• Title/Summary/Keyword: Dental procedure

Search Result 926, Processing Time 0.032 seconds

Study of chitosan's effects on periodontal tissue regeneration: a meta-analysis of the histomorphometry (키토산의 치주조직 재생력에 대한 연구의 고찰: 조직계측학적 메타분석)

  • Yang, Jin-Hyuk;Chae, Gyung-Joon;Yun, Jeong-Ho;Jung, Ui-Won;Lee, Yong-Keun;Cho, Kyoo-Sung;Chai, Jung-Kiu;Kim, Chong-Kwan;Choi, Seong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • v.38 no.1
    • /
    • pp.7-14
    • /
    • 2008
  • Purpose: Chitosan & chitosan derivative(eg. membrane) have been studied in periodontal regeneration, and recently many studies of chitosan have reported good results. If chitosan's effects on periodontal regeneration are enhanced, we can use chitosan in many clinical and experimental fields. For this purpose, this study reviewed available literatures, evaluated comparable experimental models. Materials and Methods: Ten in vivo studies reporting chitosan's effects on periodontal tissue regeneration have been selected by use of the 'Pubmed' and hand searching. Results: 1. In Sprague Dawley rat calvarial defect models, amount of newly formed bone in defects showed significant differences between chitosan/chitosan-carrier/chitosan-membrane groups and control groups. 2. In beagle canine 1-wall intrabony defect models, amount of new cementum and new bone showed significant differences between chitosan/chitosan-membrane groups and control groups. The mean values of the above experimental groups were greater than the control groups. Conclusion: The results of this study have demonstrated that periodontal regeneration procedure using chitosan have beneficial effects, which will be substitute for various periodontal regenerative treatment area. One step forward in manufacturing process of chitosan membrane and in use in combination with other effective materials(eg. bone graft material or carrier) may bring us many chances of common use of chitosan in various periodontal area.

THE EFFECT OF 1.23% APF GEL ON THE ESTHETIC RESTORATIVE MATERIALS (APF Gel이 심미 수복재료의 표면에 미치는 영향)

  • Choi, Won-Hyuk;Kim, Eun-Jung;Kim, Hyun-Jung;Kim, Young-Jin;Nam, Soon-Hyeun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.33 no.2
    • /
    • pp.281-289
    • /
    • 2006
  • Topical fluoride application for children is a widely performed procedure in the field of Pediatric Dentistry for its dental caries prevention effects However, it is recently recognized as having some unwanted effects on several esthetic restorative materials, the author immersed glass ionomer cement, compomer and composite resin specimens in APF gel and measured the surface roughness and also, examined the specimens under the scanning eletron microscope. The followings are the results: 1. In the specimens of glass ionomer cement and compomer, APF gel 4 minute immersion group and pH cycling group show statistically significant increased surface roughness than artificial saliva immersion group (p<0.01). 2. There was no statistically significant surface roughness for composite resin in all group (p>0.05). 3. When the specimens were examined under scanning electron microscope, the surface change were in the order of glass ionomer cement, compomer, composite resin and also in the order of pH cycling group, APF gel 4 minutes immersion group, artificial saliva immersion group.

  • PDF

Development of A Fractionated Stereotactic Radiotherapy System (분할 정위방사선 치료 시스템 개발 연구)

  • 이동한;지영훈;이동훈;조철구;김미숙;유형준;류성렬
    • Progress in Medical Physics
    • /
    • v.13 no.1
    • /
    • pp.9-14
    • /
    • 2002
  • We invented the newly developed Fractionated Stereotactic Radiotherapy(F.S.R.T) system using combined techniques of couch mounting and pedestal mounting system. Head fixation frame consists of a milled alluminium alloy(duralumin) and is placed to the couch. This frame immobilized patient head using the dental bite, 3.2 mm frontal and occipital thermoplastic mask. To evaluate the coordinate of target isocenter, Brown-Revert-Walls C.T localizer can be attached to this frame. And also, we developed the frame mounting system by developing the modification of pedestal mounting system. This system is fixed to couch floor and can be used to evaluate the isocenteric accuracy of gantry, couch and collimator in Q.A procedure. In order to measure the relocation accuracy, the acrylic phantom and the accurate pointers have been made. The repositioning of the targets in the phantom were estimated by comparing C.T coordinates and E.C.L portal films taken with anterior-posterior and right-left direction. From the results of experiments, the average distance errors between the target isocenter and its mean position were 0.71$\pm$0.19 for lateral, 0.45$\pm$0.15 for inferior-superior, 0.63$\pm$0.18 for anterior-posterior. And the maximum distance error was less than 1.3 mm. The new head fixation frame and frame mounting system were non-invasive, accurately relocatable, easy to use, very light and well tolerable by the results of phantom tests. The major advantage of using this frame mounting system is complete access to any point in the Patients cranium especially posterior direction

