• Title/Summary/Keyword: Dental technique

Search Result 1,116, Processing Time 0.026 seconds

AGAR-ALGINATE COMBINED IMPRESSION TECHNIQUE AND DIMENSIONAL CHANGE RESULTING FROM IDOPHOR DISINFECTION (아기-알지네이트 연합 인상체의 보관방법 및 idophor 침적소독에 의한 체적 변화에 관한 연구)

  • Oh Nam-Sik;Seo Joung-Min;Kim Sun-Hee;Youn Young-Ah;Shim Joon-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.1
    • /
    • pp.21-29
    • /
    • 2004
  • Statement of problem : Because dental impression can be a cross-infection source, disinfection, such as immersion disinfection is nessecary. However, the disinfection process may change the volume of the impression cast. Purpose : The purpose of this study is to find out the effects on dimensional change of different storage times and methods, of agar-alginate impression when immersed in a 5% idophor disinfectant. Material and Methods : An agar-alginate impression was made from a mandible model and then was disinfected and stored according the experimental conditions and a stone model was produced. Measurements were taken between reference points on the original mandible model and they were compared to measurements taken between reference points on the stone model. The study was divided into 4 groups. In group 1, the impression was stored in a 100% humidor for 30 minutes, 1 hour, 2 hours, 3 hours, 4 hours, 6 hours, 12 hours and 24 hours and stone models were made at each time. In group 2, the impression was immersed in 5% idophor disinfectant and then stored in a 100% humidor for the same length of times as group 1, and stone models were made at each time. In group 3, the impression was stored in extend-A-pourR, a special storage solution for 30 minutes, 1 hour, 2 hours, 3 hours, 4 hours, 6 hours, 12 hours, 24 hours 3 days, and 7 days and stone models were made at each time. In group 4, the impression was immersed in 5% idophor disinfectant and then stored in stored in extend-A-pourR, a special storage solution for the same length of times as group 3, and stone models were made at each time. 5 impressions and stone models were made at each time to make a total of 180. The Student-t test (P < .05) was used to do a statistical analysis of the measurements of the mandible model and stone models. The repeated-measure 2-way analysis of variance (P < .05) was used to do a statistical analysis of the difference in the 4 groups. Results : The percent liner dimensional change was from $0.25{\pm}0.03%$ (group 1, 30 minutes) to $0.34{\pm}0.06%$ (group 4, 7 days). No significant change was noticed between the 4 groups. Conclusion : According to the above study, in both methods, least dimensional change was recorded when the storage times were short and in both methods, immersion in 5% idophor disinfectant did not effect dimensional change in the agar-alginate impression.

Effects of Ethanol on the Fluidity of Plasma Membrane Vesicles Isolated from Cultured Mouse Myeloma Cell Line Sp2/0-Ag14 (Ethanol이 배양된 Mouse Myeloma Cell Line Sp2/0-Ag14로부터 분리한 형질막의 유동성에 미치는 영향)

  • Yun, Il;Chung, In-Kyo;Park, Yeong-Min;Kim, Jin-Bom;Yu, Seoung-Ho;Kang, Jung-Sook
    • The Korean Journal of Pharmacology
    • /
    • v.29 no.1
    • /
    • pp.149-156
    • /
    • 1993
  • Intramolecular excimerization of 1,3-di(1-pyrenyl)propane (Py-3-Py) and fluorescence polarization of 1,6-diphenyl-1,3,5-hexatriene (DPH) were used to examine the effects of ethanol on the rate and range of lateral diffusion of bulk bilayer structures of plasma membrane vesicles isolated from cultured mouse myeloma cell line Sp2/0-Ag14 (Sp2/0-PMV). In a concentration-dependent manner, ethanol increased the excimer to monomer fluorescence intensity ratio (I'/I) of Py-3-Py in the Sp2/0-PMV and decreased the anisotropy (r), limiting anisotropy $(r_{\infty})$, and order parameter (S) of DPH in the Sp2/0-PMV. This indicates that ethanol increased both the lateral and rotational diffusion of the probes in the Sp2/0-PMV. Selective quenching of DPH by trinitrophenyl groups was utilized to examine the transbilayer asymmetric rotational diffusion of the Sp2/0-PMV. The anisotropy (r), limiting anisotropy $(r_{\infty})$, and order parameter (S) of DPH in the inner monolayer were 0.022, 0.029, and 0.063, respectively, greater than calculated for the outer monolayer of the Sp2/0-PMV. Selective quenching of DPH by trinitrophenyl groups was also utilized to examine the transbilayer asymmetric effects of ethanol on the range of rotational diffusion of the Sp2/0-PMV. Ethanol had a greater fluidizing effect on the outer monolayer as compared to the inner monolayer of the Sp2/0-PMV. It has been proven that ethanol exhibits a selective rather than nonselective fluidizing effect within transbilayer domains of the Sp2/0-PMV.

