• Title/Summary/Keyword: Dental technique

Search Result 1,119, Processing Time 0.032 seconds

Diagnostic keys of the overcoming risk factors and achieving predictable esthetics in anterior single implant

  • Choi, Geun-Bae;Yang, Jong-Sook
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.16 no.2
    • /
    • pp.7-18
    • /
    • 2007
  • There is now an increased demand for harmony between the peri-implant gingiva and adjacent dentition. In the event of a pending loss of a single tooth in the aesthetic zone with healthy periodontium, expectation for optimal gingival and prosthodontic aesthetics are often very high. Unfortunately, bone resorption is common following the removal of an anterior tooth, compromising the gingival tissue levels for the eventual implant restoration. Also, improper implant placement and inadequate osseous-gingival support potentially deleterious aesthetic result. The creation of an esthetic implant restoration with gingival architecture that harmonizes with the adjacent dentitionis formidable challenge. The predictability of the peri-implant esthetic outcome may ultimately be determined by the patient's own presenting anatomy rather than the clinician's ability to manage state-of-the-art procedures. To more accurately predict the peri-implant esthetic outcome before removing a failing tooth, a considering of diagnostic keys is essential. This presentation addresses the useful diagnostic keys that affect the predictability of peri-implant gingival aesthetics and the overcoming of the risk factors in anterior single-tooth replacement; it also describes a surgical and prosthodontic technique in achieving a long term successful esthetic outcome. Proper diagnosis and understanding of the biological and periodontal variables of failing dentition and their response to surgical and prosthodontic procedures are the essence of predictability. Using a smart protocol that alters the periodontium toward less risk and more favorable assessment of the diagnostic keys before implant placement will provide the most predictable esthetic outcome. Simple diagnostic keys suggested this presentation are useful method to evaluate the overcoming of the risk factors in anterior single implant restoration.

  • PDF

Mechanical Properties of Zirconia Reinforced Glass-Ceramic (지르코니아 강화형 Glass-Ceramic의 기계적 성질)

  • Park, Eun-Eui;Dong, Jin-Keun;Lee, Hae-Hyoung;Song, Ki-Chang;Oh, Sang-Chun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.17 no.3
    • /
    • pp.199-204
    • /
    • 2001
  • This study was to investigate the reused possibility of zirconia reinforced glass-ceramic(IPS Empress Cosmo ceramic) with sprue button in the flexure strength and fracture toughness. 40 disk-shaped ceramic specimens (20 specimens: as-pressed material; 20 specimens: reused material) with approximately 1.7 mm thickness and 15 mm diameter were prepared by "lost wax" technique. The remnants(sprue buttons) were used for repressing. The surface treatments for the discs were gradually abraded with 320, 800, 1200, and 2000 grit SiC sandpaper. The specimens were evaluated their flexure strength with the biaxial flexure jig(ball-on-three balls) and their fracture toughness with Vickers Indentation-microfracture test. The Weibull moduli were calculated for biaxial flexural strength. The mean flexure strength and fracture toughness of each group were $122.2{\pm}18.3MPa$, $1.00{\pm}0.09MPa{\cdot}m^{0.5}$ (as-pressed ceramics), and $122.2{\pm}20.3MPa$, $1.01{\pm}0.10MPa{\cdot}m^{0.5}$ (reused ceramics). There were no significant differences in the strength and the fracture toughness between the as-pressed and the reused IPS Empress Cosmo ceramic (P>0.05). This implied zirconia reinforced glass-ceramic(IPS Empress Cosmo ceramic) could be used one more time by reusing of sprue button in the flexure strength and fracture toughness.