  • PDF

The Study of Bone Formation around Titanium Implants Placed in Adrenalectomized Rat's Tibia (부신 제거 백서에 티타늄 임플랜트 매식후 주위 골형성에 관한 연구)

  • Choi, Kab-Lim;Kim, Jong-Ryoul;Park, Bong-Soo;Sung, Iel-Yong
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.22 no.3
    • /
    • pp.274-287
    • /
    • 2000
  • The use of dental implants has increased tremendously in recent years and is expected to increase even more in the future. The successful outcome of any implant procedure is surely dependent on interrelationship of the various components of an equation that includes biocompatibility of implant material, macroscopic and microscopic nature of the implant surface, the status of implant bed, surgical technique, undisturbed healing phase and subsequent prosthetic design and long-term loading phase. The purpose of this study was to clarify the effects of adrenalectomy on the osseointegration of pure titanium implants. Seventy rats, 11 weeks of age, were divided into two groups : an adrenalectomized group and a control group. Titanium screw implant(diameter, 2.0mm; length, 3.5mm) was placed into left tibia of 70 rats, 35 in control group and 35 in the experimental group. The rats were sacrificed at different time interval (1, 2, 3, 4, 6, 8, and 12 weeks after implantation) for histopathologic observation, histomorphometric analysis and immunohistochemistry with fibronectin and CD44 antibody. The results obtained from this study were as follows: 1. Histopathogically, findings, newly formed bone was seen at 3 weeks control group and became lamellar bone at 12 weeks. At 6 weeks, lipocytes were observed in bone marrow space. Thickness of regenerated trabecular bone increased till 6 weeks after then, that decreased gradually. 2. By histomorphometric analysis, marrow bone density and contact ratio of marrow bone to implant decreased significantly from 8 to 12 weeks in experimental group compared to control group and also total bone to implant contact ratio decreased significantly from 4 to 12 weeks in experimental group compared to control group. 3. Fibronectin immunoreactivity was very strong at 3 and 4 weeks control group. And after that reduced gradually. But it was continuously strong from 1 to 12 weeks experimental group. 4. CD44 immunoreactivity was very strong in the newly formed osteoblasts at 3 and 4 weeks control group. But it reacted minimally later. However, it reacted continuously strong from 3 to 12 weeks experimental group. From these results, bone to implant contact ratio decreased gradually from 4 weeks in adrenalectomized group compared to control group. CD44 and fibronectin immunoreactivities were strong at all times in adrenalectomized rats. Therefore, it could be stated that immature bone remained continuously for a long time and not readily proceeded into mature status.

  • PDF

An Electrophysiologic Study on the Median Motor Nerve and Ulnar Motor Nerve (정중운동신경과 척골운동신경의 전기생리학적 연구)

  • Kim, Jong-Soon;Lee, Hyun-Ok;Ahn, So-Youn;Koo, Bong-Oh;Nam, Kun-Woo;Kim, Young-Jick;Kim, Ho-Bong;Ryu, Jae-Kwan;Ryu, Jae-Moon
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.11 no.2
    • /
    • pp.62-70
    • /
    • 2005
  • The determination of peripheral nerve conduction velocity is an important part to electrodiagnosis. Its value as neurophysiologic investigative procedure has been known for many years but normal value of median and ulnar motor nerve was poorly reported in Korea. To evaluate of median and ulnar motor nerve terminal latency, amplitude of CMAP(compound muscle action potential), conduction velocity and F-wave latency for obtain clinically useful reference value. 71 normal volunteers(age, 19-65 years; 142 hands) examined who has no history of peripheral neuropathy, diabetic mellitus, chronic renal failure, endocrine disorders, anti-cancer medicine, anti-tubercle medicine, alcoholism, trauma, radiculopathy. Nicolet Viking II was use for detected terminal latency, amplitude of CMAP, conduction velocity and F-wave latency of median and ulnar motor nerve. Data analysis was performed using SPSS. Descriptive analysis was used for obtain mean and standard deviation, independent t-test was used to compare between Rt and Lt side also compare between different in genders. The results are summarized as follows: 1. Median motor nerve terminal latency was right 3.00ms, left 2.99ms and there was no significantly differences between right and left side and genders. 2. Median motor nerve amplitude of CMAP was right 17.26mV, left 1750mV and there was no significantly differences between right and left side and genders. 3. Median motor nerve conduction velocity was right 57.89m/sec, left 58.03m/sec and there was no significantly differences between right and left side and genders. 4. Median motor nerve F-wave latency was right 25.74ms, left 25.59ms and there was significantly differences between genders. 5. Ulnar motor nerve terminal latency was right 2.38ms, left 2.45ms and there was significantly differences between right and left side. 6. Ulnar motor nerve amplitude of CMAP was right 15.99mV, left 16.02mV and there was no significantly differences between right and left side and genders. 7. Ulnar motor nerve conduction velocity was right 60.35m/sec, left 59.73m/sec and there was no significantly differences between right and left side and genders. 8. Ulnar motor nerve F-wave latency was right 25.53ms, left 25.57ms and there was significantly differences between genders.

