• Title/Summary/Keyword: Dental impression

Search Result 348, Processing Time 0.022 seconds

Study on the Effect of Contact Angles of Elastic Rubber Impression Materials on the Surface of Working Cast (탄성 고무인상재의 접촉각이 작업모형 표면에 미치는 영향)

  • Kim, Joo-Won
    • Journal of dental hygiene science
    • /
    • v.10 no.3
    • /
    • pp.177-183
    • /
    • 2010
  • This study was begun to search effect of contact angles of elastic rubber impression materials on the surface of working cast. Of elastic rubber impression materials with a Type III consistency, such as polysulfide, polyether and addition silicone, we selected one and then measured the contact angle after dripping a distilled water 3.3ml. Then, after pouring a dental anhydrite in three types of impression materials, we prepared a working cast and then examined its surface. Contact angle was measured using a full automatic contact angle measuring system (DM-700, KYOWA, Japan), and the surface of working cast was observed using a field emission scanning electron microscope (JSM-6700F, JEOL Ltd., JAPAN). The following results were obtained: 1) $Mean{\pm}SD$ (SD: standard deviation) of the initial contact angles were $91.3{\pm}20.5^{\circ}$ in the addition silicone materials, $90.0{\pm}2.2^{\circ}$ in the polyethers and $101.5{\pm}2.3^{\circ}$ in the polysulfides. These results indicate that mean values were similar but standard deviations of the three materials showed a great discrepancy. 2) As the time elapsed, addition silicone materials were found to have a contact angle decreased abruptly as compared with the remaining two types. That is, the initial contact angle was $91.3^{\circ}$ and it was abruptly decreased to $29.4^{\circ}$ after 25 seconds. 3) In the polyethers, the initial contact angle was $101.5^{\circ}$ and it was decreased to $90.7^{\circ}$ after 25 seconds. In the polysulfides, however, the initial contact angle was $90.0^{\circ}$ and it was $84.2^{\circ}$ after 25 seconds. This showed almost no changes in the initial contact angles. Moreover, its magnitude was greater than that seen in additional silicones. 4) There were significant differences in the contact angles between the three types of elastic rubber impression materials as the time elapsed (p<0.001). On an observation on the surface of working cast, addition silicone materials were found to have the most dense surface. This was followed by polysulfides and polyethers in a descending order.

Reverse engineering technique on the evaluation of impression accuracy in angulated implants (경사진 임플란트에서 임플란트 인상의 정확도 평가를 위한 역공학 기법)

  • Jung, Hong-Taek;Lee, Ki-Sun;Song, So-Yeon;Park, Jin-Hong;Lee, Jeong-Yol
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.3
    • /
    • pp.261-270
    • /
    • 2021
  • Purpose. The aim of this study was (1) to compare the reverse engineering technique with other existing measurement methods and (2) to analyze the effect of implant angulations and impression coping types on implant impression accuracy with reverse engineering technique. Materials and methods. Three different master models were fabricated and the distance between the two implant center points in parallel master model was measured with different three methods; digital caliper measurement (Group DC), optical measuring (Group OM), and reverse engineering technique (Group RE). The 90 experimental models were fabricated with three types of impression copings for the three different implant angulation and the angular and distance error rate were calculated. One-way ANOVA was used for comparison among the evaluation methods (P < .05). The error rates of experimental groups were analyzed by two-way ANOVA (P < .05). Results. While there was significant difference between Group DC and RE (P < .05), Group OM had no significant difference compared with other groups (P > .05). The standard deviations in reverse engineering were much lower than those of digital caliper and optical measurement. Hybrid groups had no significant difference from the pick-up groups in distance error rates (P > .05). Conclusion. The reverse engineering technique demonstrated its potential as an evaluation technique of 3D accuracy of impression techniques.

The correlation between physique and dental arch size

  • Lee, Seung-Hun;Park, In-Suk
    • Journal of Korean society of Dental Hygiene
    • /
    • v.20 no.1
    • /
    • pp.11-18
    • /
    • 2020
  • Objectives: We analyzed the correlation between physique and size of the dental arch of college students with normal occlusion. Methods: Ninety-nine college students filled out the prepared questionnaire. The length and width of the dental arch of the students was measured using a plaster model after taking an impression. The data were analyzed using the t-test and correlational analysis. Results: The maxilla arch length was 3.70 mm longer and the inter-molar width of the maxilla was 3.06 mm longer in men (both p<0.01) than in women. Additionally, the mandible was 3.66 mm longer in men as compared to those in the women (p<0.01). As height increased, there was increase in the body weight (α=0.683, p<0.01), maxilla arch length (α=0.373, p<0.01), molar width of the maxilla (α=0.214, p<0.05), and the mandible (α=0.280, p<0.01). The greater the weight increase, the greater the maxillary arch length increase (α=0.392, p<0.01), and the greater the molar width of the maxilla (α=0.336, p<0.01) and mandible (α=0.502, p<0.01) increase. Conclusions: As physical size (both height and weight) increased, the maxillary length and molar width also increased. Based on the results of this study, the cause of malocclusion, form and size of the dental arch, and stable occlusion can be used as basic data.

