• 제목/요약/키워드: Dental error

검색결과 191건 처리시간 0.025초

Validation of a low-cost portable 3-dimensional face scanner

  • Liu, Catherine;Artopoulos, Andreas
    • Imaging Science in Dentistry
    • /
    • 제49권1호
    • /
    • pp.35-43
    • /
    • 2019
  • Purpose: The goal of this study was to assess the accuracy and reliability of a low-cost portable scanner (Scanify) for imaging facial casts compared to a previously validated portable digital stereophotogrammetry device (Vectra H1). This in vitro study was performed using 2 facial casts obtained by recording impressions of the authors, at King's College London Academic Centre of Reconstructive Science. Materials and Methods: The casts were marked with anthropometric landmarks, then digitised using Scanify and Vectra H1. Computed tomography (CT) scans of the same casts were performed to verify the validation of Vectra H1. The 3-dimensional (3D) images acquired with each device were compared using linear measurements and 3D surface analysis software. Results: Overall, 91% of the linear Scanify measurements were within 1 mm of the corresponding reference values. The mean overall surface difference between the Scanify and Vectra images was <0.3mm. Significant differences were detected in depth measurements. Merging multiple Scanify images produced significantly greater registration error. Conclusion: Scanify is a very low-cost device that could have clinical applications for facial imaging if imaging errors could be corrected by a future software update or hardware revision.

Late side effects of bleomycin injection into the lower lip mucosa of a nine-year-old patient with venous malformation

  • Kezia Rachellea Mustakim;Soung Min Kim
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제49권5호
    • /
    • pp.304-307
    • /
    • 2023
  • Venous malformation (VM) is a benign lesion of blood vessels caused by an error in vascular morphogenesis during the embryologic phase. This entity mostly affects the head and neck region, including the lips, tongue, buccal mucosa, gingiva, or palate. VM may cause functional and aesthetic impairments. The anatomical structure and shape of the lips provide an important aesthetic accent for an individual. Therefore, management of VM in the lip area without postoperative defects or scarring is challenging. In this brief communication article, we present a conservative approach to lip VM in a nine-year-old boy using a bleomycin injection that had good aesthetic and functional outcomes. Injection of 2 mL of 1/10 of 15 mg bleomycin in a saline dilution into the lip mucosa may present a drug reaction as a white plaque and reddish owl eye lesion that takes up to three weeks to resolve without a scar. It is important to recognize the characteristics and self-limiting nature of postoperative bleomycin complications to avoid unnecessary treatment.

사랑니 길이 측정을 통한 파노라마와 CBCT의 정확도 연구 (Study on accuracy of panorama and CBCT through length measurement of wisdom teeth)

  • 정천수;김종일
    • 한국방사선학회논문지
    • /
    • 제7권2호
    • /
    • pp.131-136
    • /
    • 2013
  • 치과 방사선 발생장치 중 파노라마는 구강악안면의 넓은 해부학적 구조물을 관찰할 수 있으나, 길이나 각도, 형태의 왜곡이 일어날 수 있다. CBCT는 3차원적 영상진단을 할 수 있으며, 해부학적 구조물 사이의 중첩과 간섭에 의한 오차가 현저히 적은 영상을 얻을 수가 있으나, 시간이 길어 피사체의 움직임에 의해 상의 질이 저하될 수 있고 구강 내에 금속 같은 방사선 불투과성 물체가 존재하면 그 물체를 중심으로 방사상으로 방사선 불투과성 선이 나타날 수 있다. 본 연구에서는 파노라마와 CBCT로 측정된 사랑니 길이와 실제 발치된 치아를 비교하여 치아의 왜곡을 분석함으로써 파노라마와 CBCT의 정확도를 분석하고, 치과 치료시 해부학적으로 유용한 정보를 얻고자 한다. 실험결과 파노라마와 Digital Vernier Caliper의 오차는 크게는 110.7%, 작게는 103.9%로 평균적으로 파노라마가 평균 7.3%로 확대됨을 알 수 있었다. CBCT와 Digital Vernier Caliper에서 측정된 사랑니의 길이는 오차범위 1.3%로 나타났고, 파노라마와 Digital Vernier Caliper에서 측정된 사랑니의 길이는 오차범위 7.3%를 나타냄으로써 CBCT가 파노라마보다 약 6% 정확한 영상을 나타냄을 알 수 있었다. CBCT가 파노라마보다 정확한 영상을 나타냄을 확인할 수 있었지만 CBCT는 파노라마보다 검사비용이 비싸고 피폭선량 또한 많아서 검사 시 적절한 방법을 찾아야 할 것으로 사료된다.