  • PDF

SPECTROPHOTOMETRIC ANALYSIS OF THE INFLUENCE OF METAL SUBSTRATE ON THE COLOR OF CERAMIC (금속하부구조물이 도재의 색조에 미치는 영향에 대한 분광측색분석)

  • Lee Su-Ok;Woo Yi-Hyung;Choi Dae-Gyun;Kwon Keung-Rok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.2
    • /
    • pp.148-159
    • /
    • 2003
  • Statement of problem Metal-ceramic restorations have been used extensively by dental clinicians for nearly 40 years. Strength an functional ability of metal-ceramic restorations are proved to be satisfying, However esthetics and biocompatibility of metal alloy which is used in metal-ceramic restoration is not ideal. Using pure gold as an alternative, have advantage of esthetics, biocompatibility over conventional metal alloy. But there had been little article which studied on the color effect of pure gold on fual porcelain color. Purpose The purpose of this study was to spectrophotometrically evaluate the difference between color of metal alloy(Au-Pt, Ni-Cr) and pure gold, during color masking procedure with opaque porcelain and to analyze the differences, Material and Methods Three types of metal - base metal(Ni-Cr), high gold alloy(Au-Pt), pure gold(GES) - specimen were fabricated 1cm in diameter. Four steps were established - after finishing, after pre-coditioning, after application of first opaque porcelain(0.08mm in thickness), after application of second opaque porcelain(0.15mm in thickness)- and tested color with spectrophotometer every each steps and analyzed with $CIEL^*a^*b^*$ color order system. One-Way ANOVA test was used to and out if there were significant differences between groups tested and Shaffe multiple comparison was used to identify where the differences were. Results 1. After finishing and pre-conditioning, pure gold(GES) group showed most high values in $L^*,a^*,b^*$. 2. After application of first opaque porcelain(0.08mm in thickness), after application of second opaque porcelain(0.15mm in thickness), pure gold(GES) group showed the least difference in $L^*,a^*,b^*$ values and the lowest ${\Delta}E$ value(${\Delta}E$=0.63). 3. After application of first opaque porcelain and after application of second opaque porcelain differences that were significant (P<0.05) between groups were found only in $a^*$ values. 4. Base metal alloy group showed the lowest $a^*$ value in test after application of first opaque porcelain and the highest value in test after application of first opaque porcelain Conclusion Pure gold group and high gold group showed higher $a^*$ values than base metal group when tested after 0.08mm thickness of opaque porcelain was applied and pure gold group showed much similar $L^*,a^*,b^*$ values between 0.08mm thickness and 0.15mm thickness of opaque porcelain. This meant that pure gold was more easily masked by opaque porcelain than the other two groups.

Evaluation of the wear of the periodontal curet's cutting edge (치주 큐렛의 절단 연 마모도 평가)

