. 43.8, p = 0.009), RE(77.7 vs. 33.3, p = 0.004) than AR, but it's not significantly difference in IQ (65.6 vs. 52.8, p = 0.050). AR and DR in RT were passed 33.3%, 75.0% respectively (p = 0.044) and 44.4%, 79.2% (p = 0.090) in IQ and 44.4%, 91.7% (p = 0.009) in RE. In MIP, DR needs to replace AR in diagnosis of pneumoconiosis.

A Study of Usefulness of Panoramic Radiography in Case of Employees' Oral Examination (근로자 구강검진 시 파노라마방사선사진의 필요성에 관한 고찰)

  • Jun, Sung-Hee
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.13 no.2
    • /
    • pp.91-97
    • /
    • 2011
  • This study was conducted to know usefulness of panoramic radiography by comparing clinical evaluation and dental panoramic radiography in case of oral examination. Following results were concluded by analyzing difference between the result of Clinical evaluation and dental panoramic radiography. According to comparison the result of clinical evaluation and panoramic radiography, In Shin's research, dental caries was higher by 23.1%, periodontal disease was 31.9%, in An's research, dental caries was 24.2%. From new point of view from panoramic radiography, impacted tooth was 33.6%, Sinus abnormalities was 11.6%, periapical lesion was 5.4% in Shin's research and periapical lesion was 17.4%, 3rd molar impaction was 15.3% and retained root was 5.3% in An's research. Any kind of caries were not found in oral examination in the 66.7% of patients among patients with dental root caries in An's research. There were misdiagnose in oral examination(even side(59.5%),proximal side(59.5%), seconds caries(44.0%).

  • PDF

Investigation of Physical Imaging Properties in Various Digital Radiography Systems (다양한 디지털 방사선 시스템의 물리적 영상 특성 조사)

  • Jeong, Hoi-Woun;Min, Jung-Hwan;Yoon, Yong-Su;Kim, Jung-Min
    • Journal of radiological science and technology
    • /
    • v.40 no.3
    • /
    • pp.363-370
    • /
    • 2017
  • We aimed to evaluate the physical imaging properties in various digital radiography systems with charged coupled device (CCD), computed radiography (CR), and indirect flat panel detector (FPD). The imaging properties measured in this study were modulation transfer function (MTF) wiener spectrum (WS), and detective quantum efficiency (DQE) to compare the performance of each digital radiography system. The system response of CCD were in a linear relationship with exposure and that of CR and FPD were proportional to the logarithm of exposure. The MTF of both CR and FPD indicated a similar tendency but in case of CCD, it showed lower MTF than that of CR and FPD. FPD showed the lowest WS and also indicated the highest DQE among three systems. According to the results, digital radiography system with different type of image receptor had its own image characteristics. Therefore, it is important to know the physical imaging characteristics of the digital radiography system accurately to obtain proper image quality.

Detection of root perforations using conventional and digital intraoral radiography, multidetector computed tomography and cone beam computed tomography

  • Shokri, Abbas;Eskandarloo, Amir;Noruzi-Gangachin, Maruf;Khajeh, Samira
    • Restorative Dentistry and Endodontics
    • /
    • v.40 no.1
    • /
    • pp.58-67
    • /
    • 2015
  • Objectives: This study aimed to compare the accuracy of conventional intraoral (CI) radiography, photostimulable phosphor (PSP) radiography, cone beam computed tomography (CBCT) and multidetector computed tomography (MDCT) for detection of strip and root perforations in endodontically treated teeth. Materials and Methods: Mesial and distal roots of 72 recently extracted molar were endodontically prepared. Perforations were created in 0.2, 0.3, or 0.4 mm diameter around the furcation of 48 roots (strip perforation) and at the external surface of 48 roots (root perforation); 48 roots were not perforated (control group). After root obturation, intraoral radiography, CBCT and MDCT were taken. Discontinuity in the root structure was interpreted as perforation. Two observers examined the images. Data were analyzed using Stata software and Chi-square test. Results: The sensitivity and specificity of CI, PSP, CBCT and MDCT in detection of strip perforations were 81.25% and 93.75%, 85.42% and 91.67%, 97.92% and 85.42%, and 72.92% and 87.50%, respectively. For diagnosis of root perforation, the sensitivity and specificity were 87.50% and 93.75%, 89.58% and 91.67%, 97.92% and 85.42%, and 81.25% and 87.50%, respectively. For detection of strip perforation, the difference between CBCT and all other methods including CI, PSP and MDCT was significant (p < 0.05). For detection of root perforation, only the difference between CBCT and MDCT was significant, and for all the other methods no statistically significant difference was observed. Conclusions: If it is not possible to diagnose the root perforations by periapical radiographs, CBCT is the best radiographic technique while MDCT is not recommended.

Comparison of Non-Destructive Testing Images using $^{192}Ir$ and $^{75}Se$ with Computed Radiography System (Computed Radiography 시스템에 $^{192}Ir$$^{75}Se$ 동위원소를 적용하여 촬영한 비파괴검사 영상 비교)

  • Kang, Sang-Mook;Chol, Chang-Il;Lee, Seung-Kyu;Park, Sang-Ki;Kim, Yong-Kyun
    • Journal of Radiation Protection and Research
    • /
    • v.35 no.1
    • /
    • pp.26-33
    • /
    • 2010
  • A computed Radiography (CR) system by use of reusable Image Plate (IP) offers a convenient and reliable way to replace a conventional film-screen system for NDT (non-destructive testing) field. The quality of a radiography to detect a defect of welded objects depends on the procedure embracing several factors such as measurement conditions, image plate type/class, radiation energy, radiation type, and source to image plate distance. Also, the ability of images to detect a flaw reduces with increasing object thickness. In the study, the properties of gamma ray source were summarized for NDT field and inspection images of CR image system manufactured by FUJI were acquired using $^{75}Se$ and $^{192}Ir$ with welded objects. We analyzed the gray scale of hole defect image by using XCAP image processing program and calculated the image contrast and SNR in definition. Also the sesitivities of image quality indicator(IQI) were calculated for hot and cooling tube image of $^{75}Se$ and $^{192}Ir$.

