Abstract
A computed Radiography (CR) system by use of reusable Image Plate (IP) offers a convenient and reliable way to replace a conventional film-screen system for NDT (non-destructive testing) field. The quality of a radiography to detect a defect of welded objects depends on the procedure embracing several factors such as measurement conditions, image plate type/class, radiation energy, radiation type, and source to image plate distance. Also, the ability of images to detect a flaw reduces with increasing object thickness. In the study, the properties of gamma ray source were summarized for NDT field and inspection images of CR image system manufactured by FUJI were acquired using $^{75}Se$ and $^{192}Ir$ with welded objects. We analyzed the gray scale of hole defect image by using XCAP image processing program and calculated the image contrast and SNR in definition. Also the sesitivities of image quality indicator(IQI) were calculated for hot and cooling tube image of $^{75}Se$ and $^{192}Ir$.
Keywords
Selenium-75; Iridium-192; Non-destructive testing; Computed Radiography;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Peter H. Radiography of welds using selenium 75, Ir 192 and X-rays. 12th Asia-Pacific Conference on NDT 2006.
2 Gregory AM, Peter W. Factors affecting probability of Detection with computed radiography. 17th World conference on Non-destructive Testing 2008.
3 Uwe E, Uwe Z, Klaus B. Strategies for film replacement in radiography. IV Pan American Conference for Non Destructive Testing 2007.
4 http//ie.lbl.gov/education/isotopes.htm.
5 Mark GS. Advanced, Second-Generation Selenium 75 Gamma Radiography Sources. 15th World Conference on Non-destructive Testing 2000.
6 Steven AM. How to evaluate the radiographic performance and long-term stability of a computed radiography system. IV Pan American Conference for Non Destructive Testing 2007.
7 Bruce HH. The physics of medical X-ray imaging. 2th ed. Wisconshin; medical physics publishing, 1991:1-10.