  • Park, Eung-Joon;Lim, Sung-Bin;Chung, Chin-Hyung
    • Journal of Periodontal and Implant Science
    • /
    • v.27 no.3
    • /
    • pp.575-584
    • /
    • 1997
  • The quality of periodontal instrument cutting edge is a basic element of effective root planing procedure. Using instruments, the sharp edge is changed into blunt or beveled edge. With the blunt instrument, the periodontal treatment can't be carried into accuracy and effective. The study on the wear of periodontal curet is insufficient, there are few publications about the change of sharpness of cutting egde after using instrument and a certen reports were published on the study of scanning electron microscope(SEM) examination. In this study, to declare the number of strokes for sharpening of instruments, the changes of cutting edge is measured by the clinical methods, tactile sensitivity examination and refraction light-white line test after scaling strokes and root planing strokes. SEM test was added for defined the changes of cutting edges. The 7/8 Gracey curets that have been never used was tested. Maxillary molars which were extracted from the School of Dental Medicine, Dankook University was used. Subjected teeth had attachment loss more than 6 mm in bucca-lingual surface and sufficient calculus of a band type in cervical area. The strokes of curet were executed 3, 5, 7, 9, 11, 13 times on scaling stroke and 10, 15, 20, 25, 30, 35 times on root planing stroke. A resident has periodontal experience over 3 years carried out the clinical examinations those tactile sensitivity examination and refraction light-white line test 5 times. The case there being tactile sensitivity certenly is 2, the case being felt tactile sensitivity is 1, and the case there not being tactile sensitivity is 0. The visual examination was recorded as following. The case that refracted white line is not recognised is 2, the case that uncerten is 1, and the case that acknowledged is 0. The results were obtained as follows. 1. After scaling strokes, the tactile sensitivity was reduced after 11 strokes and disappeared in 13 strokes. 2. In tactile sensitivity after root planing procedures, sensitivity was reduced after 25 strokes and disappeared in 35 strokes. 3. In case of visual examination, the detection of refracted white line was increased after 9 strokes of scaling procedures and the accuracy of wear wasn't showed after root planing procedures. 4. In SEM, metal projection was observed on new periodontal curet cutting edge and it was disappeared after scaling procedures. 5. In SEM, the cutting edge was showed changing linear into an aspect of the surface after 5 strokes of scaling procedures and 10 strokes of root planing procedures and showed beveled edge in 11 strokes of scaling procedures, 25 strokes of root planing procedures. The results of 3-type examination indicated that the sharpening of curet should be performed after 11 strokes of scaling procedures and 25 strokes of root planing procedures.

  • PDF

A Study of Prosthetic Prescriptions sent to the Laboratories for Removable Partial Denture Framework (국부의치 제작을 위한 보철의뢰 서식의 기록에 관한 임상적 연구)

  • Chang, Ik-Tae
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.18 no.1
    • /
    • pp.7-13
    • /
    • 1980
  • The purpose of this study was to evaluate the removable partial denture prescriptions including surveyed crowns and design of component parts sent to the laboratory technician. A total of 351 casess with prescription forms and master cast in maxillary and mandibular semi-edentulous situations collected from dental laboratory by random sampling were selected for this study. The evaluation and study observed here involved the classification of edentulous situations, status of abutment splinting, form of rest seats and guiding plane of surveyed crows, location of maxillary major connectors and tripodig marks on the master casts. Removable partial denture prescriptions contained (1) general request (upper and lower cast framework), (2) types of metal, (3) location of retainer(retention, lingual bracing, rest area, guiding plane surface), (4) location and type of major connector, (5) relief area and amount, (6) and other specific instructions. The following informations based on the classified groups such as Group I was those cases sent with no real prescriptions. They say 'make a partial.' No prescriptions, no thought beforehand, Group II was those cases sent with a minimal prescriptions. They say 'make a partial with clasps on May be some preparations, usually inadequate. Group III was those cases sent with a moderately good prescription. Adequate but could be much better. No tripoding but it tell what clasps go where. Still not good prescriptions. Group IV was good cases, tripoded with adequate prescriptions and a prescription which exactly describes what is expected from the laboratory. The analyzed results were as follows: 1. The normal form of rest seats and guiding plane of surveyed crowns in Class. I and Class. II edentulous situations on the maxillary cast were observed 31.9% and 27.89%, respectively. The abutment teeth and retainer without occlusal rests of Class. I and Class. II were showed 11.58% and 8.86%, respectively. In mandibular cases, the normal form of rest seats and guiding plane of surveyed crowns showed 27.54% and 8.82% in Class. I and Class. II situation. The abutment teeth and retainer without rest seats were showed 15.19%, respectively. 2. The splinted surveyed crowns of Class. I and Class. II maxillary edentulous situations in distal extension cases were showed 34.51% and 28.85%, but 28.52% and 10.29%, respectively. 3. The location and type of maxillary major connector delineated on the master cast were 66 cases (44.89%). 4. The results of 351 cases were classified as Group I 146(41.59%), Group II 115 (32.76%), Group III 57 (16.23%), and Group IV 33 (9.48%). 5. The delineation of abutment tooth for clasping were 176 cases (50.14%) among total of 351 cases. 6. The delineation of height of contour line were showed 45 cases (12.8%) in Group II, 14 cases (3.98%) in Group III and 33 cases (9.40%) in Group IV with total 92 cases (26.21%). 7. In surveying procedure, the delineation of tripoding marks and reference line were showed 17 cases (4.84%).