Evaluation of Image Receptor Characteristics in Computed Radiography System Using Exposure Index in International Electrotechnical Commission (I) (IEC 규정 노출지수를 활용한 디지털 방사선 영상시스템에서의 영상 수용체간 특성평가 (I))

  • Park, Hyemin;Yoon, Yongsu;Roh, Younghoon;Kim, Sungjun;Na, Chanyoung;Han, Taeho;Kim, Jungsu;Jeong, hoiwoun;Kim, Jungmin
    • Journal of radiological science and technology
    • /
    • v.42 no.4
    • /
    • pp.291-299
    • /
    • 2019
  • The International Electrotechnical Commission (IEC) has regulated the definition and requirements of the exposure index (EI). In this study, we calculated the EI of several image receptors in digital radiography system of two different manufacturers according to the method as per IEC, and evaluated the relationship with incident air kerma. To calculate the EI, w e obtained the characteristics curve of each image receptor by increasing the incident air kerma at RQA 3, 5, 7 and 9, respectively. As a result, there was no significant difference in the EI values between different image receptors of the same manufacturer, but EI values of different manufacturer was different despite the same air kerma was incident. Therefore, understanding the characteristics of the digital radiography systems is important in order to use EI as a tool for measuring and managing the radiation dose.

COMPARATIVE STUDY OF DIGITAL AND CONVENTIONAL RADIOGRAPHY FOR THE DIAGNOSTIC ABILITY OF ARTIFICIAL PROXIMAL SURFACE CARIES (디지털방사선사진과 구내방사선사진의 인접면 인공우식진단능에 관한 비교연구)

  • Cho, Young-Gon;Park, Si-Seung
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.2
    • /
    • pp.113-121
    • /
    • 2002
  • Conventional intraoral radiography continues to be the most widely used image modality for the diagnosis of dental caries. But, conventional intraoral radiography has several shortcomings, including the difficulty of exposing and processing intraoral film of consistently acceptable quality. In addition, radiographic retaking that was the result of processing errors, may result in increased discomfort and radiation dose to the patient. Recently, various digital radiographies substitute for conventional intraoral radiography to overcome these disadvantages. The advantages of digital radiography are numerous. One of advantages Is the elimination of processing errors. In addition, the radiation dose for digital system is approximately 20% to 25% of that required for conventional intraoral radiography Another potential advantage of digital imaging is the ability to perform image quality enhancements such as contrast and density modulation, which may increase diagnostic accuracy. The purpose of this study was to compare the diagnostic ability of artificial proximal defects to conventional intraoral radiography, direct digital image(CDX2000HQ$^{\circledR}$) and indirect digital image(Digora$^{\circledR}$). Artificial defects were made in proximal surfaces of 60 extracted human molars using #1/2, #1, #2 round bur. Five dentists assessed proximal defects on conventional intraoral radiography, direct digital image(CDX2000HQ$^{\circledR}$) and indirect digital image(Digora$^{\circledR}$). ROC(Receiver Operating Characteristic) analysis and Two-way ANOVA test were used for the evaluation of detectability, and following results were acquired. 1. The mean ROC area of conventional intraoral radiography, direct digital image(CDX2000HQ$^{\circledR}$) and indirect digital Image(Digora$^{\circledR}$) were 0.6766, 0.7538, 0.6791(Grade I), 0.7176, 0.7594, 0.7361(Grade II), and 0.7449, 0.7608, 0.7414(Grade III), respectively. 2. Diagnostic ability of direct digital image was higher than other image modalities. But, there was no statistically significant difference among other imaging modalities for Grade I, II, III lesion(p>0.05). In conclusion, when direct and indirect digital system are comparable with conventional intraoral radiography. these systems may be considered an alternative of conventional intraoral radiography for the diagnosis of proximal surface caries.

Augmented Reality Technology-based Dental Radiography Simulator for Preclinical Training and Education on Dental Anatomy

  • Gu, Ja-Young;Lee, Jae-Gi
    • Journal of information and communication convergence engineering
    • /
    • v.17 no.4
    • /
    • pp.274-278
    • /
    • 2019
  • It is important that students are provided opportunities to practice their skills in acquiring radiographic images. However, these opportunities are currently limited because of the risk of radiation exposure. To overcome this limitation, a new augmented reality-based radiography simulator was developed that enables students to practice radiographic techniques as part of self-directed learning without time and space constraints. Subsequently, cross-sectional images of a manikin phantom head obtained via computed tomography were reconstructed into a three-dimensional object. An image marker that could be recognized by a mobile device and could allow users to practice dental radiography techniques was devised. The three-dimensional object was augmented to the mobile device; consequently, among 106 stored dental radiographs on the device, a radiograph corresponding to specific imaging conditions was opened when users performed radiographic procedures. This technology could improve dental students' understanding of dental anatomy and contribute to improving their competency in acquiring dental radiographs.