3차원 두부영상의 기준좌표계 설정을 위한 연구: 1부 CT영상에서 3차원 계측점의 재현성 (Formulation of a reference coordinate system of three-dimensional (3D) head & neck images: Part I. Reproducibility of 3D cephalometric landmarks)

  • Park, Jae-Woo;Kim, Nam-Kug;Chang, Young-Il
    • 대한치과교정학회지
    • /
    • 제35권5호
    • /
    • pp.388-397
    • /
    • 2005
  • 이 연구는 기존의 두부방사선사진에서 사용되었던 계측점들을 3차원으로 재구성한 CT자료에서 다시 정의하고, 그 점들의 재현도를 조사함으로써. 재현성이 높고 해부학적 특징을 잘 표현하는 점들을 제안하고자 시행하였다. 3차원 영상에서 상대적 좌표 값을 구하기 위해 어느 4점도 같은 평면에 존재하지 않는 7개의 고정점을 선정하여 기준 좌표계를 설정하였다. V works 4.0 (Cybermed inc., Seoul. Korea)을 이용하여 고정점과 1점 설정을 위한 volume model (voxel size=4*4*2, threshold value-639)을 형성한 후 계측점을 선택하였으며. 나머지 점들은 모두 volume mode의 MPR 창을 이용하여 선정하였다 이렇게 선정한 계측점을 V 녁ㅎㄷ교 (Cybermed Inc.. Seoul, Korsa)로 이출하여 각 점의 상대적 공간 좌표 값을 구하였다 모든 자료는 2주 간격으로 2번 측정한 후 재현도를 계산하였다 각 계측점의 재현도는 x축 $0.13\~1.24mm$, y축 $0.23\~1.53mm$, z축 $0.15\~1.81mm$로 유사한 범위를 보였다 재현도가 우수한 것은 고정점을 이용한 1점이며 봉합에 의해 정의되는 J점의 재현도가 비교적 낮게 나타났다.

치아장축 각도 측정 정확도에 대한 4종 파노라마 방사선 촬영기의 비교 (COMPARISON OF FOUR PANORAMIC DENTAL RADIOGRAPHIC SYSTEMS FOR TOOTH ANGULATION MEASUREMENT ACCURACY UNDER DIFFERENT TOLERENCES)

