• Title/Summary/Keyword: Dental casts

Search Result 185, Processing Time 0.031 seconds

Evaluation of the mechanical properties and clinical efficacy of biphasic calcium phosphate-added collagen membrane in ridge preservation

  • Lee, Jung-Tae;Lee, Yoonsub;Lee, Dajung;Choi, Yusang;Park, Jinyoung;Kim, Sungtae
    • Journal of Periodontal and Implant Science
    • /
    • v.50 no.4
    • /
    • pp.238-250
    • /
    • 2020
  • Purpose: This study aimed to evaluate the biocompatibility and the mechanical properties of ultraviolet (UV) cross-linked and biphasic calcium phosphate (BCP)-added collagen membranes and to compare the clinical results of ridge preservation to those obtained using chemically cross-linked collagen membranes. Methods: The study comprised an in vitro test and a clinical trial for membrane evaluation. BCP-added collagen membranes with UV cross-linking were prepared. In the in vitro test, scanning electron microscopy, a collagenase assay, and a tensile strength test were performed. The clinical trial involved 14 patients undergoing a ridge preservation procedure. All participants were randomly divided into the test group, which received UV cross-linked membranes (n=7), and the control group, which received chemically cross-linked membranes (n=7). BCP bone substitutes were used for both the test group and the control group. Cone-beam computed tomography (CBCT) scans were performed and alginate impressions were taken 1 week and 3 months after surgery. The casts were scanned via an optical scanner to measure the volumetric changes. The results were analyzed using the nonparametric Mann-Whitney U test. Results: The fastest degradation rate was found in the collagen membranes without the addition of BCP. The highest enzyme resistance and the highest tensile strength were found when the collagen-to-BCP ratio was 1:1. There was no significant difference in dimensional changes in the 3-dimensional modeling or CBCT scans between the test and control groups in the clinical trial (P>0.05). Conclusions: The addition of BCP and UV cross-linking improved the biocompatibility and the mechanical strength of the membranes. Within the limits of the clinical trial, the sites grafted using BCP in combination with UV cross-linked and BCP-added collagen membranes (test group) did not show any statistically significant difference in terms of dimensional change compared with the control group.

THE STUDY ON THE PREDICTION OF THE MESIODISTAL DIAMETERS OF UNERUPTED CANINES AND PREMOLARS IN KOREAN MALE AND FEMALE (미맹출 영구 견치 및 소구치 근원심 폭경 추정에 관한 연구)

  • Hwang, Min-Sung;Kim, Jung-Wook;Jang, Ki-Taeg;Lee, Sang-Hoon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.29 no.1
    • /
    • pp.115-124
    • /
    • 2002
  • The purpose of this study was to establish regression equations and probability charts for predicting the sum of mesiodistal crown diameters of unerupted unilateral canine and premolars from the sum of mesiodistal crown diameters of four mandibular incisors in Korean male and female. The plaster casts of 162 children(75 boys and 87 girls) among the contestees in 1994-2001 Healthy Dentition Contest in Seoul were measured. Sex differences are compared and the following results were obtained: 1. Bilateral comparison of sum of widths of permanent canine and premolars showed no significant differences for either sex(p>0.05). Sum of widths of permanent canine and premolars of male were significantly larger than that of female(p<0.01). 2. Regression equations for the prediction of sum of widths of permanent canine and premolars in each sex were as follows Male ${\Sigma}Maxillary$ 345 y= 10.45+0.53x Male ${\Sigma}Mandibular$ 345 : y= 10.07+0.51x Female ${\Sigma}Maxillary$ 345 : y=12.65+0.42x Female ${\Sigma}Mandibular$ 345 : y=11.70+0.42x Male+female ${\Sigma}Maxillary$ 345 y=11.01+0.50x Male+female ${\Sigma}Mandibular$ 345 : y=9.87+0.51x

  • PDF

A STUDY ON THE SELECTION OF THE MAXILLARY ANTERIOR ARTIFICIAL TEETH IN KOREAN ADULTS (한국 성인의 상악 전치부 인공치아 선택기준에 관한 계측학적 연구)

