• Title/Summary/Keyword: Department of Radiography

Search Result 1,486, Processing Time 0.033 seconds

Effect of Environmental Change in Radiography Room and Psychological Impact on Young Patients (심리적 안정을 고려한 촬영실 내부 환경변화가 검사에 미치는 영향; 유아 방사선검사의 불안감 해소 중심으로)

  • Kim, Seon-Chil;Seok, Eun-Jo
    • Journal of radiological science and technology
    • /
    • v.30 no.1
    • /
    • pp.61-65
    • /
    • 2007
  • The attempt to enhance the environment of hospitals has increased recently to minimize young patients' anxiety about tests and inspections. This gives more satisfaction with the medical service to kids and young patients. The department of radiology endeavors to improve the conditions of existing radiography rooms to help young patients psychologically feel relaxed. This facilitates the process of inspections. This paper examines the relationship between the environment of radiography rooms and its effect on young patients' state of mind. 94 patients at the age of five were observed before and after the improvement of environment of the hospital. Positive results about the psychological state of the young patients were shown after the change of the environment. The result of this paper gives an idea that the modification of hospital environment has a critical importance to the young patients' psychological state. By this conclusion it may help to improve the quality of the medical service.

  • PDF

MRI and Arthroscopy of Osteochondral Lesion of the Talus which was not visible on Plasin Radiography (단순 방사선 상에서 발견할 수 없었던 거골 골연골 병변의 MRI 소견과 관절경 소견)

  • Lee, Woo-Chun;Shim, Jae-Chan;Choi, Deog-Shin
    • Journal of Korean Foot and Ankle Society
    • /
    • v.6 no.2
    • /
    • pp.195-200
    • /
    • 2002
  • Purpose: To investigate the MRI and arthroscopic findings of osteochondral lesion of the talus which looked normal on plane radiography. Materials and methods: We investigated the MRI and arthroscopic findings of seven osteochondral lesions in which there were no abnormal finding on plane radiography and no cystic changes on MRI. Average age was 31 years(range, 19-43 years). Arthroscopic findings were classified according to the Ferkel's criteria. Results: History of injury was reported in all cases and the average duration from injury to presentation was 4 years and 4 months. Low signal change in T1WI was found in 6 of 7 lesions, no signal change in 1 case. Low signal change in T2WI was found in 4, no signal change in 3. 6 STIR images were obtained. High signal change was found in 3, no signal change in 2 and intermediate signal change was in 1. Arthroscopic grading was A in 1, C in 1, D in 2 , E in 1 and F in 2. We could not find any correlation between the findings on MRI and arthroscopic examination. Conclusion: We suggest arthroscopic examination is needed for accurate diagnosis of the osteochondral lesions of the talus which looked normal on plane radiography, because they have various MRl findings and high likelihood of existence of unstable cartilage lesions.

  • PDF

Proposed Institutional Diagnostic Reference Levels in Computed and Direct Digital Radiography Examinations in Two Teaching Hospitals

  • Emmanuel Gyan;George Amoako;Stephen Inkoom;Christiana Subaar;Barry Rahman Maamah
    • Journal of Radiation Protection and Research
    • /
    • v.48 no.1
    • /
    • pp.9-14
    • /
    • 2023
  • Background: The detectors of both computed radiography (CR) and direct digital radiography (DR) have a wide dynamic range that could tolerate high values of exposure factors without an adverse effect on image quality. Therefore, this study aims to assess patient radiation dose and proposes institutional diagnostic reference levels (DRLs) for two teaching hospitals in Ghana. Materials and Methods: CR and DR systems were utilized in this study from two teaching hospitals. The CR system was manufactured by Philips Medical Systems DMC GmbH, while the DR system was manufactured by General Electric. The entrance skin doses (ESDs) were calculated using the standard equation and the tube output measurements. Free-in-air kerma (µGy) was measured using a calibrated radiation dosimeter. The proposed institutional DRLs were estimated using 75th percentiles values of the estimated ESDs for nine radiographic projections. Results and Discussion: The calculated DRLs were 0.4, 1.6, 3.4, 0.5, 0.4, 1.1, 1.0, 1.2, and 1.7 mGy for chest posteroanterior (PA), lumbar spine anteroposterior (AP), lumbar spine lateral (LAT), cervical spine AP, cervical spine LAT, skull PA, pelvis AP, and abdomen AP, respectively in CR system. In the DR system, the values were 0.3, 1.6, 3.1, 0.4, 0.3, 0.7, 0.6, 0.9, and 1.3 for chest PA, lumbar spine AP, lumbar spine LAT, cervical spine AP, cervical spine LAT, skull PA, pelvis AP, and abdomen AP, respectively. Conclusion: Institutional DRLs in nine radiographic projections have been proposed for two teaching hospitals in Ghana for the first time. The proposed DRLs will serve as baseline data for establishing local DRLs in the hospitals and will be a valuable tool in optimizing patient doses.

