• 제목/요약/키워드: Dental marginal adaptation

검색결과 52건 처리시간 0.032초

Comparison of three-dimensional digital technique with two-dimensional replica method for measuring marginal and internal fit of full coverage restorations

  • Hasanzade, Mahya;Koulivand, Soudabeh;Moslemian, Naeime;Alikhasi, Marzieh
    • The Journal of Advanced Prosthodontics
    • /
    • 제12권3호
    • /
    • pp.173-180
    • /
    • 2020
  • PURPOSE. This study compared digital (reference point matching) and replica methods for measuring marginal and internal fit of full coverage restorations. MATERIALS AND METHODS. A maxillary left first molar typodent was fixed on to an aluminum base and prepared to receive all-ceramic full coverage restoration. The model was scanned with an intraoral scanner (CEREC Omnicam, Sirona, York, PA, USA). Twelve crowns were fabricated from lithium disilicate blocks (IPS emax CAD, Ivoclar Vivadent) and then crystalized. Marginal and internal fit of each restoration was measured by two examiners using replica and a new digital three-dimensional technique. Reliability between the two methods and two examiners was assessed by correlation and Cronbach's Alpha coefficient (P<.05). A Bland-Altman assessment for agreement was used to compare the two methods. RESULTS. Bland-Altman assessment showed that the mean of difference for marginal, absolute marginal, and axial gap was respectively -1.04 ㎛, -41.9 ㎛, and -29.53 ㎛ with limit of agreement (LOA) between -37.26 to 35.18 ㎛ for marginal, -105.85 to 22.05 ㎛ for absolute marginal and -80.52 to 22.02 ㎛ for axial gap. Positive correlation for repeatability (P<.05) in determining marginal and internal gaps by the two examiners in both techniques was revealed. Reliability of both techniques in all sites of measurements was at least good (0.8 ≤ α < 0.9). CONCLUSION. Both measuring techniques appeared highly reliable for evaluating fit of fixed dental restorations, while reference point matching provided higher values in axial and absolute marginal gap assessment.

The use of definitive implant abutments for the fabrication of provisional crowns: a case series

  • Bilhan, Hakan;Geckili, Onur;Mumcu, Emre
    • Journal of Periodontal and Implant Science
    • /
    • 제41권5호
    • /
    • pp.248-252
    • /
    • 2011
  • Purpose: The anterior region is a challenge for most clinicians to achieve optimal esthetics with dental implants. The provisional crown is a key factor in the success of obtaining pink esthetics around restorations with single implants, by soft tissue and inter-proximal papilla shaping. Provisional abutments bring additional costs and make the treatment more expensive. Since one of the aims of the clinician is to reduce costs and find more economic ways to raise patient satisfaction, this paper describes a practical method for chair-side fabrication of non-occlusal loaded provisional crowns used by the authors for several years successfully. Methods: Twenty two patients (9 males, 13 females; mean age, 36,72 years) with one missing anterior tooth were treated by using the presented method. Metal definitive abutments instead of provisional abutments were used and provisional crowns were fabricated on the definitive abutments for all of the patients. The marginal fit was finished on a laboratory analogue and temporarily cemented to the abutments. The marginal adaptation of the crowns was evaluated radiographically. Results: The patients were all satisfied with the final appearance and no complications occurred until the implants were loaded with permanent restorations. Conclusions: The use of the definitive abutments for provisional crowns instead of provisional abutments reduces the costs and the same results can be obtained.

유구치 기성 금관의 변연 적합도에 관한 연구 (MARGINAL ADAPTATION OF STAINLESS STEEL IN POSTERIOR PRIMARY TOOTH)