  • PDF

THREE DIMENSIONAL FINITE ELEMENT ANALYSIS OF $BR{\AA}NEMARK\;NOVUM^{(R)}$ IMMEDIATE IMPLANT PROSTHODONTIC PROTOCOL ($Br{\aa}nemark\;Novum^{(R)}$ 즉시 임플랜트 보철 수복 방법에 관한 삼차원 유한요소 분석적 연구)

  • Kim Woo-Young;Kim Yung-Soo;Jang Kyung-Soo;Kim Chang-Whe
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.5
    • /
    • pp.463-476
    • /
    • 2001
  • Since the treatment of edentulous patients with osseointegrated implant was first introduced more than 30 years ago, implant therapy has become one of the most important dental treatment modalities today. Based on the previous experience and knowledge, $Br{\aa}nemark\;Novum^{(R)}$ protocol was introduced with the concept of simplifying surgical and prosthetic technique and reducing healing time recently. This protocol recommends the installation of three 5mm wide diameter futures in anterior mandible and the prefabricated titanium bars for superstructure fabrication. This study was designed to analyze the stress distribution at fixture and superstructure area according to changes of fixture number, diameter and superstructure materials. Four 3-dimensional finite element models were fabricated. Model 1 - 5 standard fixtures (13mm long and 3.75mm in diameter) & superstructure consisted of type IV gold alloy and resin Model 2- 3 wide diameter fixtures (13mm long and 5.0mm in diameter) & superstructure consisted of type IV gold alloy and resin Model 3-3 wide diameter fixtures (13mm long and 5.0mm in diameter) & superstructure consisted of titanium and resin Model 4-3 wide diameter fixtures (13mm long and 5.0mm in diameter) & superstructure consisted of titanium and porcelain A 150N occlusal force was applied on the 1st molar of each model in 3 directions - vertical($90^{\circ}$), horizontal($0^{\circ}$) and oblique($120^{\circ}$). After analyzing the stresses and displacements, following results were obtained. 1. There were no significant difference in stress distribution among experimental models. 2. Model 2, 3, 4 showed less amount of compressive stress than that of model 1. However, tensile stress was similar. 3. Veneer material with a high modulus of elasticity demonstrated less stress accumulation in the superstructure. Within the limites of this study, $Br{\aa}nemark\;Novum^{(R)}$ protocol demonstrated comparable biomechanical properties to conventional protocol.

  • PDF

Evaluation of marginal fidelity of copy-milled and CAD/CAM all ceramic crowns

  • Jeong Seung-Mi;Kang Dong-Wan;Wolf Christoph
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.3
    • /
    • pp.243-249
    • /
    • 2001
  • Statement of the problem. The interest in all-ceramic restorations has increased as more techniques have become available. With the introduction of machinable dental ceramics and CAD/CAM systems or Copy-milling systems there is a need for evaluating the quality levels of these new fabrication techniques. Purpose. This study was to evaluate the fitting accuracy of machined all-ceramic crowns made out of an industrially prefabricated feldspathic porcelain. Material and Methods. Three master models with different cutting depth (0.8mm/1.0mm/1.2mm)were produced using a palladium-silver alloy. A total of 36 working dies, 12 of each form, was used for the modellation of prototype resin copings and 36 additional crowns, 12 of each cutting depth, were produced by using the $CEREC^{(R)}2$ system for all crowns. The maginal fit of all 72 crowns was then evaluated on their respective master die at 54 circularly staggered points of measurement per crown under a fixation pressure of 30 N by using a computerized video image system. Results. The medians of the copy-milled $CELAY^{(R)}$ crowns ranged from 29 to $36{\mu}m$. The highest value for the marginal gap was found in group B (cutting depth 1.0mm) at $107{\mu}m$. The median for the $CEREC^{(R)}2$ crowns was found between 43.5 and $70{\mu}m$. The maximum values for all three groups ranged from $181{\mu}m$ to $286{\mu}m$. With $286{\mu}m$ the highest value for marginal gap was found in group C. the Kruskal-Wallis test and multiple comparisons analysis procedure revealed a significant influence of the production technique on the marginal fit in all three groups (p<0,02). Conclusion. 1. The $CELAY^{(R)}$ system is capable to produce all-ceramic crowns with a significantly better marginal fit than the $CEREC^{(R)}2$ system. 2. As far as premolar crowns produced with the $CEREC^{(R)}2$ system are concerned, the cutting depth has a significant influence on fitting accuracy. 3. The production of crowns with an acceptable marginal fit is possible with both systems. However, adhesive luting is recommended for milled feldspathic porcelain crowns.