Evaluation of Unexposed Images after Erasure of Image Plate from CR System (CR 시스템에서 IP 잠상의 소거 후 Unexposed Image의 평가)

  • Lim, Bo-Yeon;Park, Hye-Suk;Kim, Ju-Hye;Park, Kwang-Hyun;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.20 no.4
    • /
    • pp.199-207
    • /
    • 2009
  • It is important to initialize Image Plate (IP) completely for removing residual latent image by sodium lamp for reliability and repeatability of computed radiography (CR) system. The purpose of this study was to evaluate latent images of computed radiography (CR) images respect to delay time after erasure of foregone latent image and its effect, and erasure level. Erasure thoroughness for CR acceptance test from American Association of Physicist in Medicine (AAPM) Report 93 (2006) was also evaluated. Measurements were made on a CR (Agfa CR 25; Agfa, BELGIUM) system. Chest postero-anterior (PA), Hand PA, L-spine lateral radiographs were chosen for evaluation. Chest phantom (3D-torso; CIRS, USA) was used for Chest PA and L-spine lateral radiography. For Hand PA radiography, projections was done without phantom. Except Hand PA radiographs, noise was increased with delay time, and ghost image was appeared on overexposed area. Effect of delay after erasure on latent image was not seen on naked eye, but standard deviation (SD) of pixel value on overexposed area was relatively higher than that of other areas. On Hand PA and Chest PA radiographs, noise were not occurred by adjustment of erasure level. On L-spine lateral images at lower erasure level than standard level, noise including ghost image were occurred because of high tube current. Erasure thoroughness of CR system in our department was to be proved by these evaluation. The results of this study could be used as a baseline for IP initialization and reliability of CR images.

  • PDF

On the Development of Digital Radiography Detectors: A Review

  • Kim, Ho-Kyung;Cunningham, Ian Alexander;Yin, Zhye;Cho, Gyu-Seong
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.9 no.4
    • /
    • pp.86-100
    • /
    • 2008
  • This article reviews the development of flat-panel detectors for digital radiography based on amorphous materials, Important design parameters and developments are described for the two main components of flat-panel detectors: the X-ray converter and the readout pixel array. This article also introduces the advanced development concepts of new detectors. In addition, the cascaded linear systems method is reviewed because it is a very powerful tool for improving the design and assessment of X-ray imaging detector systems.

Maxillary sinus septum;panoramic radiographic and dental computed tomographic analyses in the planning of implant surgery (상악동 중격;임플란트 수술 계획시 파노라마와 치과용 전산화 단충촬영 분석)

  • So, Hyun-Ja;Jeong, Dong-Keun;Kwon, Jin-Hee;Ryu, So-Hyun;Kim, Hyung-Seop
    • Journal of Periodontal and Implant Science
    • /
    • v.36 no.1
    • /
    • pp.147-154
    • /
    • 2006
  • Surgical intervention in the posterior maxillary region requires detailed knowledge of maxillary sinus anatomy and the possible anatomical variations. This study evaluated the incidence, location of maxillary sinus septa by using radiographic (panoramic radiography and computed tomography) findings and comparison of panoramic radography with CT in antral anatomical variation. This study was based on data from 70 sinuses in partial dentate maxilla. The sample consisted of 61 patients(25 women and 36 men, with ages ranging between 19 and 77 years and a mean age of $49.4{\pm}11.3$ years) who were being treatment-planned to receive implant-supported restorations. First, the panoramic images were examined for the presence of antral septa by radiologist and examiner who don't know about CT findings. And incidence of antral septa was evaluated using an axial plane of CT image. The incidence of septa was compared between panoramic radiography and CT. The accuracy of the incidence was compared between radiologists and dentists. A total of 20 septa were found in 70 sinuses on CT image and the prevalence of one or more septa per sinus was found to be 28.6%. The assumed incidence of septa on panoramic radiography was $27.6%{\pm}2.2%$ in radiologist and $31.9%{\pm}5.8%$ in dentists. Erroneous diagnosis rate was 11.42% in radiologist and 15.96% in dentists. 40% of antral septa were located in the anterior(premolar) region, 30% of septa were located in the middle(first molar) and posterior(second molar) region separately. Prior to implant placement, it seems appropriate to consider panoramic radiography as a standard radiographic examination and periapical radiographs may be used to complete the findings in regions not sharply depicted in the panoramic radiograph. And cross-sectional imaging should be used in sites with severe bone loss and close proximity of the maxillary sinus.