  • 우주형;장철호;김정욱;장기택;김종철
    • 대한소아치과학회지
    • /
    • 제34권1호
    • /
    • pp.27-35
    • /
    • 2007
  • 본 연구의 목적은 발거된 기성 금관 수복 유구치를 대상으로 변연 적합도를 관찰 분석하는 것이다. 서울대학교 치과병원 소아치과에서 수거한 3M사의 기성 금관 수복 유구치를 대상으로 하였다. 상악 제 1유구치 42개, 상악 제 2유구치 25개, 하악 제 1유구치 37개, 하악 제 2유구치 28개를 대상으로 기성 금관의 변연에 따라 치근을 절단한 후 단면을 Fine Pix S602 디지털 카메라로 촬영한 후 Kappa image base program을 이용해 우각 부위 및 임의로 20부분의 변연 간격과 전체 기성 금관 면적 중 변연 간격의 면적이 이루는 비율을 측정하여 다음과 같은 결과를 얻었다. 1. 평균 변연 간격은 상악 제 2유구치, 하악 제 1유구치, 하악 제 2유구치, 상악 제1 유구치 순으로 높았다 (P<0.05). 2. 평균 변연 간격 면적의 비율은 치아의 종류에 관계없이 약 20%를 상회하는 값을 보였다. 3. 상악 제 1,2유구치에서는 근심면의 변연 간격이 가장 컸고, 하악 제 1유구치에서는 원심 설면, 하악 제 2유구치에서는 협면에서 변연 간격이 가장 큰 값을 보였다.

  • PDF

주조티타늄과 기계절삭티타늄 코핑의 변연적합성에 관한 연구 (THE STUDY ABOUT THE MARGINAL FIT OF THE CASTING TITANIUM AND MACHINE-MILLED TITANIUM COPINGS)

  • 오수연;방몽숙;양홍서;박상원;박하옥
    • 대한치과보철학회지
    • /
    • 제44권1호
    • /
    • pp.20-28
    • /
    • 2006
  • Statement of problem: The titanium has advantages of a high biocompatibility, a corrosion resistence, low density, and cheep price, so it is focused as a substituted alloy But it is quite difficult to cast with the tranditional method due to the high melting point, reacivity with element at, elevated temperature. By using the CAD-CAM system for the crown construction, it is possible to reduce the errors while proceeding the wax-up, investing, and casting procedure Purpose: The purposes of this study were to measure the marginal adaptation of the casting titanium coping and machine-milled titanium coping according to the casting methods and the marginal configurations. Material and method: The marginal configurations were used chamfer shoulder, and beveled shoulder. The total 30 copings were used, and these are divided into 6 groups according to the manufacturing method and marginal configuration. The gap between margin of the model and the restoration was measured with 3-dimensional measuring microscope. Results: The following results were obtained; 1. casting gold coping demonstrated the best marginal seal, followed by casting titanium coping finally machine-milled titanium copings. 2. In casting titanium coping, chamfer demonstrated the best marginal seal, followed by shoulder and beveled shoulder. There was no significantly difference in shoulder and beveled shoulder. But all margin form has clinically acceptable 3. In machine-milled titanium copings, chamfer demonstrated the best marginal seal, followed by shoulder and beveled shoulder. Beveled shoulder show large and uneven marginal gap Conclusions: Above result revealed that marginal adaptation of the titanim coping is avail able in the clinical range, it can be used as an alternative metal and it is prefered especially in chamfer or shoulder margin during implant superstructure fabrication. But there should be more research on machine-milled titanium in order to use it in the clinics.

Evaluation and comparison of the marginal adaptation of two different substructure materials

  • Karaman, Tahir;Ulku, Sabiha Zelal;Zengingul, Ali Ihsan;Guven, Sedat;Eratilla, Veysel;Sumer, Ebru
    • The Journal of Advanced Prosthodontics
    • /
    • 제7권3호
    • /
    • pp.257-263
    • /
    • 2015
  • PURPOSE. In this study, we aimed to evaluate the amount of marginal gap with two different substructure materials using identical margin preparations. MATERIALS AND METHODS. Twenty stainless steel models with a chamfer were prepared with a CNC device. Marginal gap measurements of the galvano copings on these stainless steel models and Co-Cr copings obtained by a laser-sintering method were made with a stereomicroscope device before and after the cementation process and surface properties were evaluated by scanning electron microscopy (SEM). A dependent t-test was used to compare the mean of the two groups for normally distributed data, and two-way variance analysis was used for more than two data sets. Pearson's correlation analysis was also performed to assess relationships between variables. RESULTS. According to the results obtained, the marginal gap in the galvano copings before cementation was measured as, on average, $24.47{\pm}5.82{\mu}m$ before and $35.11{\pm}6.52{\mu}m$ after cementation; in the laser-sintered Co-Cr structure, it was, on average, $60.45{\pm}8.87{\mu}m$ before and $69.33{\pm}9.03{\mu}m$ after cementation. A highly significant difference (P<.001) was found in marginal gap measurements of galvano copings and a significant difference (P<.05) was found in marginal gap measurements of the laser-sintered Co-Cr copings. According to the SEM examination, surface properties of laser sintered Co-Cr copings showed rougher structure than galvano copings. The galvano copings showed a very smooth surface. CONCLUSION. Marginal gaps values of both groups before and after cementation were within the clinically acceptable level. The smallest marginal gaps occurred with the use of galvano copings.

