• 제목/요약/키워드: Dental restoration

Search Result 869, Processing Time 0.032 seconds

The thickness of facial and palatal bone of maxillary anterior natural teeth: radiographic analysis using computed tomography (전산화 단층 촬영을 이용한 상악 전치부 자연치의 순측과 구개측 골의 두께 계측)

  • Bae, Soo-Yong;Park, Jung-Chul;Sohn, Joo-Yeon;Um, Yoo-Jung;Jung, Ui-Won;Kim, Chang-Sung;Cho, Kyoo-Sung;Chai, Jung-Kiu;Kim, Chong-Kwan;Choi, Seong-Ho
    • The Journal of the Korean dental association
    • /
    • v.47 no.10
    • /
    • pp.669-676
    • /
    • 2009
  • Purpose : Anterior region is crucial area for esthetic implant restoration. However, the alveolar process undergoes atrophy after removal of teeth and creates unfavorable situation for implant installation. The knowledge of the thickness of alveolar bone is required to estimate and expect the bone resorption after extraction. The aim of this study is to measure facial, palatal and faciopalatal bone thickness on maxillary anterior teeth. Methods : Facial, palatal, and faciopalatal bone thickness were measured on the computed tomography (CT) images from 57 patients, using an image analyzer program (Ondemand$3D^{(R)}$, Cybermed, Seoul, Korea). Results : The thickness of facial bone in incisors, lateral incisors and canines were less than 1 mm. The thickness of facial bone increased from anterior to posterior region and the thickness of palatal bone increased from posterior to anterior region. Conclusion : The measurement can be used for planning implant surgery before extraction. CT has are clinically useful in the evaluation of thickness of alveolar bone.

  • PDF

DECORONATION ON ANKYLOSED PERMANENT INCISOR AFTER DENTAL TRAUMA (외상으로 유착된 영구 전치에서의 치관 절제술)

  • Kang, Yu-Jin;Kim, Young-Jin;Kim, Hyun-Jung;Nam, Soon-Hyeun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.37 no.2
    • /
    • pp.252-259
    • /
    • 2010
  • Trauma commonly leads to ankylosis for the tooth whose periodontal ligaments have been injured. In growing patients, an ankylosed tooth can disrupt alveolar development, resulting in infraocclusion of the affected tooth. Consequently, this causes aesthetic problems during adolescence, interferes with prosthetic treatment due to the inclination of adjacent teeth, and complicates orthodontic dental movement. When the infraoccluded ankylosed tooth is extracted, a considerable amount of alveolar bone is lost, especially in the maxillary anterior region. Moreover, depression of the thin buccal alveolar bone compromises aesthetic restoration. In order to prevent alveolar bone loss, the ankylosed tooth should be treated by decoronation. In the present study, the traumatically injured maxillary incisors of 9-year-old and 10-year-old patients that present infraocclusion accompanied by ankylosis were treated with decoronation procedures. Decoronation procedures were performed when the affected teeth were 2-3 mm below relatively to the adjacent teeth. Moreover, the patients were treated before they get to 16 years old considering the maximum growth peak of the korean adolescents. As the results, there are favorable clinical results associated not only with preservation of horizontal alveolar volume but also with increase in vertical alveolar height after decoronation in growing individuals.

HISTOLOGICAL AND CLINICAL STUDY OF ARTIFICIAL DERMIS IMPLANTATION FOR RESTORATION OF SOFT TISSUE DEFECTS (연조직 결손부 회복을 위한 인공진피 이식의 조직학적 및 임상적 연구)