Usability Evaluation of Foot Pedal Switch in X-ray Radiography System (진단용 엑스선 촬영장치에서 발판 스위치의 유용성 평가)

  • Kwon, Hyeokjin;Jung, Hongmoon;Jung, Jaeeun;Jung, Kyunghwan;Won, Doyeon
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.5
    • /
    • pp.651-658
    • /
    • 2018
  • A foot pedal switch in the diagnosis x-ray radiography system has been researched to improve radiologic technologist works and patient satisfaction. The switch has been installed in the diagnosis x-ray radiography system used in domestic clinics. Quantitative evaluation has been conducted by measuring the exposure dose reproducibility test, tube voltage, mAs, and percentage average error. Qualitative evaluation has been conducted by analysis of the radiologic technologists questionnaire. In the quantitative evaluation for the use of the foot pedal switch, the coefficient of variation was less than 0.05 in the exposure dose reproducibility test. In the mAs test, percentage average error of ${\pm}20%$ was measured. There was no problem raised since it meets the all inspection standards of the diagnosis x-ray generator. In the qualitative evaluation, most of the opinions are that it has a clinical value for the foot pedal switch in the diagnosis x-ray radiography system. Therefore, developing the foot pedal switch for the diagnosis x-ray radiography system can improve effectively the rapidity and accuracy of the radiologic technologist work. In addition, it is effective in decreasing the x-ray exposure of patients and increasing satisfaction for the medical service due to reduction of retaking x-ray.

Evaluation of alveolar bone density by intraoral periapical radiography (구강 내 치근단 방사선 영상을 이용한 치조골 골밀도 측정의 유용성 평가)

  • Park, Eun-Jin;Kim, David-Hyungjin;Kim, Eun-Suk
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.3
    • /
    • pp.233-238
    • /
    • 2014
  • Purpose: A method detecting change of jaw or alveolar bone density may be helpful in periodontal care, implant dentistry and evaluation of bone density of whole body. Materials and methods: In this study, bone density of intraoral periapical radiography using phantom-integrated XCP is compared with that of quantitative computed tomography (QCT). Results: Bone density of intraoral periapical radiography and the one measured by QCT showed high correlation (correlation coefficient = 0.92, P<.001) in alveolar bone, and relatively high correlation (0.73, P<.001) in cancellous bone. Conclusion: This study revealed possibility of scoring of bone density by intraoral periapical radiography.

Radiographic examination protocol and patient dose in lateral cephalometric radiography in Korea (국내 의료기관에서 측방두부규격방사선촬영시 임상에서의 촬영조건 및 환자 선량)

  • Choi, Jin-Woo
    • Imaging Science in Dentistry
    • /
    • v.40 no.4
    • /
    • pp.165-169
    • /
    • 2010
  • Purpose : To survey the radiographic examination protocol for lateral cephalometric radiographic examinations and to measure their patient doses in Korea and to compare the dose according to the size of hospital, the type of image receptor system, and the installation duration. Materials and Methods : The radiographic examination protocols (kVp, mA, and exposure time) for lateral cephalometric radiography were surveyed with 61 cephalometric radiographic equipments and their patient dose-area product (DAP) measured with a DAP meter (DIAMENTOR M4-KDK, PTW, Freiburg, Germany) for 51 cephalometric radiographic equipments. The radiographic examination protocols and patient doses were compared according to the size of hospital (university dental hospital, dental hospital, and dental clinic), the type of image receptor system (film-based, DR and CR type) and the installation duration, respectively. SPSS 12.0.1 for Windows (SPSS Inc., Chicago, USA) was used for independent t-test and ANOVA test. Results : The average protocols were 77.0 kVp, 12.7 mA, 6.2 second for cephalometric radiography. The average patient dose (DAP) was $128.0mGy\;cm^2$ and 3rd quartile dose (DAP) $161.1mGy\;cm^2$ for cephalometric radiography for adult male. There was no statistically significant difference at average patient DAP according to the size of hospital, the type of image receptor system, and the installation duration, repectively. Conclusion : The average patient dose was $128.0mGy\;cm^2$ and the third quartile patient dose $161.1mGy\;cm^2$ for lateral cephalometric radiography for adult male in Korea.