  • 스테이시 듀마스 버슨;알렌조지 화만;강병철
    • 치과방사선
    • /
    • 제24권2호
    • /
    • pp.317-326
    • /
    • 1994
  • 이 연구의 목적은 Philips Oralix Pan BC, GE Panelipse, SS White Panorex 1, SS White Panorex 2의 4종의 X-선기기로 촬영한 파노라마 방사선사진상에서 치아장축 각도측정시 오차 허용도에 따른 정확도를 비교 평가하는 것이다. 파노라마 방사선사진 촬영기에서 건조두개골을 (1)정확한 촬영위치, (2) 전방 5㎜이동, (3) 후방 5㎜이동, (4) 전방 10/sup 0/ 기울인 위치, (5) 두개골을 후방 10/sup 0/ 기울인 위치 (6) 두개골을 좌측으로 5㎜ 이동시킨 위치 등 촬영 위치를 6가지로 변화시켜서 임의로 정한 평면 기준선과 협측의 치아장축과의 각도를 측정하여 건조두개골에서의 실측치와 비교하였다. 그 결과는 다음과 같았다. 1.치아장축의 각도 측정결과는 파노라마X-선 촬영기의 종류 및 촬영위치에 관계없이 건조두개골에서의 측정치와 방사선사진상의 측정치의 유의성 있는 상관관계를 갖었다. (p<0.05) 2. 건조두개골에서의 치아장축 각도 측정치를 기준으로 정확한 촬영위치에서 촬영한 파노라마 방사선 사진상의 오차 허용도를 +/-3/sup 0/로 하였을 때, SS White Panorex 1은 측정치의 74%, GE Panelipse는 측정치의 67%, Philips Oralix Pan DC와 SS White panorex 2는 측정치의 64%가 이 오차의 범위내에 있었다. 3. 건조두개골에서의 치아장축 각도 측정치를 기준으로 정확한 촬영위치에서 촬영한 파노라마 방사선 사진상에서의 오차 허용도를 +/-5/sup 0/로 하였을 때, SS White Panorex 1 과 GE Panelipse는 측정치의 89%, Philips Oralix Pan DC는 측정치의 85%, SS White Panorex 2 는 측정치의 81% 가 이 오차의 범위내에 있었다.

  • PDF

설유착증 환자의 언어병리학적 평가 (Speech pathologic evaluation of children with ankyloglossia)

  • 이주경
    • 대한음성학회:학술대회논문집
    • /
    • 대한음성학회 2007년도 한국음성과학회 공동학술대회 발표논문집
    • /
    • pp.155-157
    • /
    • 2007
  • Objective : There are close relationship between intraoral abnormal structure and speech-functional problem. Patients with cleft palate & ankyloglossia are typical examples. Patients with abnormal structure can be repaired toward normal structure by operation. Ankyloglossia may cause functional limitation - for example, speech disorder - even if adequate surgical treatment were done. And, each individuals have each speech disorders. The objective of this study is to evaluate the speechs of childrens with ankyloglossia, and to determine whether ankyloglossia is associated with articulation problem. We wanted to present criteria for indication of frenectomy. Study design The experimental group is composed of 10 childrens who visited our department of oral and maxillofacial surgery, dental hospital, Chonbuk university, due to ankyloglossia and articulation problem,. The average age is 5 Y 7M, M : F ratio is 4 : 1 at the time of speech test. The VPI consonant discrimination degree, PPVT, PCAT, Nasometer II, Visi-Pitch test result were obtained from each group. Result : There was significant difference for 'language development' through PPVT. Except 3 members of experimental group, all remainder showed retardation for 'language development'. For 'errored consonant rate', data showed more higher scores in alveolar consonant. There 'consonant error' in experimental group, mostly showed 'alveolar consonant', also a major modality of 'consonant error' was mostly distortion. Conclusion : We can judge the severity of ankyloglossia patient by examinig language development degree & speech test of 'alveolar consonant' . And we can make a decision for frenulotomy using these results.

  • PDF

Accuracy of artificial intelligence-assisted landmark identification in serial lateral cephalograms of Class III patients who underwent orthodontic treatment and two-jaw orthognathic surgery