  • PDF

Influence of platform switching on crestal bone resorption (치조정 골흡수에 대한 platform switching이 미치는 영향)

  • Kim, Do-Young;Kim, Tae-Il;Seol, Yang-Jo;Lee, Yong-Moo;Ku, Young;Rhyu, In-Chul;Chung, Chong-Pyoung;Han, Soo-Boo
    • Journal of Periodontal and Implant Science
    • /
    • v.38 no.2
    • /
    • pp.135-142
    • /
    • 2008
  • Purpose: Numerous studies have shown that crestal bone resorption around the implant was related to the location of the implant abutment junction(IAJ). Recently it was hypothesized that platform switching termed the inward horizontal repositioning of the IAJ might limit bone resorption around the implants. The purpose of this clinical study was to evaluate the effect of platform switching on crestal bone resorption. Materials and Methods: The crestal bone loss of 65 external hex implants in 26 patients were radiographically measured at crown placement and follow-up examinations. 23 standard implants(non-platform switching group, NP) were connected with the matching abutments and 42 wide implants(platform switching group, PS) were connected with the 1 mm smaller diameter abutments. Results: There was significant difference of crestal bone loss between NP group and PS group. For implants in the NP group, mean crestal bone loss was $1.18{\pm}0.68\;mm$ at crown placement and $1.42{\pm}0.41\;mm$ at follow-up. The meal bone loss in PS group was $0.47{\pm}0.52\;mm$ at crown placement and $0.60{\pm}0.65\;mm$ at follow-up. When the crestal bone changes according to placement depths of implants were compared, subcrestal position of IAJ had a significantly less bone loss in PS group, but it was not in NP group. Conclusion: Within the limits of the present study, it was concluded that platform switching technique might decrease crestal bone loss around the implants. Additionally, when the IAJ of implant was placed 1 mm deeper in the alveolar bone, the effect of platform switching on bone loss was enhanced.

A Literature Review on Nano-Modified Implant Surfaces (나노구조 표면에 관한 문헌고찰)

  • Park, Go-Woon;Cha, Min-Sang;Kim, Dae-Gon;Park, Chan-Jin;Cho, Lee-Ra
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.2
    • /
    • pp.141-151
    • /
    • 2013
  • The nano-surface modification techniques could be classified; internal modifications which enhance surface roughness and porosity in nano level and external modifications as nano particle coating. Nano-modified implant surface has various morphograpies such as nanotube, nanopit, nanonodule and polymorphic structures. Creating surface depends upon preparation method and material, however, there is no standard preparation technique not yet. The nano-modified surfacet is electrochemically stable comparing with the surface modified in micron level. Nano-modified surface has little cytotoxicity, stimulates osteoblast proliferation and differentiation. Moreover, it decreases soft tissue intervention by interrupting the proliferation of fibroblast. Nanostructure has similar size and shape with cells and proteins, consequently leads to good biocompatibility and enhanced osseointegration. However, the actual effect in vivo is limited, due to the distance of effect. Even if nano-modified surface has antibiotic property due to photocatalysis, short duration time makes clinical application questionable. Further investigations should focus on the optimal nano-modified surface, which has many potentials.