  • Ryu, Sun-Youl;Kim, Sun-Kook
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.32 no.5
    • /
    • pp.410-417
    • /
    • 2006
  • The present study was aimed to compare the resorption rate and the histological change of the autogenous dermis and the artificial dermis (Terudermis$^{(R)}$) after the transplantation, and to report the clinical results of the use of Terudermis$^{(R)}$ in order to restore the soft tissue defect. Twenty mature rabbits, weighing about 2 kg, were used for the experimental study. The autogenous dermis and the Terudermis$^{(R)}$ size 1${\times}$1 cm were transplanted to the space between the external abdominal oblique muscle and the external abdominal oblique fascia of the each rabbits. They were divided into 4 groups (n=5 each) and gathered at 1, 2, 4, and 8 weeks after the transplantation. The resorption rate was calculated, and H-E stain was preformed to observe the histological changes. The chart review of the 17 patients who received Terudermis$^{(R)}$ graft to the facial soft tissue defects was conducted for the clinical study. The resorption rate at 8 weeks after the transplantation was 21.5% for the autogenous dermis, and 36.4% Terudermis$^{(R)}$. In microscopic examinations, the infiltration of the inflammatory cells and the epidermal inclusion cyst were observed in the autogenous dermis graft. The neovascularization and the progressive growth of the new fibroblast were shown in the Terudermis$^{(R)}$ graft. In clinical data of 17 patients, the size of the grafted Terudermis$^{(R)}$ was from 1.5$cm^2$ to 7.5$cm^2$ (average 3.5$cm^2$). Follow-up ranged from 5 to 25 months. Fourteen patients with cleft palate demonstrated stability of the graft and unremarkable complications. But unstability of the graft and the partial relapse were observed in three patients received the vestibuloplasty. These results indicate that Terudermis$^{(R)}$ can be available substitute of autogenous dermis because of the stability about resorption, the histocompatibility, and the unremarkable clinical complications.

Screw Loosening of Various Implant Systems (수종의 임플랜트 시스템의 나사풀림에 관한 연구)

  • Ahn, Jin-Soo;Cho, In-Ho;Lim, Ju-Hwan;Lim, Heon-Song
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.18 no.2
    • /
    • pp.81-91
    • /
    • 2002
  • Dental implant systems have shown many post-surgical problems and One of the most frequent problem is screw loosening. To reduce screw loosening, a number of methods have been tried and recently fundamental modification of fixture-abutment connection structure was developed and used the most frequently. Former implant system structure, such as Br${\aa}$nemark, had external hex with the height of 0.7 mm and later, fixture with external hex of 1.0 mm height and internal hex structure were developed. In addition, the method of morse taper application was introduced to reduce screw loosening. In this study, the level of screw loosening of each implant systems was compared based on the vibration loosening measurement of abutment screw of each implant systems. Analysis of measured value was performed using 3 kinds of methods, (i) Percentage of average of initial 3 times loosening-torque value(initial loosening value) to tightening-torque of 30 Ncm, (ii) Percentage of loosening-torque value after 200 N strength loaded(experimental value) to initial loosening value and (iii) Percentage of experimental value to 30 Ncm of tightening-torque. Each result of analyses shows the value of initial loosening, loosening by repetitive load and final loosening level. The results of this study were as follows. (1) Percentage of initial loosening value to tightening-torque was increased in order of 0.7 mm external hex, 1.0 mm external hex, internal hex and internal taper and all values between each groups showed statistical significance (p<0.05). (2) Percentage of experimental value to initial loosening value was increased in order of internal hex, 0.7 mm external hex, 1.0 mm external hex and internal taper. Value of internal taper showed significant difference with that of 0.7 mm external hex and internal hex (p<0.05). (3) Percentage of experimental value to tightening torque was increased in order of 0.7 mm external hex, 1.0 mm external hex, internal hex and internal taper. Values of all groups showed statistical significance (p<0.05) except between the groups of 1.0 mm external hex and internal hex. Based on those results, there was no significant difference of loosening-torque by repetitive loading except internal taper. It is supposed that implant system with high resistant capability against initial loosening could be recommended for clinical use. In addition, in case of single implant restoration, 1.0 mm external hex or internal hex could be recommended rather than 0.7 mm external hex, and the use of internal taper would be the most useful way to reduce screw loosening.

HYDROLYTIC DEGRADATION OF DENIAL COMPOSITE RESINS (수종 치과용 복합레진의 가수분해)