  • PDF

Comparison of ondansetron and granisetron for antiemetic prophylaxis in maxillofacial surgery patients receiving general anesthesia: a prospective, randomised, and double blind study

  • Savant, Kiran;Khandeparker, Rakshit Vijay Sinai;Berwal, Vikas;Khandeparker, Purva Vijay;Jain, Hunny
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.42 no.2
    • /
    • pp.84-89
    • /
    • 2016
  • Objectives: To compare the efficacy of intravenous ondansetron (4 mg, 2 mL) and granisetron (2 mg, 2 mL) for preventing postoperative nausea and vomiting (PONV) in patients during oral and maxillofacial surgical procedures under general anesthesia. Materials and Methods: A prospective, randomized, and double blind clinical study was carried out with 60 patients undergoing oral and maxillofacial surgical procedures under general anesthesia. Patients were divided into two groups of 30 individuals each. Approximately two minutes before induction of general anesthesia, each patient received either 4 mg (2 mL) ondansetron or 2 mg (2 mL) granisetron intravenously in a double blind manner. Balanced anesthetic technique was used for all patients. Patients were assessed for episodes of nausea, retching, vomiting, and the need for rescue antiemetic at intervals of 0-2, 3, 6, 12, and 24 hours after surgery. Incidence of complete response and adverse effects were assessed at 24 hours postoperatively. Data was tabulated and subjected to statistical analysis using the chi-square test, unpaired t-test, or the Mann-Whitney U-test as appropriate. A P-value less than 0.05 was considered statistically significant. Results: There was no statistically significant difference between the two groups for incidence of PONV or the need for rescue antiemetic. Both study drugs were well tolerated with minimum adverse effects; the most common adverse effect was headache. The overall incidence of complete response in the granisetron group (86.7%) was significantly higher than the ondansetron group (60.0%). Conclusion: Granisetron at an intravenous dose of 2 mg was found to be safe, well tolerated, and more effective by increasing the incidence of complete response compared to 4 mg intravenous ondansetron when used for antiemetic prophylaxis in maxillofacial surgery patients receiving general anesthesia. Benefits of granisetron include high receptor specificity and high potency, which make it a valuable alternative to ondansetron.

Superimposition: a simple method to minimize occlusal adjustment of monolithic restoration (디지털 장비의 중첩기능을 이용하여 단일체 수복물의 교합조정을 최소화한 증례)

  • Choi, Changhun;Kim, Sunjai
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.3
    • /
    • pp.253-258
    • /
    • 2016
  • The development of translucent zirconia enabled clinicians to choose a monolithic zirconia crown as one treatment modality in the posterior dentition. Careful occlusal adjustments are recommended for monolithic zirconia crowns because grinding zirconia inevitably causes phase transformation, which may deteriorate mechanical properties. intraoral scanners enable the clinician to scan and superimpose a complete tooth structure before preparation onto the prepared abutment. This technique helps to reproduce the original tooth form and occlusion of the patient. In this case report, prostheses were fabricated for patients with cracked or fractured tooth by applying intraoral scanner, Computer aided design-computer aided manufacturing (CAD-CAM) and monolithic zirconia crown to reproduce the occlusion of original tooth and to minimize occlusal adjustment. The clinical results were satisfactory in both esthetic and functional aspects.

Two-jaw surgery by use of Surgical Jaw Relator (Surgical Jaw Relator를 이용한 양악 수술 치험례)

  • Yang, Sang-Duck
    • The korean journal of orthodontics
    • /
    • v.35 no.3 s.110
    • /
    • pp.238-249
    • /
    • 2005
  • The contemporary two-jaw surgical approach usually involves a Le Fort osteotomy of the maxilla and a ramal osteotomy of the mandible with 3-dimensional repositioning of the jaws as well as the occlusal planes. After making the surgical treatment plan. the surgical movements are duplicated in the model surgery. During this procedure, reference poings and lines are drawn on the base of the models over the dental arch and sawcuts are mads according to these marked osteotomy lines. This technique, however, has been found to be inexact. especially when the laws are moved in several dimensions simultaneously. To overcome this. different methods have been developed for an accurate repositioning of the jaws as planned. A new appliance. Surgical Jaw Relater, has been devised by th8 author for the simple 3-dimensional relocation of the upper and lower models, resulting in the easy construction of the splints such as centric relation splint, intermediate and final splint. This article describes an introduction and a clinical application of this appliance. Through the application of this system to the orthognathic cases including two-law surgery. it is proved that the row device is very clinically useful.