The Study of Bone Formation around Titanium Implants Placed in Adrenalectomized Rat's Tibia (부신 제거 백서에 티타늄 임플랜트 매식후 주위 골형성에 관한 연구)

  • Choi, Kab-Lim;Kim, Jong-Ryoul;Park, Bong-Soo;Sung, Iel-Yong
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.22 no.3
    • /
    • pp.274-287
    • /
    • 2000
  • The use of dental implants has increased tremendously in recent years and is expected to increase even more in the future. The successful outcome of any implant procedure is surely dependent on interrelationship of the various components of an equation that includes biocompatibility of implant material, macroscopic and microscopic nature of the implant surface, the status of implant bed, surgical technique, undisturbed healing phase and subsequent prosthetic design and long-term loading phase. The purpose of this study was to clarify the effects of adrenalectomy on the osseointegration of pure titanium implants. Seventy rats, 11 weeks of age, were divided into two groups : an adrenalectomized group and a control group. Titanium screw implant(diameter, 2.0mm; length, 3.5mm) was placed into left tibia of 70 rats, 35 in control group and 35 in the experimental group. The rats were sacrificed at different time interval (1, 2, 3, 4, 6, 8, and 12 weeks after implantation) for histopathologic observation, histomorphometric analysis and immunohistochemistry with fibronectin and CD44 antibody. The results obtained from this study were as follows: 1. Histopathogically, findings, newly formed bone was seen at 3 weeks control group and became lamellar bone at 12 weeks. At 6 weeks, lipocytes were observed in bone marrow space. Thickness of regenerated trabecular bone increased till 6 weeks after then, that decreased gradually. 2. By histomorphometric analysis, marrow bone density and contact ratio of marrow bone to implant decreased significantly from 8 to 12 weeks in experimental group compared to control group and also total bone to implant contact ratio decreased significantly from 4 to 12 weeks in experimental group compared to control group. 3. Fibronectin immunoreactivity was very strong at 3 and 4 weeks control group. And after that reduced gradually. But it was continuously strong from 1 to 12 weeks experimental group. 4. CD44 immunoreactivity was very strong in the newly formed osteoblasts at 3 and 4 weeks control group. But it reacted minimally later. However, it reacted continuously strong from 3 to 12 weeks experimental group. From these results, bone to implant contact ratio decreased gradually from 4 weeks in adrenalectomized group compared to control group. CD44 and fibronectin immunoreactivities were strong at all times in adrenalectomized rats. Therefore, it could be stated that immature bone remained continuously for a long time and not readily proceeded into mature status.

  • PDF

MORPHOLOGIC AND POSITIONAL CHANGE OF THE PROXIMAL SEGMENTS AFTER INTRAORALVERTICAL RAMUS OSTEOTOMY OF THE MANDIBULAR PROGNATHISM ON SUBMENTOVERTEX CEPHALOGRAM (하악골 전돌증환자의 구내 하악골상행지 수직골절단술후 이하두정 계측방사선사진상에서의 근심골편의 형태 및 위치 변화)

  • Chung, Jae-Hyung;Park, Hyung-Sik;Hwang, Chung-Ju
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.29 no.1
    • /
    • pp.26-34
    • /
    • 2003
  • Intraoral Vertical Ramus Osteotomy,along with Sagittal Split Ramus Osteotomy,is an popular surgical technique performed on mandibular prognathism. However Intraoral Vertical Ramus Osteotomy has been suspected for an initial mobilization at the healing phase of segment because it does not employ the rigid fixation between segments. To execute a study on the healing phase of segment after Intraoral Vertical Ramus Osteotomy on the horizontal plane, 102 patients (204 parts) who were diagnosed mandibular prognathism and took Intraoral Vertical Ramus Osteotomy at the Yonsei University dental hospital were observed during the period of before operation, immediately postoperation, 1 month, 3 months, 6 months, and 12 months. The change in the width of segment and horizontal angle of proximal segment and condylar head on the Submentovertex Cephalogram taken from those patients represented following results. 1. The width of proximal and distal segment decreased with the lapse of time. It decreased into 84.5% between immediate postoperative and 6M and even continued to decrease till 12M. 2. The horizontal angle of the proximal segment did medial rotation according as the lapse of time and rigorously continued till 3M. The rotation angle of condylar head indicated its tendency of recurrence to the original position but the entire recurrence was not allowed. The bigger an initial angle was, the higher was the tendency of recurrence after the operation while the rotation angle remained still bigger. 3. After grouping into group 1, group 2,and group 3 based on the extent of the variation of rotation angle of condylar head at immediate postoperative, the variation of rotation angle was measures in each group. The result presented that the initial rotation angle of condylar head had correlation with that of proximal segment but had no relation with the extent of setback of the mandible. However a quantitative analysis alone is not a sufficient method for analyzing the healing phase of segment on the horizontal plane.Therefore a multilateral analysis using 3 dimensional data such as CT is recommendable for the future study.

