Browse > Article
http://dx.doi.org/10.17946/JRST.2017.40.3.02

Investigation of Physical Imaging Properties in Various Digital Radiography Systems  

Jeong, Hoi-Woun (Department of Radiological Science, Baekseok Culture University)
Min, Jung-Hwan (Department of Radiological technology, Shingu University)
Yoon, Yong-Su (Department of Health Sciences, Graduate School of Medical Sciences, Kyushu University)
Kim, Jung-Min (Department of Health and Environmental Science, College of Health Science, Korea University)
Publication Information
Journal of radiological science and technology / v.40, no.3, 2017 , pp. 363-370 More about this Journal
Abstract
We aimed to evaluate the physical imaging properties in various digital radiography systems with charged coupled device (CCD), computed radiography (CR), and indirect flat panel detector (FPD). The imaging properties measured in this study were modulation transfer function (MTF) wiener spectrum (WS), and detective quantum efficiency (DQE) to compare the performance of each digital radiography system. The system response of CCD were in a linear relationship with exposure and that of CR and FPD were proportional to the logarithm of exposure. The MTF of both CR and FPD indicated a similar tendency but in case of CCD, it showed lower MTF than that of CR and FPD. FPD showed the lowest WS and also indicated the highest DQE among three systems. According to the results, digital radiography system with different type of image receptor had its own image characteristics. Therefore, it is important to know the physical imaging characteristics of the digital radiography system accurately to obtain proper image quality.
Keywords
Digital Radiography; Modulation Transfer Function; Wiener Spectrum; Detective Quantum Efficiency;
Citations & Related Records
Times Cited By KSCI : 7  (Citation Analysis)
연도 인용수 순위
1 Samei E., Flynn M. J., Reimann D. A., "A method for measuring the presampled MTF of digital radiographic systems using an edge test device. Med. Phys", Vol. 25, pp. 102-113, 1998.   DOI
2 Kim J. M., Lee K. S. & Kim Y. H., "Correction Method of Wiener Spectrum (WS) on Digital Medical Imaging Systems", Journal of Radiological Science and Technology, Vol. 32, No. 1, pp. 17-24, 2009.
3 Willis, C. E.,"Quality Improvement in Computed Radiography in Categorical Course in Physics: Technology Update and Quality Improvement of Diagnostic X-ray Imaging Equipment", Radiological Society of North America Publication (RSNA), pp. 153-160, 1996.
4 Jeong H. W., Min J. W., Kim J. M., et al., "Performance Characteristic of a CsI(Tl) Flat Panel Detector Radiography System", Journal of Radiological Science and Technology, Vol. 35, No. 2, pp. 109-117, 2012.
5 Kim, K. W., Jeong, H. W., Min, J. W., et al., "Measurement of Image Quality According to the Time of Computed Radiography System", Journal of Radiological Science and Technology, Vol. 38, No. 4, pp. 365-374, 2015.   DOI
6 Kim, K. W., Jeong, H. W., Min, J. W., et al., "Evaluation of Image Quality for Various Electronic Portal Imaging Devices in Radiation Therapy", Journal of Radiological Science and Technology, Vol. 38, No. 4, pp. 451-461, 2015.   DOI
7 Kim, K. W., Jeong, H. W., Min, J. W., et al., "Evaluation of the Modulation Transfer Function for Computed Tomography by Using American Association Physics Medicine Phantom", Journal of Radiological Science and Technology, Vol. 39, No. 2, pp. 193-198, 2016.   DOI
8 Kim, K. W., Jeong, H. W., Min, J. W., et al., "Evaluation of the Performance Characteristic for Mammography by Using Edge device", Journal of Radiological Science and Technology, Vol. 39, No. 3, pp. 415-420, 2016.   DOI
9 Schaetzing R., "Computed radiography technology", Proceeding of Radiological Society of North America, 10, 2003.
10 KFDA, "A guide for general radiology of the patient dose recommend", 2012.
11 Dobbins J. T., Ergun D.L., Rutz L., et al., "DQE (f) of four generations of computed radiography acquisition devices", Med. Phys., Vol. 22, No. 10, pp. 1581-1593, 1995.   DOI
12 Antonuk L. E., Boudry J., and Huang W., "Demonstration of megavoltage and diagnostic X-ray imaging with hydrogenated amorphous silicon arrays", Med. Phys. Vol. 19, No. 6, pp. 1455-1466, 1992.   DOI
13 Granfors P. R., and Aufrichtig R., "Performance of a $41{\times}41$-cm2 amorphous silicon flat panel X-ray detector for radiographic imaging applications", Med. Phys., Vol. 27, No. 6, pp. 1324-33, 2000.   DOI
14 Finc C., Hallscheidt P. J., and Noeldge G., "Clinical comparative study with a large-area amorphous silicon flat-panel detector: image quality and visibility of anatomic structures on chest radiography", Am. J. Roentgenol, Vol. 178, No. 2, pp. 481-486, 2001.
15 Bacher K., Smeets P., Bonnarens K., et al., "Dose reduction in patients undergoing chest imaging: digital amorphous silicon flat-panel detector radiography versus conventional filmscreen radiography and phosphor-based computed radiography", Am. J. Roentgenol, Vol. 181, No. 4, pp. 923-929, 2003.   DOI
16 ICRU (International Commission on Radiation Units and Measurements) Report No 41, "Modulation Transfer Function of Screen-Film Systems", Bethesda, 1986.
17 IEC (International Electrotechnical Commission) 62220-1, "Medical electrical equipment Characteristics of digital X-ray imaging devices Part 1: determination of the detective quantum efficiency", Geneva, 2003.
18 Fujita H., Tasai D. Y., and Itoh T., "A simple method for determining the modulation transfer function in digital radiography", IEEE Trans Med Imaging, Vol. 11, No. 1. pp. 34-39, 1992.   DOI
19 Jung-Min Kim, "Edge Profile Correction for Modulation Transfer Function on Digital X-ray Imaging System", Journal of Radiological Science and Technology, Vol. 30, No. 3, pp. 251-257, 2007.
20 Jerrold T. B., Anthony S. J., Edwin M. L., et al., "The Essential Physics of Medical Imaging, 3nd ed.", Lippincott Williams & Wilkins, 2011.