지대치 형태에 따른 지르코니아 코어의 변연 적합도 (Marginal Adaptation of Zirconium Dioxide Core according to the Abutment Teeth)

  • 김기백;김석환;김재홍
    • 치위생과학회지
    • /
    • 제15권1호
    • /
    • pp.54-59
    • /
    • 2015
  • 본 연구는 시중에 널리 사용되는 치과용 지르코니아 코어를 이용하여 서로 다른 형태의 지대치를 대상으로 작업모형을 제작한 후, 치과용 스캐너를 통해 3차원 디지털 모형을 전환한 데이터를 토대로 지르코니아 코어를 제작하였으며, 각 실험군별 변연 적합도를 측정하여 비교분석하고자 하였다. 이와 같은 결과로 형태가 다른 지대치가 CAD/CAM system으로 치과 보철물 제작 시 적합도의 영향여부를 비교하였다. 제한된 조건 하에서 수행된 본 연구에서 다름과 같은 결과를 보였다. 지대치의 형태가 다른 작업모형으로 제작된 지르코니아 코어의 변연 적합도는 큰 차이가 없었다(p>0.05). 작업모형의 부위를 4등분으로 나누어 측정한 변연 적합도 또한 통계적으로 유의한 차이를 보이지 않았다. 결론적으로 3종류의 다른 지대치 모두 유사한 지르코니아 코어의 변연 적합도를 보였으며, 측정된 결과는 선행연구에 비추어 볼 때 임상적으로 허용 가능한 수치($100{\sim}120{\mu}m$)를 초과하는 실험군은 없었다. 이와 같은 결과를 토대로 다른 형태의 지대치를 사용하여 제작되었더라도 지르코니아 코어의 변연 적합도에 큰 영향을 주지 않을 것으로 생각된다.

접착형 아말감의 2년 후 임상적 평가 (CLINICAL EVALUATION OF AMALGAM BONDING : TWO YEARS FOLLOW-UP)

  • 유필준;한세현;김종철
    • 대한소아치과학회지
    • /
    • 제28권3호
    • /
    • pp.530-534
    • /
    • 2001
  • 많은 치과 임상가들은 아말감을 치질에 접착시키기 위해서 여러 접착재료를 이용해왔다. 이 런 술식의 장점으로는 미세누출의 감소로 인한 술후과민증의 감소, 변연파절의 감소, 삭제 후 치질의 강화, 적은 유지형태에서의 수복물의 유지등이 제시되어 왔다. 실제로 임상적 상황에서 이러한 술식의 장점을 확인할 필요가 있다. 이런 접착제가 임상적 환경에서 어떠한 잇점을 보이지 않는다면 시간과 비용을 낭비하는 이런 술식을 정당화하지 못할 것이다. 본 연구에서는 73개의 치아를 대상으로 하여 I급 와동과 II급 와동에 접착형과 비접착형 아말감으로 수복하였다. 접착제로는 Fuji I Glass Ionomer luting cement를 이용하였다. 평균 2년 후에 변연적합성을 평가하였으나 접착형 아말감과 비접착형 아말감 사이에 유의한 차이는 없었다.

  • PDF

SLM 방식으로 제작한 도재관 금속하부구조물의 변연 및 내면 적합도 평가 (Evaluation of marginal and internal fit of metal copings fabricated by selective laser melting)