  • Yang, Kyu-Ho;Kim, Jung-Ran
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.27 no.2
    • /
    • pp.370-378
    • /
    • 2000
  • The composite restorative resins have their insufficient resistance to wear. The subsurface degradation within the restoration is considered to be associated with wear. The aim of this study was to evaluate the resistance to degradation of six commercial composite resins in an alkaline solution. The brands studied were Clearfil APX(Kuraray), Heliomolar(Vivadent), Surefil(Dentsply), TPH(Dentsply), Tetric Ceram(Vivadent), and Z100(3M). Preweighed discs of each brand were exposed 0.1N NaOH solution at $60^{\circ}C$. After 14 days they were removed, neutralized with HCL, washed with water and dried to constant mass at $60^{\circ}C$. Resistance to degradation was evaluated on the basis of the following parameters: (a) mass loss(%) - determined from pre-and post-exposure specimen weights; (b) Si loss (ppm)-obtained from ICP-AE analysis of solution exposed to specimens; and (c) degradation depth$({\mu}m)$ - measured microscopically (SEM) from polished circular sections of exposed specimens. The results were as follows: 1. The mass loss was in descending order by Z100, TC H, S, CL, TPH and in the range of $0.45\sim3.64%$ 2. The degradation layer depth was in descending order by H, Z100, S, TC, TPH, CL and in the range of $10.85\sim73.38{\mu}m$ 3. For the Si concentration, Z100 was the highest of all 4. The highly significant correlation(r=0.81, p<0.05) was observed between mass loss and degradation depth. 5. Under scanning electronmicroscopy, the degradation of connection between resin matrix and fillers was observed 2 weeks after soaking in NaOH solution.

  • PDF

Mechanical strength of Zirconia Abutment in Implant Restoration (지르코니아 임플란트 지대주의 기계적 강도에 관한 연구)

  • Shin, Sung-ae;Kim, Chang-Seop;Cho, Wook;Jeong, Chang-Mo;Jeon, Young-Chan;Yun, Ji-Hoon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.4
    • /
    • pp.349-360
    • /
    • 2009
  • Purpose: As the esthetic demands of dental implant patients are increased, the demands of zirconia as implant abutment material are also increased. It has non-metalic color, good biocompatibility, high strength and high toughness. Even thought the advatage of zirconia abutment, there are a few studies about mechanical properties of zirconia abutment. This study evaluated the mecanical strength with compressive bending strength and endurance limit of implant-zirconia abutment assembly. Materials and Methods: Static and cyclic loading of implant-Zirconia abutment assembly were simulated under worst case condition according to ISO. Test groups were implants of external butt joint with straight regular diameter and angled regular diameter zirconia abutment, implant of external butt joint with narrow straight diameter zirconia abutment and implant of internal conical joint with straight narrow diameter zirconia abutment. All test group were evaluated the mecanical strength with compressive bending strength and endurance limit. After fatique testing, fracture surface were examined by SEM. Results: The compressive bending strengths exceed 927N. Regular diameter zirconia abutment were stronger than narrow diameter zirconia abutment(P<.05). The endurance limits ranged from 503N to 868N. Conclusion: Within the limitation of this study, zirconia implant abutment exceeded the estabilished values for maximum incisal biting forces reported in the literature.

EVALUATION OF THE ACCURACY OF FIXTURE-LEVEL IMPRESSION TECHNIQUE FOR INTERNAL CONNECTION IMPLANT USING CLINICAL METHODS (임상적 방법을 이용한 내부연결 임플랜트에서 고정체수준 인상법의 정확도 평가)

  • Choi Jung-Han
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.4
    • /
    • pp.421-431
    • /
    • 2006
  • Statement of problem : Accurate impression is essential to success of implant prostheses. But there have been few studies about the accuracy of fixture-level impression technique in internal connection implant system. Purpose: This study evaluated the accuracy of splinted fixture-level impression technique using clinical methods and the effect of internal hex on fit of superstructure in internal connection implant system (Astra Tech). Material and method : Two metal master frameworks made from two abutments (Cast-to Abutment ST) each for parallel and divergent conditions and a corresponding. passively fitting, dental stone master cast with four future replicas (Fixture Replica ST) were fabricated. Ten dental stone casts were made with vinyl polysiloxane impressions from the master cast by acrylic resin splinted fixture-level impression technique. To evaluate the accuracy of impression technique, the fit of master frameworks for test models was evaluated using screw resistance test (SRT) and one-screw test. The results of SRT were recorded as SRT values from grade 1 to grade 5 by 1/4 turn. And to evaluate the effect of hex on fit of superstructure, the same tests were performed after removing hexes of master frameworks. Results: 1. There was only one case (2.5%) showing SRT value of test model below ade 2 in total before and after removing hexes of master frameworks. And, by removing hexes. SRT values decreased in only one test model (5%) and did not change in 17 test models (85%). 2. SRT values of the 1$^{st}$ screws were grade 2 in 80% of cases before, and grade 1 in 80% of cases after removing hexes. And, by removing hexes, SRT values decreased in 72.5% of cases. 3. SRT values of the 2$^{nd}$ screws were grade 3 in 85% of cases before, and grade 3 in 95% of cases after removing hexes. And, by removing hexes, SRT values did not change in 85% of cases. 4. There were only 2 cases regarded as acceptable fit by one-screw test, and SRT values of 2$^{nd}$ screws of both cases were grade 2. Conclusion. Within the limitations of this study, future-level impression of internal connection implant system is considered to obtain inaccurate working cast, even using acrylic resin splinted impression technique. And, it is considered to be unable improve the fit to remove the hexes of implant restoration.