  • Ahn Hyun-Jeong;Yang Hong-So;Park Ha-Ok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.40 no.5
    • /
    • pp.484-492
    • /
    • 2002
  • The selection of the maxillary anterior artificial teeth is made primarily for esthetics and they must be in harmony with the surrounding oral environment. However the selection of artificial teeth is based on the large degree of subjective judgement or the dentists, therefore, this is one of the most unscientific processes. This study was performed to determine clinically whether there is correlation among the width of the maxillary central incisor(WMCI), the intercanine distance (ICD) the facial width(FW), and the interalar nasal width(IAW) in Korean adults, and to provide the selection standards for the maxillary anterior artificial teeth. The casts were obtained from 91 undergraduate dental students(49 males and 42 females) with Angle's class I occlusion presenting well-arranged intact anterior teeth. The WMCI and ICD were measured on the casts with a vernier calipers($Miltex^{(R)}$, Germany). The photographic procedures under standardized conditions were performed to record each subject's frontal face using digital camera($Olympus^{(R)}$, C-2500L, Japan). The FW and IAW were measured with image analyzer($Image-Pro^{(R)}$ PLUS. media cybermetrics. USA). The results were obtained as follows : 1. The mean WMCI was $8.11{\pm}0.67mm$, ICD was $37.88{\pm}2.15mm$, FW was $141.29{\pm}5.84mm$. and IAW was $37.85{\pm}2.29 mm$. 2. The ratios of FW/WMCI, FW/ICD, IAW/ICD were 17.4, 3.7, 1.0 respectively. 3. All measurements(WMCI, ICD, FW, and IAW) of male group were longer than those of female group significantly in Student's t-test(p<0.01). 4. There was significant correlation between WMCI, ICD, FW, and IAW in Pearson's correlation analysis(p<0.01). 5, The relationship between IAW and ICD shows the strongest correlation among six combinations in linear regression analysis($R^2$=0.753, Y=7.046+0.815X). The FW and IAW could be very reliable guides for the selection of the maxillary anterior artificial teeth.

Relationship between Mandibular Midline Shift and First Moral Relation, and Their Effects on the Mandibular Height and the Occlusal Plane Angle (하악정중선의 편위와 제 1대구치 교합관계가 하악골의 높이 및 교합면 경사에 미치는 영향)

  • Han, Kyung-Soo;Kim, Chang-Hyun
    • Journal of Oral Medicine and Pain
    • /
    • v.25 no.2
    • /
    • pp.205-214
    • /
    • 2000
  • This study was performed to investigate the relationship between mandibular midline shift and anteroposterior first molar occlusal relation, and their effects on the mandibular height and the occlusal plane angle. For this study, 49 patients with temporomandibular disorders were selected. They did not show facial asymmetry and their facial midline coincide with maxillary dental midline. Upper and lower mandibular impression were taken and the casts were fabricated. Amount and direction of the mandibular midline shift and the anteroposterior shift between the two occluding first molars were measured on the casts. Several items related to height such as mandibular height from top of the articular surface of the condyle to curve changing point between antegonial notch and mandibular angle, condylar height which was the vertical distance from the articular surface to retroepicondyle of the condyle, and sigmoid height from the deepest point of sigmoid notch to the curve changing point and the occlusal plane angle were also measured on the panoramic and on the transcranial radiographs. Correlation between midline shift and anteroposterior first molar relation and comparison between right and left mandibular height by the midline shift and the first molar relation were analysed by SPSS windows program. The results of this study were as follows : 1. Mean amount of midline shift in the subjects with midline shift were 2.0mm for both side, respectively. The first molar relation of the ipsilateral side of midline shift showed Angle class II tendency and the contralateral side showed Angle class III tendency, which meant drift of the dentition to the side of the midline shift. 2. The occlusal plane angle on the panoramic radiograph were $13.0^{\circ}$ in right, and $12.5^{\circ}$ in left side, and their were no correlation between occlusal plane angle and mandibular midline shift and the first molar occlusal relation. 3. Angle's classification for both sides of the first molar relation were same in about half of all the subjects. Amount of deviation from class I first molar relation, however, were decreased in the contralateral side of observed side. 4. Mandibular height of the ipsilateral side to which mandibular midline shift showed tendency of lower than that of the contralateral side, and there was a tendency that the height was higher in class III subjects, then class II subjects, and lower in class I subjects. However, condylar height did not show any difference in the subjects with midline shift and also show no difference by the first molar occlusal relation.