An assessment of maxillary sinus and alveolar bone in cross-sectional linear tomogram of panorama (파노라마촬영장치의 협설선형단층상에 의한 상악동과 치조골 평가)

  • Kim Jae-Duk
    • Imaging Science in Dentistry
    • /
    • v.33 no.3
    • /
    • pp.137-141
    • /
    • 2003
  • Purpose: To evaluate the precision of measurements taken of dental implants in bucco-lingually sectioned views of the maxilla by linear tomograms of the panorama and to assess the visibility of the inferior wall of the maxillary sinus. Materials and Methods : Eighty sites prepared with implants of gutta percha cone in the sockets of the upper premolars and molars of 10 dry skulls were radiographically examined using linear tomograms of panorama, and scanned coronally and axially by computed tomography. The differences in mm between the measurements in bucco-lingually sectioned images of maxillary alveolar bone and the true length and width of the implanted gutta percha cones were compared as mean values (mean) and standard deviations (SD) for each radiographic technique. Linear tomography of panorama was compared with computed tomography for visualization of the relationship between the inferior wall of maxillary sinus and the end of each implant. Results: The deviations between the actual implant length and the measured values taken from the linear tomograms (0.44±0.39 mm) was significantly less than the measured values from the multiplanar reconstructed images of the axially scanned computed tomogram (1.21 ± 0.90 mm). There was statistically significant difference (p < 0.05) between two techniques in the differences between the measurements and true implant length. The relationship of the inferior border of maxillary sinus with end of implant was worse identified with the linear tomogram of panorama (68%) than the multiplanar reconstructed image of axially scanned computed tomogram (99%). Conclusion: We could not find any differences in the accuracy of length measurement between the linear tomogram of panorama and computed tomogram, but computed tomogram allowed for a better visualization of the inferior wall of the maxillary sinus than the linear tomogram.

  • PDF

Impact of surface roughness of gypsum materials on adaptation of zirconia cores

  • Kim, Ki-Baek;Kim, Jae-Hong;Kim, Sa-Hak
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.3
    • /
    • pp.199-206
    • /
    • 2015
  • PURPOSE. The present study investigated the influences of various gypsum materials on the precision of fit of CAD/CAM-fabricated prostheses and analyzed their correlation with surface roughness. MATERIALS AND METHODS. The master model of the mandibular right first molar was replicated, and four experimental groups based on two types of Type IV stone (GC Fujirock EP, Die keen) and two types of scannable stone (Aesthetic-Basegold, Everest Rock) were created to include a total of 40 specimens, 10 in each group. The surface roughness of the working models for the respective experimental groups was measured. Once the zirconia cores had been fabricated, the marginal and internal fits were measured with a digital microscope using the silicone replica technique. The mean and standard deviation of the respective points of measurement were computed and analyzed through the one-way ANOVA and Tukey's HSD test. The correlation between surface roughness and the precision of fit of the zirconia core was analyzed using the Pearson correlation analysis (${\alpha}$=.05). RESULTS. The zirconia cores fabricated from the scannable stone working models exhibited a superior precision of fit as compared to those fabricated from the Type IV stone working models. The correlation analysis results showed a clear positive correlation between surface roughness and the precision of fit of zirconia cores in all of the experimental groups (P<.05). CONCLUSION. The results confirmed that the surface roughness of dental working models has a decisive influence on the precision of fit of zirconia cores.

Three-dimensional finite element analysis of unilateral mastication in malocclusion cases using cone-beam computed tomography and a motion capture system

  • Yang, Hun-Mu;Cha, Jung-Yul;Hong, Ki-Seok;Park, Jong-Tae
    • Journal of Periodontal and Implant Science
    • /
    • v.46 no.2
    • /
    • pp.96-106
    • /
    • 2016
  • Purpose: Stress distribution and mandible distortion during lateral movements are known to be closely linked to bruxism, dental implant placement, and temporomandibular joint disorder. The present study was performed to determine stress distribution and distortion patterns of the mandible during lateral movements in Class I, II, and III relationships. Methods: Five Korean volunteers (one normal, two Class II, and two Class III occlusion cases) were selected. Finite element (FE) modeling was performed using information from cone-beam computed tomographic (CBCT) scans of the subjects' skulls, scanned images of dental casts, and incisor movement captured by an optical motion-capture system. Results: In the Class I and II cases, maximum stress load occurred at the condyle of the balancing side, but, in the Class III cases, the maximum stress was loaded on the condyle of the working side. Maximum distortion was observed on the menton at the midline in every case, regardless of loading force. The distortion was greatest in Class III cases and smallest in Class II cases. Conclusions: The stress distribution along and accompanying distortion of a mandible seems to be affected by the anteroposterior position of the mandible. Additionally, 3-D modeling of the craniofacial skeleton using CBCT and an optical laser scanner and reproduction of mandibular movement by way of the optical motion-capture technique used in this study are reliable techniques for investigating the masticatory system.