Comparison of the accuracy of implant digital impression coping (임플란트 디지털 인상용 코핑의 정확성 비교)

  • Ahn, Gyo-Zin;Lee, Joon-Seok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.36 no.1
    • /
    • pp.29-40
    • /
    • 2020
  • Purpose: The purpose of this study was to compare the accuracy of impression taking method using the encoded healing abutment, scan body and pick-up impression coping with different implant angulations. Materials and Methods: Master model was fabricated by 3D printer and three implants were placed into the model with 0°, 10° and 20° mesial angulation. The abutments were secured to each implants and master model was scanned to make a reference model. Group P model was fabricated using pick-up impression copings and model was scanned after securing the abutments. Encoded healing abutment (Group E) and scan body (Group S) were secured on the master model and digital impression was taken using intraoral scanner 15 times each. Each STL files of test groups were superimposed with reference model using best fit alignment and root mean square (RMS) value was analyzed. Results: The RMS values were lowest in Group P, followed by Group S and Group E. Group P showed significant difference with Group S and E (P < 0.05) while there was no significant difference between Group S and E. Correlation between implant angulation and RMS value was significant in Group E (P < 0.05). Conclusion: The pick-up impression coping method showed higher accuracy and there was no significant difference in accuracy between the healing abutment and the scan body. The clinical use of the encoded healing abutment is possible, but it should be used with caution in the case of angulated implant.

Effect of interproximal undercut on the dimensional accuracy of impression (치간 유두 소실로 인한 언더컷이 인상체의 체적 정확도에 미치는 영향)

  • Lee, Ju-Ri;Kim, Seok-Gyu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.4
    • /
    • pp.330-336
    • /
    • 2015
  • Purpose: This study evaluated the effect of loss of interproximal papilla, creating an undercut, on the accuracy of impression materials. Materials and methods: Two addition type silicone impression materials ($Extrude^{(R)}$ Speed Wash, $Imprint^{TM}$ II Quick Step Light Body) and one alginate impression material (Cavex Impressional) were used to make impressions of a maxillary master model simulating clinical conditions with or without interproximal papilla. Stone was poured in the impressions and working casts were fabricated. A total of 6 groups with 6 working casts in each group were scanned using 3-dimensional optical scanner. The accuracy of the impressions was assessed by measuring the dimensional changes (${\Delta}I$ (%)) of 6 distances on working casts compared to a master model with a 3-dimensional digitizing and inspection software. The data were analyzed by two-way ANOVA (P<.05). Results: Three of 6 distances showed statistically significant differences among the impression materials. Only 1 of 6 distances in alginate impression showed a statistically significant difference between casts with and without interproximal papilla (P=.047). Conclusion: The presence of undercut due to loss of interproximal papilla did not significantly influence the dimensional accuracy of addition type silicone and alginate impression materials.

Microsurgical Approach for Root Coverage of Receding Gingiva in the Esthetic Zone

  • Mohan, Ranjana;Jain, Rohit
    • Archives of Reconstructive Microsurgery
    • /
    • v.22 no.2
    • /
    • pp.69-73
    • /
    • 2013
  • Facial esthetics and smiling are key components in nonverbal communication and have an important role in determination of the first impression of a person. The various components of the smile in dental esthetics include Gingival scaffold, lip framework, and Teeth. The periodontist creates a smile by performing various periodontal plastic microsurgery procedures for management of mucogingival problems. A 25-year-old patient reported to the Department of Periodontology at Teerthanker Mahaveer Dental College and Research Center, Moradabad, Northern India, with the chief complaint of long looking teeth in the upper jaw, making him conscious while smiling. Miller class I gingival recession with Maxillary left canine (23) was diagnosed. Periodontal plastic microsurgery employing double papilla grafting with connective tissue graft harvested from the palate in order to cover denuded root was performed using microsurgical instruments and microsuturing with 6-0 suturing material under magnification. Healing was uneventful, with achievement of 100% root coverage of denuded root after three months. The patient was highly impressed and satisfied with his enhanced smile.