  • PDF

Photoelastic Stress Analysis of Fixed Partial Dentures (가공의치(架工義齒)에 작용(作用)하는 Stress에 관(關)한 광탄성학적(光彈性學的) 분석(分析))

  • Cho, Won-Haeng
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.18 no.1
    • /
    • pp.15-35
    • /
    • 1980
  • The purpose of this study was to investigate stresses in the various components of fixed partial dentures restoring the posterior teeth of the lower jaw, and to measure quantitatively the effects of certain modifications in structural design on the stresses in the restorations using two-dimensional photoelasticity. Two-dimensional photoelastic methods were used in this study. Several models of fixed partial dentures were constructed. Shoulder less margins and anatomic occlusal reduction were incorporated in Model 1. Rounded shoulders and flat occlusal reduction were incorporated in Model 2, while Model 3 was a cantilever fixed partial denture. Other similar fixed partial dentures were constructed with V and U notches deliverately included in the region of the fixed joints for comparative reasons. The birefringent materials used in this study were PSM-1 and PSM-5 in standard sheets. PSM-1 was used for constructing the substructure, and PSM-5 was used in making the components of the fixed partial dentures. The two materials were used in the construction of composite photoelastic models. Improved artificial stone was used to represent dental cement in luting the composite photoelastic models. Static loading procedures were used at preplanned sites to represent occlusal loads in the mouth. 35 mm color and B/W film were used to record isochromatics in accordance with photoelastic procedures. Data reduction was performed using the grid method, which helped in, the mathematical integration procedure (Shear difference method) to separate the principal stresses. The results were as follows. 1. Fixed partial dentures do not function in bending as a symmetrical beam. Alternate areas of tension and compression were demonstrated when multiple contact loading was used. 2. The weakest part in posterior fixed partial dentures is the fixed joint. 3. (1) Models I and modified Model I were loaded on the pontic using a 50 pound vertical static load. The shear stress near the posterior fixed joint in Model 1 (U notches) was+129.4 p.s.i., and at the same fixed joint in modified Model 1 (V notches) was+239.4 p.s.i. The concentration of stress in fixed joint was reduced by 50% when U notches replaced the V notches. (2) Modified Model 2 was loaded using a multiple contact loader at a total load of 125 pounds. The difference between the principal stresses (${\sigma}_1-{\sigma}_2$), shear stress, at the V notches was+600 p.s.i., and at the U notches was+3l7 p.s.i. The shear stress was reduced by 50% when U notches replaced the V notches. V-grooves at the fixed joints should be avoided, and should be replaced by regular shaped U-grooves. 4. Cantilever fixed partial dentures had much higher stresses at the fixed joint than fixed partial dentures that were attached at both ends.

  • PDF

Full mouth rehabilitation of a partially edentulous patient with crossed occlusion using implant-retained RPD with zirconia occlusal table (엇갈린 교합을 가진 부분 무치악 환자에서 지르코니아 교합면을 가지는 Implant-Retained RPD 이용한 전악 수복 증례)

  • Kwon, Tae-Min;Seo, Chi-Won;Kim, Kyung-A;Ahn, Seung-Geun;Seo, Jae-Min
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.32 no.4
    • /
    • pp.314-321
    • /
    • 2016
  • Conventional removable partial dentures (RPDs) with distal extensions are associated with some problems, including lack of stability that calls for frequent relining, and cantilever actions of claps that can produce excessive loading to abutment teeth, and the need for unesthetic retentive arm clasps. Therefore, IARPDs (Implant-assisted RPD) that use implants to support or retain RPDs has been reported to improve stability, esthetics and masticatory performance of RPDs. Also, an IARPD that has zirconia occlusal table can prevent the incongruity of occlusal plane and the extrusion of antagonistic tooth. In this case of partially edentulous patient with crossed occlusion, each edentulous area was restored with implant fixed prosthesis and implant retained partial denture to suit each situation. Through the procedure, satisfactory outcomes were achieved both in functional and esthetic aspects.