  • PDF

A study on the limit of orthodontic treatment (교정 치료의 한계에 관한 연구)

  • Kim, Sun-Ju;Park, So-Young;Woo, Hae-Hong;Park, Eun-Jie;Kim, Young-Ho;Lee, Shin-Jae;Moon, Seong-Cheol;Baek, Seung-Hak
    • The korean journal of orthodontics
    • /
    • v.34 no.2 s.103
    • /
    • pp.165-175
    • /
    • 2004
  • Information on the limits of treatment could allow for more rational treatment Planning and better results after treatment. From this point of view, this article has attempted to discuss the limits of orthodontic tooth movement. A relatively wider range of tooth movement is expected after Class III surgical-orthodontics than after conventional orthodontic treatment in general. The purposes of this Paper were: first, to evaluate the reliability of teeth position measuring gauge; and second, to elucidate the limits of orthodontic tooth movement. Dental casts of fifty-fine subjects were analyzed by using Set-up model checker (InVisitec Co., Korea) before and aster the Class III surgical-orthodontic treatment. The changes of maxillary and mandibular dental arch widths were also measured from the canines to the second molars. To test the inter-examiner reliability, randomly selected casts were measured by another examiner. Descriptive statistics and paired t tests were used to explain the tooth movement during treatment. The results showed a relatively good reliability of measuring instruments and a very diverse range of tooth movement. Collective changes by the orthodontic tooth movement evaluated in Class III surgical-orthodontics allowed for a suggestive interpretation of specific treatment patterns. Arch width changes during the inter-arch coordination were mainly the result of tipping in both buccal segments. Based on the results of this study, the possibility of a change in dentition as a result of orthodontic treatment should be understood in order to launch a well-organized plan of treatment.

Investigation of the Distance from One Tooth Center to Adjacent Tooth Center and Dental Arch Size to Develope New Removable Die System for Fabrication of Dental Prosthetic Appliance (치과보철물 제조용 모형 조립체(가철식 치형 시스템) 개발을 위한 인접 치아 중심 간격 및 악궁 크기 조사)

  • Kim, Bu-Sob;Ma, Seung-Ho;Jeong, Kyung-Mok;Byun, Tae-Hee
    • Journal of Technologic Dentistry
    • /
    • v.29 no.2
    • /
    • pp.151-161
    • /
    • 2007
  • To obtain the information of dental arch size and the distance from one tooth center to adjacent tooth center of occlusal surface of each tooth which is perforated by Pindex system on working cast for removable die system, 600 dental casts in Busan were examined. The distance of center of occlusal surface of each tooth and dental arch size were digitized. The results were as follows; 1. Mean values of the distance from center of maxillary central incisor to maxillary lateral incisor(tooth number 11$\sim$12, 21$\sim$22) is 5,7 mm, 12$\sim$13(22$\sim$23) is 5.9 mm, 13$\sim$14(23$\sim$24) is 6.9 mm, 14$\sim$15(24$\sim$25) is 7.1 mm, 15$\sim$16(25$\sim$26) is 8.4 mm, 16$\sim$17(26$\sim$27) is 10.2 mm, 11$\sim$21 is 7.30 mm. Mean values of the distance from center of mandibular central incisor to mandibular lateral incisor(tooth number 31$\sim$32, 41$\sim$42) is 4.5 mm, 32$\sim$33(42$\sim$43) is 4.8 mm, 33$\sim$34(43$\sim$44) is 6.3 mm, 34$\sim$35(44$\sim$45) is 7.2 mm, 35$\sim$36(45$\sim$46) is 9.2 mm, 36$\sim$37(46$\sim$47) is 10.7 mm, 31$\sim$41 is 4.7 mm. 2. Mean values of the distance from the center of maxillary right central incisor to the center of maxillary left central incisor(11$\sim$21) is 7.3 mm, 12$\sim$22 is 18.2 mm, 13$\sim$23 is 26.9 mm, 14$\sim$24 is 37.2 mm, 15$\sim$25 is 43.2 mm, 16$\sim$26 is 48.5 mm, 17$\sim$27 is 53.5 mm. Mean values of the distance from the center of mandibular right central incisor to the center of mandibular left central incisor(31$\sim$41) is 4.7 mm, 32$\sim$42 is 13.3 mm, 33$\sim$43 is 21.7 mm, 34$\sim$44 is 31.9 mm, 35$\sim$45 is 38.2 mm, 36$\sim$46 is 44.8 mm, 37$\sim$47 is 50.7 mm. 3. Mean values of the distance from the line of between 11$\sim$21 to 12$\sim$22 is 10.9 mm, 12$\sim$22 to 13$\sim$23 is 8.7 mm, 13$\sim$23 to 14$\sim$24 is 10.3 mm, 14$\sim$24 to 15$\sim$25 is 6.0 mm, 15$\sim$25 to 16$\sim$26 is 5.3 mm, 16$\sim$26 to 17$\sim$27 is 5.0 mm. 31$\sim$41 to 32$\sim$42 is 8.6 mm, 32$\sim$42 to 33$\sim$43 is 8.4 mm, 33$\sim$43 to 34$\sim$44 is 10.2 mm, 34$\sim$44 to 35$\sim$45 is 6.3 mm, 35$\sim$45 to 36$\sim$46 is 6.6 mm, 36$\sim$46 to 37$\sim$47 is 5.9 mm. 4. We checked the bottom side of cast to verify the position of dowel pin. There is no difference upper side and lower side.