  • 배성령;이하빈;노미준;김지환
    • 대한치과기공학회지
    • /
    • 제45권1호
    • /
    • pp.1-7
    • /
    • 2023
  • Purpose: To evaluate the marginal and internal fit of metal coping fabricated by a metal three-dimensional (3D) printer that uses selective laser melting (SLM). Methods: An extraoral scanner was used to scan a die of the prepared maxillary right first molar, and the coping was designed using computer-aided design software and saved as an stereo lithography (STL) file. Ten specimens were printed with an SLM-type metal 3D printer (SLM group), and 10 more specimens were fabricated by casting the castable patterns output generated by a digital light processing-type resin 3D printer (casting the 3D printed resin patterns [CRP] group). The fit was measured using the silicon replica technique, and 8 points (A to H) were set per specimen to measure the marginal (points A, H) and internal (points B~G) gaps. The differences among the groups were compared using the Mann-Whitney U-test (α=0.05). Results: The mean of marginal fit in the SLM group was 69.67±18.04 ㎛, while in the CRP group was 117.10±41.95 ㎛. The internal fit of the SLM group was 95.18±41.20 ㎛, and that of the CRP group was 86.35±32 ㎛. As a result of statistical analysis, there was a significant difference in marginal fit between the SLM and CRP groups (p<0.05); however, there was no significant difference in internal fit between the SLM group and the CRP group (p>0.05). Conclusion: The marginal and internal fit of SLM is within the clinically acceptable range, and it seems to be applicable in terms of fit.

Biomechanical behavior of CAD/CAM cobalt-chromium and zirconia full-arch fixed prostheses

  • Barbin, Thais;Silva, Leticia Del Rio;Veloso, Daniele Valente;Borges, Guilherme Almeida;Presotto, Anna Gabriella Camacho;Barao, Valentim Adelino Ricardo;Groppo, Francisco Carlos;Mesquita, Marcelo Ferraz
    • The Journal of Advanced Prosthodontics
    • /
    • 제12권6호
    • /
    • pp.329-337
    • /
    • 2020
  • PURPOSE. To verify the influence of computer-aided design/computer-aided manufacturing (CAD/CAM) implant-supported prostheses manufactured with cobalt-chromium (Co-Cr) and zirconia (Zr), and whether ceramic application, spark erosion, and simulation of masticatory cycles modify biomechanical parameters (marginal fit, screw-loosening torque, and strain) on the implant-supported system. MATERIALS AND METHODS. Ten full-arch fixed frameworks were manufactured by a CAD/CAM milling system with Co-Cr and Zr (n=5/group). The marginal fit between the abutment and frameworks was measured as stated by single-screw test. Screw-loosening torque evaluated screw stability, and strain analysis was explored on the implant-supported system. All analyses were performed at 3 distinct times: after framework manufacturing; after ceramic application in both materials' frameworks; and after the spark erosion in Co-Cr frameworks. Afterward, stability analysis was re-evaluated after 106 mechanical cycles (2 Hz/150-N) for both materials. Statistical analyses were performed by Kruskal-Wallis and Dunn tests (α=.05). RESULTS. No difference between the two materials was found for marginal fit, screwloosening torque, and strain after framework manufacturing (P>.05). Ceramic application did not affect the variables (P>.05). Spark erosion optimized marginal fit and strain medians for Co-Cr frameworks (P<.05). Screw-loosening torque was significantly reduced by masticatory simulation (P<.05) regardless of the framework materials. CONCLUSION. Co-Cr and Zr frameworks presented similar biomechanical behavior. Ceramic application had no effect on the biomechanical behavior of either material. Spark erosion was an effective technique to improve Co-Cr biomechanical behavior on the implant-supported system. Screw-loosening torque was reduced for both materials after masticatory simulation.

다른 스캐닝 방법으로 제작된 리튬 디실리케이트 단관의 변연 및 내면 적합도 평가 (Evaluation of the marginal and internal fit of lithium disilicate crowns fabricated by different scanning methods)

  • 김재홍;김웅철;김지환
    • 대한치과기공학회지
    • /
    • 제36권2호
    • /
    • pp.75-81
    • /
    • 2014
  • Purpose: This study was to compare adaptations of lithium disilicate CAD/CAM crowns fabricated with different scanning systems. Methods: This study selected the mandibular right first molar as an abutment for experiments and produced 10 working models. Lithium disilicate crowns appropriate for each abutment were produced by using a CEREC$^{(R)}$ CAD/CAM system. The independent t-test was then used to compare and analyze the data obtained from the two groups(${\alpha}$=0.05). Results: Mean(SD) adaptation were $86.93(22.82){\mu}m$ for the InS group, $88.42(26.77){\mu}m$ for the ExS group. They were no statistically significant differences between groups for adaptation(p>0.05). Conclusion: Within the limitations of this study, the results suggest that the accuracy of all investigated optical scanner were satisfactory for clinical use. Further assessment and improvement of the lithium disilicate ceramic for the fabrication of FPDs is evidently still required.