The Occlusal Evaluation and Treatment Planning for Prosthodontic Full Mouth Rehabilitation (보철학적 교합 재구성을 위한 교합진단과 치료계획)

  • Lee, Seung-Kyu;Lee, Sung-Bok;Choi, Dae-Gyun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.16 no.2
    • /
    • pp.149-159
    • /
    • 2000
  • Occlusal disease is comparable to periodontitis in that it is generally not reversible. Occlusal disease, however, like periodontitis, often maintainable. It does itself to treatment and when restorative dentistry is utilized it becomes, in that sense, reversible. Moreover, a systematized and integrated approach will lead to a prognosis that is favorable and predictable. This approach facilitates development of optimum oral function, comfort, and esthetics, resulting in a satisfied patient. Such a systematized approach consists of four logical phase : (1) patient evaluation, (2) comprehensive analysis and treatment planning, (3) integrated and systematic reconstruction, and (4) postoperative maintenance. An integrated treatment plan is first developed on one set of diagnostic casts, properly mounted on a semiadjustable articulator using jaw relationship records. This is accomplished by using wax to make reconstructive modifications to the casts. These modified casts become the blueprint for planned occlusal changes and the fabrication of provisional restorations. The treatment goals are : (1) comfortably functioning temporomandibular joints and stomatognathic musculature, (2) adherence to the basic principle of occlusion advocated by Schuyler, (3) anterior guidance that is in harmony with the envelope of function, (4) restorations that will not violate the patient's neutral zone. This report shows the treatment procedures for a patient whose mandibular position has been altered due to posterior bite collapse. Migration of the maxillary anterior teeth had occurred, and the posterior occlusal contacts showed pathologic interference. Precise diagnosis using mounted casts was executed and prosthodontic reconstruction by the aid of an unconventional orthodontic correction on maxillary flaring was planned. An unconventional orthodontic correction can be accomplished by using preexisting natural teeth, which can be modified for use in active tooth movement or splinted together for orthodontic anchorage. This technique has an advantage over conventional fixed appliance orthodontic therapy because it can accomplish tooth movement concurrently with restorative and periodontal therapy. On occasion, minor tooth movement can be necessary to achieve the optimum occlusal scheme, crown form, and tooth position for the forces of occlusion to be displaced down the long axis of the periodontally compromised teeth. Once the occlusion, periodontal health, and crown contours for the provisional splinted restoration are acceptable, the final splinted restoration can be similarly fabricated, and it becomes an excellent orthodontic retainer.

  • PDF

Restoration of an Edentulous Patient with CAD/CAM Guided Implant Surgery ($NobelGuide^{TM}$) and Immediate Loading: Case Report (무치악 환자에서 CAD/CAM을 이용한 임플란트 식립($NobelGuide^{TM}$) 및 즉시하중 증례)

  • Ko, Kyoung-Ho;Lim, Kwang-Gil;Kim, Dae-Gon;Park, Chan-Jin;Cho, Lee-Ra
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.2
    • /
    • pp.233-245
    • /
    • 2011
  • With the use of computed tomography (CT), computer-aided design/computer-assisted machining (CAD/CAM) technology and internet, the implant dentistry has been evolved. The surgical templates made by CAD/CAM technology and precise installation of implants, permit restorations to be inserted immediately after implants have been placed. The advantages of CAD/CAM guided implant procedures are flapless, minimally invasive surgery and shorter surgery time. With this technique, less postoperative morbidity and delivery of prosthesis for immediate function would be possible. A patient with an edentulous maxilla and mandible received 7 implants in mandible using CAD/CAM surgical templates. Prefabricated provisional fixed prostheses were connected immediately after implant installation. Provisional prostheses were evaluated for aesthetics and function during 6 months. Definitive prostheses were fabricated. At 6 months recall appointment, patient's occlusion was slightly changed. To prevent additional adverse effect, regular check-up and occlusal adjustment would be needed.