  • PDF

Accuracy of dental model based on the state-of-the-art manufacturing technique (첨단 제조기술 기반으로 제작된 치과용 모형의 정확도에 관한 연구)

  • Kim, Jae-Hong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.11
    • /
    • pp.693-700
    • /
    • 2020
  • This study compared the accuracy and reliability of definitive casts fabricated from a digital impression and conventional impression technique. A master model with the prepared upper full-arch tooth was used. Samples of ten plaster models and ten polyurethane models were duplicated using a selected standard master model. Six linear measurements were recorded between the landmarks, directly on each of the stone models and the polyurethane models on two occasions by a double examiner. The Wilcoxon signed-rank test, interclass correlation coefficient (ICC), measurement error (MSE), and limit of agreement (LoA) were used for statistical analysis. The ICC ranged from 0.76 to 0.99 when comparing the stone models and polyurethane models. The mean difference between the stone models and polyurethane models ranged from 0.09mm to 0.20mm, suggesting that stone models might be slightly larger than polyurethane models. Based on this study, the accuracy of the polyurethane models in evaluating the performance of an oral scanner and subtractive technology was acceptable. Further studies will be needed on patient subjects under clinical conditions that may involve missing or malpositioned teeth and fixed dental prostheses because this study was limited to use a standard master model and duplicated sample models in a laboratory setting.

Relationship between intraarch space discrepancy and craniofacial morphology (치열 공간 부조화와 두개안면골격 형태의 상관성)

  • Kim, Yo-Sook;Jung, Ae-Jin;Kang, Kyung-Wha;Kim, Sang-Cheol
    • The korean journal of orthodontics
    • /
    • v.33 no.4 s.99
    • /
    • pp.223-233
    • /
    • 2003
  • The Purpose of this study was to Investigate the relationship between the space discrepancy of the mandibular dentition and craiofacial morphology in adults with good Angle class I occlusion. Dental casts of normal group, crowded group and spaced group were selected on the basis of dental crowding and spacing. Subjects with excessive space to accomodate the lower teeth were classified as spaced group(39). Subjects with a space discrepancy of more than 4mm were classified as crowded group(45). Normal subjects had little or no dental crowding and spacing(40). Various skeletodental measurements in lateral cephalograms were evaluated and compared by ANOVA, Pearson correlation analysis and multiple stepwise regression analysis. The results were as follows; 1. ANB angle was larger in crowded group than in spaced group. 2. Maxilla and mandible in crowded group were inclined more downward and forward than in spaced group, so crowded group was found to have vortical tendency. 3. Anterior cranial base length and mandibular body length were longer in spaced group than in crowded group. 4. According to the multiple stepwise regression analysis with space discrepancy as dependent variable, 40% of variance of space discrepancy could be explained by ANB angle, anterior facial height and ramus height. Multiple regression equation was as follows Space discrepancy=46.51-2.51ANB-0.58AFH+0.65RH