A Study on the Methods of Activation for CIEO in Health Junior College - About the on-the-Spot-Training of Department Health Education - (보건전문대학의 산학협동 효율화 방안에 관한 연구 -보건계학과의 현장실습을 중심으로 -)

  • Sung, Hwan-Kyung
    • Journal of Technologic Dentistry
    • /
    • v.13 no.1
    • /
    • pp.53-59
    • /
    • 1991
  • This study aimed at inquiring into the basic theory on CIEO(the Cooperation between Industry and Educational Organizations), grasping and analyzing the present situation of the health junior college, the present condition of CIEO and into problem and seeking to find a solution to activate the CIEO of the health junior colleges. This study suggested five methods as the method of consolidating the on-the-spot-training as below : 1. The execution of the basic research for the on-the-spot-training. And the reorganization of the existing curriculum into the curriculum the industrial organization requires. 2. The participation in solving commonly the problems of the industrial organization and in education. The establishing of the guidance system assuming exclusive charge of the on-the-spot-training. 3. The extension of the period of the on-the-spot-training and the reorganization of an educational system. The submission of the evaluation sheet for the on-the-spot-training. 4. The securing of the educational dost spent on the on-the-spot-training and the imposition of benefits on the industrial organization. 5. The persistent support for the on-the-spot-training at the governmental dimension. It is required that the CIEO law should be enacted as the legal and institutional solution and that government should lend systematic support to the business enterprise exeuting the industrial educational cooperation such as the institutional support for and the imposition of benifits on the cost of research. The cost of research and development, the cost of internal education and training, and the cost of experiment and practice.

  • PDF

Research on characteristics and treatment duration and method of patients with tooth impaction who visited Gachon University Gil Hospital Orthodontic Department (year 2005-2008) (가천의대 길병원 교정과에 내원한 매복치 환자의 특성과 치료기간 및 방법에 관한 연구(2005년~2008년))

  • Moon, Cheol-Hyun;Kang, Hyun-Wook;Choi, Jin-Hugh
    • The Journal of the Korean dental association
    • /
    • v.49 no.4
    • /
    • pp.211-218
    • /
    • 2011
  • Purpose: An impacted tooth is defined as a tooth that shows delayed eruption and is expected to erupt incompletely by clinical and radiograph examination despite it reaching its expected time of eruption. The aims of this study were to investigate the clinical and radiological characteristics and treatment duration and method of impacted teeth in Korean patients. Materials and Methods: For this study we used clinical records, study models, panoramic radiographs and intraoral photographs of patients who attended Gachon University Gil Hospital Orthodontic Department between 2005 and 2008. There were 164 patients with a total number of 202 impacted teeth. Results: Male patients shows a little more prevalence than female patients (1.13:1). The under 12 age group had the highest prevalence of tooth impaction, and the over 19 age group showed the least prevalence of tooth impaction. The ratio of tooth impaction between the left to right ratio was 1.73:1 and maxilla and mandible was 1.84:1. The impacted teeth were most commonly positioned buccally (76 cases, 41.5%). Full nap closure technique (108 cases, 81.2%)was most frequently used for attachment of surgical traction hooks. Maxillary canine impaction was most commonly encountered both in male and female patients. The mean treatment period was 12.2 months and the success rate of treatment was 90.3%. The canine tooth shows the longest treatment time and highest failure rate. The ankylosis was the major cause of failure. Conclusion: Impacted teeth most commonly show in left side maxilla in the under 12 age group. And it is most commonly positioned buccally. The mean treatment period was 12.2 months, and the success rate of treatment was 90.3%.