  • PDF

A review of temporomandibular joint-related papers published between 2014-2015

  • Singh, Vaibhav;Sudhakar, K.N.V.;Mallela, Kiran Kumar;Mohanty, Rajat
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.43 no.6
    • /
    • pp.368-372
    • /
    • 2017
  • We conducted a retrospective study and reviewed the temporomandibular joint (TMJ)-related papers published in a leading international journal, Journal of Oral and Maxillofacial Surgery, between January 2014 and December 2015. The study was conducted to ascertain and compare the trends of articles being published in the years 2014 and 2015. A total of 28 articles were reviewed, of which most of the full-length articles were on clinical management and outcomes and the role of radiology. The bulk of the studies were prospective, and less interest was shown in experimental research. A thorough review and analysis thus gives the impression that there is a great need for well-designed clinical studies on TMJ.

Rare Odontalgia of Mandibular Teeth Associated with Migraine: A Case Report

  • Im, Yeong-Gwan;Kang, Jin-Kyu
    • Journal of Oral Medicine and Pain
    • /
    • v.43 no.3
    • /
    • pp.92-96
    • /
    • 2018
  • A 39-year-old male presented with severe pain in right posterior mandibular teeth and temporal area. Initially, the pain in the mandibular teeth was moderate, but the concomitant headache was unbearably severe. His medical history was non-contributory. The clinical and radiographic examination failed to reveal any pathology in the region. There was no tenderness to palpation in the temporalis and masseter muscles or temporomandibular joints. The clinical impression was migraine. The pain in the teeth and headache were aborted using ergotamine tartrate and sumatriptan succinate. Atenolol prevented further pain, while amitriptyline and imipramine had no effect. Migraine can present as non-odontogenic pain in the mandibular teeth, although not as frequently as in the maxillary teeth. A correct diagnosis is essential to avoid unnecessary dental treatments and to manage pain effectively. Clinicians should be able to identify migraine with non-odontogenic dental pain and establish a proper diagnosis through a comprehensive evaluation.

The neutral zone approach for restoration of patient with severe mandibular ridge resorption: A case report (하악 치조제가 심하게 흡수된 환자에서 중립대 인상을 통한 총의치 수복 증례)

  • Cheol Namgung
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.32 no.1
    • /
    • pp.8-15
    • /
    • 2023
  • In case with severely atrophied mandibular ridges, it may be difficult to achieve adequate retention and stability of dentures through the normal functional impression process of complete dentures. In these patients, an approach using the neutral zone raising technique may be an effective alternative. The neutral zone is defined as the area where the pressure of the tongue towards the outside of the mouth and the pressure of the cheek and lips towards the inside are balanced during the normal oral function of the muscular-nervous system. Complete dentures made through neutral zone impression not only improve retention and stability, but also provide adequate tongue space in the posterior teeth area. Additionally, food residues are reduced in the area around artificial teeth, and aesthetics are improved through appropriate facial support.

A study on marginal fit of the ceramic-based hybrid resin restoration for dental CAD/CAM systems (치과용 CAD/CAM 전용 세라믹기반 하이브리드 레진 수복물의 변연 적합 연구)

  • Jeong, Chang-Seop;Park, Jong-Kyoung
    • Journal of Technologic Dentistry
    • /
    • v.42 no.3
    • /
    • pp.228-233
    • /
    • 2020
  • Purpose: This study aimed to assess and compare the marginal fit of ceramic-based hybrid resin restoration (HYB) and zirconia restoration (ZIR) for dental computer-aided design/computer-aided manufacturing systems. Methods: A stainless steel master model was produced. The impression was first made with silicone, and then stone working models were produced. A total of twenty restorations were fabricated with two different materials: ZIR and HYB. The silicone film thickness of the marginal gap was measured using a digital microscope; digital photos were taken at a magnification of ×160, and then analyzed using a measurement software. The values of the result were evaluated with the independent-sample t-test (α=0.05). All statistical analyses were performed with a statistical software. Results: The mean values for the marginal gap was 37.14±2.96 ㎛ for HYB, compared with 40.37±5.26 ㎛ for ZIR. No significant difference was found between ZIR and HYB (p=0.107). Conclusion: As a result, the marginal fit of the restoration fabricated using the hybrid resin was better than that of the restoration fabricated using zirconia. Also, the marginal fit of all groups was below the clinical acceptable range of 120 ㎛. Thus, HYB for dental CAD/CAM system in this study is expected to be suitable for clinical use in dentistry.