  • Hong, Mihee;Kim, Inhwan;Cho, Jin-Hyoung;Kang, Kyung-Hwa;Kim, Minji;Kim, Su-Jung;Kim, Yoon-Ji;Sung, Sang-Jin;Kim, Young Ho;Lim, Sung-Hoon;Kim, Namkug;Baek, Seung-Hak
    • 대한치과교정학회지
    • /
    • 제52권4호
    • /
    • pp.287-297
    • /
    • 2022
  • Objective: To investigate the pattern of accuracy change in artificial intelligence-assisted landmark identification (LI) using a convolutional neural network (CNN) algorithm in serial lateral cephalograms (Lat-cephs) of Class III (C-III) patients who underwent two-jaw orthognathic surgery. Methods: A total of 3,188 Lat-cephs of C-III patients were allocated into the training and validation sets (3,004 Lat-cephs of 751 patients) and test set (184 Lat-cephs of 46 patients; subdivided into the genioplasty and non-genioplasty groups, n = 23 per group) for LI. Each C-III patient in the test set had four Lat-cephs: initial (T0), pre-surgery (T1, presence of orthodontic brackets [OBs]), post-surgery (T2, presence of OBs and surgical plates and screws [S-PS]), and debonding (T3, presence of S-PS and fixed retainers [FR]). After mean errors of 20 landmarks between human gold standard and the CNN model were calculated, statistical analysis was performed. Results: The total mean error was 1.17 mm without significant difference among the four time-points (T0, 1.20 mm; T1, 1.14 mm; T2, 1.18 mm; T3, 1.15 mm). In comparison of two time-points ([T0, T1] vs. [T2, T3]), ANS, A point, and B point showed an increase in error (p < 0.01, 0.05, 0.01, respectively), while Mx6D and Md6D showeda decrease in error (all p < 0.01). No difference in errors existed at B point, Pogonion, Menton, Md1C, and Md1R between the genioplasty and non-genioplasty groups. Conclusions: The CNN model can be used for LI in serial Lat-cephs despite the presence of OB, S-PS, FR, genioplasty, and bone remodeling.

Methacrylate 기질 복합레진과 Silorane 기질 복합레진의 치아 수복 시 중합수축응력거동 (Behavior of Polymerization Shrinkage Stress of Methacrylate-based Composite and Silorane-based Composite during Dental Restoration)

  • 박정훈;최낙삼
    • Composites Research
    • /
    • 제28권1호
    • /
    • pp.6-14
    • /
    • 2015
  • 치아의 수복에 사용되는 재료인 Methacrylate 기질 복합레진(Clearfil AP-X)과 Silorane 기질 복합레진(Filtek P90)을 대상으로 스트레인게이지법과 FEM 분석법으로 중합수축응력거동을 분석하였다. 또한 복합레진의 탄성계수와 수축변형률을 중합수축응력과 관계시켜 이론식을 제시하고 이 식의 계산결과와 FEM 분석법의 결과를 비교하였다. 스트레인 게이지법으로 측정한 결과, 중합수축응력의 최대값은 Clearfil AP-X가 Filtek P90 보다 약 2.8배 높게 나타났다. FEM 분석 결과, Von-Mises 응력은 복합레진 수복재와 PMMA 링사이의 계면부에서 최대로 되었으며 시편표면의 계면부가 내부보다 응력집중이 더 컸음을 알았다. 예측식을 통한 반경 방향의 수축응력은 평면응력상태의 FEM 분석법을 통한 값과 비교하여 오차 5% 이내로 정확했음을 확인하였다.

Effectiveness of dexamethasone or adrenaline with lignocaine 2% for prolonging inferior alveolar nerve block: a randomized controlled trial