Reproducibility and accuracy of tooth size measurements obtained by the use of computer (컴퓨터를 이용한 치아크기 계측시 재현도와 정확도에 관한 연구)

  • Kim, Eun-Jeong;Hwang, Hyeon-Shik
    • The korean journal of orthodontics
    • /
    • v.29 no.5 s.76
    • /
    • pp.563-573
    • /
    • 1999
  • The purpose of this study was to evaluate the availability of computer system for the measurement of tooth size in the model analysis through the comparison of two measurements: One was to use a computer; and the other was to use vernier calipers. Twenty sets of casts were used, which showed a moderate degree of crowding and full eruption of all teeth. The mesio-distal width of 12 teeth from the left central incisor to the left first molar at each set of the casts were measured twice with vernier calipers and a computer respectively. This measurement was repeated two weeks later. First, for the reproducibility analysis, the two computer measurements were compared then the vernier calipers measurements were compared. Second, all the teeth were sepapated into the region of mesiodistal contact points and its width was measured by a micrometer to obtain standard measurements. For the accuracy analysis, these standard measurements were compared with the measurements from the dental casts using two methods. The difference between them was defined as the measurement error. To investigate the cause of measurement error, an examination was made for the presence and degree of contact point deviation on each tooth from the upper and lower occlusograms, and the mesio-distal angulation of each tooth was measured with TARG. Following results were obtained through statistical analysis. 1. In the analysis for reproducibility; the measurements with vernier calipers showed significant differences in three out of twelve teeth while the computer measurements showed significant differences in one out of twelve teeth. 2. In the analysis for accuracy; compared with the standard measurements, the measurements with vernier calipers showed significant differences in three out of twelve teeth while the computer measurements showed significant differences in two out of twelve teeth. 3. Compared with the standard measurements, the measurements with vernier calipers were apt to be larger at the upper first molar, and smaller at the lower first molar The computer measurements, however, were apt to be larger at both upper and lower first molars. 4. The measurements with vernier calipers showed the largest error at the lower first molar and the degree of error was variable according to the tooth while the difference of error was small in the computer measurements. 5. In the analysis for the correlation of the degree of measurement errors with the contact point deviation index and the mesio-distal crown angulation of each tooth, the measurements with vernier calipers did not show significant correlation while the measurements with computer showed slight Positive correlations. The results of this study indicate that a computer system may be useful for the measurement of tooth size in the model analysis.

  • PDF

Detorque values of abutment screws in a multiple implant-supported prosthesis (다수 임플란트 지지 보철물에서 지대주 나사의 풀림 토크값에 대한 연구)

  • Lee, Ju-Ri;Lee, Dong-Hwan;Hwang, Jae-Woong;Choi, Jung-Han
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.4
    • /
    • pp.280-286
    • /
    • 2010
  • Purpose: This study evaluated the detorque values of screws in a multiple implant-supported superstructure using stone casts made with 2 different impression techniques. Material and methods: A fully edentulous mandibular master model and a metal framework directly connected to four implants (Br${\aa}$nemark $System^{(R)}$; Nobel Biocare AB) with a passive fit to each other were fabricated. Six experimental stone casts (Group 1) were made with 6 non-splinted impressions on a master cast and another 6 experimental casts (Group 2) were made with 6 acrylic resin splinted impressions. The detorque values of screws ($TorqTite^{(R)}$ GoldAdapt Abutment Screw; Nobel Biocare AB) were measured twice after the metal framework was fastened onto each experimental stone cast with 20 Ncm torque. Detorque values were analyzed using the mixed model with the fixed effect of screw and reading and the random effect of model for the repeated measured data at a .05 level of ignificance. Results: The mean detorque values were 7.9 Ncm (Group 1) and 8.1 Ncm (Group 2), and the mean of minimum detorque values were 6.1 Ncm (Group 1) and 6.5 Ncm (Group 2). No statistically significant differences between 2 groups were found and no statistically significant differences among 4 screws were found for detorque values. No statistically significant differences between 2 groups were also found for minimum detorque values. Conclusion: In a multiple external hexagon implant-supported prosthesis, no significant differences between 2 groups were found for detorque values and for minimum detorque values. There seems to be no significant differences in screw joint stability between 2 stone cast groups made with 2 different impression techniques.