Full mouth rehabilitation with a few remaining teeth and implants for a patient with chronic periodontitis: a case report (만성 치주염 환자에서 소수 잔존치와 임플란트를 이용한 전악 수복: 증례 보고)

  • Shin, Eun-Jung;Vang, Mong-Sook;Yang, Hong-So;Park, Sang-Won;Lim, Hyun-Pil;Yun, Kwi-Dug
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.31 no.3
    • /
    • pp.253-261
    • /
    • 2015
  • Chronic periodontitis involves subsequent loss of teeth, and if left untreated, can lead to adjacent teeth drifting and supraeruption of the rest dentition. Careful consideration has to be given when deciding extraction of remaining teeth in treatment of periodontally compromised dentitions. For tooth-supported fixed partial dentures or removable partial dentures, periodontally compromised teeth are extracted due to possible early failure from functional overload, but for implant restoration, the teeth could be used as supports for fixed partial dentures because implants can reduce overload on teeth. The remaining natural teeth can help clinicians restoring vertical dimension and normal occlusal plane in full mouth rehabilitation because it conserves patients' proprioceptive response. This clinical report describes treatment of a patient who has a few remaining teeth and supraeruption of the rest dentition from severe chronic periodontitis. Satisfactory clinical result was achieved with full mouth rehabilitation using a few teeth and implants.

Tooth preparation design of dental laminate veneer: a review article (라미네이트 치아형성 디자인에 관한 문헌고찰)

  • Jo, Eun-Hye;Ko, Kyung-Ho;Park, Chan-Jin;Cho, Lee-Ra;Huh, Yoon-Hyuk
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.32 no.3
    • /
    • pp.149-157
    • /
    • 2016
  • Tooth preparation design is essential for successful laminate veneer treatment. Preservative tooth preparation limited on enamel, supra-margin advantageous for plaque control, and maintaining contact points known as a standard concept. However, the tooth preparation design has been the controversial issue. In biomechanical considerations, the incisal coverage should be decided on esthetic needs and necessity for the anterior guidance reconstruction. In occasion for sufficient enamel thickness, preparation can prolong to the palatal side but not recommended at palatal concavity. Elongation to contact point is selective option according to the cases. If an old resin restoration located at contact area, laminate veneer should cover over half area of that after surface treatment. The laminate veneer can be also selected at a partially discolored tooth root canal therapy (RCT) and at this occasion, the fiber-reinforced composite (FRC) posts are recommended.

TREATMENT OF DENTAL CARIES BY ER:YAG LASER IN CHILDREN (소아 환자에서 Er:YAG Laser를 이용한 우식 병소의 처치)

  • Jang, Eun-Young;Lee, Sang-Ho;Lee, Chang-Seop
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.27 no.4
    • /
    • pp.558-563
    • /
    • 2000
  • The lasers have been used in dentistry for more than 30 years and the application of lasers for drilling dental hard tissue has been investigated since the early developement of lasers. Recently, the Er:YAG laser was invented for hard tissue ablation. The Er:YAG laser, having a wavelength of 2.94um, is highly absorbed in both water and hydroxiapatite, leading to a very effective material for hard tissue removal by bursting off the solid tissue component that is, enamel and dentin are removed by the Er :YAG laser by water vaporization and microexplosion, without any melting of inorganic tissues. Therefore, the Er:YAG laser produced round craters with well defined margins and the surrounding tissues had no cracks and no charring. When used for cavity preparation, pulpal damage should not occur if hear buildup is minimized by careful selection of exposure parameters and by use of a water spray. The present study demonstrated that the Er:YAG laser cut the tooth substance adequately for composite resin restoration, without having undesirable side effects such as harmful effects on the pulp, discoloration or cracking etc. Also, the child patients were well cooperative during laser treatment mainly because of little noise, lesser vibration and minimal pain compared to conventional means of cavity preparation.

  • PDF