  • Deo, Saroj Prasad;Ahmad, Md Shakeel;Singh, Abanish
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제48권1호
    • /
    • pp.21-32
    • /
    • 2022
  • Objectives: Inferior alveolar nerve block (IANB) is commonly used for mandibular dentoalveolar surgery. The objective of this study was to evaluate and compare the effectiveness of coadministration of dexamethasone (4 mg/mL) or adrenaline (0.01 mg/mL) as an adjuvant with lignocaine 2% in IANB during third molar surgery (TMS). Patients and Methods: This double-blind, randomized controlled trial was conducted between March and August 2020. The investigators screened patients needing elective TMS under local anesthesia. Based on strict inclusion and exclusion criteria, patients were enrolled in this study. These patients were assigned randomly into two study groups: dexamethasone group (DXN) or adrenaline group (ADN). Outcome variables were postoperative edema, trismus, visual analogue scale (VAS), perioperative analgesia, onset time, and duration of IANB. Results: Eighty-three patients were enrolled in this study, of whom 23 (27.7%) were eliminated or excluded during follow-up. This study thus included data from 60 samples. Mean age was 32.28±11.74 years, including 28 females (46.7%) in the ADN (16 patients, 57.1%) and DXN (12 patients, 42.9%) groups. The duration of action for DXN (mean±standard deviation [SD], 4:02:07±0:34:01 hours; standard error [SE], 0:06:00 hours; log-rank P=0.001) and for ADN (mean±SD, 1:58:34±0:24:52 hours; SE, 0:04:42 hours; log-rank P=0.001) were found. Similarly, time at which 1st analgesic consume and total number of nonsteroidal antiinflammatory drugs need to rescue postoperative analgesia was found statistically significant between study groups (t (58)=-11.95; confidence interval, -2:25:41 to -1:43:53; P=0.001). Early-hours VAS was also significantly different between the study groups. Conclusion: A single injection of dexamethasone prolongs the duration of action of lignocaine 2% IANB. Additionally, it can be used in cases where adrenaline is contraindicated.

치과용 모형 스캐너의 지대치 중첩 과정이 최종 가상 모형에 미치는 영향 (Effect of abutment superimposition process of dental model scanner on final virtual model)

  • 유범영;손큰바다;이규복
    • 대한치과보철학회지
    • /
    • 제57권3호
    • /
    • pp.203-210
    • /
    • 2019
  • 목적: 본 연구는 치과용 모형 스캐너를 이용하여 단일 전장관과 3본 고정성의치 모형을 스캔하는 과정에서 지대치의 중첩 과정이 최종 가상 모형에 미치는 영향을 알아보려 하였다. 재료 및 방법: 평가를 위해 단일 전장관과 3본 고정성의치를 위한 석고 모형을 제작하였다. 그리고 Pindex system을 이용하여 핀 작업된 모형을 제작하였다. 기준 스캔 데이터(CAD Reference Model)와 실험 스캔 데이터(CAD Test Model)를 획득하기 위해서 치과용 모형 스캐너(E1, 3Shape A/S, Copenhagen, Denmark)를 이용했다. 기준 스캔 데이터는 지대치를 분할한 후 탈착하지 않고 스캔하였다. 그리고 실험 스캔 데이터는 분할된 지대치를 분리하여 스캔 후, 기준 스캔 데이터에 중첩되었다(n = 20). 마지막으로 3차원 검사 소프트웨어(release 2018.0.0; Geomagic control X; 3D Systems)를 이용하여 root mean square (RMS)를 분석하였고, 통계 분석은 Mann-Whitney U test를 사용하였다 (${\alpha}=.05$). 결과: 단일 전장관 지대치의 RMS 평균은 $10.93{\mu}m$, 3본 고정성의치 지대치의 RMS 평균은 $6.9{\mu}m$가 나왔다. 두 그룹의 RMS 평균값은 통계적으로 유의한 차이를 보여줬다 (P < .001). 또한 두 그룹의 양(positive)과 음(negative)의 오류는 단일 전장관 지대치는 $9.83{\mu}m$, $-6.79{\mu}m$, 3본 고정성의치 지대치는 $6.22{\mu}m$, $-3.3{\mu}m$의 평균값이 나왔다. 두 그룹의 양과 음의 오류 평균값은 통계적으로 모두 3본 고정성의치 지대치가 단일 전장관 지대치보다 통계적으로 유의하게 낮은 값을 보여주었다 (P < .001). 결론: 핀 작업된 모형의 스캔 과정에서 지대치의 개수가 증가하여도 지대치의 중첩에 의한 오류는 증가하지 않았다. 또한 단일 전장관 지대치에서 유의하게 높은 오류를 보였지만 임상적으로 허용 가능한 스캔 정확도의 범위에 있다.